Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Diabetes Care ; 2024 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-39140891

RESUMEN

OBJECTIVE: We aimed to assess the feasibility, clinical accuracy, and acceptance of a hospital-wide continuous glucose monitoring (CGM) policy with electronic health record (EHR)-integrated validation for insulin dosing. RESEARCH DESIGN AND METHODS: A hospital policy was developed and implemented at Stanford Health Care for using personal CGMs in lieu of fingerstick blood glucose (FSBG) monitoring. It included requirements specific to each CGM, accuracy monitoring protocols, and EHR integration. User experience surveys were conducted among a subset of patients and nurses. RESULTS: From November 2022 to August 2023, 135 patients used the CGM protocol in 185 inpatient encounters. This included 27% with type 1 diabetes and 24% with automated insulin delivery systems. The most-used CGMs were Dexcom G6 (44%) and FreeStyle Libre 2 (43%). Of 1,506 CGM validation attempts, 87.8% met the %20/20 criterion for CGM-based insulin dosing and 99.3% fell within Clarke zones A or B. User experience surveys were completed by 27 nurses and 46 patients. Most nurses found glucose management under the protocol effective (74%), easy to use (67%), and efficient (63%); 80% of nurses preferred inpatient CGM to FSBG. Most patients liked the CGM protocol (63%), reported positive CGM interactions with nursing staff (63%), and felt no significant interruptions to their diabetes management (63%). CONCLUSIONS: Implementation of a hospital-wide inpatient CGM policy supporting multiple CGM types with real-time accuracy monitoring and integration into the EHR is feasible. Initial feedback from nurses and patients was favorable, and further investigation toward broader use and sustainability is needed.

2.
J Diabetes Sci Technol ; : 19322968241267820, 2024 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-39143692

RESUMEN

Automated insulin delivery (AID) systems enhance glucose management by lowering mean glucose level, reducing hyperglycemia, and minimizing hypoglycemia. One feature of most AID systems is that they allow the user to view "insulin on board" (IOB) to help confirm a recent bolus and limit insulin stacking. This metric, along with viewing glucose concentrations from a continuous glucose monitoring system, helps the user understand bolus insulin action and the future "threat" of hypoglycemia. However, the current presentation of IOB in AID systems can be misleading, as it does not reflect true insulin action or automatic, dynamic insulin adjustments. This commentary examines the evolution of IOB from a bolus-specific metric to its contemporary use in AID systems, highlighting its limitations in capturing real-time insulin modulation during varying physiological states.

3.
J Diabetes Sci Technol ; : 19322968241247530, 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38654491

RESUMEN

BACKGROUND: Continuous subcutaneous insulin infusion (CSII) is a common treatment option for people with diabetes (PWD), but insulin infusion failures pose a significant challenge, leading to hyperglycemia, diabetes burnout, and increased hospitalizations. Current CSII pumps' occlusion alarm systems are limited in detecting infusion failures; therefore, a more effective detection method is needed. METHODS: We conducted five preclinical animal studies to collect data on infusion failures, utilizing both insulin and non-insulin boluses. Data were captured using in-line pressure and flow rate sensors, with additional force data from CSII pumps' onboard sensors in one study. A novel classifier model was developed using this dataset, aimed at detecting different types of infusion failures through direct utilization of force sensor data. Performance was compared against various occlusion alarm thresholds from commercially available CSII pumps. RESULTS: The testing dataset included 251 boluses. The Bagging classifier model showed the highest performance metrics among the models tested, exhibiting high accuracy (96%), sensitivity (94%), and specificity (98%), with lower false-positive and false-negative rate compared with traditional occlusion alarm pressure thresholds. CONCLUSIONS: Our study developed a novel non-threshold classifier that outperforms current occlusion alarm systems in CSII pumps in detecting infusion failures. This advancement has the potential to reduce the risk of hyperglycemia and hospitalizations due to undetected infusion failures, offering a more reliable and effective CSII therapy for PWD. Further studies involving human participants are recommended to validate these findings and assess the classifier's performance in a real-world setting.

4.
J Clin Transl Endocrinol ; 36: 100337, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38559803

RESUMEN

Background: People with diabetes have higher COVID-19 morbidity and mortality. These risks are amplified for underserved communities including racial/ethnic minorities and people with lower socioeconomic status. However, limited research has examined COVID-19 outcomes specifically affecting underserved communities with diabetes. Methods: From November 2021 to July 2022, adults with insulin-requiring diabetes at federally qualified health centers in Florida and California (n = 450) completed surveys examining COVID-19 outcomes and demographics. Surveys assessed COVID-19 severity, vaccination uptake, mask-wearing habits, income changes, and healthcare access changes. Surveys also included the full Coronavirus Anxiety Scale (CAS-19). Descriptive statistics were computed for all outcomes. Between-group comparisons for state and race/ethnicity were evaluated via Chi-Squared, Fisher's Exact, Cochran-Mantel-Haenszel, One-Way ANOVA, and t-tests. Logistic regression determined factors associated with COVID-19 vaccination uptake. Data were self-reported and analyzed cross-sectionally. Results: Overall, 29.7 % reported contracting COVID-19; of those, 45.3 % sought care or were hospitalized. Most (81.3 %) received ≥ 1 vaccine. Hispanics had the highest vaccination rate (91.1 %); Non-Hispanic Blacks (NHBs) had the lowest (73.9 %; p =.0281). Hispanics had 4.63x greater vaccination odds than Non-Hispanic Whites ([NHWs]; 95 % CI = [1.81, 11.89]). NHWs least often wore masks (18.8 %; p <.001). Participants reported pandemic-related healthcare changes (62 %) and higher costs of diabetes medications (41 %). Income loss was more frequent in Florida (76 %; p <.001). NHBs most frequently reported "severe" income loss (26.4 %; p =.0124). Loss of health insurance was more common among NHBs (13.3 %; p =.0416) and in Florida (9.7 %; p =.039). COVID-19 anxiety was highest among NHBs and Hispanics (IQR = [0.0, 3.0]; p =.0232) and in Florida (IQR = [0.0, 2.0]; p =.0435). Conclusions: Underserved communities with diabetes had high COVID-19 vaccine uptake but experienced significant COVID-19-related physical, psychosocial, and financial impacts. NHBs and those in Florida had worse outcomes than other racial/ethnic groups and those in California. Further research, interventions, and policy changes are needed to promote health equity for this population.

5.
Chem Sci ; 15(9): 3214-3222, 2024 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-38425513

RESUMEN

We developed a new cysteine-specific solubilizing tag strategy via a cysteine-conjugated succinimide. This solubilizing tag remains stable under common native chemical ligation conditions and can be efficiently removed with palladium-based catalysts. Utilizing this approach, we synthesized two proteins containing notably difficult peptide segments: interleukin-2 (IL-2) and insulin. This IL-2 chemical synthesis represents the simplest and most efficient approach to date, which is enabled by the cysteine-specific solubilizing tag to synthesize and ligate long peptide segments. Additionally, we synthesized a T8P insulin variant, previously identified in an infant with neonatal diabetes. We show that T8P insulin exhibits reduced bioactivity (a 30-fold decrease compared to standard insulin), potentially contributing to the onset of diabetes in these patients. In summary, our work provides an efficient tool to synthesize challenging proteins and opens new avenues for exploring research directions in understanding their biological functions.

6.
Diabetes Technol Ther ; 26(7): 494-497, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38386434

RESUMEN

Background: No published data are available on the use of the community-derived open-source Loop hybrid closed-loop controller ("Loop") by individuals with type 2 diabetes (T2D). Methods: Through social media postings, we invited individuals with T2D currently using the Loop system to join an observational study. Thirteen responded of whom seven were eligible for the study, were using the Loop algorithm, and provided data. Results: Mean (±standard deviation) age was 61 ± 13 years, and mean body mass index was 31 ± 5 kg/m2. All but one participant were using noninsulin glucose-lowering medications. Self-reported mean hemoglobin A1c decreased from 7.3% ± 1.1% before starting Loop to 6.0% ± 0.5% on Loop. Time in range 70-180 mg/dL increased from 84% to 93%. The amount of time in hypoglycemia was extremely low before and with Loop (time <54 mg/dL was 0.04% ± 0.06% vs. 0.09% ± 0.07%, respectively). No severe hypoglycemia or diabetic ketoacidosis events were reported while using Loop. Conclusion: These data, though limited, suggest that the Loop system is likely to be effective when used by individuals with T2D and should be evaluated in large-scale studies. Clinical Trial Registration numbers: NCT05951569.


Asunto(s)
Glucemia , Diabetes Mellitus Tipo 2 , Hipoglucemiantes , Sistemas de Infusión de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/sangre , Persona de Mediana Edad , Femenino , Masculino , Insulina/administración & dosificación , Insulina/uso terapéutico , Anciano , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/uso terapéutico , Glucemia/análisis , Algoritmos , Hemoglobina Glucada/análisis , Automonitorización de la Glucosa Sanguínea , Control Glucémico/métodos , Hipoglucemia/prevención & control , Hipoglucemia/inducido químicamente
7.
bioRxiv ; 2024 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-38168181

RESUMEN

Cadaveric islet and stem cell-derived transplantations hold promise as treatments for type 1 diabetes. To tackle the issue of immunocompatibility, numerous cellular macroencapsulation techniques have been developed that utilize diffusion to transport insulin across an immunoisolating barrier. However, despite several devices progressing to human clinical trials, none have successfully managed to attain physiologic glucose control or insulin independence. Based on empirical evidence, macroencapsulation methods with multilayered, high islet surface density are incompatible with homeostatic, on-demand insulin delivery and physiologic glucose regulation, when reliant solely on diffusion. An additional driving force is essential to overcome the distance limit of diffusion. In this study, we present both theoretical proof and experimental validation that applying pressure at levels comparable to physiological diastolic blood pressure significantly enhances insulin flux across immunoisolation membranes-increasing it by nearly three orders of magnitude. This significant enhancement in transport rate allows for precise, sub-minute regulation of both bolus and basal insulin delivery. By incorporating this technique with a pump-based extravascular system, we demonstrate the ability to rapidly reduce glucose levels in diabetic rodent models, effectively replicating the timescale and therapeutic effect of subcutaneous insulin injection or infusion. This advance provides a potential path towards achieving insulin independence with islet macroencapsulation. One Sentence Summary: Towards improved glucose control, applying sub-minute pressure at physiological levels enhances therapeutic insulin transport from macroencapsulated islets.

8.
Jt Comm J Qual Patient Saf ; 50(1): 66-74, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37718146

RESUMEN

BACKGROUND: The telementoring Project ECHO (Extension for Community Healthcare Outcomes) model has been shown to improve disease management in diabetes in many underserved communities. The authors aim to evaluate if ECHO could also be an effective tool for quality improvement (QI) of diabetes care in these communities. METHODS: Thirteen clinics in underserved communities in California and Florida participating in Project ECHO Diabetes were recruited for a 12-month QI program. The program provided weekly tele-education sessions, including a didactic presentation and case-based discussion. In addition, clinics chose their own set of quality measures to improve and met remotely to discuss their efforts, successes, and setbacks every quarter with mentorship from QI experts. RESULTS: Of the 31 QI initiatives attempted by different clinics, all had either made improvements (25 initiatives, 80.6%) or were in the process of making improvements (6 initiatives, 19.4%) in structural, process, and outcome measures. Examples of these measures include whether clinics have protocols to identify high-risk patients (structure), numbers of continuous glucose monitor prescriptions submitted by the clinics (process), and percentage of patients with diabetes whose most recent HbA1c are > 9% (outcome). For one measure, 40.0% of the clinics had achieved a higher percentage of cumulative HbA1c measurement in the third quarter of the year, compared to the fourth quarter in the previous year. The cost of QI implementation varied widely due to different number of personnel involved across sites. CONCLUSION: A QI program delivered via Project ECHO Diabetes can facilitate quality improvements in underserved communities.


Asunto(s)
Diabetes Mellitus , Mejoramiento de la Calidad , Humanos , Hemoglobina Glucada , Diabetes Mellitus/terapia , Glucemia
9.
JMIR Diabetes ; 8: e46050, 2023 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-37535407

RESUMEN

BACKGROUND: In the United States, there are over 37 million people with diabetes but only 8000 endocrinologists. Therefore, many people with diabetes receive care exclusively from primary care providers (PCPs). To democratize knowledge regarding insulin-requiring diabetes through tele-education, Stanford University and the University of Florida developed Project Extension for Community Healthcare Outcomes (ECHO) Diabetes. OBJECTIVE: ECHO Diabetes uses a Hub and Spoke model connecting specialists (the "Hub") with PCPs (the "Spokes"). One-hour, weekly sessions include Hub diabetes didactic presentations and Spoke deidentified case presentations. Lessons learned during these sessions target provider knowledge and confidence surrounding diabetes management and patient care. METHODS: Spokes were asked to provide short descriptions of people with diabetes whose diabetes management improved directly or indirectly from their providers' participation or their involvement with a Diabetes Support Coach (DSC). We provide a case series to describe individuals and outcomes. Because this study was not a randomized controlled trial and was a prospective observation of patients with the intervention delivered to providers, the trial is not registered in a public trials registry. RESULTS: A case series of 11 people with diabetes was compiled from 10 PCPs and 1 DSC from California and Florida between 2021 and 2022. The principal impact of ECHO Diabetes is the education amplified from PCPs and DSCs to people with diabetes. In all cases, people with diabetes reported increased engagement and improved diabetes management. Several cases reflected increased access to diabetes technology, improvement in glycemic outcomes, and positive trends in mental health measures. CONCLUSIONS: This case series elucidates the potential value of the ECHO Diabetes program to people with diabetes who receive their diabetes care from PCPs. Those matched with a DSC saw clinically significant improvements in hemoglobin A1c and mental health outcomes.

11.
Diabetes Spectr ; 36(2): 127-136, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37193203

RESUMEN

Regular exercise is essential to overall cardiovascular health and well-being in people with type 1 diabetes, but exercise can also lead to increased glycemic disturbances. Automated insulin delivery (AID) technology has been shown to modestly improve glycemic time in range (TIR) in adults with type 1 diabetes and significantly improve TIR in youth with type 1 diabetes. Available AID systems still require some user-initiated changes to the settings and, in some cases, significant pre-planning for exercise. Many exercise recommendations for type 1 diabetes were developed initially for people using multiple daily insulin injections or insulin pump therapy. This article highlights recommendations and practical strategies for using AID around exercise in type 1 diabetes.

12.
Nat Commun ; 14(1): 2729, 2023 05 11.
Artículo en Inglés | MEDLINE | ID: mdl-37169738

RESUMEN

Mounting evidence demonstrates that the central nervous system (CNS) orchestrates glucose homeostasis by sensing glucose and modulating peripheral metabolism. Glucose responsive neuronal populations have been identified in the hypothalamus and several corticolimbic regions. However, how these CNS gluco-regulatory regions modulate peripheral glucose levels is not well understood. To better understand this process, we simultaneously measured interstitial glucose concentrations and local field potentials in 3 human subjects from cortical and subcortical regions, including the hypothalamus in one subject. Correlations between high frequency activity (HFA, 70-170 Hz) and peripheral glucose levels are found across multiple brain regions, notably in the hypothalamus, with correlation magnitude modulated by sleep-wake cycles, circadian coupling, and hypothalamic connectivity. Correlations are further present between non-circadian (ultradian) HFA and glucose levels which are higher during awake periods. Spectro-spatial features of neural activity enable decoding of peripheral glucose levels both in the present and up to hours in the future. Our findings demonstrate proactive encoding of homeostatic glucose dynamics by the CNS.


Asunto(s)
Encéfalo , Glucosa , Humanos , Encéfalo/metabolismo , Glucosa/metabolismo , Hipotálamo/metabolismo , Sistema Nervioso Central/metabolismo , Homeostasis/fisiología
13.
Diabetes Technol Ther ; 25(6): 426-430, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36856574

RESUMEN

Insulin infusion site (IIS) failures are a weakness in insulin pump therapy. We examined experience with IIS failures among U.S. individuals with diabetes on insulin pump through survey distributed to the T1D Exchange Online Community. Demographic factors, IIS characteristics, and diabetes-related perceptions were assessed by logistic regression to determine odds of higher (≥1 per month) or lower (<1 per month) reported IIS failure frequency. IIS failures were common; 41.4% reported ≥1 per month. IIS failure is usually detected through development of hyperglycemia rather than pump alarm. No assessed demographic factor or IIS characteristic was predictive; however, higher odds of ≥1 failure per month were associated with feelings of burnout (odds ratios [OR] 1.489 [1.024, 2.165]) and considering pump discontinuation (OR 2.233 [1.455, 3.427]). IIS failures are frequent and unpredictable, typically require hyperglycemia for detection, and are associated with negative perceptions. More should be done toward preventing IIS failures and/or detecting them sooner.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hiperglucemia , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Insulina/efectos adversos , Hipoglucemiantes/uso terapéutico , Insulina Regular Humana/uso terapéutico , Hiperglucemia/epidemiología , Hiperglucemia/prevención & control , Sistemas de Infusión de Insulina/efectos adversos
15.
J Diabetes Sci Technol ; 17(4): 1085-1120, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36704821

RESUMEN

Diabetes Technology Society hosted its annual Diabetes Technology Meeting from November 3 to November 5, 2022. Meeting topics included (1) the measurement of glucose, insulin, and ketones; (2) virtual diabetes care; (3) metrics for managing diabetes and predicting outcomes; (4) integration of continuous glucose monitor data into the electronic health record; (5) regulation of diabetes technology; (6) digital health to nudge behavior; (7) estimating carbohydrates; (8) fully automated insulin delivery systems; (9) hypoglycemia; (10) novel insulins; (11) insulin delivery; (12) on-body sensors; (13) continuous glucose monitoring; (14) diabetic foot ulcers; (15) the environmental impact of diabetes technology; and (16) spinal cord stimulation for painful diabetic neuropathy. A live demonstration of a device that can allow for the recycling of used insulin pens was also presented.


Asunto(s)
Diabetes Mellitus Tipo 1 , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Glucemia , Automonitorización de la Glucosa Sanguínea , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Tecnología , Hipoglucemiantes/uso terapéutico
16.
J Diabetes Sci Technol ; 17(6): 1440-1447, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-35771004

RESUMEN

AIMS: This study examined the psychosocial impact of Loop, an open-source automated insulin dosing system that has emerged from the diabetes technology "Do-It-Yourself" (DIY) movement. METHODS: Subsamples of 239 adults, 115 children, and 243 parents completed data collection at the time of Loop initiation and 3 and 6 months later. Surveys collected demographic and clinical information, percent time-in-range, HbA1c, and validated psychosocial measures. Analyses included paired t tests and McNemar's tests to compare psychosocial functioning at 3 and 6 months and regression models to assess baseline predictors of psychosocial outcomes at 6 months. RESULTS: Adults reported significant improvements in diabetes distress (t = -7.20 P < .001; t = -8.01, P < .001), sleep quality (t = 6.81, P < .001; t = 2.98, P = .003), fear of hypoglycemia (t = -4.42, P < .001; t = -4.97, P < .001), and hypoglycemia confidence (t = 8.68, P < .001; t = 7.96 P < .001) from baseline to 3 months and 6 months, respectively. Significant improvements in parents' and children's sleep quality and parents' fear of hypoglycemia were also observed. Several baseline characteristics were associated with psychosocial outcomes at 6 months. CONCLUSIONS: The current findings support the broad and sustained benefits of Loop across multiple aspects of psychosocial well-being. Advancement and dissemination of such technologies has the potential to improve mental and physiological health among people living with type 1 diabetes.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Adulto , Niño , Humanos , Insulina , Glucemia/análisis , Sistemas de Infusión de Insulina/psicología , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Hipoglucemia/psicología , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/psicología , Insulina Regular Humana/uso terapéutico , Hipoglucemiantes
18.
J Clin Endocrinol Metab ; 107(11): 2953-2962, 2022 11 23.
Artículo en Inglés | MEDLINE | ID: mdl-36194041

RESUMEN

OBJECTIVE: This work aims to guide clinicians practicing endocrinology in the use of telehealth (synchronous patient-clinician visits conducted over video or telephone) for outpatient care. PARTICIPANTS: The Endocrine Society convened a 9-member panel of US endocrinologists with expertise in telehealth clinical care, telehealth operations, patient-centered care, health care delivery research, and/or evidence-based medicine. EVIDENCE: The panel conducted a literature search to identify studies published since 2000 about telehealth in endocrinology. One member extracted a list of factors affecting the quality of endocrine care via telehealth from the extant literature. The panel grouped these factors into 5 domains: clinical, patient, patient-clinician relationship, clinician, and health care setting and technology. CONSENSUS PROCESS: For each domain, 2 or 3 members drew on existing literature and their expert opinions to draft a section examining the effect of the domain's component factors on the appropriateness of telehealth use within endocrine practice. Appropriateness was evaluated in the context of the 6 Institute of Medicine aims for health care quality: patient-centeredness, equity, safety, effectiveness, timeliness, and efficiency. The panel held monthly virtual meetings to discuss and revise each domain. Two members wrote the remaining sections and integrated them with the domains to create the full policy perspective, which was reviewed and revised by all members. CONCLUSIONS: Telehealth has become a common care modality within endocrinology. This policy perspective summarizes the factors determining telehealth appropriateness in various patient care scenarios. Strategies to increase the quality of telehealth care are offered. More research is needed to develop a robust evidence base for future guideline development.


Asunto(s)
Endocrinología , Telemedicina , Humanos , Medicina Basada en la Evidencia , Atención Ambulatoria , Políticas
19.
Diabetes Technol Ther ; 24(9): 628-634, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35856740

RESUMEN

Objective: The German/Austrian Diabetes Patient Follow-up Registry (Diabetes-Patienten-Verlaufsdokumentation or DPV), England/Wales National Pediatric Diabetes Audit (NPDA), and Type 1 Diabetes Exchange (T1DX) in the United States investigated changes in hemoglobin A1c (HbA1c) and diabetes technology use from 2010 to 2018. Methods: Registry/audit data from 2010 to 2018 were analyzed in annual cohorts using linear regression for those <18 years of age with type 1 diabetes diagnosed at age >6 months. Time trends in HbA1c, pump, and continuous glucose monitoring (CGM) use were studied using repeated measurements linear and logistic regression models with an autoregressive covariance structure and with year and data source as independent variables. Results: A total of 1,172,980 visits among 114,264 (54,119 DPV, 43,550 NPDA, 16,595 T1DX) patients were identified. HbA1c remained clinically stable in DPV (7.7% [61 mmol/mol] to 7.6% [60 mmol/mol]), decreased in the NPDA (8.7% [72 mmol/mol] to 7.9% [63 mmol/mol]), and increased in T1DX (8.0% [64 mmol/mol] to 8.5% [69 mmol/mol] from 2010 to 2018). In all registries/audits, insulin pump and CGM use increased over time with greatest pump use in T1DX and lowest uptake reported in NPDA. Conclusions: These data reveal three different longitudinal patterns of change in registry/audit HbA1c from 2010 to 2018. Diabetes technology use increased throughout, at different rates. Quality improvement (QI) programs in DPV have been ongoing for 25 years, began in NPDA in 2009 and T1DX in 2016. We speculate that in England/Wales, development of networks, peer review, and implementation of QI measures contributed to reductions in population HbA1c. Many of these interventions had been implemented in DPV before 2010. Further efforts to understand this improvement, including the role of QI, and continued success within standardized documentation and benchmarking could inform T1DX programs to reduce HbA1c.


Asunto(s)
Diabetes Mellitus Tipo 1 , Glucemia , Automonitorización de la Glucosa Sanguínea , Niño , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/epidemiología , Hemoglobina Glucada/análisis , Humanos , Lactante , Estudios Prospectivos , Sistema de Registros , Tecnología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA