Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38912832

RESUMEN

AIMS: To evaluate different cardiovascular magnetic resonance (CMR) parameters for the differentiation of light chain amyloidosis (AL) and transthyretin-related amyloidosis (ATTR). METHODS AND RESULTS: In total, 75 patients, 53 with cardiac amyloidosis (20 patients with AL (66±12 years, 14 males [70%]) and 33 patients with ATTR (78±5 years, 28 males [88%])) were retrospectively analyzed regarding CMR parameters such as T1 and T2 mapping, extracellular volume (ECV), and late gadolinium enhancement (LGE) distribution patterns, and myocardial strain, and compared to a control cohort with other causes of left ventricular hypertrophy (LVH; 22 patients (53±16 years, 17 males [85%])). One way-ANOVA and receiver operating characteristic analysis were used for statistical analysis. ECV was the single best parameter to differentiate between cardiac amyloidosis and controls (area under the curve [AUC]: 0.97, 95% confidence intervals [CI]: 0.89-0.99, p<.0001, cutoff: >30%). T2 mapping was the best single parameter to differentiate between AL and ATTR amyloidosis (AL: 63±4 ms, ATTR: 58±2 ms, p<.001, AUC: 0.86, 95% CI: 0.74-0.94, cutoff: >61 ms). Subendocardial LGE was predominantly observed in AL patients (10/20 [50%] vs. 5/33 [15%]; p=.002). Transmural LGE was predominantly observed in ATTR patients (23/33 [70%] vs. 2/20 [10%]; p<.001). The diagnostic performance of T2 mapping to differentiate between AL and ATTR amyloidosis was further increased with the inclusion of LGE patterns (AUC: 0.96, 95% CI: 0.86-0.99]; p=.05). CONCLUSION: ECV differentiates cardiac amyloidosis from other causes of LVH. T2 mapping combined with LGE differentiates AL from ATTR amyloidosis with high accuracy on a patient level.

2.
J Cardiovasc Magn Reson ; 26(1): 101035, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38460841

RESUMEN

BACKGROUND: Patients are increasingly using Generative Pre-trained Transformer 4 (GPT-4) to better understand their own radiology findings. PURPOSE: To evaluate the performance of GPT-4 in transforming cardiovascular magnetic resonance (CMR) reports into text that is comprehensible to medical laypersons. METHODS: ChatGPT with GPT-4 architecture was used to generate three different explained versions of 20 various CMR reports (n = 60) using the same prompt: "Explain the radiology report in a language understandable to a medical layperson". Two cardiovascular radiologists evaluated understandability, factual correctness, completeness of relevant findings, and lack of potential harm, while 13 medical laypersons evaluated the understandability of the original and the GPT-4 reports on a Likert scale (1 "strongly disagree", 5 "strongly agree"). Readability was measured using the Automated Readability Index (ARI). Linear mixed-effects models (values given as median [interquartile range]) and intraclass correlation coefficient (ICC) were used for statistical analysis. RESULTS: GPT-4 reports were generated on average in 52 s ± 13. GPT-4 reports achieved a lower ARI score (10 [9-12] vs 5 [4-6]; p < 0.001) and were subjectively easier to understand for laypersons than original reports (1 [1] vs 4 [4,5]; p < 0.001). Eighteen out of 20 (90%) standard CMR reports and 2/60 (3%) GPT-generated reports had an ARI score corresponding to the 8th grade level or higher. Radiologists' ratings of the GPT-4 reports reached high levels for correctness (5 [4, 5]), completeness (5 [5]), and lack of potential harm (5 [5]); with "strong agreement" for factual correctness in 94% (113/120) and completeness of relevant findings in 81% (97/120) of reports. Test-retest agreement for layperson understandability ratings between the three simplified reports generated from the same original report was substantial (ICC: 0.62; p < 0.001). Interrater agreement between radiologists was almost perfect for lack of potential harm (ICC: 0.93, p < 0.001) and moderate to substantial for completeness (ICC: 0.76, p < 0.001) and factual correctness (ICC: 0.55, p < 0.001). CONCLUSION: GPT-4 can reliably transform complex CMR reports into more understandable, layperson-friendly language while largely maintaining factual correctness and completeness, and can thus help convey patient-relevant radiology information in an easy-to-understand manner.


Asunto(s)
Comprensión , Imagen por Resonancia Magnética , Valor Predictivo de las Pruebas , Humanos , Reproducibilidad de los Resultados , Variaciones Dependientes del Observador , Alfabetización en Salud , Educación del Paciente como Asunto , Enfermedades Cardiovasculares/diagnóstico por imagen , Femenino , Masculino
3.
Diagnostics (Basel) ; 13(13)2023 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-37443565

RESUMEN

Persistent or recurrent cardiovascular symptoms have been identified as one of the hallmarks of long-COVID or post-acute sequelae of SARS-CoV-2 infection (PASC). The purpose of this study was to determine the prevalence and extent of cardiac abnormalities in patients referred for cardiac MRI due to clinical evidence of PASC. To investigate this, two tertiary care hospitals identified all patients who were referred for cardiac MRI under the suspicion of PASC in a 2-year period and retrospectively included them in this study. Patients with previously known cardiac diseases were excluded. This resulted in a total cohort of 129 patients (63, 51% female; age 41 ± 16 years). The majority of patients (57%) showed normal cardiac results. No patient had active myocarditis or an acute myocardial infarction. However, 30% of patients had evidence of non-ischemic myocardial fibrosis, which exceeds the prevalence in the normal adult population and suggests that a possible history of myocarditis might explain persistent symptoms in the PASC setting.

4.
Radiologie (Heidelb) ; 63(7): 497-506, 2023 Jul.
Artículo en Alemán | MEDLINE | ID: mdl-37289254

RESUMEN

BACKGROUND: Photon-counting detector computed tomography (PCD-CT) is a CT technology that overcomes many limitations of conventional detectors. Direct conversion of photons hitting the detector into electrical signals combined with more sensitive and accurate photon detection simultaneously allows spectral evaluation and also potential reduction in radiation exposure to the patient. The combination of energy thresholds and elimination of detector septa allows for a reduction of electronic noise, an increase of spatial resolution, and an improvement of dose efficiency. ACHIEVEMENTS: Recent research has confirmed significantly reduced image noise, reduced radiation dose, increased spatial resolution, improved iodine signal, and a reduction in artifacts. Spectral imaging potentiates these effects and also allows retrospective calculation of virtual monoenergetic images, virtual noncontrast images or iodine maps. Thus, the photon-counting technique offers the possibility of using various contrast agents, with the prospect of single-scan multiphase imaging or visualization of specific metabolic processes. Therefore, further research and complementary approval processes are necessary for clinical application. Likewise, further research is needed to develop and validate optimal settings and reconstructions for a wide variety of situations, as well as to test new application possibilities. CONCLUSIONS: The only photon-counting detector CT device available on the market to date received clinical approval in 2021. It remains to be seen which other applications will become possible through improvements in hardware and software. This technology has already demonstrated an impressive superiority compared with the current standard of CT imaging, especially regarding high-resolution imaging of detailed structures and examinations with high radiation exposure.


Asunto(s)
Yodo , Tomografía Computarizada por Rayos X , Humanos , Estudios Retrospectivos , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Medios de Contraste
5.
J Am Heart Assoc ; 12(9): e029492, 2023 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-37119085

RESUMEN

Background The objective of this study was to investigate cardiac abnormalities in intensive care unit (ICU) survivors of critical illness and to determine whether temporary acute kidney injury (AKI) is associated with more pronounced findings on cardiovascular magnetic resonance. Methods and Results There were 2175 patients treated in the ICU (from 2015 until 2021) due to critical illness who were screened for study eligibility. Post-ICU patients without known cardiac disease were prospectively recruited from March 2021 to May 2022. Participants underwent cardiovascular magnetic resonance including assessment of cardiac function, myocardial edema, late gadolinium enhancement, and mapping including extracellular volume fraction. Student t test, Mann-Whitney U test, and χ2 tests were used. There were 48 ICU survivors (46±15 years of age, 28 men, 29 with AKI and continuous kidney replacement therapy, and 19 without AKI) and 20 healthy controls who were included. ICU survivors had elevated markers of myocardial fibrosis (T1: 995±31 ms versus 957±21 ms, P<0.001; extracellular volume fraction: 24.9±2.5% versus 22.8±1.2%, P<0.001; late gadolinium enhancement: 1% [0%-3%] versus 0% [0%-0%], P<0.001), more frequent focal late gadolinium enhancement lesions (21% versus 0%, P=0.03), and an impaired left ventricular function (eg, ejection fraction: 57±6% versus 60±5%, P=0.03; systolic longitudinal strain: 20.3±3.7% versus 23.1±3.5%, P=0.004) compared with healthy controls. ICU survivors with AKI had higher myocardial T1 (1002±33 ms versus 983±21 ms; P=0.046) and extracellular volume fraction values (25.6±2.6% versus 23.9±1.9%; P=0.02) compared with participants without AKI. Conclusions ICU survivors of critical illness without previously diagnosed cardiac disease had distinct abnormalities on cardiovascular magnetic resonance including signs of myocardial fibrosis and systolic dysfunction. Findings were more abnormal in participants who experienced AKI with necessity of continuous kidney replacement therapy during their ICU stay. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT05034588.


Asunto(s)
Lesión Renal Aguda , Cardiomiopatías , Cardiopatías Congénitas , Masculino , Humanos , Adulto , Medios de Contraste , Enfermedad Crítica , Gadolinio , Imagen por Resonancia Cinemagnética , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/etiología , Cardiomiopatías/patología , Fibrosis , Espectroscopía de Resonancia Magnética , Sobrevivientes , Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/etiología
6.
Eur J Radiol ; 163: 110831, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37059004

RESUMEN

PURPOSE: To compare standard breath-hold (BH) cine imaging to a radial pseudo-golden-angle free-breathing (FB) technique in congenital heart disease (CHD). METHODS: In this prospective study, short-axis and 4-chamber BH and FB cardiac MRI sequences of 25 participants with CHD acquired at 1.5 Tesla, were quantitatively compared regarding ventricular volumes, function, interventricular septum thickness (IVSD), apparent signal to noise ratio (aSNR), and estimated contrast to noise ratio (eCNR). For qualitative comparison, three image quality criteria (contrast, endocardial edge definition, and artefacts) were rated on a 5-point Likert scale (5: excellent, 1: non-diagnostic). Paired t-Test was used for group comparisons, Bland-Altman analysis for agreement between techniques. Inter-reader agreement was compared using intraclass correlation coefficient. RESULTS: IVSD (BH 7.4 ± 2.1 mm vs FB 7.4 ± 1.9 mm, p =.71), biventricular ejection fraction (left ventricle [LV]: 56.4 ± 10.8% vs 56.1 ± 9.3%, p =.83; right ventricle [RV]: 49.5 ± 8.6% vs 49.7 ± 10.1%, p =.83), and biventricular end diastolic volume (LV: 176.3 ± 63.9 ml vs 173.9 ± 64.9 ml, p =.90; RV: 185.4 ± 63.8 ml vs 189.6 ± 66.6 ml, p =.34) were comparable. Mean measurement time for FB short-axis sequences was 8.1 ± 1.3 compared to 4.4 ± 1.3 min for BH (p <.001). Subjective image quality between sequences was deemed comparable, (4.6 ± 0.6 vs 4.5 ± 0.6, p =.26, for 4-chamber views) with a significant difference regarding short-axis views (4.9 ± 0.3 vs 4.5 ± 0.6, p =.008). aSNR was similar (BH 25.8 ± 11.2 vs FB 22.2 ± 9.5, p =.24), while eCNR was higher for BH (89.1 ± 36.1 vs 68.5 ± 32.1, p =.03). CONCLUSION: FB sequences yielded comparable results to BH regarding image quality, biventricular volumetry, and function, though measurement times were longer. The FB sequence described might be clinically valuable when BHs are insufficiently performed.


Asunto(s)
Cardiopatías Congénitas , Respiración , Humanos , Estudios Prospectivos , Imagen por Resonancia Magnética/métodos , Cardiopatías Congénitas/diagnóstico por imagen , Imagen por Resonancia Cinemagnética/métodos , Contencion de la Respiración , Reproducibilidad de los Resultados
7.
Eur Radiol ; 33(8): 5498-5508, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36949253

RESUMEN

OBJECTIVES: To find simple imaging-based features on cardiac magnetic resonance (CMR) that are associated with major adverse cardiovascular events (MACE) in takotsubo syndrome (TTS). METHODS: Patients with TTS referred for CMR between 2007 and 2021 were retrospectively evaluated. Besides standard CMR analysis, commonly known complications of TTS based on expert knowledge were assessed and summarised via a newly developed PE2RT score (one point each for pleural effusion, pericardial effusion, right ventricular involvement, and ventricular thrombus). Clinical follow-up data was reviewed up to three years after discharge. The relationship between PE2RT features and the occurrence of MACE (cardiovascular death or new hospitalisation due to acute myocardial injury, arrhythmia, or chronic heart failure) was examined using Cox regression analysis and Kaplan-Meier estimator. RESULTS: Seventy-nine patients (mean age, 68 ± 14 years; 72 women) with TTS were included. CMR was performed in a median of 4 days (IQR, 2-6) after symptom onset. Over a median follow-up of 13.3 months (IQR, 0.4-36.0), MACE occurred in 14/79 (18%) patients: re-hospitalisation due to acute symptoms (9/79, 11%) or chronic heart failure symptoms (4/79, 5%), and cardiac death (1/79, 1%). Patients with MACE had a higher PE2RT score (median [IQR], 2 [2-3] vs 1 [0-1]; p < 0.001). PE2RT score was associated with MACE on Cox regression analysis (hazard ratio per PE2RT feature, 2.44; 95%CI: 1.62-3.68; p < 0.001). Two or more PE2RT complications were strongly associated with the occurrence of MACE (log-rank p < 0.001). CONCLUSIONS: The introduced PE2RT complication score might enable an easy-to-assess outcome evaluation of TTS patients by CMR. KEY POINTS: • Complications like pericardial effusion, pleural effusion, right ventricular involvement, and ventricular thrombus (summarised as PE2RT features) are relatively common in takotsubo syndrome. • The proposed PE2RT score (one point per complication) was associated with the occurrence of major adverse cardiac events on follow-up. • Complications easily detected by cardiac magnetic resonance imaging can help clinicians derive long-term prognostic information on patients with takotsubo syndrome.


Asunto(s)
Insuficiencia Cardíaca , Cardiomiopatía de Takotsubo , Trombosis , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Cardiomiopatía de Takotsubo/diagnóstico por imagen , Función Ventricular Izquierda , Estudios Retrospectivos , Imagen por Resonancia Magnética/efectos adversos , Pronóstico , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/etiología , Espectroscopía de Resonancia Magnética , Imagen por Resonancia Cinemagnética/efectos adversos , Valor Predictivo de las Pruebas , Factores de Riesgo
8.
Invest Radiol ; 58(3): 209-215, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36070533

RESUMEN

OBJECTIVES: The aim of this study was to compare a new compressed sensing (CS) method for T2-weighted propeller acquisitions (T2 CS ) with conventional T2-weighted propeller sequences (T2 conv ) in terms of achieving a higher image quality, while reducing the acquisition time. MATERIALS AND METHODS: Male participants with a clinical suspicion of prostate cancer were prospectively enrolled and underwent prostate magnetic resonance imaging at 3 T. Axial and sagittal images of the T2 conv sequence and the T2 CS sequence were acquired. Sequences were qualitatively assessed by 2 blinded radiologists concerning artifacts, image-sharpness, lesion conspicuity, capsule delineation, and overall image quality using 5-point Likert items ranging from 1 (nondiagnostic) to 5 (excellent). The apparent signal-to-noise ratio and apparent contrast-to-noise ratio were evaluated. PI-RADS scores were assessed for both sequences. Statistical analysis was performed by using Wilcoxon signed rank test and paired samples t test. Intrarater and interrater reliability of qualitative image evaluation was assessed using intraclass correlation coefficient (ICC) estimates. RESULTS: A total of 29 male participants were included (mean age, 66 ± 8 years). The acquisition time of the T2 CS sequence was respectively 26% (axial plane) and 24% (sagittal plane) shorter compared with the T2 conv sequence (eg, axial: 171 vs 232 seconds; P < 0.001). In the axial plane, the T2 CS sequence had fewer artifacts (4 [4-4.5] vs 4 [3-4]; P < 0.001), better image-sharpness (4 [4-4.5] vs 3 [3-3.5]; P < 0.001), better capsule delineation (4 [3-4] vs 3 [3-3.5]; P < 0.001), and better overall image quality (4 [4-4] vs 4 [3-4]; P < 0.001) compared with the T2 conv sequence. The ratings of lesion conspicuity were similar (4 [4-4] vs 4 [3-4]; P = 0.166). In the sagittal plane, the T2 CS sequence outperformed the T2 conv sequence in the categories artifacts (4 [4-4] vs 3 [3-4]; P < 0.001), image sharpness (4 [4-5] vs 4 [3-4]; P < 0.001), lesion conspicuity (4 [4-4] vs 4 [3-4]; P = 0.002), and overall image quality (4 [4-4] vs 4 [3-4]; P = 0.002). Capsule delineation was similar between both sequences (3 [3-4] vs 3 [3-3]; P = 0.07). Intraobserver and interobserver reliability for qualitative scoring were good (ICC intra: 0.92; ICC inter: 0.86). Quantitative analysis revealed a higher apparent signal-to-noise ratio (eg, axial: 52.2 ± 9.7 vs 22.8 ± 3.6; P < 0.001) and a higher apparent contrast-to-noise ratio (eg, axial: 44.0 ± 9.6 vs 18.6 ± 3.7; P ≤ 0.001) of the T2 CS sequence. PI-RADS scores were the same for both sequences in all participants. CONCLUSIONS: CS-accelerated T2-weighted propeller acquisition had a superior image quality compared with conventional T2-weighted propeller sequences while significantly reducing the acquisition time.


Asunto(s)
Imagen por Resonancia Magnética , Neoplasias de la Próstata , Humanos , Masculino , Persona de Mediana Edad , Anciano , Imagen por Resonancia Magnética/métodos , Próstata/diagnóstico por imagen , Reproducibilidad de los Resultados , Neoplasias de la Próstata/diagnóstico por imagen , Relación Señal-Ruido , Artefactos
9.
Eur Heart J Cardiovasc Imaging ; 24(7): 949-960, 2023 06 21.
Artículo en Inglés | MEDLINE | ID: mdl-36423215

RESUMEN

AIMS: The exact role of portal hypertension in cirrhotic cardiomyopathy remains unclear, and it is uncertain whether cardiac abnormalities also occur in non-cirrhotic portal hypertension (NCPH). This magnetic resonance imaging (MRI) study aimed to evaluate the presence of subclinical myocardial dysfunction, oedema, and fibrosis in NCPH. METHODS AND RESULTS: In this prospective study (2018-2022), participants underwent multiparametric abdominal and cardiac MRI including assessment of cardiac function, myocardial oedema, late gadolinium enhancement (LGE), and abdominal and cardiac mapping [T1 and T2 relaxation times, extracellular volume fraction (ECV)]. A total of 111 participants were included [44 participants with NCPH (48 ± 15 years; 23 women), 47 cirrhotic controls, and 20 healthy controls]. The cirrhotic group was dichotomized (Child A vs. Child B/C). NCPH participants demonstrated a more hyperdynamic circulation compared with healthy controls (cardiac index: 3.7 ± 0.6 vs. 3.2 ± 0.8 L/min/m², P = 0.004; global longitudinal strain: -27.3 ± 4.6 vs. -24.6 ± 3.5%, P = 0.022). The extent of abnormalities indicating myocardial fibrosis and oedema in NCPH was comparable with Child A cirrhosis (e.g. LGE presence: 32 vs. 33 vs. 69%, P = 0.004; combined T1 and T2 elevations: 46 vs. 27 vs. 69%, P = 0.017; NCPH vs. Child A vs. Child B/C). Correlations between splenic T1 and myocardial T1 values were found (r = 0.41; P = 0.007). Splenic T1 values were associated with the presence of LGE (odds ratio, 1.010; 95% CI: 1.002, 1.019; P = 0.013). CONCLUSION: MRI parameters of myocardial fibrosis and oedema were altered in participants with NCPH to a similar extent as in compensated cirrhosis and were associated with splenic markers of portal hypertension, indicating specific portal hypertensive cardiomyopathy.


Asunto(s)
Cardiomiopatías , Hipertensión Portal , Niño , Humanos , Femenino , Medios de Contraste , Estudios Prospectivos , Gadolinio , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/etiología , Fibrosis , Imagen por Resonancia Magnética/métodos , Miocardio/patología , Edema/diagnóstico por imagen , Edema/etiología , Edema/patología , Hipertensión Portal/diagnóstico por imagen , Hipertensión Portal/etiología , Hipertensión Portal/patología , Imagen por Resonancia Cinemagnética , Valor Predictivo de las Pruebas
10.
Radiologie (Heidelb) ; 62(Suppl 1): 22-27, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36331586

RESUMEN

BACKGROUND: The rapid development of COVID-19 vaccines in the wake of the COVID-19 pandemic has led to an equally expediently deployed vaccination campaign with more than 12 billion vaccinations administered worldwide. Reports of vaccine-associated adverse reactions (VAARs) have ranged from headaches and pain at the injection site to potentially life-threatening events such as cerebral venous sinus thrombosis. The heart has also not been spared of VAARs, as vaccine-associated myocardial infarction and more commonly, albeit still rare, myocarditis and perimyocarditis have been reported in predominantly young male recipients. METHODOLOGICAL INNOVATIONS: Cardiac magnetic resonance imaging findings of vaccine-associated myocarditis such as prolonged T1 and T2 relaxation times, increased T2 signal intensity ratio, and subepicardial late gadolinium enhancement have been demonstrated to be similar to those in virus-induced myocarditis, enabling the use of the modified 2018 Lake Louise Criteria for diagnostic purposes to confirm vaccination-associated myocardial inflammation. Other reported cardiac findings such as cardiomyopathies and arrhythmias were confined to case reports. The incidence of myocardial infarction was not noted to be higher than in the overall population. CONCLUSION: The overall preliminary prognosis of vaccine- associated myocarditis seems to be good as suggested by initial reports, but long-term follow-up is needed to sufficiently assess possible sequelae and consequences.


Asunto(s)
Vacunas contra la COVID-19 , COVID-19 , Masculino , Humanos , Vacunas contra la COVID-19/efectos adversos , Medios de Contraste , Pandemias , COVID-19/prevención & control , Gadolinio , Imagen por Resonancia Magnética/efectos adversos
11.
J Cardiovasc Magn Reson ; 24(1): 55, 2022 11 17.
Artículo en Inglés | MEDLINE | ID: mdl-36384752

RESUMEN

BACKGROUND: To evaluate the great vessels in young children with complex congenital heart disease (CHD) using non-contrast cardiovascular magnetic resonance angiography (CMRA) based on three-dimensional relaxation-enhanced angiography without contrast (REACT) in comparison to contrast-enhanced steady-state CMRA. METHODS: In this retrospective study from April to July 2021, respiratory- and electrocardiogram-gated native REACT CMRA was compared to contrast-enhanced single-phase steady-state CMRA in children with CHD who underwent CMRA at 3T under deep sedation. Vascular assessment included image quality (1 = non-diagnostic, 5 = excellent), vessel diameter, and diagnostic findings. For statistical analysis, paired t-test, Pearson correlation, Bland-Altman analysis, Wilcoxon test, and intraclass correlation coefficients (ICC) were applied. RESULTS: Thirty-six young children with complex CHD (median 4 years, interquartile range, 2-5; 20 males) were included. Native REACT CMRA was obtained successfully in all patients (mean scan time: 4:22 ± 1:44 min). For all vessels assessed, diameters correlated strongly between both methods (Pearson r = 0.99; bias = 0.04 ± 0.61 mm) with high interobserver reproducibility (ICC: 0.99 for both CMRAs). Native REACT CMRA demonstrated comparable overall image quality to contrast-enhanced CMRA (3.9 ± 1.0 vs. 3.8 ± 0.9, P = 0.018). With REACT CMRA, better image quality was obtained at the ascending aorta (4.8 ± 0.5 vs. 4.3 ± 0.8, P < 0.001), coronary roots (e.g., left: 4.1 ± 1.0 vs. 3.3 ± 1.1, P = 0.001), and inferior vena cava (4.6 ± 0.5 vs. 3.2 ± 0.8, P < 0.001). In all patients, additional vascular findings were assessed equally with native REACT CMRA and the contrast-enhanced reference standard (n = 6). CONCLUSION: In young children with complex CHD, REACT CMRA can provide gadolinium-free high image quality, accurate vascular measurements, and equivalent diagnostic quality compared to standard contrast-enhanced CMRA.


Asunto(s)
Cardiopatías Congénitas , Angiografía por Resonancia Magnética , Masculino , Humanos , Niño , Preescolar , Angiografía por Resonancia Magnética/métodos , Estudios Retrospectivos , Reproducibilidad de los Resultados , Medios de Contraste , Valor Predictivo de las Pruebas , Cardiopatías Congénitas/diagnóstico por imagen
12.
Front Cardiovasc Med ; 9: 1049256, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36440045

RESUMEN

Background: Mass COVID-19 vaccination campaigns have helped impede the COVID-19 pandemic. In rare cases, some vaccines have led to vaccine associated myocarditis in a specific subset of the population, usually young males. Cardiac magnetic resonance (CMR) can reliably diagnose vaccine associated myocarditis, but follow-up data of CMR proven acute myocarditis is scarce. Materials and methods: Nine patients with acute vaccine associated myocarditis underwent baseline and follow-up CMR examinations and were compared to baseline parameters at initial presentation and to a group of 20 healthy controls. CMR protocol included functional assessment, T1 and T2 mapping, T2 signal intensity ratio, strain feature tracking, and late gadolinium enhancement (LGE). Results: Myocarditis patients (n = 9, aged 24 ± 6 years, 8 males) underwent CMR follow-up after an average of 5.8 ± 4.3 months. All patients showed a complete resolution of visual myocardial edema while also demonstrating a reduction in overall LGE extent from baseline to follow-up (4.2 ± 2.1 vs. 0.9 ± 0.8%, p < 0.001), although visual LGE was still noted in all patients. Left ventricular ejection fraction was normal at baseline and at follow-up (58 ± 6 vs. 62 ± 4%, p = 0.10) as well as compared to a healthy control group (60 ± 4%, p = 0.24). T1 (1024 ± 77 vs. 971 ± 34 ms, p = 0.05) and T2 relaxations times (57 ± 6 vs. 51 ± 3 ms, p = 0.03) normalized at follow-up. Most patients reported a resolution of clinical symptoms, while two (22%) reported new onset of exertional dyspnea. Conclusion: Patients with COVID-19 vaccine associated acute myocarditis showed a complete, uncomplicated resolution of myocardial inflammation on follow-up CMR, which was associated with a near complete resolution of symptoms. Minor, residual myocardial scarring was present on follow-up LGE imaging. The long-term implications of the remaining myocardial scar-tissue after vaccine associated myocarditis remain unknown warranting further studies.

13.
Radiol Cardiothorac Imaging ; 4(3): e210318, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35833169

RESUMEN

Purpose: To evaluate the diagnostic performance of layer-specific cardiac MRI feature-tracking (FT) strain analysis in patients with acute myocarditis. Materials and Methods: Seventy patients (mean age, 43 years ± 19 [SD]; 46 men) with clinically defined acute myocarditis and 42 healthy controls who underwent cardiac MRI from March 2014 to November 2018 were retrospectively analyzed. FT-based left ventricular peak systolic global longitudinal strain (GLS) and global circumferential strain (GCS) were assessed at subendocardial, midmyocardial, and subepicardial layers. The 2018 Lake Louise criteria (LLC) were assessed. Patients with myocarditis were dichotomized into two groups: those with preserved and those with reduced ejection fraction. For statistical analysis, unpaired t test, one-way analysis of variance, Pearson correlation, and receiver operating characteristic analysis were used. Results: GLS and GCS values of all layers (eg, midmyocardial GCS: -21.3% ± 5.5 vs -28.0% ± 4.3; P < .001) were impaired in patients with myocarditis compared with controls. Only subepicardial GLS (-20.0% ± 3.3 vs -17.5% ± 3.3; P < .001) and midmyocardial GCS values (-28.0% ± 4.3 vs -23.1% ± 4.3; P < .001) could differentiate between controls and patients with preserved ejection fraction. Midmyocardial GCS correlated with inflammatory myocardial parameters (eg, late gadolinium enhancement percentage, r = 0.48, P < .001). Midmyocardial GCS (area under the receiver operating characteristic curve [AUC], 0.82) and subepicardial GLS (AUC, 0.77) had the highest diagnostic performance for acute myocarditis diagnosis (P < .05 against all other strain parameters). The diagnostic performance of the 2018 LLC was significantly improved by inclusion of these two strain parameters (AUC, 0.92 vs 0.97; P = .04). Conclusion: Diagnostic performance of cardiac MRI FT strain was different between myocardial layers in acute myocarditis, with midmyocardial GCS and subepicardial GLS providing the highest diagnostic performance.Keywords: MRI, Cardiac, Heart, Left Ventricle, Inflammation, Tissue Characterization, MR-Functional Imaging, Feature-Tracking Strain, Acute Myocarditis Supplemental material is available for this article. © RSNA, 2022.

14.
Sci Rep ; 12(1): 9422, 2022 06 08.
Artículo en Inglés | MEDLINE | ID: mdl-35676399

RESUMEN

We aimed to investigate the diagnostic utility of MRI extracellular volume fraction (ECV) for the assessment of liver cirrhosis severity as defined by Child-Pugh class. In this retrospective study, 90 patients (68 cirrhotic patients and 22 controls), who underwent multiparametric liver MRI, were identified. Hepatic T1 relaxation times and ECV were assessed. Clinical scores of liver disease severity were calculated. One-way analysis of variance (ANOVA) followed by Tukey's multiple comparison test, Spearman's correlation coefficient, and receiver operating characteristic (ROC) analysis were used for statistical analysis. In cirrhotic patients, hepatic native T1 increased depending on Child-Pugh class (620.5 ± 78.9 ms (Child A) vs. 666.6 ± 73.4 ms (Child B) vs. 828.4 ± 91.2 ms (Child C), P < 0.001). ECV was higher in cirrhotic patients compared to the controls (40.1 ± 11.9% vs. 25.9 ± 4.5%, P < 0.001) and increased depending of Child-Pugh class (33.3 ± 6.0% (Child A) vs. 39.6 ± 4.9% (Child B) vs. 52.8 ± 1.2% (Child C), P < 0.001). ECV correlated with Child-Pugh score (r = 0.64, P < 0.001). ECV allowed differentiating between Child-Pugh classes A and B, and B and C with an AUC of 0.785 and 0.944 (P < 0.001, respectively). The diagnostic performance of ECV for differentiating between Child-Pugh classes A and B, and B and C was higher compared to hepatic native T1 (AUC: 0.651 and 0.910) and MELD score (AUC: 0.740 and 0.795) (P < 0.05, respectively). MRI-derived ECV correlated with Child-Pugh score and had a high diagnostic performance for the discrimination of different Child-Pugh classes. ECV might become a valuable non-invasive biomarker for the assessment of liver cirrhosis severity.


Asunto(s)
Cirrosis Hepática , Imagen por Resonancia Magnética , Humanos , Hígado/diagnóstico por imagen , Hígado/patología , Cirrosis Hepática/patología , Curva ROC , Estudios Retrospectivos
15.
Sci Rep ; 12(1): 9934, 2022 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-35705551

RESUMEN

To explore the image quality and radiation dose of dual source high-pitch cardiac computed tomography with tailored contrast injection protocols for pediatric congenital heart disease patients (CHD). In total, 27 infants with CHD (median age 109 days [IQR 6-199]) were retrospectively analyzed regarding dose length product (DLP) and effective dose (ED) after undergoing cardiothoracic CT imaging. Scan parameters were adjusted on a dual source/detector CT (DSCT) to minimize radiation dose while maintaining adequate quality. Image acquisition was performed at 70% of the R-R interval. Dose reducing measures included prospective electrocardiogram gating, utilizing slow injection velocities and foregoing bolus tracking during contrast injection. Image quality was assessed for artefacts, vessel definition, and noise on a 5-point scale (1 non-diagnostic, 5 excellent). Series were scored on a 0-to-3-point scale regarding answered clinical questions (0 non-diagnostic, 3 all clinical questions could be answered). The median DLP was 5.2 mGy*cm (IQR 3.5-7.8) leading to a median ED of 0.20 mSv (IQR 0.14-0.30). On average the acquired images scored 13.3 ± 2.1 (SD) out of a maximum 15 points with an intraclass correlation coefficient (ICC) of 0.94. All acquired series were able to fully answer all clinical questions scoring maximum points (ICC 1.0). Dual source high pitch CT protocols combined with custom contrast agent injection protocols in pediatric patients with CHD delivered sufficiently high diagnostic imaging quality combined with low submilisievert radiation doses. Prospective high pitch imaging is a reliable method for depiction of cardiac anatomy even in very young pediatric CHD patients with elevated heart rates.


Asunto(s)
Cardiopatías Congénitas , Tomografía Computarizada por Rayos X , Anciano de 80 o más Años , Niño , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Lactante , Estudios Prospectivos , Dosis de Radiación , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
16.
Rofo ; 194(9): 1003-1011, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35272355

RESUMEN

PURPOSE: To evaluate cardiac MRI characteristics in patients with suspected hypersensitivity myocarditis following mRNA COVID-19 vaccination. MATERIALS AND METHODS: Patients clinically suspected of acute myocarditis after COVID-19 vaccination were retrospectively analyzed and compared against a healthy control group. Cardiac MRI protocol included parameters such as T1 and T2 relaxation times, extracellular volume (ECV), T2 signal intensity ratio, and late gadolinium enhancement (LGE). Lymph node size was assessed in the patient group on the injection side. Student t-test, analyses of variance (ANOVA) with Tukey post-hoc test, and χ2 test were used for statistical analysis. RESULTS: 20 patients with clinically suspected post-vaccine myocarditis (28 ±â€Š12 years; 12 men) and 40 controls (31 ±â€Š11 years; 25 men) were evaluated. According to the 2018 Lake Louise criteria (LLC), patients with clinically suspected myocarditis were further subdivided into an LLC-positive group (n = 9) and an LLC-negative group (n = 11). The mean time of symptom onset after vaccination was 1.1 ±â€Š1.2 days (LLC-positive) and 6.5 ±â€Š9.2 days (LLC-negative). Group differences in inflammatory variables between myocarditis patients and control subjects were more pronounced in the LLC-positive group (e. g., T1 relaxation time: 1041 ±â€Š61 ms [LLC positive] vs. 1008 ±â€Š79 ms [LLC-negative] vs. 970 ±â€Š25 ms [control]; p <.001; or T2 signal intensity ratio 2.0 ±â€Š0.3 vs. 1.6 ±â€Š0.3 [LLC-negative] and vs. 1.6 ±â€Š0.3 [control], p = .012). LLC-positive patients were significantly faster in receiving an MRI after initial symptom onset (8.8 ±â€Š6.1 days vs. 52.7 ±â€Š33.4 days; p = .001) and had higher troponin T levels (3938 ±â€Š5850 ng/l vs. 9 ±â€Š11 ng/l; p <.001). LGE lesions were predominantly located at the subepicardium of the lateral wall. Axillary lymphadenopathy was more frequent in the LLC-positive group compared to the LLC-negative group (8/9 [89 %] vs. 0/11 [0 %], p < 0.001). CONCLUSION: Vaccine-induced myocarditis should be considered in patients with acute symptom onset after mRNA vaccination, especially if elevated serum troponin T is observed. Imaging findings of vaccine-induced myocarditis are similar to virus-induced myocarditis, allowing for the use of the Lake Louise Criteria for diagnostic purposes. KEY POINTS: · Vaccine-induced hypersensitivity myocarditis can be confirmed with cardiac MRI. · Especially patients with sudden onset of symptoms and elevated serum troponin T had positive cardiac MRI findings. · Cardiac MRI characteristics of vaccine-induced myocarditis are similar to those in virus-induced myocarditis. CITATION FORMAT: · Kravchenko D, Isaak A, Mesropyan N et al. Cardiac MRI in Suspected Acute Myocarditis After COVID-19 mRNA Vaccination. Fortschr Röntgenstr 2022; 194: 1003 - 1011.


Asunto(s)
COVID-19 , Miocarditis , Adolescente , Adulto , Vacunas contra la COVID-19 , Medios de Contraste , Femenino , Gadolinio , Humanos , Imagen por Resonancia Magnética , Masculino , Valor Predictivo de las Pruebas , ARN Mensajero , Estudios Retrospectivos , Troponina T , Vacunación , Adulto Joven
18.
Clin Rheumatol ; 41(1): 223-233, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34626261

RESUMEN

OBJECTIVES: To analyse the diagnostic impact of dual energy computed tomography (DECT) in acute gout flares and acute calcium pyrophosphate (CPP) crystal arthritis when compared to the gold standard of arthrocentesis with compensated polarised light microscopy. Microscopy results were also compared to musculoskeletal ultrasound (MUS), conventional radiographs, and the suspected clinical diagnosis (SCD). METHODS: Thirty-six patients with a suspected gout flare (n = 24) or acute CPP crystal arthritis (n = 11, n = 1 suffered from neither) who received a DECT and underwent arthrocentesis were included. Two independent readers assessed DECT images for signs of monosodium urate crystals or calcium pyrophosphate deposition. RESULTS: Sensitivity of DECT for gout was 63% (95% CI 0.41-0.81) with a specificity of 92% (0.41-0.81) while sensitivity and specificity for acute CPP arthritis were 55% (0.23-0.83) and 92% (0.74-0.99), respectively. MUS had the highest sensitivity of all imaging modalities with 92% (0.73-0.99) and a specificity of 83% (0.52-0.98) for gout, while sensitivity and specificity for acute CPP crystal arthritis were 91% (0.59-1.00) and 92% (0.74-0.99), respectively. CONCLUSION: DECT is an adequate non-invasive diagnostic tool for acute gout flares but might have a lower sensitivity than described by previous studies. Both MUS and SCD had higher sensitivities than DECT for acute gout flares and acute CPP crystal arthritis.


Asunto(s)
Artritis Gotosa , Gota , Pirofosfato de Calcio , Gota/diagnóstico por imagen , Humanos , Brote de los Síntomas , Tomografía Computarizada por Rayos X
19.
Front Med (Lausanne) ; 8: 758255, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34901071

RESUMEN

Background: Despite ultrasound being an inherent part of medical education, only a few German medical schools have established a comprehensive ultrasound curriculum. This study aimed to explore medical students' perspectives on ultrasound in medical education (USMed). Results: Between January 1st, 2019 und June 30th, 2019, an online survey was conducted among German medical students via the students' associations and their respective teaching facilities. The survey consisted of 17 items regarding USMed. Statements were rated on a 4-point Likert scale for agreement. In total, 1040 students from 31 German medical faculties participated. The majority (1021, 98.2%) reported a very high to high interest in curricular USMed. Students agreed (n = 945, 90.9%) that USMed would be helpful along their entire course of medical studies. Considering the best starting time for USMed, the opinions of German medical students diverged: students studying in a model curriculum preferred to start in the second year (40.7%) while 49% of the students studying in a traditional curriculum preferred to start in the third year (p ≤ 0.001). An insufficient allotment of time for USMed in the planned curriculum (675, 65%) and a lack of courses run by medical faculty (305, 29.4%) were listed as perceived significant barriers to the participation in USMed. Peer teaching was regarded as an effective method in realizing USMed by 731 (70.3%) students. Conclusion: German medical students are very interested and willing to participate in USMed. There appears to be a high demand for US courses offered by medical schools.

20.
J Cardiovasc Magn Reson ; 23(1): 117, 2021 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-34689811

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance angiography (CMRA) is a non-invasive imaging modality of choice in pediatric patients with congenital heart disease (CHD). This study was aimed to evaluate the diagnostic utility of a respiratory- and electrocardiogram-gated steady-state CMRA with modified Dixon (mDixon) fat suppression technique and compressed sensing in comparison to standard first-pass CMRA in pediatric patients with CHD at 3 T. METHODS: In this retrospective single center study, pediatric CHD patients who underwent CMR with first-pass CMRA followed by mDixon steady-state CMRA at 3 T were analyzed. Image quality using a Likert scale from 5 (excellent) to 1 (non-diagnostic) and quality of fat suppression were assessed in consensus by two readers. Blood-to-tissue contrast and quantitative measurements of the thoracic vasculature were assessed separately by two readers. CMRA images were reevaluated by two readers for additional findings, which could be identified only on either one of the CMRA types. Paired Student t test, Wilcoxon test, and intraclass correlation coefficients (ICCs) were used for statistical analysis. RESULTS: 32 patients with CHD (3.3 ± 1.7 years, 13 female) were included. Overall image quality of steady-state mDixon CMRA was higher compared to first-pass CMRA (4.5 ± 0.5 vs. 3.3 ± 0.5; P < 0.001). Blood-to-tissue contrast ratio of steady-state mDixon CMRA was comparable to first-pass CMRA (7.85 ± 4.75 vs. 6.35 ± 2.23; P = 0.133). Fat suppression of steady-state mDixon CMRA was perfect in 30/32 (94%) cases. Vessel diameters were greater in first-pass CMRA compared to steady-state mDixon CMRA with the greatest differences at the level of pulmonary arteries and veins (e.g., right pulmonary artery for reader 1: 10.4 ± 2.4 vs. 9.9 ± 2.3 mm, P < 0.001). Interobserver agreement was higher for steady-state mDixon CMRA for all measurements compared to first-pass CMRA (ICCs > 0.92). In 9/32 (28%) patients, 10 additional findings were identified on mDixon steady-state CMRA (e.g., partial anomalous venous return, abnormalities of coronary arteries, subclavian artery stenosis), which were not depicted using first-pass CMRA. CONCLUSIONS: Steady-state mDixon CMRA offers a robust fat suppression, a high image quality, and diagnostic utility for the assessment of the thoracic vasculature in pediatric CHD patients.


Asunto(s)
Cardiopatías Congénitas , Angiografía por Resonancia Magnética , Niño , Medios de Contraste , Vasos Coronarios , Femenino , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Imagenología Tridimensional , Valor Predictivo de las Pruebas , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...