Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Phlebology ; 38(8): 532-539, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37436708

RESUMEN

OBJECTIVE: This study aimed to compare patient-reported outcomes after technical success (TS) and technical failure (TF) in treating great saphenous vein incompetence (GSV) with ClariVein. METHODS: A subanalysis of a previous trial was conducted on symptomatic GSV incompetence patients who received ClariVein treatment with 2% or 3% polidocanol (POL) and were followed for 6 months. Blinding was implemented for observers and patients, and data from both POL groups were combined. TS was defined as at least 85% occlusion of the treated vein, while TF indicated failure to meet TS criteria. Secondary outcomes included Venous Clinical Severity Score (VCSS), Aberdeen Varicose Vein Questionnaire (AVVQ), and Short-Form 36 Health Survey Questionnaire (SF-36). RESULTS: Among the 364 patients included, the TS rate was 64.5%. Comparison of VCSS, AVVQ, and SF-36 scores between TS and TF groups did not yield significant differences. CONCLUSION: This study indicates no significant variation in VCSS, AVVQ, and SF-36 scores between patients experiencing TS and TF following ClariVein treatment for GSV insufficiency.


Asunto(s)
Procedimientos Endovasculares , Várices , Insuficiencia Venosa , Humanos , Polidocanol , Vena Safena/diagnóstico por imagen , Resultado del Tratamiento , Várices/terapia , Medición de Resultados Informados por el Paciente , Insuficiencia Venosa/terapia , Calidad de Vida
2.
J Vasc Surg Venous Lymphat Disord ; 10(4): 856-864.e2, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-34781008

RESUMEN

BACKGROUND: The purpose of the present study was to identify the ideal polidocanol (POL) concentration for mechanochemical ablation (MOCA) of the great saphenous vein (GSV) using the ClariVein system (Merit Medical, South Jordan, Utah). METHODS: We performed a multicenter, randomized, controlled, single-blind trial with a follow-up period of 6 months. Patients with symptomatic primary truncal GSV incompetence were randomized to MOCA + 2% POL liquid (2% group) or MOCA + 3% POL liquid (3% group). The primary outcome was technical success (TS), defined as an open part of the treated vein segment of ≤10 cm in length. The secondary outcomes were alternative TS, defined as ≥85% occlusion of the treated vein segment, postoperative pain, venous clinical severity scores, Aberdeen varicose vein questionnaire scores, and short-form 36-item health survey questionnaire scores, and complications. RESULTS: From 2012 to 2018, 364 patients (375 limbs) were included, of which, 189 limbs were randomly allocated to the 2% group and 186 to the 3% group. The TS rate at 6 months was 69.8% in the 2% group vs 78.0% in the 3% group (P = .027). A higher overall TS rate was seen in GSVs of ≤5.9 mm compared with GSVs >5.9 mm (84.3% vs 59.5%, respectively; P < .001). The alternative TS rate at 6 months was 61.4% in the 2% group and 67.7% in the 3% group (P = .028). The venous clinical severity scores, Aberdeen varicose vein questionnaire scores, and most short-form 36-item health survey questionnaire domains had improved in both groups (P < .002). Postprocedural pain was low. Two pulmonary embolisms and two deep vein thromboses were seen. Superficial venous thrombosis had occurred more often in the 3% group (18 vs 8 in the 2% group; P = .033). CONCLUSIONS: The results from the present study showed a higher success rate for MOCA with 3% POL liquid than for MOCA with 2% POL liquid at 6 months of follow-up. However, the difference in quality of life was not significant. Long-term follow-up studies are required to investigate whether these results will be sustained in the future.


Asunto(s)
Procedimientos Endovasculares , Várices , Insuficiencia Venosa , Procedimientos Endovasculares/métodos , Humanos , Polidocanol/efectos adversos , Vena Safena/diagnóstico por imagen , Vena Safena/cirugía , Método Simple Ciego , Resultado del Tratamiento , Várices/diagnóstico por imagen , Várices/cirugía , Insuficiencia Venosa/diagnóstico por imagen , Insuficiencia Venosa/cirugía
3.
Phlebology ; 33(7): 483-491, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28795613

RESUMEN

Background The aim of this study was to assess whether venous occlusion plethysmography can be used to identify venous obstruction and predict clinical success of stenting. Method Receiver operated characteristic curves were used to determine the ability of venous occlusion plethysmography to discriminate between the presence and absence of obstruction, measured by duplex ultrasound and magnetic resonance venography, and to discriminate between successful and non-successful stenting, measured by VEINES-QOL/Sym. Result Two hundred thirty-seven limbs in 196 patients were included. Areas under the curve for post-thrombotic obstruction were one-second outflow volume 0.71, total venous volume 0.69 and outflow fraction 0.59. Stenting was performed in 45 limbs of 39 patients. Areas under the curve for identifying patients with successful treatment at one year after stenting were 0.57, 0.54 and 0.63, respectively. Conclusion Venous occlusion plethysmography cannot be used to identify venous obstruction proximal to the femoral confluence or to distinguish which patients will benefit from treatment.


Asunto(s)
Stents , Enfermedades Vasculares/fisiopatología , Enfermedades Vasculares/cirugía , Adulto , Constricción Patológica/diagnóstico por imagen , Constricción Patológica/fisiopatología , Constricción Patológica/cirugía , Femenino , Humanos , Angiografía por Resonancia Magnética , Masculino , Persona de Mediana Edad , Flebografía , Pletismografía , Estudios Retrospectivos , Enfermedades Vasculares/diagnóstico por imagen
4.
Expert Rev Med Devices ; 14(10): 755-762, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28892412

RESUMEN

INTRODUCTION: The treatment of incompetent truncal veins has been innovated by the introduction of minimally invasive non-thermal non-tumescent (NTNT) techniques. One of these consists of the use of cyanoacrylate glue to occlude the vein lumen by means of the VenaSeal device. Areas covered: This expert-review aims to evaluate NTNT ablation of incompetent saphenous trunks using the VenaSeal device. Expert commentary: Cyanoacrylate adhesive embolization of incompetent truncal veins using the VenaSeal device is a safe and efficacious innovative technique. Further studies are needed to evaluate anatomical and clinical outcomes at long term.


Asunto(s)
Cianoacrilatos/administración & dosificación , Embolización Terapéutica/métodos , Vena Safena , Várices/terapia , Animales , Embolización Terapéutica/efectos adversos , Humanos , Terapia por Láser , Resultado del Tratamiento
6.
Phlebology ; 29(1 suppl): 49-54, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24843086

RESUMEN

Consideration of treating incompetent perforating veins remains a conundrum based on scientific evidence available till date. While subfascial endoscopic perforator surgery (SEPS) proved to be a worthy alternative for open surgery, other even less invasive techniques were being introduced by the late nineties of the last century. Percutaneous thermo-ablation techniques are still being used today and seem more effective than non-thermal techniques. However, thermal techniques require anaesthesia and potentially may cause inadvertent damage to surrounding tissues such as nerves. Cyanoacrylate adhesive has a proven record, but not for the treatment of chronic venous disease of the leg. Innovation has led to the development of the VenaSeal® Sapheon Closure System which has been designed to use a modified cyanoacrylate glue as a new therapy for truncal vein incompetence. This paper explores the feasibility of ultrasound guided cyanoacrylate adhesive perforator embolization (CAPE). Results show a 76% occlusion rate of incompetent perforating veins without serious complications leading to the conclusion that further investigation with a dedicated delivery device in a larger patient population is warranted.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...