Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 137
1.
Eur Heart J ; 2024 May 15.
Article En | MEDLINE | ID: mdl-38747246

BACKGROUND AND AIMS: Transcatheter aortic valve implantation (TAVI) has become the first choice to treat older patients with severe symptomatic aortic stenosis (AS). This study aimed to compare TAVI with surgery in low-risk patients ≤ 75 years of age, including both tricuspid and bicuspid AS. METHODS: The NOTION-2 trial enrolled and 1:1 randomized low-risk patients aged ≤ 75 years with severe symptomatic AS to TAVI or surgery. The primary endpoint was a composite of all-cause mortality, stroke or rehospitalization (related to the procedure, valve or heart failure) at 12 months. RESULTS: A total of 370 patients were enrolled with a mean age of 71.1 years and a median Society of Thoracic Surgeons risk score of 1.1%. A total of 100 patients had bicuspid AS. The 1-year incidence of the primary endpoint was 10.2% in the TAVI group and 7.1% in the surgery group (absolute risk difference 3.1%; 95% confidence interval [CI], -2.7% to 8.8%; hazard ratio (HR) 1.4, 95% CI: 0.7 to 2.9; p=0.3). Patients with TAVI, when compared to surgery, had lower risk of major bleeding and new-onset atrial fibrillation and higher risk of non-disabling stroke, permanent pacemaker implantation and moderate-or-greater paravalvular regurgitation. The risk of the primary composite endpoint was 8.7% and 8.3% in patients with tricuspid AS (HR 1.0, 95% CI: 0.5 to 2.3) and 14.3% and 3.9% in patients with bicuspid AS (HR 3.8, 95% CI: 0.8 to 18.5) treated with TAVI or surgery, respectively (P for interaction=0.1). CONCLUSIONS: Among low-risk patients aged ≤ 75 years with severe symptomatic AS, the rate of the composite of death, stroke, or rehospitalization at one year was similar between TAVI and surgery. TAVI outcomes in young bicuspid AS patients warrant caution and should be further investigated. (NOTION-2, ClinicalTrials.gov, NCT02825134).

2.
Struct Heart ; 8(3): 100277, 2024 May.
Article En | MEDLINE | ID: mdl-38799801

Inferior outcomes with ACURATE neo, a self-expanding transcatheter heart valve (THV) for the treatment of severe aortic stenosis, were mainly driven by higher rates of moderate/severe paravalvular leak (PVL). To overcome this limitation, the next-generation ACURATE neo2 features a 60% larger external sealing skirt. Data on long-term performance are limited; however, clinical evidence suggests improved short-term performance which is comparable to contemporary THVs. This report reviews data on short-term clinical and echocardiographic outcomes of ACURATE neo2. A PubMed search yielded 13 studies, including 5 single arm and 8 nonrandomized comparative studies with other THVs which reported in-hospital or 30-day clinical and echocardiographic outcomes. In-hospital or 30-day all-cause mortality was ≤3.3%, which is comparable to other contemporary THVs. The rates of postprocedural ≧moderate PVL ranged 0.6%-4.7%. In multicenter propensity-matched analyses, neo2 significantly reduced the rate of ≧moderate PVL compared to neo (3.5% vs. 11.3%, p < 0.01), whereas rates were comparable to Evolut Pro/Pro+ (Neo2: 2.0% vs. Pro/Pro+: 3.1%, p = 0.28) and SAPIEN 3 Ultra (Neo2: 0.6% vs. Ultra: 1.1%, p = 0.72). The rate of permanent pacemaker implantation with neo2 was consistently low (3.3%-8.6%) except in one study, and in propensity-matched analyses were significantly lower than Evolut Pro/Pro+ (6.7% vs. 16.7%, p < 0.01), and comparable to SAPIEN 3 Ultra (8.1% vs. 10.3%, p = 0.29). In conclusion, ACURATE neo2 showed better short-term performance by considerably reducing PVL compared to its predecessor, with short-term clinical and echocardiographic outcomes comparable to contemporary THVs.

3.
N Engl J Med ; 390(16): 1481-1492, 2024 Apr 25.
Article En | MEDLINE | ID: mdl-38587995

BACKGROUND: The benefit of fractional flow reserve (FFR)-guided complete revascularization in patients with ST-segment elevation myocardial infarction (STEMI) and multivessel coronary artery disease remains unclear. METHODS: In this multinational, registry-based, randomized trial, we assigned patients with STEMI or very-high-risk non-STEMI (NSTEMI) and multivessel disease who were undergoing primary percutaneous coronary intervention (PCI) of the culprit lesion to receive either FFR-guided complete revascularization of nonculprit lesions or no further revascularization. The primary outcome was a composite of death from any cause, myocardial infarction, or unplanned revascularization. The two key secondary outcomes were a composite of death from any cause or myocardial infarction and unplanned revascularization. RESULTS: A total of 1542 patients underwent randomization, with 764 assigned to receive FFR-guided complete revascularization and 778 assigned to receive culprit-lesion-only PCI. At a median follow-up of 4.8 years (interquartile range, 4.3 to 5.2), a primary-outcome event had occurred in 145 patients (19.0%) in the complete-revascularization group and in 159 patients (20.4%) in the culprit-lesion-only group (hazard ratio, 0.93; 95% confidence interval [CI], 0.74 to 1.17; P = 0.53). With respect to the secondary outcomes, no apparent between-group differences were observed in the composite of death from any cause or myocardial infarction (hazard ratio, 1.12; 95% CI, 0.87 to 1.44) or unplanned revascularization (hazard ratio, 0.76; 95% CI, 0.56 to 1.04). There were no apparent between-group differences in safety outcomes. CONCLUSIONS: Among patients with STEMI or very-high-risk NSTEMI and multivessel coronary artery disease, FFR-guided complete revascularization was not shown to result in a lower risk of a composite of death from any cause, myocardial infarction, or unplanned revascularization than culprit-lesion-only PCI at 4.8 years. (Funded by the Swedish Research Council and others; FULL REVASC ClinicalTrials.gov number, NCT02862119.).


Coronary Artery Disease , Fractional Flow Reserve, Myocardial , Myocardial Revascularization , Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Aged , Female , Humans , Male , Middle Aged , Coronary Artery Disease/complications , Coronary Artery Disease/mortality , Coronary Artery Disease/therapy , Follow-Up Studies , Kaplan-Meier Estimate , Myocardial Infarction/mortality , Myocardial Infarction/therapy , Percutaneous Coronary Intervention/methods , Registries , ST Elevation Myocardial Infarction/etiology , ST Elevation Myocardial Infarction/mortality , ST Elevation Myocardial Infarction/physiopathology , ST Elevation Myocardial Infarction/therapy , Myocardial Revascularization/methods , Coronary Vessels/diagnostic imaging , Coronary Vessels/surgery , Reoperation , Europe , Australasia
4.
J Cell Mol Med ; 28(7): e18243, 2024 Apr.
Article En | MEDLINE | ID: mdl-38509740

Humans lacking heme oxygenase 1 (HMOX1) display growth retardation, haemolytic anaemia, and vulnerability to stress; however, cardiac function remains unclear. We aimed to explore the cardiac function of zebrafish lacking hmox1a at baseline and in response to stress. We generated zebrafish hmox1a mutants using CRISPR/Cas9 genome editing technology. Deletion of hmox1a increases cardiac output and further induces hypertrophy in adults. Adults lacking hmox1a develop myocardial interstitial fibrosis, restrain cardiomyocyte proliferation and downregulate renal haemoglobin and cardiac antioxidative genes. Larvae lacking hmox1a fail to respond to hypoxia, whereas adults are insensitive to isoproterenol stimulation in the heart, suggesting that hmox1a is necessary for cardiac response to stress. Haplodeficiency of hmox1a stimulates non-mitochondrial respiration and cardiac cell proliferation, increases cardiac output in larvae in response to hypoxia, and deteriorates cardiac function and structure in adults upon isoproterenol treatment. Intriguingly, haplodeficiency of hmox1a upregulates cardiac hmox1a and hmox1b in response to isoproterenol. Collectively, deletion of hmox1a results in cardiac remodelling and abrogates cardiac response to hypoxia and isoproterenol. Haplodeficiency of hmox1a aggravates cardiac response to the stress, which could be associated with the upregulation of hmox1a and hmox1b. Our data suggests that HMOX1 homeostasis is essential for maintaining cardiac function and promoting cardioprotective effects.


Cardiomyopathies , Heme Oxygenase (Decyclizing) , Animals , Humans , Zebrafish/genetics , Isoproterenol/pharmacology , Heme Oxygenase-1/genetics , Myocardium , Hypoxia , Myocytes, Cardiac
5.
Sci Rep ; 14(1): 3747, 2024 02 14.
Article En | MEDLINE | ID: mdl-38355940

Bone marrow mononuclear cells (BMMCs) have been evaluated for their ability to improve cardiac repair and benefit patients with severe ischemic heart disease and heart failure. In our single-center trial in 2006-2011 we demonstrated the safety and efficacy of BMMCs injected intramyocardially in conjunction with coronary artery bypass surgery. The effect persisted in the follow-up study 5 years later. In this study, we investigated the efficacy of BMMC therapy beyond 10 years. A total of 18 patients (46%) died during over 10-years follow-up and 21 were contacted for participation. Late gadolinium enhancement cardiac magnetic resonance imaging (CMRI) and clinical evaluation were performed on 14 patients, seven from each group. CMRIs from the study baseline, 1-year and 5-years follow-ups were re-analyzed to enable comparison. The CMRI demonstrated a 2.1-fold larger reduction in the mass of late gadolinium enhancement values between the preoperative and the over 10-years follow-up, suggesting less scar or fibrosis after BMMC treatment (- 15.1%; 95% CI - 23 to - 6.7% vs. - 7.3%; 95% CI - 16 to 4.5%, p = 0.039), compared to placebo. No differences in mortality or morbidity were observed. Intramyocardially injected BMMCs may exert long-term benefits in patients with ischemic heart failure. This deserves further evaluation in patients who have received BMMCs in international clinical studies over two decades.


Bone Marrow , Heart Failure , Humans , Follow-Up Studies , Contrast Media , Gadolinium , Bone Marrow Transplantation/methods , Heart Failure/surgery , Cell Transplantation , Treatment Outcome
6.
Int J Cardiol ; 400: 131792, 2024 Apr 01.
Article En | MEDLINE | ID: mdl-38244892

BACKGROUND: ACURATE neo2 (Neo2) implantation is performed after systematic Balloon Aortic Valvuloplasty (BAV) in most patients. No reports exist about the feasibility and safety of direct Neo2 transcatheter aortic valve implantation (TAVI) in comparison to the standard practice. AIM: We aimed to identify the patients' baseline anatomical characteristics, procedural, and early post-procedural outcomes in patients treated using Neo2 with and without BAV. METHODOLOGY: This is a retrospective multicentre analysis of 499 patients with severe aortic stenosis who underwent TAVI using Neo2. The comparison was done according to the performance or omission of BAV. Echocardiography and computed tomography were analysed by an independent Core Lab. Propensity score matching (PSM) was performed based on the annular diameter and AV calcium volume, which identified 84 matched pairs. RESULTS: Among the cohort included, 391 (78%) patients received BAV (BAV-yes) and 108 (22%) were not attempted (BAV-no or Direct TAVI). Patients in BAV-no cohort had smaller annular diameter (22.6 vs 23.4 mm; p < 0.001) and lower calcium volume (163 vs 581 mm3; p < 0.001) compared to BAV-yes cohort. In the matched cohort, VARC-3 device technical success was similar (95%) and all other outcome measures were statistically comparable between cohorts. CONCLUSION: Direct TAVI using ACURATEneo2 without pre-TAVI balloon aortic valvuloplasty in patients with mild or less valve calcifications might be feasible and associated with comparable early outcomes compared to patients with similar anatomical features undergoing systematic balloon valvuloplasty.


Aortic Valve Stenosis , Balloon Valvuloplasty , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Balloon Valvuloplasty/methods , Calcium , Treatment Outcome , Retrospective Studies , Prosthesis Design
7.
Clin J Am Soc Nephrol ; 19(3): 355-363, 2024 03 01.
Article En | MEDLINE | ID: mdl-37962909

BACKGROUND: Cardiovascular diseases are an important cause of mortality in patients who have undergone kidney transplantation, but the knowledge on trends of cardiovascular mortality and specific causes of cardiovascular death among these patients is scarce. METHODS: Our aim was to compare the cardiovascular mortality rates after kidney transplantation in Finland between 1990-1999, 2000-2009, and 2010-2019 using data from the Finnish Registry for Kidney Diseases. We analyzed 1-year and long-term cardiovascular mortality rates as well as the specific causes of cardiovascular death and the trends in them. RESULTS: In total, 4946 patients underwent first kidney transplantation in 1990-2019. During the follow-up time (median 8.3 years, interquartile range 4.0-14.5), there were 1392 deaths, of which 582 were cardiovascular deaths. In an unadjusted Cox regression model, the risk of long-term cardiovascular mortality was similar in the different periods. However, when adjusted for age, sex, duration of dialysis, and cause of kidney disease, the long-term cardiovascular mortality risk was significantly lower in 2000-2009 and 2010-2019 (hazard ratio 0.60 [95% confidence interval, 0.49 to 0.73] and hazard ratio 0.51 [95% confidence interval, 0.39 to 0.66], respectively) compared with 1990-1999. The results were similar regarding 1-year cardiovascular mortality. The distribution of different causes of cardiovascular death remained unchanged during the study period, with coronary artery disease accounting for 47% of deaths. During the first year after transplantation, pulmonary embolisms and arrhythmias were more common than in the long term. CONCLUSIONS: Cardiovascular disease remained the most common cause of death in kidney transplant recipients, but adjusted cardiovascular mortality risk has decreased significantly during the past three decades. Coronary artery disease was the most frequent cause of cardiovascular death, and the proportion of coronary artery disease-related cardiovascular deaths increased after the first year after transplantation.


Cardiovascular Diseases , Coronary Artery Disease , Kidney Transplantation , Humans , Kidney Transplantation/adverse effects , Finland/epidemiology , Coronary Artery Disease/surgery , Coronary Artery Disease/complications , Cardiovascular Diseases/etiology , Cause of Death
8.
Circ J ; 88(4): 462-471, 2024 Mar 25.
Article En | MEDLINE | ID: mdl-38030300

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established treatment for severe aortic stenosis (AS), but despite estimates of life expectancy after TAVI being essential in heart team discussion, these data are scarce. Therefore, the current study sought to assess long-term survival and its trends in relation to chronological age, surgical risk, and treatment period.Methods and Results: We included 2,414 consecutive patients who underwent TAVI for severe symptomatic AS between 2008 and 2021 at 2 international centers. For the analysis, long-term survival was evaluated according to age, surgical risk, and treatment period categorized into 3 groups, respectively. The longest follow-up was 13.5 years. Overall survival was 67.6% at 5 years and 26.9% at 10 years. Younger patients, lower surgical risk, and later treatment period showed better survival (log-rank P<0.001, respectively). In the multivariate analysis, age <75years, lower surgical risk, and later time period were significantly associated with better survival. The incidence of paravalvular leakage ≥moderate, red blood cell transfusion, and acute kidney injury were independently associated with increasing risk of 5-year death. CONCLUSIONS: In a real-world registry, survival was substantial following TAVI, especially in younger and lower surgical-risk patients, with improving outcomes over time. This should be considered in heart team discussions of life-long management for AS patients after TAVI.


Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Humans , Aged , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/surgery , Treatment Outcome , Risk Factors , Heart Valve Prosthesis Implantation/adverse effects , Registries
9.
Am J Cardiol ; 213: 151-160, 2024 Feb 15.
Article En | MEDLINE | ID: mdl-38103766

Preexisting right bundle branch block (RBBB) is the strongest predictor for permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI). However, the risk assessment for new PPI and effective procedural strategy for preventing new PPI in patients with preexisting RBBB are still unclear. This study stratified the new PPI risk after TAVI and investigated the impact of implantation strategy in a preexisting RBBB cohort. We analyzed 237 patients with preexisting RBBB who underwent TAVI. The primary endpoint was the incidence of new PPI. Multivariate analyses investigating predictors for new PPI were performed. The overall PPI rate was 33.3%. Significant baseline predictors for new PPI were combination of RBBB, left anterior or posterior fascicular block, and first-degree atrioventricular block (odds ratio [OR] 2.55, 95% confidence interval [CI] 1.09 to 5.04), high calcium volume of noncoronary cusp (OR 2.08, 95% CI 1.05 to 4.10), and membranous septum (MS) length <2 mm (OR 2.02, 95% CI 1.09 to 3.75) in the univariate analysis and MS length <2 mm (OR 2.25, 95% CI 1.06 to 4.82) in the multivariate analysis. On the multivariate analysis including procedural variables, predilatation (OR 2.41, 95% CI 1.01 to 5.83), self-expanding valves (Corevalve, Evolut R, and Evolut Pro/Pro+; Medtronic Inc., Minneapolis, Minnesota) or mechanical expanding valves (Lotus/Lotus Edge; Boston Scientifics, Marlborough, Massachusetts) (OR 3.00, 95% CI 1.31 to 6.91), and implantation depth > MS length (OR 4.27, 95% CI 1.81 to 10.08) were significantly associated with new PPI. The incidence of new PPI increased according to the number of baseline predictors (0: 20.9%, 1: 34.3%, and ≥2: 52.0%) and procedural predictors (0: 3.7%, 1: 20.9%, 2: 40.5%, and 3: 60.0%). New PPI risk in a preexisting RBBB subset could be stratified by baseline factors. Device selection and implantation strategy considering MS length could prevent new PPI even in these high-risk population.


Aortic Valve Stenosis , Heart Valve Prosthesis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Bundle-Branch Block/epidemiology , Bundle-Branch Block/therapy , Pacemaker, Artificial/adverse effects , Aortic Valve Stenosis/complications , Risk Assessment , Risk Factors , Aortic Valve/surgery , Treatment Outcome , Heart Valve Prosthesis/adverse effects
10.
Am J Cardiol ; 207: 140-149, 2023 11 15.
Article En | MEDLINE | ID: mdl-37738784

The optimal percent oversizing (%OS) using the SAPIEN3 Ultra (S3U) weighing the incidence of paravalvular regurgitation (PVR) ≥ mild against the risk of conduction disturbance (CD) is not known. This study sought to define an optimal extent of the annulus area %OS suitable for transcatheter aortic valve implantation with the S3U compared with the SAPIEN3 (S3). A total of 350 patients with the S3U were compared with 606 patients with the S3. Patients were categorized depending on the degree of %OS. PVR ≥ mild was observed in 8.9% of patients with the S3U and in 21.8% of those with the S3 (p <0.001). The S3U demonstrated a sustainably lower incidence of PVR ≥ mild than the S3 in any extent of %OS. There was an inverse proportional relation between the extent of %OS and frequency of PVR ≥ mild in the S3, whereas the S3U group provided little change. The incidences of PVR ≥ mild were steady >5%OS in the S3 (5% to 10%OS: 13.3%, and >10%OS: 12.1%) and >0%OS in the S3U (0% to 5%OS: 5.9%, 5% to 10%OS: 6.0%, and >10%OS: 6.1%). An increasing %OS was independently associated with the occurrence of CD (<0%OS: 9.8%, 0% to 5%OS: 13.1%, 5% to 10%OS: 16.6%, and >10%OS: 19.2%, p = 0.012). The incidence of PVR ≥ mild and/or CD was the lowest (10.1%) in the 0% to 5%OS in patients with the S3U. In conclusion, the HomoSAPIEN2 study suggests that the S3U tolerates a lesser degree of %OS for mitigating PVR ≥ mild than the S3. Minimal %OS, ranging from 0% to 5%, may be optimal for the S3U with balancing the risk of PVR and CD. Trial Identifier: UMIN000040413/URL: https://center6.umin.ac.jp/cgi-open-bin/ctr/ctr_view.cgi?recptno=R000046115.


Aortic Valve Insufficiency , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/surgery , Aortic Valve Insufficiency/surgery , Hemodynamics , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
11.
J Am Heart Assoc ; 12(15): e029464, 2023 08.
Article En | MEDLINE | ID: mdl-37489732

Background ACURATE neo2 is a transcatheter aortic valve implantation system consisting of a self-expanding bioprosthetic valve with supra-annular leaflet position and featuring innovations to facilitate placement accuracy and reduce paravalvular regurgitation. Methods and Results The goal of the Early neo2 (Early neo2 Registry of the ACURATE neo2 TAVI Prosthesis) was to gather real-life data on safety and efficacy in a European transcatheter aortic valve implantation population treated with ACURATE neo2. Data were collected from 554 consecutive patients treated with ACURATE neo2 at 12 European sites (mean age, 82 years; 66% women; mean European System for Cardiac Operative Risk Evaluation II, 4.5%±3.8%) between September 2020 and March 2021. The composite primary end point was the occurrence of any of the following: postoperative (in-hospital) paravalvular regurgitation grade ≥2, in-hospital acute kidney injury stage 3, postoperative pacemaker implantation, 30-day death, and 30-day stroke. The primary end point occurred in 12.6% of patients. The 30-day rates for all-cause death and all stroke were 1.3% and 2.7%, respectively, and 1.5% of patients exhibited stage 3 acute kidney injury. A total of 34 patients (6.2%) received a postoperative permanent pacemaker. Per core laboratory-adjudicated echocardiographic analysis, mean postoperative aortic valve gradient was 7.6±3.3 mm Hg, and 2.8% of patients exhibited paravalvular regurgitation grade ≥2. Conclusions In this report of postmarket use of the ACURATE neo2 valve in a real-world transcatheter aortic valve implantation population, patients exhibited favorable postoperative hemodynamics and clinical outcomes and a low rate of postoperative pacemaker implantation.


Acute Kidney Injury , Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Humans , Female , Aged, 80 and over , Male , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Prosthesis Design , Treatment Outcome , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Registries , Stroke/epidemiology
12.
Am J Cardiol ; 203: 17-22, 2023 09 15.
Article En | MEDLINE | ID: mdl-37478637

Membranous septum (MS) length, in conjunction with implantation depth (ID), is known as a determinant of conduction disturbance (CD) after transcatheter aortic valve implantation (TAVI). However, its impact might be dissimilar among valve types because each valve has a different platform. This study sought to investigate the different impacts of ID and MS length on the new-onset CD between ACURATE neo and SAPIEN 3. This study included patients without a previous permanent pacemaker implantation who underwent TAVI with ACURATE neo and SAPIEN 3 and divided them into 2 groups based on the ID according to MS length (deep and shallow implantation group). Deep implantation was defined as transcatheter heart valve implantation deeper than MS length. The primary endpoint was new-onset CD (new permanent pacemaker implantation or new-onset complete left bundle branch block). A total of 688 patients (deep implantation: n = 373, shallow implantation: n = 315) were identified as a study cohort. New-onset CD developed more frequently in the deep implantation group (16.6% vs 7.0%; p = 0.0001). Deep implantation was revealed as a predictor of new-onset CD. Moreover, deep implantation was significantly associated with new-onset CD after SAPIEN 3 implantation but not after ACURATE neo. Among patients with MS shorter than 2 mm, ACURATE neo was superior in terms of avoiding new-onset CD. In conclusion, the deep implantation was associated with new-onset CD after TAVI with SAPIEN 3 but not with ACURATE neo. These results may impact device selection in patients with a preexisting high risk of CD.


Aortic Valve Stenosis , Heart Valve Prosthesis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Treatment Outcome , Cardiac Conduction System Disease/complications , Aortic Valve/surgery , Prosthesis Design
13.
J Cardiol Cases ; 27(4): 196-198, 2023 Apr.
Article En | MEDLINE | ID: mdl-37012921

Mucopolysaccharidoses (MPSs) are inherited metabolic diseases characterized by the deficiency of lysosomal enzymes and the accumulation of glycosaminoglycans in various organs, including the heart. In particular, aortic valve disease causes high morbidity and mortality rates, and sometimes requires surgical aortic valve replacement (SAVR) at a young age. Although transcatheter aortic valve replacement (TAVR) for severe aortic stenosis (AS) in surgical high-risk patients is a well-established treatment, there are few reports of TAVR in MPS and medium- and long-term outcomes are not known. We present a case of severe AS in a MPS patient with high risk for SAVR who was successfully treated with TAVR and has shown a fine medium-term result. A 40-year-old woman with MPS type I-HS (Hurler-Scheie syndrome) receiving enzyme replacement therapy as a systemic treatment had complained of syncope and worsening dyspnea, and she was diagnosed with severe AS. The patient had a history of temporary tracheotomy because of the difficulty of endotracheal intubation. Considering risk for general anesthesia, TAVR was performed under local anesthesia. She has improved symptoms for one-and-a-half years. TAVR for severe AS in MPS would be an alternative option for surgical high-risk patients and can demonstrate preferable medium-term outcomes combined with systemic therapies. Learning objective: Mucopolysaccharidoses (MPSs) are metabolic diseases affecting various organs. The MPS patients requiring surgical aortic valve replacement (SAVR) for severe aortic stenosis (AS) often have a high surgical risk. However, in MPS, transcatheter aortic valve replacement (TAVR) could be an alternative procedure to SAVR. We report a MPS patient treated with TAVR showing a preferable medium-term outcome. We suggest that TAVR for severe AS in MPS is an acceptable treatment option.

14.
Am J Cardiol ; 191: 14-22, 2023 03 15.
Article En | MEDLINE | ID: mdl-36623409

The impact of mild paravalvular regurgitation (PVR) after transcatheter aortic valve implantation (TAVI) remains controversial. We evaluated the impact of mild PVR after TAVI on long-term clinical outcomes. We included patients who underwent TAVI for severe symptomatic aortic stenosis between December 2008 and June 2019 at 2 international centers and compared all-cause death between the group with mild PVR (group 1) and the group with none or trace PVR (group 2). PVR was categorized using a 3-class grading scheme, and patients with PVR ≧ moderate and those who were lost to follow-up were excluded. This retrospective analysis included 1,404 patients (mean age 81.7 ± 6.5 years, 58.0% women). Three hundred fifty eight patients (25.5%) were classified into group 1 and 1,046 patients (74.5%) into group 2. At baseline, group 1 was older and had a lower body mass index, worse co-morbidities, and more severe aortic stenosis. To account for these differences, propensity score matching was performed, resulting in 332 matched pairs. Within these matched groups, during a mean follow-up of 3.2 years, group 1 had a significantly lower survival rate at 5 years (group 1: 62.0% vs group 2: 68.0%, log-rank p = 0.029, hazard ratio: 1.41 [95% confidence interval: 1.04 to 1.91]). In the matched cohort, patients with mild PVR had a significant 1.4-fold increased risk of mortality at 5 years after TAVI compared with those with none or trace PVR. Further studies with more patients are needed to evaluate the impact of longer-term outcomes.


Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , Aged, 80 and over , Male , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/complications , Retrospective Studies , Aortic Valve Insufficiency/epidemiology , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/etiology , Treatment Outcome , Aortic Valve/surgery , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/methods , Risk Factors
15.
EuroIntervention ; 18(13): e1066-e1076, 2023 Feb 06.
Article En | MEDLINE | ID: mdl-36440479

BACKGROUND: One-third of patients undergoing transcatheter aortic valve implantation (TAVI) have an indication for long-term oral anticoagulation (OAC). AIMS: We aimed to investigate whether continued non-vitamin K antagonist oral anticoagulant (NOAC) therapy compared with continued vitamin K antagonist (VKA) therapy during TAVI is equally safe and effective.  Methods: Consecutive patients on OAC with either NOAC or VKA undergoing transfemoral TAVI at five European centres were enrolled. The primary outcome measure was a composite of major/life-threatening bleeding, stroke, and all-cause mortality at 30 days. RESULTS: In total, 584 patients underwent TAVI under continued OAC with 294 (50.3%) patients receiving VKA and 290 (49.7%) patients receiving NOAC. At 30 days, the composite primary outcome had occurred in 51 (17.3%) versus 36 (12.4%) patients with continued VKA and with continued NOAC, respectively (odds ratio [OR] 0.68, 95% confidence interval [CI]: 0.43-1.07; p=0.092). Rates of major/life-threatening bleeding (OR 0.87, 95% CI: 0.52-1.47; p=0.606) and stroke (OR 1.02, 95% CI: 0.29-3.59; p=0.974) were not different between groups. In a multivariate Cox regression analysis, continued NOAC, compared with continued VKA, was associated with a lower risk for all-cause 1-year mortality (hazard ratio [HR] 0.61, 95% CI: 0.37-0.98; p=0.043). The analysis of the propensity score-matched cohort revealed similar results. CONCLUSIONS: Continued NOAC compared with continued VKA during TAVI led to comparable outcomes with regard to the composite outcome measure indicating that continued OAC with both drugs is feasible. These hypothesis-generating results need to be confirmed by a dedicated randomised controlled trial.


Atrial Fibrillation , Stroke , Transcatheter Aortic Valve Replacement , Humans , Anticoagulants/therapeutic use , Transcatheter Aortic Valve Replacement/adverse effects , Atrial Fibrillation/drug therapy , Atrial Fibrillation/complications , Stroke/prevention & control , Stroke/complications , Hemorrhage/chemically induced , Fibrinolytic Agents/therapeutic use , Administration, Oral
16.
Cardiovasc Revasc Med ; 47: 62-69, 2023 02.
Article En | MEDLINE | ID: mdl-36114124

BACKGROUND: Comparisons of hemodynamic results between ACURATE Neo and ACURATE Neo 2, which have updated outer sealing skirts, are limited. This retrospective study aimed to demonstrate the differences in hemodynamic outcomes between the two transcatheter heart valves (THVs). METHODS: We included 449 patients who underwent transfemoral transcatheter aortic valve replacement (TAVR) with either ACURATE Neo2 (n = 100) or ACURATE Neo (n = 348) between January 2016 and November 2021. The primary endpoint was the incidence of moderate or severe paravalvular leakage (PVL). The mean aortic pressure gradient (APG), peak aortic velocity (AV), and early clinical outcomes were assessed as secondary outcomes. RESULTS: In the propensity-score matching comparison (94 pairs), there were no significant differences in the incidence of moderate or severe PVL (4.3 % in Neo2 group vs. 8.5 % in Neo group, p = 0.233), and peak AV and mean APG were significantly higher in Neo2 group (Peak AV: 2.1 ± 0.4 vs. 1.9 ± 0.5 m/s, p = 0.003; mean APG: 10.6 ± 4.8 vs. 9.0 ± 6.1 mmHg, p = 0.045). In the multivariate logistic regression analysis, the THV type (ACURATE Neo2) was not an independent predictor of moderate or severe PVL. CONCLUSION: The incidence of moderate or severe PVL did not significantly differ between TAVR with ACURATE Neo2 and ACURATE Neo; however, it was numerically lower in ACURATE Neo2. In contrast, the Neo2 group had a higher residual mean APG and peak AV. A larger study with long-term follow-up is warranted to assess the clinical relevance of these findings.


Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Retrospective Studies , Prosthesis Design , Treatment Outcome , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Hemodynamics
17.
J Cardiothorac Surg ; 17(1): 322, 2022 Dec 18.
Article En | MEDLINE | ID: mdl-36529781

BACKGROUND: Patients with severe aortic stenosis and left ventricular systolic dysfunction have a poor prognosis, and this may result in inferior survival also after aortic valve replacement. The outcomes of transcatheter and surgical aortic valve replacement were investigated in this comparative analysis. METHODS: The retrospective nationwide FinnValve registry included data on patients who underwent transcatheter or surgical aortic valve replacement with a bioprosthesis for severe aortic stenosis. Propensity score matching was performed to adjust the outcomes for baseline covariates of patients with reduced (≤ 50%) left ventricular ejection fraction. RESULTS: Within the unselected, consecutive 6463 patients included in the registry, the prevalence of reduced ejection fraction was 20.8% (876 patients) in the surgical cohort and 27.7% (452 patients) in the transcatheter cohort. Reduced left ventricular ejection fraction was associated with decreased survival (adjusted hazards ratio 1.215, 95%CI 1.067-1.385) after a mean follow-up of 3.6 years. Among 255 propensity score matched pairs, 30-day mortality was 3.1% after transcatheter and 7.8% after surgical intervention (p = 0.038). One-year and 4-year survival were 87.5% and 65.9% after transcatheter intervention and 83.9% and 69.6% after surgical intervention (restricted mean survival time ratio, 1.002, 95%CI 0.929-1.080, p = 0.964), respectively. CONCLUSIONS: Reduced left ventricular ejection fraction was associated with increased morbidity and mortality after surgical and transcatheter aortic valve replacement. Thirty-day mortality was higher after surgery, but intermediate-term survival was comparable to transcatheter intervention. Trial registration The FinnValve registry ClinicalTrials.gov Identifier: NCT03385915.


Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Ventricular Dysfunction, Left , Humans , Aortic Valve/surgery , Aortic Valve Stenosis/complications , Retrospective Studies , Risk Factors , Stroke Volume , Treatment Outcome , Ventricular Dysfunction, Left/complications , Ventricular Function, Left
18.
Int J Mol Sci ; 23(17)2022 Sep 02.
Article En | MEDLINE | ID: mdl-36077457

Hyperactive poly(ADP-ribose) polymerases (PARP) promote ischemic heart failure (IHF) after myocardial infarction (MI). However, the role of tankyrases (TNKSs), members of the PARP family, in pathogenesis of IHF remains unknown. We investigated the expression and activation of TNKSs in myocardium of IHF patients and MI rats. We explored the cardioprotective effect of TNKS inhibition in an isoproterenol-induced zebrafish HF model. In IHF patients, we observed elevated TNKS2 and DICER and concomitant upregulation of miR-34a-5p and miR-21-5p in non-infarcted myocardium. In a rat MI model, we found augmented TNKS2 and DICER in the border and infarct areas at the early stage of post-MI. We also observed consistently increased TNKS1 in the border and infarct areas and destabilized AXIN in the infarct area from 4 weeks onward, which in turn triggered Wnt/ß-catenin signaling. In an isoproterenol-induced HF zebrafish model, inhibition of TNKS activity with XAV939, a TNKSs-specific inhibitor, protected against ventricular dilatation and cardiac dysfunction and abrogated overactivation of Wnt/ß-catenin signaling and dysregulation of miR-34a-5p induced by isoproterenol. Our study unravels a potential role of TNKSs in the pathogenesis of IHF by regulating Wnt/ß-catenin signaling and possibly modulating miRNAs and highlights the pharmacotherapeutic potential of TNKS inhibition for prevention of IHF.


Heart Failure , MicroRNAs , Tankyrases , Animals , Dilatation , Heart Failure/drug therapy , Isoproterenol/pharmacology , MicroRNAs/genetics , Rats , Tankyrases/antagonists & inhibitors , Tankyrases/metabolism , Wnt Signaling Pathway , Zebrafish/metabolism , beta Catenin/metabolism
19.
JACC Cardiovasc Interv ; 15(15): 1543-1554, 2022 08 08.
Article En | MEDLINE | ID: mdl-35926921

BACKGROUND: As transcatheter aortic valve (TAV) replacement is increasingly used in patients with longer life expectancy, a sizable proportion will require redo TAV replacement (TAVR). The unique configuration of balloon-expandable TAV (bTAV) vs a self-expanding TAV (sTAV) potentially affects TAV-in-TAV outcome. OBJECTIVES: The purpose of this study was to better inform prosthesis selection, TAV-in-TAV outcomes were assessed according to the type of initial and subsequent TAV. METHODS: Patients from the Redo-TAVR registry were analyzed using propensity weighting according to their initial valve type (bTAV [n = 115] vs sTAV [n = 106]) and subsequent valve type (bTAV [n = 130] vs sTAV [n = 91]). RESULTS: Patients with failed bTAVs presented later (vs sTAV) (4.9 ± 2.1 years vs 3.7 ± 2.3 years; P < 0.001), with smaller effective orifice area (1.0 ± 0.7 cm2 vs 1.3 ± 0.8 cm2; P = 0.018) and less frequent dominant regurgitation (16.2% vs 47.3%; P < 0.001). Mortality at 30 days was 2.3% (TAV-in-bTAV) vs 0% (TAV-in-sTAV) (P = 0.499) and 1.7% (bTAV-in-TAV) vs 1.0% (sTAV-in-TAV) (P = 0.612); procedural safety was 72.6% (TAV-in-bTAV) vs 71.2% (TAV-in-sTAV) (P = 0.817) and 73.2% (bTAV-in-TAV) vs 76.5% (sTAV-in-TAV) (P = 0.590). Device success was similar according to initial valve type but higher with subsequent sTAV vs bTAV (77.2% vs 64.3%; P = 0.045), primarily because of lower residual gradients (10.3 mm Hg [8.9-11.7 mm Hg] vs 15.2 mm Hg [13.2-17.1 mm Hg]; P < 0.001). Residual regurgitation (moderate or greater) was similar after bTAV-in-TAV and sTAV-in-TAV (5.7%) and nominally higher after TAV-in-bTAV (9.1%) vs TAV-in-sTAV (4.4%) (P = 0.176). CONCLUSIONS: In selected patients, no association was observed between TAV type and redo TAVR safety or mortality, yet subsequent sTAV was associated with higher device success because of lower redo gradients. These findings are preliminary, and more data are needed to guide valve choice for redo TAVR.


Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Humans , Prosthesis Design , Registries , Risk Factors , Treatment Outcome
20.
Am J Cardiol ; 180: 116-123, 2022 Oct 01.
Article En | MEDLINE | ID: mdl-35933223

Despite the development of device technology and operators' experience, access site vascular complications (VCs) remain one of the major concerns after transcatheter aortic valve implantation (TAVI). MANTA (Teleflex, Wayne, Pennsylvania) is a large-bore vascular closure device (VCD) with promising incidence of VC. Previously, we demonstrated that the ultrasound-guided MANTA (US-MANTA) technique further improved the outcomes compared with conventional MANTA (C-MANTA) without ultrasound guidance. The present study was established to prove the effectiveness of the technique in a larger population. In this study, we included 1,150 patients (335 patients with C-MANTA and 815 with US-MANTA) who received MANTA after TAVI from April 2017 to September 2021. The primary endpoint was MANTA-related VC. Overall VC, VCD failure, and bleeding complications were also assessed based on the Valve Academic Research Consortium 3 criteria. MANTA-related VC occurred in 12.5% in the C-MANTA group and 6.8% in the US-MANTA group (p = 0.001). VCD failure rate were 7.5% and 3.9%, respectively (p = 0.012). Valve Academic Research Consortium 3 major and minor VC were more frequent in C-MANTA group (major: 7.8% vs 4.4%, p = 0.023; minor: 8.1% vs 4.4%, p = 0.022). Multivariate analysis revealed US-MANTA as the negative predictor of MANTA-related VC (odds ratio 0.57, 95% confidence interval 0.36 to 0.89, p = 0.013). However, subgroup analysis showed the efficacy of the US-MANTA technique was limited to the patients without severely calcified puncture site (Pinteraction = 0.048). In conclusion, the US-MANTA technique was an effective strategy to reduce VC after transfemoral TAVI compared with C-MANTA.


Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Vascular Closure Devices , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Femoral Artery/surgery , Humans , Treatment Outcome , Ultrasonography, Interventional
...