Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 10 de 10
1.
Int J Radiat Biol ; 100(1): 1-6, 2024.
Article En | MEDLINE | ID: mdl-37695653

The cornerstones of science advancement are rigor in performing scientific research, reproducibility of research findings and unbiased reporting of design and results of the experiments. For radiation research, this requires rigor in describing experimental details as well as the irradiation protocols for accurate, precise and reproducible dosimetry. Most institutions conducting radiation biology research in in vitro or animal models do not have describe experimental irradiation protocols in sufficient details to allow for balanced review of their publication nor for other investigators to replicate published experiments. The need to increase and improve dosimetry standards, traceability to National Institute of Standards and Technology (NIST) standard beamlines, and to provide dosimetry harmonization within the radiation biology community has been noted for over a decade both within the United States and France. To address this requirement subject matter experts have outlined minimum reporting standards that should be included in published literature for preclinical irradiators and dosimetry.


Radiobiology , Radiometry , Animals , United States , Reproducibility of Results , Radiometry/methods , Models, Animal , France
3.
Int J Radiat Oncol Biol Phys ; 111(5): e75-e81, 2021 12 01.
Article En | MEDLINE | ID: mdl-34509551

PURPOSE: Accurate radiation dose is required to ensure reproducibility in establishing the radiobiological effect in biological systems among institutions. The dose should be the most precise and accurate parameter of the entire process. The goal is a system to provide uniform radiation dose verification among institutions that is traceable to the National Institute of Standards and Technology (NIST) through an Accredited Dosimetry Calibration Laboratory. METHODS AND MATERIALS: Radiobiological beams are not NIST traceable but can be approximated based on the radiograph's half value layer. Phantoms have been developed containing detectors to measure the dose from total body irradiation of mice and others. Ionization chambers calibrated to NIST-traceable beams are the best detectors for precise and accurate dose determinations. However, thermoluminescent dosimeters have been mostly used for this application for comparison between institutions. RESULTS: A comparison of thermoluminescent dosimeters results among surveyed institutions showed a large variation in delivered dose. The range of radiograph doses that were measured deviated from the standard dose by 12% to 42%. The results have an uncertainty of 2.5% at 1 standard deviation. The surveyed radionuclide irradiators demonstrated a dose range variation of 1.6% to 13.5% from target dose. There is less variation among high energy (linacs) because a calibrated ionization chamber is generally used by personnel (eg, medical physicist) and the output is determined for radiation therapy applications as well. CONCLUSIONS: Radiobiological dosimetry is lacking with respect to its precision and accuracy. The accuracy of radiograph calibrations for radiobiology can be estimated to be approximately 5%, because there are no NIST-traceable beams. However, among institutions, the variations can be up to 42%. Intercomparisons between institutions is important to have a clear understanding of the transference of dose between given studies.


Radiobiology , Radiometry , Calibration , Particle Accelerators , Reproducibility of Results
4.
Front Immunol ; 12: 708950, 2021.
Article En | MEDLINE | ID: mdl-34386012

Mesenchymal stromal cells (MSCs) are being tested as a cell therapy in clinical trials for dozens of inflammatory disorders, with varying levels of efficacy reported. Suitable and robust preclinical animal models for testing the safety and efficacy of different types of MSC products before use in clinical trials are rare. We here introduce two highly robust animal models of immune pathology: 1) acute radiation syndrome (ARS) and 2) graft versus host disease (GvHD), in conjunction with studying the immunomodulatory effect of well-characterized Interferon gamma (IFNγ) primed bone marrow derived MSCs. The animal model of ARS is based on clinical grade dosimetry precision and bioluminescence imaging. We found that allogeneic MSCs exhibit lower persistence in naïve compared to irradiated animals, and that intraperitoneal infusion of IFNγ prelicensed allogeneic MSCs protected animals from radiation induced lethality by day 30. In direct comparison, we also investigated the effect of IFNγ prelicensed allogeneic MSCs in modulating acute GvHD in an animal model of MHC major mismatched bone marrow transplantation. Infusion of IFNγ prelicensed allogeneic MSCs failed to mitigate acute GvHD. Altogether our results demonstrate that infused IFNγ prelicensed allogeneic MSCs protect against lethality from ARS, but not GvHD, thus providing important insights on the dichotomy of IFNγ prelicensed allogenic MSCs in well characterized and robust animal models of acute tissue injury.


Acute Radiation Syndrome/therapy , Graft vs Host Disease/therapy , Interferon-gamma/pharmacology , Mesenchymal Stem Cell Transplantation , Animals , Disease Models, Animal , Female , Luminescent Measurements , Male , Mice , Mice, Inbred BALB C , Mice, Inbred C57BL , Transplantation, Homologous
5.
Med Phys ; 48(7): e733-e770, 2021 Jul.
Article En | MEDLINE | ID: mdl-33690912

The American Association of Physicists in Medicine (AAPM) formed Task Group 178 (TG-178) to perform the following tasks: review in-phantom and in-air calibration protocols for gamma stereotactic radiosurgery (GSR), suggest a dose rate calibration protocol that can be successfully utilized with all gamma stereotactic radiosurgery (GSR) devices, and update quality assurance (QA) protocols in TG-42 (AAPM Report 54, 1995) for static GSR devices. The TG-178 report recommends a GSR dose rate calibration formalism and provides tabulated data to implement it for ionization chambers commonly used in GSR dosimetry. The report also describes routine mechanical, dosimetric, and safety checks for GSR devices, and provides treatment process quality assurance recommendations. Sample worksheets, checklists, and practical suggestions regarding some QA procedures are given in appendices. The overall goal of the report is to make recommendations that help standardize GSR physics practices and promote the safe implementation of GSR technologies.


Radiosurgery , Calibration , Gamma Rays , Phantoms, Imaging , Radiometry , United States
6.
Int J Radiat Biol ; 92(2): 59-70, 2016.
Article En | MEDLINE | ID: mdl-26857121

PURPOSE: An interlaboratory comparison of radiation dosimetry was conducted to determine the accuracy of doses being used experimentally for animal exposures within a large multi-institutional research project. The background and approach to this effort are described and discussed in terms of basic findings, problems and solutions. METHODS: Dosimetry tests were carried out utilizing optically stimulated luminescence (OSL) dosimeters embedded midline into mouse carcasses and thermal luminescence dosimeters (TLD) embedded midline into acrylic phantoms. RESULTS: The effort demonstrated that the majority (4/7) of the laboratories was able to deliver sufficiently accurate exposures having maximum dosing errors of ≤5%. Comparable rates of 'dosimetric compliance' were noted between OSL- and TLD-based tests. Data analysis showed a highly linear relationship between 'measured' and 'target' doses, with errors falling largely between 0 and 20%. Outliers were most notable for OSL-based tests, while multiple tests by 'non-compliant' laboratories using orthovoltage X-rays contributed heavily to the wide variation in dosing errors. CONCLUSIONS: For the dosimetrically non-compliant laboratories, the relatively high rates of dosing errors were problematic, potentially compromising the quality of ongoing radiobiological research. This dosimetry effort proved to be instructive in establishing rigorous reviews of basic dosimetry protocols ensuring that dosing errors were minimized.


Laboratories/statistics & numerical data , Radiation Exposure/analysis , Whole-Body Counting/instrumentation , Whole-Body Irradiation/instrumentation , Absorption, Radiation , Animals , Equipment Design , Equipment Failure Analysis , Mice , Radiation Exposure/statistics & numerical data , Reproducibility of Results , Sensitivity and Specificity , Whole-Body Counting/methods , Whole-Body Counting/statistics & numerical data , Whole-Body Irradiation/statistics & numerical data
7.
Radiat Res ; 185(2): 163-8, 2016 Feb.
Article En | MEDLINE | ID: mdl-26771174

Interest in standardized dosimetry for radiobiological irradiators has expanded over the last decade. At a symposium held at NIST, "The Importance of Standardization of Dosimetry in Radiobiology", a set of 12 criteria necessary for adequate irradiation was developed by the authors. Here we report on our review of dosimetry methods from various peer-reviewed publications and found that none of them satisfied all 12 criteria set forth by the authors of the NIAD/NCI/NIST proceedings. The inadequate reporting of dosimetry methods in the literature raises questions regarding the accuracy of the dose delivered to animal test subjects and the resulting experimental results. For this reason, we investigated the level of accuracy of dose delivery in radiation biology studies. We performed an irradiator output verification study of 12 radiation biology laboratories (7 gamma and 5 X-ray units) using polymethyl methacrylate (PMMA) mouse phantoms and thermoluminescent dosimeters (TLDs) readouts at the University of Wisconsin Medical Radiation Research Center (UWMRRC). The laboratories housing each of these irradiators were asked to deliver specific doses to individual mouse phantoms. Simultaneously, mouse phantoms at the UWMRRC were irradiated with NIST-traceable reference beams representative of the subject laboratories' beam energies. The irradiated mouse phantoms were returned from the various institutions to the UWMRRC and the TLDs were processed, with their measured dose response compared to the known dose response of the calibration phantom TLDs. Of the five facilities using X-ray irradiators, only one delivered an output within 5% of the target dose. The dose differences for the other four X-ray irradiators ranged from 12 to 42%. These results indicate the potential need for standardization of dose determination and additional oversight of radiobiology investigations.


Biological Assay/instrumentation , Biological Assay/standards , Laboratories/standards , Radiation Exposure/analysis , Thermoluminescent Dosimetry/instrumentation , Thermoluminescent Dosimetry/standards , Equipment Design , Equipment Failure Analysis , Guideline Adherence , Radiation Dosage , Reproducibility of Results , Sensitivity and Specificity , Surveys and Questionnaires , United States
8.
Med Phys ; 37(6): 2693-702, 2010 Jun.
Article En | MEDLINE | ID: mdl-20632580

PURPOSE: Intracavitary accelerated partial breast irradiation (APBI) has become a popular treatment for early stage breast cancer in recent years due to its shortened course of treatment and simplified treatment planning compared to traditional external beam breast conservation therapy. However, the exit dose to the skin is a major concern and can be a limiting factor for these treatments. Most treatment planning systems (TPSs) currently used for high dose-rate (HDR) 192Ir brachytherapy overestimate the exit skin dose because they assume a homogeneous water medium and do not account for finite patient dimensions. The purpose of this work was to quantify the TPS overestimation of the exit skin dose for a group of patients and several phantom configurations. METHODS: The TPS calculated skin dose for 59 HDR 192Ir APBI patients was compared to the skin dose measured with LiF:Mg,Ti thermoluminescent dosimeters (TLDs). Additionally, the TPS calculated dose was compared to the TLD measured dose and the Monte Carlo (MC) calculated dose for eight phantom configurations. Four of the phantom configurations simulated treatment conditions with no scattering material beyond the point of measurement and the other four configurations simulated the homogeneous scattering conditions assumed by the TPS. Since the calibration TLDs for this work were irradiated with 137Cs and the experimental irradiations were performed with 192Ir, experiments were performed to determine the intrinsic energy dependence of the TLDs. Correction factors that relate the dose at the point of measurement (center of TLD) to the dose at the point of interest (basal skin layer) were also determined and applied for each irradiation geometry. RESULTS: The TLD intrinsic energy dependence for 192Ir relative to 137Cs was 1.041 +/- 1.78%. The TPS overestimated the exit skin dose by an average of 16% for the group of 59 patients studied, and by 9%-15% for the four phantom setups simulating treatment conditions. For the four phantom setups simulating the conditions assumed by the TPS, the TPS calculated dose agreed well with the TLD and MC results (within 3% and 1%, respectively). The inverse square geometry correction factor ranged from 1.023 to 1.042, and an additional correction factor of 0.978 was applied to account for the lack of charged particle equilibrium in the TLD and basal skin layer. CONCLUSIONS: TPS calculations that assume a homogeneous water medium overestimate the exit skin dose for intracavitary APBI treatments. It is important to determine the actual skin dose received during intracavitary APBI to determine the skin dose-response relationship and establish dose limits for optimal skin sparing. This study has demonstrated that TLDs can measure the skin dose with an expanded uncertainty (k = 2) of 5.6% when the proper corrections are applied.


Body Burden , Brachytherapy/methods , Breast Neoplasms/radiotherapy , Iridium/therapeutic use , Radioisotopes/therapeutic use , Skin , Thermoluminescent Dosimetry/methods , Algorithms , Humans , Radiotherapy, Computer-Assisted/methods
9.
Int J Radiat Oncol Biol Phys ; 59(4): 1107-15, 2004 Jul 15.
Article En | MEDLINE | ID: mdl-15234045

PURPOSE: To investigate the maximal tolerated dose of a continuous 28-day iododeoxyuridine (IUdr) infusion combined with hyperfractionated accelerated radiotherapy (HART); to analyze the percentage of IUdr-thymidine replacement in peripheral granulocytes as a surrogate marker for IUdr incorporation into tumor cells; to measure the steady-state serum IUdr levels; and to assess the feasibility of continuous IUdr infusion and HART in the management of malignant glioma. METHODS AND MATERIALS: Patients were required to have biopsy-proven malignant glioma. Patients received 100 (n = 4), 200 (n = 3), 300 (n = 3), 400 (n = 6), 500 (n = 4), 625 (n = 5), or 781 (n = 6) mg/m(2)/d of IUdr by continuous infusion for 28 days. HART was started 7 days after IUdr initiation. The total dose was 70 Gy (1.2 Gy b.i.d. for 25 days with a 10-Gy boost [2.0 Gy for 5 Saturdays]). Weekly assays were performed to determine the percentage of IUdr-DNA replacement in granulocytes and serum IUdr levels using standard high performance liquid chromatography methods. Standard Phase I toxicity methods were used. RESULTS: Between June 1994 and August 1999, 31 patients were enrolled. No patient had Grade 3 or worse HART toxicity. Grade 3 or greater IUdr toxicity predominantly included neutropenia (n = 3), thrombocytopenia (n = 3), and elevated liver function studies (n = 3). The maximal tolerated dose was 625 mg/m(2)/d. Thymidine replacement in the peripheral granulocytes peaked at 3 weeks and increased with the dose (maximal thymidine replacement 4.9%). The steady-state plasma IUdr level increased with the dose (maximum, 1.5 microM). CONCLUSION: In our study, continuous long-term IUdr i.v. infusion had a maximal tolerated dose of 625 mg/m(2)/d. Granulocyte incorporation data verified the concept that prolonged IUdr infusion results in IUdr-DNA replacement that corresponds to a high degree of cell labeling. IUdr steady-state plasma levels increased with increasing dose and attained levels needed for clinical radiosensitization. Continuous IUdr infusion and HART were both feasible and well tolerated.


Astrocytoma/radiotherapy , Brain Neoplasms/radiotherapy , Idoxuridine/administration & dosage , Radiation-Sensitizing Agents/administration & dosage , Adult , Aged , Astrocytoma/metabolism , Brain Neoplasms/metabolism , Dose Fractionation, Radiation , Female , Humans , Idoxuridine/adverse effects , Idoxuridine/pharmacokinetics , Infusions, Intravenous , Karnofsky Performance Status , Male , Maximum Tolerated Dose , Middle Aged , Radiation-Sensitizing Agents/adverse effects , Radiation-Sensitizing Agents/pharmacokinetics
10.
Cancer J ; 9(4): 277-85, 2003.
Article En | MEDLINE | ID: mdl-12967138

PURPOSE: Ribonucleotide reductase is the rate-limiting enzyme in the de novo synthesis of deoxyribonucleotide triphosphates, which are utilized in both DNA synthesis and DNA repair. We reported previously that RR enzyme activity and R2 (catalytic subunit of RR) protein levels were increased after exposure to ionizing radiation (IR) in growth-arrested human tumor cells, suggesting that R2 protein expression regulates RR activity to allow for IR damage repair. Using isogenic human nasopharyngeal carcinoma cells in this study, we examine the relationship of overexpression of either the R1 regulatory subunit or the R2 catalytic subunit of RR to the cellular response of IR damage. MATERIALS AND METHODS: We used three isogenic human nasopharyngeal cancer cell lines previously derived by Zhou et al, including KB, the parental tumor cell line; KB/M1, an R1 protein-overexpressing clone stably transfected with human R1 complementary DNA; and KB/M2, a R2 protein-overexpressing clone stably transfected with human R2 complementary DNA. We initially characterized these isogenic human tumor cell lines in exponential growth for R2 protein expression, RR enzyme activity, and R2 protein changes during the cell cycle by flow cytometry. Subsequently, the IR response in these cell lines was determined by clonogenic survival, cell cycle changes occurring after IR, and an analysis of IR DNA damage determined by pulsed field gel electrophoresis. The effect of combining IR and hydroxyurea, a RR (R2) inhibitor, was also studied in KB and KB/M2 cells. RESULTS: KB/M2 cells were found to have 4.5-fold higher R2 protein expression and a threefold higher RR enzyme activity in exponential growth than KB and KB/M1. Although R2 protein levels increased at the G1/S transition in all cell lines, KB/M2 cells also demonstrated consistently higher R2 protein levels throughout the cell cycle. Using a linear-quadratic analysis of IR clonogenic survival data, KB/M2 cells were more radioresistant than KB and KB/M1 cells, including both decreased alpha and decreased beta values, a finding that correlates with increased reparable IR damage. KB/M2 cells also show a reduced G2 cell cycle arrest and fewer DNA double strand breaks 18 hours after IR (6 Gy). Exposure of KB/M2 cells to hydroxyurea (300 microM) after exposure to IR restored in vitro radiosensitivity in a manner similar to that found in KB and KB/M1 cells. DISCUSSION: An increase in R2 protein levels and RR activity in KB/M2 cells results in IR resistance, which appears mediated by enhanced IR damage repair during G2. R1 protein overexpression in these isogenic human tumor cells (KB/M1) did not affect RR activity or IR response.


Antineoplastic Agents/pharmacology , Carcinoma , DNA Repair , Enzyme Inhibitors/pharmacology , Hydroxyurea/pharmacology , Nasopharyngeal Neoplasms , Radiation-Sensitizing Agents/pharmacology , Ribonucleoside Diphosphate Reductase/metabolism , Blotting, Western , Carcinoma/drug therapy , Carcinoma/enzymology , Carcinoma/radiotherapy , Cell Cycle , Cell Line, Tumor , DNA Repair/drug effects , DNA Repair/radiation effects , Drug Resistance, Neoplasm/drug effects , Drug Resistance, Neoplasm/radiation effects , Gene Expression Regulation, Enzymologic/drug effects , Gene Expression Regulation, Enzymologic/radiation effects , Gene Expression Regulation, Neoplastic/drug effects , Gene Expression Regulation, Neoplastic/radiation effects , Humans , In Vitro Techniques , KB Cells/drug effects , KB Cells/radiation effects , Nasopharyngeal Neoplasms/drug therapy , Nasopharyngeal Neoplasms/enzymology , Nasopharyngeal Neoplasms/radiotherapy , Radiation Tolerance/drug effects , Ribonucleoside Diphosphate Reductase/drug effects , Ribonucleoside Diphosphate Reductase/genetics , Transfection , Up-Regulation/drug effects , Up-Regulation/radiation effects
...