Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Oral Dis ; 21(6): 755-61, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25825335

RESUMEN

OBJECTIVE: This study evaluated the association of four histopathological grading systems (WHO grading system, malignancy grading of the deep invasive margins (MG), histological risk (HR) model, and tumor budding and depth of invasion (BD) model) with clinicopathological parameters and outcome of 113 oral squamous cell carcinomas to identify their roles in prognosis. METHODS: Demographic and clinical features were obtained from patients' records. Sections from all paraffin-embedded blocks were evaluated according to the four grading systems. Demographic and clinical associations were analyzed using chi-square test, and correlations between the grading systems were established with the Spearman's rank correlation test. Survival curves were performed with Kaplan-Meier method, and multivariate analysis based on Cox proportional hazard model was calculated. RESULTS: Significant associations with survival were observed for WHO grading system and BD model in the univariate analysis, but only the BD model was significantly associated with disease outcome as an independent prognostic marker. Age, tumor size, and presence of regional metastasis were also independent markers of reduced survival. CONCLUSION: A significant association between the BD model and outcome of OSCC patients was observed, indicating this new histopathological grading system as a possible prognostic tool.


Asunto(s)
Carcinoma de Células Escamosas/patología , Neoplasias de la Boca/patología , Clasificación del Tumor/métodos , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Carcinoma de Células Escamosas/secundario , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Tasa de Supervivencia , Carga Tumoral
2.
Rofo ; 177(5): 637-45, 2005 May.
Artículo en Alemán | MEDLINE | ID: mdl-15871078

RESUMEN

PURPOSE: To evaluate the contribution of early systole for the assessment of antegrade aortic flow volume by breath-hold velocity-encoded magnetic resonance (MR) flow measurements. MATERIALS AND METHODS: Expiratory breath-hold fast low-angle shot (FLASH) phase-contrast flow measurements (temporal resolution tRes 61 msec, shared phases) perpendicular to the proximal ascending aorta and short axis true fast imaging with steady-state precession (TrueFISP) cine MR ventriculometry (tRes 34.5 msec) were performed in ten healthy male volunteers on a 1.5 T MR system (Sonata, Siemens Medical Solutions). Antegrade aortic flow volume (AFV) and left ventricular stroke volume (LV-SV) were evaluated using Argus Ventricular Function and Argus Flow Software, version MR 2002B (Siemens Medical Solutions). A beta release of Argus Flow MR 2004A allowed interpolation of the flow up-slope during early systole to the preceding R-wave trigger. The respective intraindividual median differences between the AFV of each flow evaluation and LV-SV as well as between both AFV measurements were calculated and compared using the sign test for paired samples. RESULTS: Non-interpolated AFV significantly deviated from LV-SV (p = 0.006), underestimating the latter by 13.1 mL (13 %). Interpolating aortic flow during early systole significantly increased AFV by 10.8 mL (13 %) compared to the flow evaluation which did not take early systole into account (p = 0.006). AFV with interpolation of early systolic flow agreed well with LV-SV (median difference - 3.0 mL or - 3 %, respectively), and no significant difference between these measurements was found (p = 1.0). CONCLUSION: Flow during early systole contributes substantially to total forward flow volume in the ascending aorta. Interpolation of the early systolic up-slope is therefore recommended for the evaluation of breath-hold phase-contrast flow measurements.


Asunto(s)
Aorta/fisiología , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Respiración , Volumen Sistólico/fisiología , Sístole/fisiología , Función Ventricular Izquierda/fisiología , Adulto , Aorta/anatomía & histología , Artefactos , Velocidad del Flujo Sanguíneo/fisiología , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Movimiento , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
Rofo ; 177(5): 646-54, 2005 May.
Artículo en Alemán | MEDLINE | ID: mdl-15871079

RESUMEN

PURPOSE: Little is known about the dispersion of a defined contrast bolus during its passage through the heart and pulmonary vasculature. The purpose of this study was to analyze factors influencing a defined contrast bolus for ce-MRA of thoracic vessels. MATERIALS AND METHODS: For analysis of bolus geometry, an ECG-gated saturation-recovery Turbo-Flash sequence with a TI of 20 msec was used. It was acquired axially at the level of the pulmonary trunc, so that with one data acquisition a curve analysis was possible in the ascending and descending aorta, and in the pulmonary trunc. Twenty-nine patients received 3 ml of Gd-DTPA diluted with saline to a total of 20 ml. Contrast injection was done using a MR compatible power injector with injection rates varying between 1, 2 and 4 ml/sec. Each injection was followed by a saline flush of 20 ml with the same injection rate and mode. Cardiac function was assessed by cine imaging, and phase contrast measurements. After normalization to baseline signal intensity (SI), bolus curves were fitted using a gamma-variate fit and peak signal intensity (peak SI), time-to-peak (TP), upslope, mean transit time (MTT) and dispersion of the contrast bolus were calculated. Furthermore, T (1) and [Gd] in the experimental setting were calculated as follows: T (1) = T (1 o)/ ln [SI/SI (0)], and [Gd] (exp) = [1/T (1) - 1/T (1 o)]/ R (1.) They were then extrapolated [Gd] to clinical conditions by [Gd] (clin) = [Gd] (exp) . 10/1.5, and minimal blood T (1) by T (1)(clin) = 1 / [1/T (1 o) + R (1) [Gd] (clin)]. RESULTS: With increasing injection rate, there was a significant decrease (p < 0.001) of MTT in all target vessels. However, this decrease was not linear: a 4-fold increase in injection rate lead to a 2-fold decrease in MTT e. g. in the ascending aorta. MTT was significantly shorter in the pulmonary trunc compared with that in the ascending and descending aorta (p < 0.001), regardless of injection rate (p < 0.001). Vice versa, dispersion of the contrast bolus was significantly lower in the pulmonary trunc, and increased with higher injection rates. There was no clinically relevant difference in minimal blood T (1) between the different target vessels, for clinical conditions extrapolated values ranged between 20 und 79 msec. Heart function parameters only had a minor influence of bolus curve parameters. CONCLUSION: Analysis of bolus geometry enables determination of transit times of a defined contrast bolus through a defined target vessel in the thoracic cavity. Bolus geometry is mainly determined by injection parameters, cardiac function is of minor importance. Dispersion of contrast bolus and MTT increase from the pulmonary trunc to the ascending aorta. The knowledge of these facts may help optimizing of injection parameters and the total amount of contrast agent for contrast-enhanced MRA of thoracic vessels.


Asunto(s)
Medios de Contraste , Gadolinio DTPA , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Tórax/irrigación sanguínea , Tórax/patología , Adulto , Anciano , Cardiomiopatías/diagnóstico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
4.
Rofo ; 176(9): 1245-50, 2004 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-15346258

RESUMEN

PURPOSE: Quantification of left and right ventricular function using MRI in young cancer patients treated with cardiotoxic anthracyclines. MATERIALS AND METHODS: Twenty-eight patients (mean age 16.4 years) underwent cardiac MRI at 1.5 T. The study protocol consisted of morphologic T2-weighted images with fat suppression and cine steady-state free precession sequences (SSFP) for functional analysis. Seven patients were examined at the end of chemotherapy, two of them also repeatedly during therapy, and 21 patients following an average period of three years after finishing chemotherapy (range one month--20 years) RESULTS: The end-systolic volume index increased and the ejection fraction of the left and right ventricle decreased during anthracycline therapy. Two of seven patients showed a myocardial edema at the end of the therapy. In 15 of all 28 patients, the left ventricular ejection fraction was reduced to less than 55 % (minimum 44 %). No clinical signs of cardiac insufficiency or cardiomyopathy were observed. CONCLUSION: MRI is able to detect acute as well as chronic subclinical cardiotoxic effects of anthracyclines. Impairment of the right ventricular function should be considered in the diagnosis of anthracycline-induced cardiomyopathy.


Asunto(s)
Antraciclinas/efectos adversos , Cardiomiopatías/inducido químicamente , Cardiomiopatías/diagnóstico , Imagen por Resonancia Magnética/métodos , Neoplasias/tratamiento farmacológico , Volumen Sistólico , Función Ventricular , Adolescente , Adulto , Factores de Edad , Antraciclinas/uso terapéutico , Niño , Ecocardiografía , Femenino , Estudios de Seguimiento , Humanos , Imagen por Resonancia Cinemagnética , Masculino , Factores de Tiempo , Función Ventricular Izquierda , Función Ventricular Derecha
5.
Rofo ; 176(8): 1079-88, 2004 Aug.
Artículo en Alemán | MEDLINE | ID: mdl-15346282

RESUMEN

The limited lifetime and the correlation between graft occlusion and recurring symptoms underline the need for repeated imaging of coronary artery bypass grafts. CT and MRI allow for non-invasive imaging of coronary bypasses with high accuracies concerning the patency of these vessels. Multidetector CT seems to be the CT technique of choice, especially after the introduction of 16 slice CT scanners for morphologic assessment of coronary artery bypass grafts. Compared with MRI, CT is a robust technique for assessment of cardiac anastomoses, native coronary arteries, and for the detection of graft stenoses. MRI, however, is able to deliver functional information about the grafts and the recipient coronary arteries by determining the coronary flow reserve. Furthermore, it can be integrated in a multiparametric MR examination protocol. The follow-up of asymptomatic patients can primarily be done by these non-invasive techniques as nearly every third patient reveals an asymptomatic bypass occlusion 5 years after operation. Furthermore, patients with atypical complaints after the operation may undergo non-invasive imaging as long as documented patency of the bypass averts coronary angiography. Patients with recurrent angina pectoris and/or myocardial ischemia discovered by other cardiologic tests have to undergo coronary angiography.


Asunto(s)
Puente de Arteria Coronaria/métodos , Puente de Arteria Coronaria/efectos adversos , Reestenosis Coronaria/diagnóstico , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/epidemiología , Humanos , Imagen por Resonancia Magnética/métodos , Recurrencia , Tomografía Computarizada por Rayos X/métodos
6.
Eur Radiol ; 11(8): 1355-63, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11519543

RESUMEN

The aim of this study was to test three injection protocols for contrast-enhanced magnetic resonance angiography (MRA) of the thoracic aorta with a standard-dose application. Ninety-three patients with a total of 118 examinations underwent MRA of the thoracic aorta at 1.5 T. There were three injection protocols: in 24 cases, no test bolus was performed and contrast was injected manually; in 14 cases, contrast was injected manually after a test bolus; and in 80 cases, a MR-compatible injector was used after a timing examination. All patients received 20 ml of Gd-DTPA. Quantitative signal-to-noise (SNR) measurements were obtained at different locations in the thoracic aorta, the pulmonary arteries, and the superior vena cava. Two readers in conference retrospectively evaluated each examination with respect to overall image quality and quality of bolus timing. Bolus timing was considered optimal in 70 cases, and either too early or too late in 11 cases. In 37 examinations the bolus was broadened. The SNR measurements of the thoracic aorta revealed that examinations after bolus testing were significantly superior to examinations without a test bolus (p < 0.001). Signal intensity ratios of the aorta and the pulmonary trunk were significantly higher in examinations with an optimal contrast timing (p < 0.001). Magnetic resonance angiograms of the thoracic aorta with a timing run are significantly superior to non-timed examinations with respect to image quality and SNRs. The administration of 20 ml of Gd-DTPA is sufficient for adult patients.


Asunto(s)
Aorta Torácica/patología , Medios de Contraste/administración & dosificación , Gadolinio DTPA , Angiografía por Resonancia Magnética , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Enfermedades de la Aorta/diagnóstico , Femenino , Gadolinio DTPA/administración & dosificación , Humanos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Inyecciones Intravenosas/instrumentación , Inyecciones Intravenosas/métodos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA