Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
IEEE Trans Med Imaging ; 43(8): 3013-3026, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39088484

RESUMEN

Accurate motion estimation at high acceleration factors enables rapid motion-compensated reconstruction in Magnetic Resonance Imaging (MRI) without compromising the diagnostic image quality. In this work, we introduce an attention-aware deep learning-based framework that can perform non-rigid pairwise registration for fully sampled and accelerated MRI. We extract local visual representations to build similarity maps between the registered image pairs at multiple resolution levels and additionally leverage long-range contextual information using a transformer-based module to alleviate ambiguities in the presence of artifacts caused by undersampling. We combine local and global dependencies to perform simultaneous coarse and fine motion estimation. The proposed method was evaluated on in-house acquired fully sampled and accelerated data of 101 patients and 62 healthy subjects undergoing cardiac and thoracic MRI. The impact of motion estimation accuracy on the downstream task of motion-compensated reconstruction was analyzed. We demonstrate that our model derives reliable and consistent motion fields across different sampling trajectories (Cartesian and radial) and acceleration factors of up to 16x for cardiac motion and 30x for respiratory motion and achieves superior image quality in motion-compensated reconstruction qualitatively and quantitatively compared to conventional and recent deep learning-based approaches. The code is publicly available at https://github.com/lab-midas/GMARAFT.


Asunto(s)
Aprendizaje Profundo , Corazón , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Corazón/diagnóstico por imagen , Algoritmos , Artefactos , Movimiento/fisiología , Tórax/diagnóstico por imagen , Adulto
2.
Radiology ; 312(2): e233234, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39162632

RESUMEN

Background CT-derived fractional flow reserve (CT-FFR) and dynamic CT myocardial perfusion imaging enhance the specificity of coronary CT angiography (CCTA) for ruling out coronary artery disease (CAD). However, evidence on comparative diagnostic value remains scarce. Purpose To compare the diagnostic accuracy of CCTA plus CT-FFR, CCTA plus CT perfusion, and sequential CCTA plus CT-FFR and CT perfusion for detecting hemodynamically relevant CAD with that of invasive angiography. Materials and Methods This secondary analysis of a prospective study included patients with chest pain referred for invasive coronary angiography at nine centers from July 2016 to September 2019. CCTA and CT perfusion were performed with third-generation dual-source CT scanners. CT-FFR was assessed on-site. Independent core laboratories analyzed CCTA alone, CCTA plus CT perfusion, CCTA plus CT-FFR, and a sequential approach involving CCTA plus CT-FFR and CT perfusion for the presence of hemodynamically relevant stenosis. Invasive coronary angiography with invasive fractional flow reserve was the reference standard. Diagnostic accuracy metrics and the area under the receiver operating characteristic curve (AUC) were compared with the Sign test and DeLong test. Results Of the 105 participants (mean age, 64 years ± 8 [SD]; 68 male), 49 (47%) had hemodynamically relevant stenoses at invasive coronary angiography. CCTA plus CT-FFR and CCTA plus CT perfusion showed no evidence of a difference for participant-based sensitivities (90% vs 90%, P > .99), specificities (77% vs 79%, P > .99) and vessel-based AUCs (0.84 [95% CI: 0.77, 0.91] vs 0.83 [95% CI: 0.75, 0.91], P = .90). Both had higher participant-based specificity than CCTA alone (54%, both P < .001) without evidence of a difference in sensitivity between CCTA (94%) and CCTA plus CT perfusion (P = .50) or CCTA plus CT-FFR (P = .63). The sequential approach combining CCTA plus CT-FFR with CT perfusion achieved higher participant-based specificity than CCTA plus CT-FFR (88% vs 77%, P = .03) without evidence of a difference in participant-based sensitivity (88% vs 90%, P > .99) and vessel-based AUC (0.85 [95% CI: 0.77, 0.93], P = .78). Compared with CCTA plus CT perfusion, the sequential approach showed no evidence of a difference in participant-based sensitivity (P > .99), specificity (P = .06), or vessel-based AUC (P = .54). Conclusion There was no evidence of a difference in diagnostic accuracy between CCTA plus CT-FFR and CCTA plus CT perfusion for detecting hemodynamically relevant CAD. A sequential approach combining CCTA plus CT-FFR with CT perfusion led to improved participant-based specificity with no evidence of a difference in sensitivity compared with CCTA plus CT-FFR. ClinicalTrials.gov registration no.: NCT02810795 © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Sinitsyn in this issue.


Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Imagen de Perfusión Miocárdica , Humanos , Masculino , Femenino , Reserva del Flujo Fraccional Miocárdico/fisiología , Persona de Mediana Edad , Estudios Prospectivos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Anciano , Imagen de Perfusión Miocárdica/métodos , Hemodinámica/fisiología , Sensibilidad y Especificidad
3.
Artículo en Inglés | MEDLINE | ID: mdl-39115501

RESUMEN

BACKGROUND: Detecting ongoing inflammation in myocarditis patients has prognostic relevance, but there are limited data on the detection of chronic myocarditis and its differentiation from healed myocarditis. OBJECTIVES: This study sought to assess the performance of cardiac magnetic resonance (CMR) for the detection of ongoing inflammation and the discrimination of chronic myocarditis from healed myocarditis. METHODS: Consecutive patients with persistent symptoms (>30 days) suggestive of myocarditis were prospectively enrolled from a single tertiary center. All patients underwent a multiparametric 1.5-T CMR protocol including biventricular strain, T1/T2 mapping, and late gadolinium enhancement (LGE). Endomyocardial biopsy was chosen for the reference standard diagnosis. RESULTS: Among 452 consecutive patients, 103 (median age: 50 years; 66 men) had evaluable CMR and cardiopathologic reference diagnosis: 53 (51%) with chronic lymphocytic myocarditis and 50 (49%) with healed myocarditis. T2 mapping as a single parameter showed the best accuracy in detecting chronic myocarditis, if abnormal in ≥3 segments (92%; 95% CI: 85-97), and provided the best discrimination from healed myocarditis, as defined by the area under the receiver-operating characteristic curve (0.87 [95% CI: 0.79-0.93]; P < 0.001), followed by radial peak systolic strain rate of the left ventricle (0.86) and the right ventricle (0.84); T1 mapping (0.64), extracellular volume fraction (0.62), and LGE (0.57). Specificity increased when T2 mapping was combined with elevation of either troponin or C-reactive protein. CONCLUSIONS: A multiparametric CMR protocol allows detection of ongoing myocardial inflammation and discrimination of chronic myocarditis from healed myocarditis, with segmental T2 mapping and biventricular strain analysis showing higher diagnostic accuracy compared with T1 mapping, extracellular volume fraction, and LGE. The use of biomarkers (troponin or C-reactive protein) may improve specificity.

4.
J Cardiovasc Magn Reson ; : 101068, 2024 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-39079602

RESUMEN

PURPOSE: Diagnosing myocarditis relies on multimodal data including magnetic resonance imaging (MRI), clinical symptoms, and blood values. The correct interpretation and integration of MRI findings requires radiological expertise and knowledge. We aimed to investigate the performance of Generative Pre-trained Transformer 4 (GPT-4), a large language model, for report-based medical decision-making in the context of cardiac MRI for suspected myocarditis. METHODS: This retrospective study includes MRI reports from 396 patients with suspected myocarditis and eight centers, respectively. MRI reports and patient data including blood values, age, and further clinical information were provided to GPT-4 and to radiologists with 1 (Resident 1), 2 (Resident 2), and 4 years (Resident 3) of experience in cardiovascular MRI and knowledge of the 2018 Lake Louise Criteria. The final impression of the report regarding the radiological assessment of whether myocarditis is present or not was not provided. The performance of GPT-4 and of the human readers were compared to a consensus reading (two board-certified radiologists with 8 and 10 years of experience in cardiovascular MRI). Sensitivity, specificity, and accuracy were calculated. RESULTS: GPT-4 yielded an accuracy of 83%, sensitivity of 90%, and specificity of 78%, which was comparable to the physician with 1 year of experience (R1: 86%, 90%, 84%, p=.14) and lower than that of more experienced physicians (R2: 89%, 86%, 91%, p=.007 and R3: 91%, 85%, 96%, p<.001). GPT-4 and human readers showed a higher diagnostic performance when results from T1- and T2-mapping sequences were part of the reports, for Residents 1 and Resident 3 with statistical significance (p=.004 and p=.02, respectively). CONCLUSION: GPT-4 yielded good accuracy for diagnosing myocarditis based on MRI reports in a large dataset from multiple centers and therefore holds the potential to serve as a diagnostic decision supporting tool in this capacity, particularly for less experienced physicians. Further studies are required to explore the full potential and elucidate educational aspects of the integration of large language models in medical decision-making.

5.
CVIR Endovasc ; 7(1): 53, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38976091

RESUMEN

BACKGROUND: The Viabahn endoprosthesis has become a vital option for endovascular therapy, yet there is limited long-term data on its effectiveness for peripheral aneurysm repair. This study aimed to evaluate the safety, technical and clinical success, and long-term patency of the Viabahn endoprosthesis for treating femoropopliteal aneurysms. METHODS: This retrospective tertiary single-center study analyzed patients who underwent a Viabahn endoprosthesis procedure for femoropopliteal aneurysm repair from 2010 to 2020. Intraoperative complications, technical and clinical success rates, and major adverse events (MAE, including acute thrombotic occlusion, major amputation, myocardial infarction, and device- or procedure-related death) at 30 days were assessed. Incidence of clinically-driven target lesion revascularisation (cdTLR) was noted. Patency rates were evaluated by Kaplan-Meier analysis. RESULTS: Among 19 patients (mean age, 72 ± 12 years; 18 male, 1 female) who underwent aneurysm repair using the Viabahn endoprosthesis, there were no intraoperative adverse events, with 100% technical and clinical success rates. At the 30-day mark, all patients (19/19, 100%) were free of MAE. The median follow-up duration was 1,009 days [IQR, 462-1,466]. Popliteal stent graft occlusion occurred in 2/19 patients (10.5%) after 27 and 45 months, respectively. Consequently, the primary patency rates were 100%, 90%, 74% at 12, 24, and 36-72 months, respectively. Endovascular cdTLR was successful in both cases, resulting in sustained secondary patency at 100%. CONCLUSION: The use of Viabahn endoprostheses for femoropopliteal aneurysm repair demonstrated technical and clinical success rates of 100%, a 0% 30-day MAE rate, and excellent long-term patency.

6.
CVIR Endovasc ; 7(1): 23, 2024 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-38416319

RESUMEN

BACKGROUND: The Viabahn stent graft has emerged as an integral tool for managing vascular diseases, but there is limited long-term data on its performance in emergency endovascular treatment. This study aimed to assess safety, technical success, and long-term efficacy of the Viabahn stent graft in emergency treatment of arterial injury. METHODS: We conducted a retrospective single tertiary centre analysis of patients who underwent Viabahn emergency arterial injury treatment between 2015 and 2020. Indication, intraoperative complications, technical and clinical success, and major adverse events at 30 days were evaluated. Secondary efficacy endpoints were the primary and secondary patency rates assessed by Kaplan-Meier analysis. RESULTS: Forty patients (71 ± 13 years, 19 women) were analyzed. Indications for Viabahn emergency treatment were extravasation (65.0%), arterio-venous fistula (22.5%), pseudoaneurysm (10.0%), and arterio-ureteral fistula (2.5%). No intraoperative adverse events occurred, technical and clinical success rates were 100%. One acute stent graft occlusion occurred in the popliteal artery on day 9, resulting in a 30-day device-related major-adverse-event rate of 2.5%. Median follow-up was 402 days [IQR, 43-1093]. Primary patency rate was 97% (95% CI: 94-100) in year 1, and 92% (95% CI: 86-98) from years 2 to 6. One stent graft occlusion occurred in the external iliac artery at 18 months; successful revascularization resulted in secondary patency rates of 97% (95% CI: 94-100) from years 1 to 6. CONCLUSION: Using Viabahn stent graft in emergency arterial injury treatment had 100% technical and clinical success rates, a low 30-day major-adverse-event rate of 2.5%, and excellent long-term patency rates.

7.
Diagn Interv Imaging ; 105(7-8): 273-280, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38368176

RESUMEN

PURPOSE: The purpose of this study was to evaluate the capabilities of photon-counting (PC) CT combined with artificial intelligence-derived coronary computed tomography angiography (PC-CCTA) stenosis quantification and fractional flow reserve prediction (FFRai) for the assessment of coronary artery disease (CAD) in transcatheter aortic valve replacement (TAVR) work-up. MATERIALS AND METHODS: Consecutive patients with severe symptomatic aortic valve stenosis referred for pre-TAVR work-up between October 2021 and June 2023 were included in this retrospective tertiary single-center study. All patients underwent both PC-CCTA and ICA within three months for reference standard diagnosis. PC-CCTA stenosis quantification (at 50% level) and FFRai (at 0.8 level) were predicted using two deep learning models (CorEx, Spimed-AI). Diagnostic performance for global CAD evaluation (at least one significant stenosis ≥ 50% or FFRai ≤ 0.8) was assessed. RESULTS: A total of 260 patients (138 men, 122 women) with a mean age of 78.7 ± 8.1 (standard deviation) years (age range: 51-93 years) were evaluated. Significant CAD on ICA was present in 126/260 patients (48.5%). Per-patient sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 96.0% (95% confidence interval [CI]: 91.0-98.7), 68.7% (95% CI: 60.1-76.4), 74.3 % (95% CI: 69.1-78.8), 94.8% (95% CI: 88.5-97.8), and 81.9% (95% CI: 76.7-86.4) for PC-CCTA, and 96.8% (95% CI: 92.1-99.1), 87.3% (95% CI: 80.5-92.4), 87.8% (95% CI: 82.2-91.8), 96.7% (95% CI: 91.7-98.7), and 91.9% (95% CI: 87.9-94.9) for FFRai. Area under the curve of FFRai was 0.92 (95% CI: 0.88-0.95) compared to 0.82 for PC-CCTA (95% CI: 0.77-0.87) (P < 0.001). FFRai-guidance could have prevented the need for ICA in 121 out of 260 patients (46.5%) vs. 97 out of 260 (37.3%) using PC-CCTA alone (P < 0.001). CONCLUSION: Deep learning-based photon-counting FFRai evaluation improves the accuracy of PC-CCTA ≥ 50% stenosis detection, reduces the need for ICA, and may be incorporated into the clinical TAVR work-up for the assessment of CAD.


Asunto(s)
Estenosis de la Válvula Aórtica , Inteligencia Artificial , Angiografía por Tomografía Computarizada , Enfermedad de la Arteria Coronaria , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Femenino , Masculino , Anciano , Estudios Retrospectivos , Anciano de 80 o más Años , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Angiografía por Tomografía Computarizada/métodos , Persona de Mediana Edad , Reserva del Flujo Fraccional Miocárdico/fisiología , Angiografía Coronaria/métodos
8.
Rofo ; 196(1): 25-35, 2024 Jan.
Artículo en Inglés, Alemán | MEDLINE | ID: mdl-37793417

RESUMEN

BACKGROUND: Photon-counting detector computed tomography (PCD-CT) is a promising new technology with the potential to fundamentally change workflows in the daily routine and provide new quantitative imaging information to improve clinical decision-making and patient management. METHOD: The contents of this review are based on an unrestricted literature search of PubMed and Google Scholar using the search terms "photon-counting CT", "photon-counting detector", "spectral CT", "computed tomography" as well as on the authors' own experience. RESULTS: The fundamental difference with respect to the currently established energy-integrating CT detectors is that PCD-CT allows for the counting of every single photon at the detector level. Based on the identified literature, PCD-CT phantom measurements and initial clinical studies have demonstrated that the new technology allows for improved spatial resolution, reduced image noise, and new possibilities for advanced quantitative image postprocessing. CONCLUSION: For clinical practice, the potential benefits include fewer beam hardening artifacts, a radiation dose reduction, and the use of new or combinations of contrast agents. In particular, critical patient groups such as oncological, cardiovascular, lung, and head & neck as well as pediatric patient collectives benefit from the clinical advantages. KEY POINTS: · Photon-counting computed tomography (PCD-CT) is being used for the first time in routine clinical practice, enabling a significant dose reduction in critical patient populations such as oncology, cardiology, and pediatrics.. · Compared to conventional CT, PCD-CT enables a reduction in electronic image noise.. · Due to the spectral data sets, PCD-CT enables fully comprehensive post-processing applications.. CITATION FORMAT: · Hagen F, Soschynski M, Weis M et al. Photon-counting computed tomography - clinical application in oncological, cardiovascular, and pediatric radiology. Fortschr Röntgenstr 2024; 196: 25 - 34.


Asunto(s)
Radiología , Tomografía Computarizada por Rayos X , Humanos , Niño , Tomografía Computarizada por Rayos X/métodos , Medios de Contraste , Tórax , Fantasmas de Imagen , Pulmón
9.
Front Oncol ; 13: 1218517, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37655107

RESUMEN

Thymic carcinomas are exceedingly rare and very aggressive malignancies of the anterior mediastinum. While thymomas exhibit a high association with paraneoplastic syndromes, these phenomena are a rarity in thymic carcinomas. In general, acanthotic syndromes such as acroceratosis neoplastica and acanthosis nigricans maligna are commonly observed as paraneoplastic phenomena in patients with carcinomas. In contrast, psoriasis vulgaris, another acanthotic disease, rarely occurs as a paraneoplasia. We report the case of a 36-year-old patient with progressive thymic carcinoma (undifferentiated carcinoma, T3N2M1a) and paraneoplastic psoriasis occurring ten months before the initial diagnosis of the carcinoma. Over the course of the disease, new psoriatic flares heralded relapse or progression of the carcinoma. To our knowledge, this is the first reported case of paraneoplastic psoriasis in thymic carcinoma.

10.
Diagn Interv Imaging ; 2023 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-37550171

RESUMEN

PURPOSE: The purpose of this study was to assess the diagnostic capabilities of cardiac magnetic resonance (CMR) T2* mapping in detecting incidental hepatic and cardiac iron overload. MATERIALS AND METHODS: Patients with various clinical indications for CMR examination were consecutively included at a single center from January 2019 to April 2023. All patients underwent T2* mapping at 1.5 T in a single mid-ventricular short-axis as part of a comprehensive routine CMR protocol. T2* measurements were performed of the heart (using a region-of-interest in the interventricular septum) and the liver, categorized according to the severity of iron overload. The degree of cardiac iron overload was categorized as mild (15 ms < T2* < 20 ms), moderate (10 ms < T2* < 15 ms) and severe (T2* < 10 ms). The degree of hepatic iron overload was categorized as mild (4 ms < T2* < 8 ms), moderate (2 ms < T2* < 4 ms), severe (T2* < 2 ms). Image quality and inter-reader agreement were assessed using intraclass correlation coefficient (ICC). RESULTS: CMR examinations from 614 patients (374 men, 240 women) with a mean age of 50 ± 18 (standard deviation) years were fully evaluable. A total of 24/614 patients (3.9%) demonstrated incidental hepatic iron overload; of these, 22/614 patients (3.6%) had mild hepatic iron overload, and 2/614 patients (0.3%) had moderate hepatic iron overload. Seven out of 614 patients (1.1%) had incidental cardiac iron overload; of these, 5/614 patients (0.8%) had mild iron overload, 1/614 patients (0.2%) had moderate iron overload, and 1/614 patients (0.2%) had severe iron overload. Good to excellent inter-reader agreement was observed for the assessment of T2* values (ICC, 0.90 for heart [95% confidence interval: 0.88-0.91]; ICC, 0.91 for liver [95% confidence interval: 0.89-0.92]). CONCLUSION: Analysis of standard CMR T2* maps detects incidental cardiac and hepatic iron overload in 1.1% and 3.9% of patients, respectively, which may have implications for further patient management. Therefore, despite an overall low number of incidental abnormal findings, T2* imaging may be included in a standardized comprehensive CMR protocol.

11.
Diagnostics (Basel) ; 13(9)2023 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-37175026

RESUMEN

(1) Background and Objectives: Dark-blood late gadolinium enhancement has been shown to be a reliable cardiac magnetic resonance (CMR) method for assessing viability and depicting myocardial scarring in ischemic cardiomyopathy. The aim of this study was to evaluate dark-blood LGE imaging compared with conventional bright-blood LGE for the detection of myocardial scarring in non-ischemic cardiomyopathies. (2) Materials and Methods: Patients with suspected non-ischemic cardiomyopathy were prospectively enrolled in this single-centre study from January 2020 to March 2023. All patients underwent 1.5 T CMR with both dark-blood and conventional bright-blood LGE imaging. Corresponding short-axis stacks of both techniques were analysed for the presence, distribution, pattern, and localisation of LGE, as well as the quantitative scar size (%). (3) Results: 343 patients (age 44 ± 17 years; 124 women) with suspected non-ischemic cardiomyopathy were examined. LGE was detected in 123 of 343 cases (36%) with excellent inter-reader agreement (κ 0.97-0.99) for both LGE techniques. Dark-blood LGE showed a sensitivity of 99% (CI 98-100), specificity of 99% (CI 98-100), and an accuracy of 99% (CI 99-100) for the detection of non-ischemic scarring. No significant difference in total scar size (%) was observed. Dark-blood imaging with mean 5.35 ± 4.32% enhanced volume of total myocardial volume, bright-blood with 5.24 ± 4.28%, p = 0.84. (4) Conclusions: Dark-blood LGE imaging is non-inferior to conventional bright-blood LGE imaging in detecting non-ischemic scarring. Therefore, dark-blood LGE imaging may become an equivalent method for the detection of both ischemic and non-ischemic scars.

12.
J Cancer Res Clin Oncol ; 149(9): 6753-6757, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36749424

RESUMEN

PURPOSE: Epithelioid hemangioendothelioma (EHE) as a very rare malignant vascular tumor belongs to the heterogenous group of soft-tissue sarcomas. Depending on the clinical course of the disease, interdisciplinary treatment concepts are required, including surgery, radiotherapy and systemic cancer therapy. However, due to its uncommonness, standard treatment options are lacking so far, especially in advanced disease with distant metastases. METHODS AND RESULTS: Here we report on an unusual case of a patient with metastasized EHE showing long-term response to second line treatment with gemcitabine over almost 2 decades. Cancer genome sequencing of the patient's tumor tissue detected a NOTCH3 missense mutation which could provide an explanation for these clinical findings. NOTCH3 is known to be a mediator of resistance towards gemcitabine-based cancer treatment, at least in pancreatic cancer and non-small cell lung cancer. CONCLUSION: The observation that this missense mutation of NOTCH3 is associated with an increased response to treatment with gemcitabine in EHE can be used prospectively to assess NOTCH3 as potential biomarker for predicting therapy response to gemcitabine.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Hemangioendotelioma Epitelioide , Neoplasias Pulmonares , Humanos , Hemangioendotelioma Epitelioide/tratamiento farmacológico , Hemangioendotelioma Epitelioide/genética , Hemangioendotelioma Epitelioide/patología , Gemcitabina , Mutación Missense , Receptor Notch3/genética
14.
JACC Case Rep ; 6: 101694, 2023 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-36704065

RESUMEN

We discuss the rare case of a myocardial abscess of the left ventricle in a 42-year-old man on immunosuppressive therapy after fulminant myocarditis. Multimodal imaging detected the myocardial abscess along with other septic emboli caused by infection with aspergillus fumigatus, which could be treated effectively with antimycotic strategies. (Level of Difficulty: Intermediate.).

16.
Arch Gynecol Obstet ; 307(3): 827-840, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36342536

RESUMEN

PURPOSE: To limit the burden of long-term immunosuppression (IS) after uterus transplantation (UTx), removal of the uterine allograft is indicated after maximum two pregnancies. Hitherto this has required graft hysterectomy by laparotomy. Our objective was to demonstrate, as a proof of concept, the feasibility of less traumatic transplantectomy by total laparoscopic hysterectomy (TLH). PATIENT: A 37-year-old woman with uterovaginal agenesis due to Mayer-Rokitansky-Küster-Hauser syndrome (MRKHS) who had undergone neovaginoplasty at age 19 years prior to living-donor (LD) UTx in 10/2019 at age 35 years gave birth to a healthy boy by primary cesarean section in 06/2021. During pregnancy, she developed impaired renal function, with bilateral hydronephrosis, necessitating early allograft removal in 09/2021 to prevent chronic kidney disease, particularly during a potential second pregnancy. METHODS: Transplantectomy by TLH essentially followed standard TLH procedures. We paid meticulous attention to removing as much donor tissue as possible to prevent postoperative complications from residual donor tissue after stopping IS, as well as long-term vascular damage. RESULTS: TLH was performed successfully without the need to convert to open surgery. Surgical time was 90 min with minimal blood loss. No major complications occurred intra- or postoperatively and during the subsequent 9-month follow-up period. Kidney function normalized. CONCLUSIONS: To our knowledge, we report the first successful TLH-based removal of a uterine allograft in a primipara after LD UTx, thus demonstrating the feasibility of TLH in uterus recipients with MRKHS.


Asunto(s)
Cesárea , Laparoscopía , Masculino , Humanos , Femenino , Embarazo , Adulto Joven , Adulto , Donadores Vivos , Útero/anomalías , Histerectomía , Laparoscopía/métodos , Aloinjertos
17.
Diagnostics (Basel) ; 12(11)2022 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-36359572

RESUMEN

Objectives: To systematically compare two modified Look-Locker inversion recovery (MOLLI) T1 mapping sequences and their impact on (1) myocardial T1 values native, (2) post-contrast and (3) extracellular volume (ECV). Methods: 200 patients were prospectively included for 1.5 T CMR for work-up of ischemic or non-ischemic cardiomyopathies. To determine native and post-contrast T1 for ECV calculation, two different T1 mapping MOLLI acquisition schemes, 5(3)3 (designed for native scans with long T1) and 4(1)3(1)2 (designed for post-contrast scans with short T1), were acquired in identical mid-ventricular short-axis slices. Both schemes were acquired in native and post-contrast scans. Results: Datasets from 163 patients were evaluated (age 55 ± 17 years; 38% female). Myocardial T1 native for 5(3)3 was 1017 ± 42 ms vs. 956 ± 40 ms for 4(1)3(1)2, with mean intraindividual difference −61 ms (p < 0.0001). Post-contrast myocardial T1 in patients was similar for both acquisition schemes, with 494 ± 48 ms for 5(3)3 and 490 ± 45 ms for 4(1)3(1)2 and mean intraindividual difference −4 ms. Myocardial ECV for 5(3)3 was 27.6 ± 4% vs. 27 ± 4% for 4(1)3(1)2, with mean difference −0.6 percentage points (p < 0.0001). Conclusions: The T1 MOLLI 5(3)3 acquisition scheme provides a reliable estimation of myocardial T1 for the clinically relevant range of long and short T1 values native and post-contrast. In contrast, the T1 MOLLI 4(1)3(1)2 acquisition scheme may only be used for post-contrast scans according to its designed purpose.

18.
Front Cardiovasc Med ; 9: 989376, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36247463

RESUMEN

Aims: Increased high-sensitive cardiac troponin I (hs-cTnI) levels are common in patients with acute ischemic stroke. However, only a minority demonstrates culprit lesions on coronary angiography, suggesting other mechanisms, e.g., inflammation, as underlying cause of myocardial damage. Late Gadolinium Enhancement (LGE)-cardiac magnetic resonance (CMR) with mapping techniques [T1, T2, extracellular volume (ECV)] allow the detection of both focal and diffuse myocardial abnormalities. We investigated the prevalence of culprit lesions by coronary angiography and myocardial tissue abnormalities by a comprehensive CMR protocol in troponin-positive stroke patients. Methods and results: Patients with troponin-positive acute ischemic stroke and no history of coronary artery disease were prospectively enrolled. Coronary angiography and CMR (LGE, T1 + T2 mapping, ECV) were performed within the first days of the acute stroke. Twenty-five troponin-positive patients (mean age 62 years, 44% females) were included. 2 patients (8%) had culprit lesions on coronary angiography and underwent percutaneous coronary intervention. 13 patients (52%) demonstrated LGE: (i) n = 4 ischemic, (ii) n = 4 non-ischemic, and (iii) n = 5 ischemic AND non-ischemic. In the 12 LGE-negative patients, mapping revealed diffuse myocardial damage in additional 9 (75%) patients, with a high prevalence of increased T2 values. Conclusions: Our data show a low prevalence of culprit lesions in troponin-positive stroke patients. However, > 50% of the patients demonstrated myocardial scars (ischemic + non-ischemic) by LGE-CMR. Mapping revealed additional myocardial abnormalities (mostly inflammatory) in the majority of LGE-negative patients. Therefore, a comprehensive CMR protocol gives important insights in the etiology of troponin which might have implications for the further work-up of troponin-positive stroke patients.

19.
J Clin Med ; 11(20)2022 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-36294324

RESUMEN

The aim of this paper is to evaluate the diagnostic image quality of spectral dual-source photon-counting detector coronary computed tomography angiography (PCD-CCTA) for coronary artery disease in a multicenter study. The image quality (IQ), assessability, contrast-to-noise ratio (CNR), Agatston score, and radiation exposure were measured. Stenoses were quantified and compared with invasive coronary angiography, if available. A total of 92 subjects (65% male, age 58 ± 14 years) were analyzed. The prevalence of significant coronary artery disease (CAD) (stenosis ≥ 50%) was 17% of all patients, the range of the Agatston score was 0−2965 (interquartile range (IQR) 0−135). The IQ was very good (one, IQR one−two), the CNR was very high (20 ± 10), and 5% of the segments were rated non-diagnostic. The IQ and assessability were higher in proximal coronary segments (p < 0.001). Agatston scores up to 600 did not significantly affect the assessability of the coronary segments (p = 0.3). Heart rate influenced assessability only at a high-pitch mode (p = 0.009). For the invasive coronary angiography (ICA) subgroup (n = nine), the diagnostic performance for CAD per segment was high (sensitivity 92%, specificity 96%), although the limited number of patients who underwent both diagnostic modalities limits the generalization of this finding at this stage. PCD-CCTA provides good image quality for low and moderate levels of coronary calcifications.

20.
J Clin Med ; 11(17)2022 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-36078976

RESUMEN

(1) Objectives: To discriminate biopsy-proven myocarditis (chronic vs. healed myocarditis) and to differentiate from dilated cardiomyopathy (DCM) using cardiac magnetic resonance (CMR). (2) Methods: A total of 259 consecutive patients (age 51 ± 15 years; 28% female) who underwent both endomyocardial biopsy (EMB) and CMR in the years 2008−2021 were evaluated. According to right-ventricular EMB results, patients were divided into either chronic (n = 130, 50%) or healed lymphocytic myocarditis (n = 60, 23%) or DCM (n = 69, 27%). The CMR protocol included functional, strain, and late gadolinium enhancement (LGE) imaging, T2w imaging, and T2 mapping. (3) Results: Left-ventricular ejection fraction (LV-EF) was higher, and the indexed end-diastolic volume (EDV) was lower in myocarditis patients (chronic: 42%, median 96 mL/m²; healed: 49%, 86 mL/m²) compared to the DCM patients (31%, 120 mL/m²), p < 0.0001. Strain analysis demonstrated lower contractility in DCM patients vs. myocarditis patients, p < 0.0001. Myocarditis patients demonstrated a higher LGE prevalence (68% chronic; 59% healed) than the DCM patients (45%), p = 0.01. Chronic myocarditis patients showed a higher myocardial edema prevalence and ratio (59%, median 1.3) than healed myocarditis (23%, 1.3) and DCM patients (13%, 1.0), p < 0.0001. T2 mapping revealed elevated values more frequently in chronic (90%) than in healed (21%) myocarditis and DCM (23%), p < 0.0001. T2 mapping yielded an AUC of 0.89 (sensitivity 90%, specificity 76%) in the discrimination of chronic from healed myocarditis and an AUC of 0.92 (sensitivity 86%, specificity 91%) in the discrimination of chronic myocarditis from DCM, both p < 0.0001. (4) Conclusions: Multiparametric CMR imaging, including functional parameters, LGE and T2 mapping, may allow differentiation of chronic from healed myocarditis and DCM and therefore help to optimize patient management in this clinical setting.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA