Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 46
1.
Cardiovasc Intervent Radiol ; 46(10): 1385-1393, 2023 Oct.
Article En | MEDLINE | ID: mdl-37700006

PURPOSE: To investigate differences in thermal sensitivity of virtual monoenergetic imaging (VMI) series generated from photon-counting detector (PCD) CT data sets, regarding their use to improve discrimination of the ablation zone during percutaneous cryoablation. MATERIALS AND METHODS: CT-guided cryoablation was performed using an ex vivo model of porcine liver on a PCD-CT system. The ablation zone was imaged continuously for 8 min by acquiring a CT scan every 5 s. Tissue temperature was measured using fiberoptic temperature probes placed parallel to the cryoprobe. CT-values and noise were measured at the tip of the temperature probes on each scan and on VMI series from 40 to 130 keV. Correlation of CT-values and temperature was assessed using linear regression analyses. RESULTS: For the whole temperature range of [- 40, + 20] °C, we observed a linear correlation between CT-values and temperature in reference 70 keV images (R2 = 0.60, p < 0.001) with a thermal sensitivity of 1.4HU/°C. For the most dynamic range of [- 15, + 20] °C, the sensitivity increased to 2.4HU/°C (R2 = 0.50, p < 0.001). Using VMI reconstructions, the thermal sensitivity increased from 1.4 HU/°C at 70 keV to 1.5, 1.7 and 2.0HU/°C at 60, 50 and 40 keV, respectively (range [- 40, + 20] °C). For [- 15, + 20]°C, the thermal sensitivity increased from 2.4HU/°C at 70 keV to 2.5, 2.6 and 2.7HU/°C at 60, 50 and 40 keV, respectively. Both CT-values and noise also increased with decreasing VMI keV-levels. CONCLUSION: During CT-guided cryoablation of porcine liver, low-keV VMI reconstructions derived from PCD-CT data sets exhibit improved thermal sensitivity being highest between + 20 and - 15 °C.


Cryosurgery , Swine , Animals , Signal-To-Noise Ratio , Tomography, X-Ray Computed/methods , Liver/diagnostic imaging , Liver/surgery , Abdomen , Retrospective Studies , Radiographic Image Interpretation, Computer-Assisted/methods
2.
CVIR Endovasc ; 6(1): 44, 2023 Aug 29.
Article En | MEDLINE | ID: mdl-37642825

PURPOSE: Aim of this study was to analyze hospitalizations due to ruptured and non-ruptured abdominal aortic aneurysms (rAAA, nrAAA) in Germany between 2005 and 2021 to determine long-term trends in treatment and the impact of the SARS-CoV-2 pandemic. MATERIALS AND METHODS: Fully anonymized data were available from the research data center (RDC) of the German Federal Statistical Office (Destatis). All German hospitalizations with the ICD-10 code "I71.3, rAAA" and "I71.4, nrAAA" in 2005 and 2010-2021 were analyzed. RESULTS: We report data of a total of 202,951 hospitalizations. The number of hospitalizations increased from 2005 to 2019 (14,075 to 16,051, + 14.0%). The rate of open repair (OR) constantly decreased, whereas the rate of endovascular aortic repair (EVAR) increased until 2019. During the pandemic, the number of hospitalizations due to nrAAA dropped from 13,887 (86.5%) in 2019 to 11,278 (85.0%) in 2021. The strongest decrease of hospitalizations for AAA was observed during the first wave of the SARS-CoV-2-pandemic in spring 2020 (-25.5%). CONCLUSION: Over the past decades, we observed an increasing number of hospitalizations due to AAA accompanied by a shift from OR to EVAR especially for nrAAA. During the lockdown measures due to the SARS-CoV-2-pandemic, a decrease in hospitalizations for nrAAA (but not for rAAA) was shown in 2020 and furthermore in 2021 with no rebound of treatment of nrAAA suggesting an accumulation of untreated AAA with a potentially increased risk of rupture.

3.
Eur J Radiol ; 165: 110946, 2023 Aug.
Article En | MEDLINE | ID: mdl-37399668

PURPOSE: To investigate the usefulness of virtual monoenergetic image (VMI) reconstructions derived from scans on a novel photon-counting detector CT (PCD-CT) for artifact reduction in patients after posterior spinal fixation. METHODS: This retrospective cohort study included 23 patients status post posterior spinal fixation. Subjects were scanned on a novel PCD-CT (NAEOTOM Alpha, Siemens Healthineers, Erlangen, Germany) as part of routine clinical care. 14 sets of VMI reconstructions were derived in 10 keV increments for the interval 60-190 keV. The mean and the standard deviation (SD) of CT-values in 12 defined locations around a pair of pedicle screws on one vertebral level and the SD of homogenous fat were measured and used to calculate an artifact index (AIx). RESULTS: Averaged over all regions, the lowest AIx was observed at VMI levels of 110 keV (32.5 (27.8-37.9)) which was significantly different from those of VMIs ≤ 90 keV (p < 0.001) or ≥160 keV (p < 0.015), respectively. Overall AIx values increased in both lower- and higher-keV levels. Regarding individual locations, either a monotonous AIx-decrease for increasing keV values or an AIx-minimum in intermediate-keV levels (100-140 keV) was found. In locations adjacent to larger metal parts, the increase of AIx values at the high-end of the keV spectrum was mainly explained by a reappearance of streak artifacts. CONCLUSION: Our findings suggest that 110 keV is the optimal VMI setting for overall artifact suppression. In specific anatomical regions, however, slight adjustments towards higher-keV levels may provide better results.


Artifacts , Tomography, X-Ray Computed , Humans , Retrospective Studies , Tomography, X-Ray Computed/methods , Spine/diagnostic imaging , Spine/surgery , Metals , Radiographic Image Interpretation, Computer-Assisted/methods , Signal-To-Noise Ratio
4.
Eur J Radiol ; 166: 110967, 2023 Sep.
Article En | MEDLINE | ID: mdl-37487433

PURPOSE: To correlate CT values of the blood pool on VNC series with serum hemoglobin values for the detection of anemia in oncologic patients undergoing contrast-enhanced PCD-CT scans. METHODS: This prospective study (NCT04989192) included consecutive oncologic patients undergoing contrast-enhanced CT on a novel PCD-CT system between 08/2021 and 01/2022. The interval between complete blood count (CBC) and CT scan acquisition had to be no more than seven days. CT-values of the blood pool were measured on 70 keV VMI series (CT-values(BP)70keV) and on VNC series (CT-values(BP)VNC) at five anatomic positions (left atrium, left ventricle, main pulmonary artery, ascending and descending aorta) and averaged per patient. Pearson correlation analyses and ROC analyses were performed to identify relations between CT-values(BP)VNC, CBC parameters, and degrees of anemia as defined by the WHO (no anemia, mild, moderate, severe anemia). RESULTS: A total of 329 patients (age 68 ± 12 years; 200 men) were included. CT-values(BP)VNC showed a strong linear correlation to serum hemoglobin (r2 = 0.80, p <.001) and hematocrit (r2 = 0.76, p <.001) and were significantly different between anemia subgroups in both women and men (ΔHU: 3.5-11.4; all p <.01). ROC analyses yielded high diagnostic performance for the identification of patients without anemia, patients without and with mild anemia, and patients with severe anemia using gender-specific cutoffs for CT-value(BP)VNC (all AUC's > 0.90). CONCLUSIONS: The spectral information inherent in PCD-CT acquisitions allows the detection and quantification of anemia in contrast-enhanced CT acquisitions of oncologic patients with high diagnostic accuracy.


Radiographic Image Interpretation, Computer-Assisted , Tomography, X-Ray Computed , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Hemoglobins , Prospective Studies , ROC Curve , Proof of Concept Study
5.
Invest Radiol ; 58(9): 691-696, 2023 09 01.
Article En | MEDLINE | ID: mdl-36897803

OBJECTIVE: The aim of this study was to compare the effectiveness of common strategies for artifact reduction of dental material in photon-counting detector computed tomography data sets. MATERIALS AND METHODS: Patients with dental material who underwent clinically indicated CT of the neck were enrolled. Image series were reconstructed using a standard and sharp kernel, with and without iterative metal artifact reduction (IMAR) (Qr40, Qr40 IMAR , Qr60, Qr60 IMAR ) at different virtual monoenergetic imaging (VMI) levels (40-190 keV). On representative slice positions with and without dental artifacts, mean and standard deviation of CT values were measured in all series at identical locations. The mean absolute error of CT values ( ) and the artifact index (AIX) were calculated and analyzed focusing on 3 main comparisons: ( a ) different VMI levels versus 70 keV, ( b ) standard versus sharp kernel, and ( c ) nonuse or use of IMAR reconstruction. The Wilcoxon test was used to assess differences for nonparametric data. RESULTS: The final cohort comprised 50 patients. Artifact measures decreased for VMI levels >70 keV, yet only significantly so for reconstructions using IMAR (maximum reduction, 25%). The higher image noise of the sharp versus standard kernel is reflected in higher AIX values and is more pronounced in IMAR series (maximum increase, 38%). The most profound artifact reduction was observed for IMAR reconstructions (maximum reduction : 84%; AIX: 90%). CONCLUSIONS: Metal artifacts caused by large amounts of dental material can be substantially reduced by IMAR, regardless of kernel choice or VMI settings. Increasing the keV level of VMI series, on the other hand, only slightly reduces dental artifacts; this effect, however, is additive to the benefit conferred by IMAR reconstructions.


Artifacts , Metals , Humans , Tomography, X-Ray Computed/methods , Neck , Dental Materials , Algorithms
6.
Eur Radiol ; 33(4): 2450-2460, 2023 Apr.
Article En | MEDLINE | ID: mdl-36462042

OBJECTIVES: To assess epicardial adipose tissue (EAT) volume and attenuation of different virtual non-contrast (VNC) reconstructions derived from coronary CTA (CCTA) datasets of a photon-counting detector (PCD) CT-system to replace true non-contrast (TNC) series. METHODS: Consecutive patients (n = 42) with clinically indicated CCTA and coronary TNC were included. Two VNC series were reconstructed, using a conventional (VNCConv) and a novel calcium-preserving (VNCPC) algorithm. EAT was segmented on TNC, VNCConv, VNCPC, and CCTA (CTA-30) series using thresholds of -190 to -30 HU and an additional segmentation on the CCTA series with an upper threshold of 0 HU (CTA0). EAT volumes and their histograms were assessed for each series. Linear regression was used to correlate EAT volumes and the Euclidian distance for histograms. The paired t-test and the Wilcoxon signed-rank test were used to assess differences for parametric and non-parametric data. RESULTS: EAT volumes from VNC and CCTA series showed significant differences compared to TNC (all p < .05), but excellent correlation (all R2 > 0.9). Measurements on the novel VNCPC series showed the best correlation (R2 = 0.99) and only minor absolute differences compared to TNC values. Mean volume differences were -12%, -3%, -13%, and +10% for VNCConv, VNCPC, CTA-30, and CTA0 compared to TNC. Distribution of CT values on VNCPC showed less difference to TNC than on VNCConv (mean attenuation difference +7% vs. +2%; Euclidean distance of histograms 0.029 vs. 0.016). CONCLUSIONS: VNCPC-reconstructions of PCD-CCTA datasets can be used to reliably assess EAT volume with a high accuracy and only minor differences in CT values compared to TNC. Substitution of TNC would significantly decrease patient's radiation dose. KEY POINTS: • Measurement of epicardial adipose tissue (EAT) volume and attenuation are feasible on virtual non-contrast (VNC) series with excellent correlation to true non-contrast series (all R2>0.9). • Differences in VNC algorithms have a significant impact on EAT volume and CT attenuation values. • A novel VNC algorithm (VNCPC) enables reliable assessment of EAT volume and attenuation with superior accuracy compared to measurements on conventional VNC- and CCTA-series.


Angiography , Tomography, X-Ray Computed , Humans , Tomography, X-Ray Computed/methods , Reproducibility of Results , Photons , Adipose Tissue/diagnostic imaging , Retrospective Studies
8.
Dtsch Arztebl Int ; 119(37): 611-618, 2022 09 16.
Article En | MEDLINE | ID: mdl-35734915

BACKGROUND: Studies from Denmark and the USA have shown differences in treatment outcomes for patients with peripheral arterial occlusive disease (PAOD) between hospitals of different size and certification status. For Germany, it is not known whether certification as a specialist center for vascular diseases or hospital size is associated with differences in the primary treatment outcome. METHODS: Using data from the German Federal Statistical Office, all hospitalizations due to PAOD of Fontaine stage IIb or higher were included in our study and the hospitals were classified according to their size and certification status. PAOD stage, age, sex, and comorbidities were documented for each hospitalization. Univariate and multivariate logistic regressions were performed to identify independent variables that predict various treatment endpoints. RESULTS: A total of 558 785 hospitalizations were included for analysis, of which 29% were in hospitals with certified vascular centers. In multivariate analysis, admissions to certified hospitals were associated with lower rates of major amputation (odds ratio [OR] 0.95, 95% confidence interval [0.92; 0.98], p = 0.003) and higher rates of minor amputation (OR 1.04 [1.01; 1.06], p = 0.004) with no difference observed in mortality (OR 0.99 [0.96; 1.03], p = 0.791). Admissions to larger hospitals were associated with more comorbidities, longer hospital stays, and higher rates of mortality and amputations. CONCLUSION: Treatments in certified hospitals are associated with fewer major and more minor amputations. This may reflect intensification of therapy targeting preservation of functional limbs.


Arterial Occlusive Diseases , Peripheral Arterial Disease , Humans , Arterial Occlusive Diseases/epidemiology , Arterial Occlusive Diseases/therapy , Arterial Occlusive Diseases/complications , Peripheral Arterial Disease/epidemiology , Peripheral Arterial Disease/therapy , Amputation, Surgical , Treatment Outcome , Hospitals , Retrospective Studies , Risk Factors
9.
Diagnostics (Basel) ; 12(5)2022 May 14.
Article En | MEDLINE | ID: mdl-35626387

In dual-energy CT datasets, the conspicuity of liver metastases can be enhanced by virtual monoenergetic imaging (VMI) reconstructions at low keV levels. Our study investigated whether this effect can be reproduced in photon-counting detector CT (PCD-CT) datasets. We analyzed 100 patients with liver metastases who had undergone contrast-enhanced CT of the abdomen on a PCD-CT (n = 50) or energy-integrating detector CT (EID-CT, single-energy mode, n = 50). PCD-VMI-reconstructions were performed at various keV levels. Identical regions of interest were positioned in metastases, normal liver, and other defined locations assessing image noise, tumor-to-liver ratio (TLR), and contrast-to-noise ratio (CNR). Patients were compared inter-individually. Subgroup analyses were performed according to BMI. On the PCD-CT, noise and CNR peaked at the low end of the keV spectrum. In comparison with the EID-CT, PCD-VMI-reconstructions exhibited lower image noise (at 70 keV) but higher CNR (for ≤70 keV), despite similar CTDIs. Comparing high- and low-BMI patients, CTDI-upregulation was more modest for the PCD-CT but still resulted in similar noise levels and preserved CNR, unlike the EID-CT. In conclusion, PCD-CT VMIs in oncologic patients demonstrated reduced image noise-compared to a standard EID-CT-and improved conspicuity of hypovascularized liver metastases at low keV values. Patients with higher BMIs especially benefited from constant image noise and preservation of lesion conspicuity, despite a more moderate upregulation of CTDI.

10.
Eur Radiol ; 32(9): 6008-6016, 2022 Sep.
Article En | MEDLINE | ID: mdl-35359166

OBJECTIVES: To evaluate feasibility and diagnostic performance of coronary CT angiography (CCTA)-derived fractional flow reserve (CT-FFR) for detection of significant coronary artery disease (CAD) and decision-making in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) to potentially avoid additional pre-TAVR invasive coronary angiography (ICA). METHODS: Consecutive patients with severe AS (n = 95, 78.6 ± 8.8 years, 53% female) undergoing pre-procedural TAVR-CT followed by ICA with quantitative coronary angiography were retrospectively analyzed. CCTA datasets were evaluated using CAD Reporting and Data System (CAD-RADS) classification. CT-FFR measurements were computed using an on-site machine-learning algorithm. A combined algorithm was developed for decision-making to determine if ICA is needed based on pre-TAVR CCTA: [1] all patients with CAD-RADS ≥ 4 are referred for ICA; [2] patients with CAD-RADS 2 and 3 are evaluated utilizing CT-FFR and sent to ICA if CT-FFR ≤ 0.80; [3] patients with CAD-RADS < 2 or CAD-RADS 2-3 and normal CT-FFR are not referred for ICA. RESULTS: Twelve patients (13%) had significant CAD (≥ 70% stenosis) on ICA and were treated with PCI. Twenty-eight patients (30%) showed CT-FFR ≤ 0.80 and 24 (86%) of those were reported to have a maximum stenosis ≥ 50% during ICA. Using the proposed algorithm, significant CAD could be identified with a sensitivity, specificity, and positive and negative predictive value of 100%, 78%, 40%, and 100%, respectively, potentially decreasing the number of necessary ICAs by 65 (68%). CONCLUSION: Combination of CT-FFR and CAD-RADS is able to identify significant CAD pre-TAVR and bears potential to significantly reduce the number of needed ICAs. KEY POINTS: • Coronary CT angiography-derived fractional flow reserve (CT-FFR) using machine learning together with the CAD Reporting and Data System (CAD-RADS) classification safely identifies significant coronary artery disease based on quantitative coronary angiography in patients prior to transcatheter aortic valve replacement. • The combination of CT-FFR and CAD-RADS enables decision-making and bears the potential to significantly reduce the number of needed invasive coronary angiographies.


Aortic Valve Stenosis , Coronary Artery Disease , Coronary Stenosis , Fractional Flow Reserve, Myocardial , Percutaneous Coronary Intervention , Transcatheter Aortic Valve Replacement , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Computed Tomography Angiography/methods , Constriction, Pathologic , Coronary Angiography/methods , Coronary Artery Disease/diagnosis , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/surgery , Female , Humans , Machine Learning , Male , Predictive Value of Tests , Retrospective Studies , Tomography, X-Ray Computed
11.
Cardiovasc Intervent Radiol ; 45(10): 1472-1482, 2022 Oct.
Article En | MEDLINE | ID: mdl-35428938

OBJECTIVE: To analyze trends and differences of endovascular, surgical and hybrid revascularization approaches and the impact of comorbidity on characteristics, costs, and outcome of in-patients with peripheral artery disease (PAD) of the lower extremity. METHODS: Analyzing data provided by the Research Data Center of the German Federal Statistical Office, we included all hospitalizations due to PAD Fontaine IIb (Rutherford 2-3) or higher in Germany between 2009-2011 and 2016-2018. According to the individually performed procedures encoded by the Operation and Procedure Classification System, we divided hospitalizations by revascularization procedures into sole endovascular, sole surgical, hybrid, two-step and no revascularization. Patient's comorbidity was assessed using the linear van Walraven comorbidity score (vWs). RESULTS: 1,067,671 hospitalizations (mean age 71.3 ± 11.1 years; 60.1% male) were analyzed. Between 2009-2011 and 2016-2018, reimbursement costs rose by 28.0% from €2.72 billion (€5,350/case) to €3.49 billion (€6,238/case). The share of hospitalizations with any revascularization increased by 8.9% (67.7-73.7%) driven by an increase in two-step (+ 63.3%), hybrid (+ 58.2%) and sole endovascular revascularizations (+ 32.6%), while sole surgical approaches declined (- 18.2%). Hospitalizations of more comorbid patients (vWs ≥ 20) rose by 46.8% (21,444-31,478 cases), showed an overproportionate increase in costs of 124.6% (+ €1,750/case) and were associated with more individual procedures (+ 90.6%). CONCLUSIONS: In-patient treatment of PAD patients shows increasing numbers of hybrid and sole endovascular revascularizations and more patients with higher comorbidity, while sole surgical interventions and in-hospital mortality decrease. Consequently, associated costs are surging especially in more comorbid patients due to an increasing number of performed procedures and escalation of therapy.


Endovascular Procedures , Peripheral Arterial Disease , Aged , Aged, 80 and over , Amputation, Surgical , Comorbidity , Endovascular Procedures/adverse effects , Female , Germany/epidemiology , Hospitalization , Humans , Lower Extremity/blood supply , Male , Middle Aged , Peripheral Arterial Disease/epidemiology , Peripheral Arterial Disease/surgery , Risk Factors , Time Factors , Treatment Outcome
12.
J Clin Med ; 11(7)2022 Apr 03.
Article En | MEDLINE | ID: mdl-35407616

Patients with peripheral artery disease (PAD) belong to a vulnerable population with relevant comorbidity. Appropriate care and timely treatment are imperative, but not readily assured in the current pandemic. What impact did the first wave have on in-hospital treatment in Germany? Nationwide healthcare remuneration data for inpatient care of the years 2019 and 2020 were used to compare demographic baseline data including the assessment of comorbidity (van Walraven score), as well as the encoded treatments. A direct comparison was made between the first wave of infections in 2020 and the reference period in 2019. The number of inpatient admissions decreased by 10.9%, with a relative increase in hospitalizations due to PAD Fontaine IV (+13.6%). Baseline demographics and comorbidity showed no relevant differences. The proportion of emergency admissions increased from 23.4% to 28.3% during the first wave to the reference period in 2019, and in-hospital mortality increased by 21.9% from 2.5% to 3.1%. Minor and major amputations increased by 24.5% and 18.5%. Endovascular and combined surgical/endovascular treatment strategies increased for all stages. Already in the first, comparatively mild wave of the pandemic, significantly fewer patients with predominantly higher-grade PAD stages were treated as inpatients. Consecutively, in-hospital mortality and amputation rates increased.

13.
Diagnostics (Basel) ; 12(3)2022 Feb 22.
Article En | MEDLINE | ID: mdl-35328111

The purpose of this study was to evaluate virtual-non contrast reconstructions of Photon-Counting Detector (PCD) CT-angiography datasets using a novel calcium-preserving algorithm (VNCPC) vs. the standard algorithm (VNCConv) for their potential to replace unenhanced acquisitions (TNC) in patients after endovascular aneurysm repair (EVAR). 20 EVAR patients who had undergone CTA (unenhanced and arterial phase) on a novel PCD-CT were included. VNCConv- and VNCPC-series were derived from CTA-datasets and intraluminal signal and noise compared. Three readers evaluated image quality, contrast removal, and removal of calcifications/stent parts and assessed all VNC-series for their suitability to replace TNC-series. Image noise was higher in VNC- than in TNC-series (18.6 ± 5.3 HU, 16.7 ± 7.1 HU, and 14.9 ± 7.1 HU for VNCConv-, VNCPC-, and TNC-series, p = 0.006). Subjective image quality was substantially higher in VNCPC- than VNCConv-series (4.2 ± 0.9 vs. 2.5 ± 0.6; p < 0.001). Aortic contrast removal was complete in all VNC-series. Unlike in VNCConv-reconstructions, only minuscule parts of stents or calcifications were erroneously subtracted in VNCPC-reconstructions. Readers considered 95% of VNCPC-series fully or mostly suited to replace TNC-series; for VNCConv-reconstructions, however, only 75% were considered mostly (and none fully) suited for TNC-replacement. VNCPC-reconstructions of PCD-CT-angiography datasets have excellent image quality with complete contrast removal and only minimal erroneous subtractions of stent parts/calcifications. They could replace TNC-series in almost all cases.

14.
Invest Radiol ; 57(8): 536-543, 2022 08 01.
Article En | MEDLINE | ID: mdl-35318969

PURPOSE: The aim of this study was to evaluate coronary computed tomography angiography (CCTA)-based in vitro and in vivo coronary artery calcium scoring (CACS) using a novel virtual noniodine reconstruction (PureCalcium) on a clinical first-generation photon-counting detector-computed tomography system compared with virtual noncontrast (VNC) reconstructions and true noncontrast (TNC) acquisitions. MATERIALS AND METHODS: Although CACS and CCTA are well-established techniques for the assessment of coronary artery disease, they are complementary acquisitions, translating into increased scan time and patient radiation dose. Hence, accurate CACS derived from a single CCTA acquisition would be highly desirable. In this study, CACS based on PureCalcium, VNC, and TNC, reconstructions was evaluated in a CACS phantom and in 67 patients (70 [59/80] years, 58.2% male) undergoing CCTA on a first-generation photon counting detector-computed tomography system. Coronary artery calcium scores were quantified for the 3 reconstructions and compared using Wilcoxon test. Agreement was evaluated by Pearson and Spearman correlation and Bland-Altman analysis. Classification of coronary artery calcium score categories (0, 1-10, 11-100, 101-400, and >400) was compared using Cohen κ . RESULTS: Phantom studies demonstrated strong agreement between CACS PureCalcium and CACS TNC (60.7 ± 90.6 vs 67.3 ± 88.3, P = 0.01, r = 0.98, intraclass correlation [ICC] = 0.98; mean bias, 6.6; limits of agreement [LoA], -39.8/26.6), whereas CACS VNC showed a significant underestimation (42.4 ± 75.3 vs 67.3 ± 88.3, P < 0.001, r = 0.94, ICC = 0.89; mean bias, 24.9; LoA, -87.1/37.2). In vivo comparison confirmed a high correlation but revealed an underestimation of CACS PureCalcium (169.3 [0.7/969.4] vs 232.2 [26.5/1112.2], P < 0.001, r = 0.97, ICC = 0.98; mean bias, -113.5; LoA, -470.2/243.2). In comparison, CACS VNC showed a similarly high correlation, but a substantially larger underestimation (24.3 [0/272.3] vs 232.2 [26.5/1112.2], P < 0.001, r = 0.97, ICC = 0.54; mean bias, -551.6; LoA, -2037.5/934.4). CACS PureCalcium showed superior agreement of CACS classification ( κ = 0.88) than CACS VNC ( κ = 0.60). CONCLUSIONS: The accuracy of CACS quantification and classification based on PureCalcium reconstructions of CCTA outperforms CACS derived from VNC reconstructions.


Computed Tomography Angiography , Coronary Artery Disease , Algorithms , Calcium , Computed Tomography Angiography/methods , Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Female , Humans , Male , Tomography, X-Ray Computed/methods
15.
Eur J Radiol ; 148: 110181, 2022 Mar.
Article En | MEDLINE | ID: mdl-35121331

PURPOSE: To analyze the quantitative and qualitative image quality of low-dose CT scans of the abdomen on a novel photon-counting detector CT (PCD-CT) in comparison with a traditional energy-integrating detector CT (EID-CT). METHODS: Consecutive patients with clinically indicated low-dose CT were scanned on a PCD-CT and compared with a BMI-matched EID-CT-cohort scanned during the same timeframe. Radiation dose, image noise, and signal-to-noise ratio (SNR) were measured for each patient. Furthermore, image quality and conspicuity of abdominal structures (adrenal glands, mesenteric vessels, ureters, and renal pelvis) were assessed on 5-point Likert-scales (1 = very poor quality/not detectable; 5 = excellent quality/differentiability). RESULTS: Twenty patients (mean age 46.2 [range: 19-77]; 13 men) were included. Image noise was significantly lower (24.9 ± 3.3 vs. 31.4 ± 5.6 SD HU, p < 0.001) and SNR significantly higher (2.1 ± 0.3 vs. 1.5 ± 0.4; p < 0.001) on the PCD-CT. Subjective image quality was substantially higher (4.0 ± 0.3 vs. 3.1 ± 0.6; p < 0.001) and conspicuity better for the renal pelvis, ureters, and mesenteric vessels on the PCD-CT. There was no significant difference in the conspicuity of the adrenal glands. With increasing BMI (1st-4th BMI quartile), noise increased, and SNR decreased more strongly on the EID-CT than on the PCD-CT (ΔNoise: 39% vs. 2%, ΔSNR: -33% vs. -7% for EID-CT vs. PCD-CT, respectively) while radiation dose increased comparably (70 vs. 59%). CONCLUSIONS: Low-dose CT scans of the abdomen performed on a novel PCD-CT exhibit reduced noise, higher SNR, increased subjective image quality, and superior conspicuity of abdominal fine structures compared to scans in comparable patients on an EID-CT.


Photons , Tomography, X-Ray Computed , Abdomen/diagnostic imaging , Humans , Male , Middle Aged , Phantoms, Imaging , Radiation Dosage , Signal-To-Noise Ratio , Tomography, X-Ray Computed/methods
16.
Eur Radiol ; 32(3): 1697-1708, 2022 Mar.
Article En | MEDLINE | ID: mdl-34647176

OBJECTIVES: To analyze trends of in-hospital treatment of patients admitted due to peripheral artery disease (PAD) from 2009 to 2018 with special focus on comorbidities, revascularization procedures, resulting costs, and outcome. METHODS: Using data from the research data center of the German Federal Statistical Office, we included all hospitalizations due to PAD Fontaine stage IIb or higher from 2009 to 2018. To analyze comorbidities, Elixhauser diagnostic groups and linear van Walraven score (vWS) were assessed. RESULTS: A total of 1.8 million hospitalizations resulting in €10.3 billion in reimbursement costs were included. From 2009 to 2018, the absolute number of hospitalizations due to PAD increased by 13.3% (163,547 to 185,352). The average cost per hospitalization increased by 20.8% from €5,261 to €6,356. The overall in-hospital mortality decreased from 3.1 to 2.6%. Median vWS of all PAD cases increased by 3 points (2 to 5). The number of percutaneous transluminal angioplasties (PTA) increased by 43.9% while some surgical procedures such as bypasses and embolectomies decreased by 30.8% and 6.8%, respectively. Many revascularization procedures showed a disproportionate increase of those performed in vessels below the knee for example in PTA (+ 68.5%) or in endarterectomies (+ 38.8%). CONCLUSIONS: This decade-long nationwide analysis shows a rising number of hospitalizations due to PAD with more comorbid patients resulting in increasing reimbursement costs. Interventions are shifting from surgical to endovascular approaches with a notable trend towards interventions in smaller vessels below the knee. KEY POINTS: • The number of hospitalizations due to peripheral artery disease is rising and it is associated with increasing reimbursement costs. • Admitted patients are older and show an increasing number of comorbidities while overall in-hospital mortality is decreasing. • Revascularization procedures are shifting from surgical to endovascular approaches and show a trend towards intervention in smaller vessels below the knee. • Major amputations are decreasing while the number of minor amputations is increasing.


Endovascular Procedures , Peripheral Arterial Disease , Delivery of Health Care , Hospitalization , Humans , Peripheral Arterial Disease/epidemiology , Peripheral Arterial Disease/therapy , Retrospective Studies , Risk Factors , Treatment Outcome
17.
Eur Radiol ; 32(5): 2930-2936, 2022 May.
Article En | MEDLINE | ID: mdl-34936011

OBJECTIVES: Photon-counting detector CT (PCD-CT) promises a leap in spatial resolution due to smaller detector pixel sizes than implemented in energy-integrating detector CTs (EID-CT). Our objective was to compare the visualization of smallest bone details between PCD-CT and EID-CT using a mouse as a specimen. MATERIALS AND METHODS: Two euthanized mice were scanned at a 20-slice EID-CT and a dual-source PCD-CT in single-pixel mode at various CTDIVol values. Image noise and signal-to-noise ratio (SNR) were evaluated using repeated ROI measurements. Edge sharpness of bones was compared by the maximal slope within CT value plots along sampling lines intersecting predefined bones of the spine. Two readers evaluated bone detail visualization at four regions of the spine on a three-point Likert scale at various CTDIVol's. Two radiologists selected the series with better detail visualization among each of 20 SNR-matched pairs of EID-CT and PCD-CT series. RESULTS: In CTDIVol-matched scans, PCD-CT series showed significantly lower image noise (NoiseCTDI=5 mGy: 16.27 ± 1.39 vs. 23.46 ± 0.96 HU, p < 0.01), higher SNR (SNRCTDI=5 mGy: 20.57 ± 1.89 vs. 14.00 ± 0.66, p < 0.01), and higher edge sharpness (Edge Slopelumbar spine: 981 ± 160 vs. 608 ± 146 HU/mm, p < 0.01) than EID-CT series. Two radiologists considered the delineation of bone details as feasible at consistently lower CTDIVol values at PCD-CT than at EID-CT. In comparison of SNR-matched reconstructions, PCD-CT series were still considered superior in almost all cases. CONCLUSIONS: In this head-to-head comparison, PCD-CT showed superior objective and subjective image quality characteristics over EID-CT for the delineation of tiniest bone details. Even in SNR-matched pairs (acquired at different CTDIVol's), PCD-CT was strongly preferred by radiologists. KEY POINTS: • In dose-matched scans, photon-counting detector CT series showed significantly less image noise, higher signal-to-noise ratio, and higher edge sharpness than energy-integrating detector CT series. • Human observers considered the delineation of tiny bone details as feasible at much lower dose levels in photon-counting detector CT than in energy-integrating detector CT. • In direct comparison of series matched for signal-to-noise ratio, photon-counting detector CT series were considered superior in almost all cases.


Photons , Tomography, X-Ray Computed , Humans , Phantoms, Imaging , Signal-To-Noise Ratio , Tomography Scanners, X-Ray Computed , Tomography, X-Ray Computed/methods
18.
Eur J Radiol ; 137: 109578, 2021 Apr.
Article En | MEDLINE | ID: mdl-33561627

PURPOSE: To address the disagreement about the need for splenic artery embolization (SAE) in medium grade blunt splenic trauma this retrospective study evaluates the clinical outcome of non-operative management (NOM) and the possible impact of a more liberal indication for primary SAE. METHOD: From 01/2010 to 12/2019 186 patients presented with splenic injury on computed tomography (CT) after blunt abdominal trauma. The extent of splenic injuries according to Marmery, vascular pathologies, active bleeding as well as clinical and laboratory parameters were recorded and analyzed with regard to the success rates of NOM and SAE. Procedural complications and clinical outcome were noted. The number needed to treat (NNT) was determined for a possible extension of the indication for SAE to grade 3 injuries. RESULTS: Of 186 patients 126 were managed non-operatively, 47 underwent primary SAE and twelve splenectomy. NOM was successful in 119/126 (94 %) patients. Conversion rate was significantly higher in patients with active bleeding or vascular pathology. Patients with failed NOM had a significantly greater decrease in haemoglobin and haematocrit levels. Primary SAE was successful in 45/47 (96 %) cases. Major complications occurred in four cases (9%), all managed without sequela. The NNT in grade 3 splenic injuries equals 13. CONCLUSIONS: NOM of low to medium-grade blunt splenic trauma has a low failure rate. Presence of active haemorrhage is the most important predictor for failure of NOM. SAE should be reserved for high-grade injuries and visible vascular pathology or active bleeding to avoid a disproportionate increase in the NNT.


Abdominal Injuries , Embolization, Therapeutic , Wounds, Nonpenetrating , Humans , Injury Severity Score , Retrospective Studies , Splenic Artery/diagnostic imaging , Treatment Outcome , Wounds, Nonpenetrating/diagnostic imaging , Wounds, Nonpenetrating/therapy
19.
Ann Nucl Med ; 29(6): 528-34, 2015 Jul.
Article En | MEDLINE | ID: mdl-25939639

PURPOSE: To evaluate the utility of attenuation correction (AC) of V/P SPECT images for patients with pulmonary emphysema. MATERIALS AND METHODS: Twenty-one patients (mean age 67.6 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. AC/non-AC V/P SPECT images were compared visually and semiquantitatively. Visual comparison of AC/non-AC images was based on a 5-point likert scale. Semiquantitative comparison assessed absolute counts per lung (aCpLu) and lung lobe (aCpLo) for AC/non-AC images using software-based analysis; percentage counts (PC = (aCpLo/aCpLu) × 100) were calculated. Correlation between AC/non-AC V/P SPECT images was analyzed using Spearman's rho correlation coefficient; differences were tested for significance with the Wilcoxon rank sum test. RESULTS: Visual analysis revealed high conformity for AC and non-AC V/P SPECT images. Semiquantitative analysis of PC in AC/non-AC images had an excellent correlation and showed no significant differences in perfusion (ρ = 0.986) or ventilation (ρ = 0.979, p = 0.809) SPECT/CT images. CONCLUSION: AC of V/P SPECT images for lung lobe-based function imaging in patients with pulmonary emphysema do not improve visual or semiquantitative image analysis.


Multimodal Imaging/methods , Perfusion Imaging/methods , Pulmonary Emphysema/diagnostic imaging , Tomography, Emission-Computed, Single-Photon/methods , Tomography, X-Ray Computed/methods , Aged , Female , Humans , Lung/diagnostic imaging , Male , Middle Aged , Respiration , Retrospective Studies
20.
Cardiovasc Intervent Radiol ; 38(3): 613-22, 2015 Jun.
Article En | MEDLINE | ID: mdl-25148920

PURPOSE: Evaluation of patient radiation exposure during uterine artery embolization (UAE) and literature review to identify techniques minimizing required dose. METHODS: A total of 224 of all included 286 (78 %) women underwent UAE according to a standard UAE-protocol (bilateral UAE from unilateral approach using a Rösch inferior mesenteric and a microcatheter, no aortography, no ovarian artery catheterization or embolization) and were analyzed for radiation exposure. Treatment was performed on three different generations of angiography systems: (I) new generation flat-panel detector (N = 108/151); (II) classical image amplifier and pulsed fluoroscopy (N = 79/98); (III) classical image amplifier and continuous fluoroscopy (N = 37/37). Fluoroscopy time (FT) and dose-area product (DAP) were documented. Whenever possible, the following dose-saving measures were applied: optimized source-object, source-image, and object-image distances, pulsed fluoroscopy, angiographic runs in posterior-anterior direction with 0.5 frames per second, no magnification, tight collimation, no additional aortography. RESULTS: In a standard bilateral UAE, the use of the new generation flat-panel detector in group I led to a significantly lower DAP of 3,156 cGy × cm(2) (544-45,980) compared with 4,000 cGy × cm(2) (1,400-13,000) in group II (P = 0.033). Both doses were significantly lower than those of group III with 8,547 cGy × cm(2) (3,324-35,729; P < 0.001). Other reasons for dose escalation were longer FT due to difficult anatomy or a large leiomyoma load, additional angiographic runs, supplementary ovarian artery embolization, and obesity. CONCLUSIONS: The use of modern angiographic units with flat panel detectors and strict application of methods of radiation reduction lead to a significantly lower radiation exposure. Target DAP for UAE should be kept below 5,000 cGy × cm(2).


Leiomyoma/therapy , Radiation Dosage , Radiation Exposure , Uterine Artery Embolization/methods , Uterine Neoplasms/therapy , Adult , Female , Fluoroscopy , Humans , Leiomyoma/diagnostic imaging , Middle Aged , Uterine Neoplasms/diagnostic imaging
...