Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Ultramicroscopy ; 235: 113497, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35193073

RESUMEN

The development of ultrafast electron microscopy (UEM), specifically stroboscopic imaging, has brought the study of structural dynamics to a new level by overcoming the spatial limitations of ultrafast spectroscopy and the temporal restrictions of traditional TEM simultaneously. Combining the concepts governing both techniques has enabled direct visualization of dynamics with spatiotemporal resolutions in the picosecond-nanometer regime. Here, we push the limits of imaging using a pulsed electron beam via RF induced transverse deflection based on the newly developed 200 keV frequency-tunable strip-line pulser. We demonstrate a 0.2 nm spatial resolution and elucidation of magnetic spin induction maps using the phase-microscopy method. We also present beam coherence measurements and expand our study using the breathing modes of a silicon interdigitated comb under RF excitation which achieves improved temporal synchronization between the electron pulse-train and electric field. A new RF holder has also been developed with impedance matching to the RF signal to minimize transmission power loss to samples and its performance is compared with a conventional sample holder.

2.
Microsc Microanal ; : 1-17, 2021 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-33908340

RESUMEN

This work introduces NexusLIMS, an electron microscopy laboratory information management system designed and implemented by the Office of Data and Informatics and the Materials Science and Engineering Division at NIST for a multi-user electron microscopy co-op facility. NexusLIMS comprises network infrastructure, shared information technology resources, a custom software package to harvest and extract experimental information and construct experimental metadata records, and an intuitive web-based user-facing interface for searching, browsing, and examining research data. These metadata records conform to the Nexus Experiment schema, which is introduced in this work. The NexusLIMS suite of tools requires minimal input and adjustments to user behavior, instead relying on existing organizational procedures and the collection of information from a multitude of sources to construct a complete picture and record of a research experiment. The underlying infrastructure and design considerations for a multi-user data management system are discussed. The core codebase for NexusLIMS is made publicly available alongside this work, and its modular design encourages the adaptation of the presented methods at other research organizations.

3.
Sci Adv ; 6(40)2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33008895

RESUMEN

Integrating femtosecond lasers with electron microscopies has enabled direct imaging of transient structures and morphologies of materials in real time and space. Here, we report the development of a laser-free ultrafast electron microscopy (UEM) offering the same capability but without requiring femtosecond lasers and intricate instrumental modifications. We create picosecond electron pulses for probing dynamic events by chopping a continuous beam with a radio frequency (RF)-driven pulser with the pulse repetition rate tunable from 100 MHz to 12 GHz. As a first application, we studied gigahertz electromagnetic wave propagation dynamics in an interdigitated comb structure. We reveal, on nanometer space and picosecond time scales, the transient oscillating electromagnetic field around the tines of the combs with time-resolved polarization, amplitude, and local field enhancement. This study demonstrates the feasibility of laser-free UEM in real-space visualization of dynamics for many research fields, especially the electrodynamics in devices associated with information processing technology.

4.
Sci Rep ; 10(1): 18435, 2020 10 28.
Artículo en Inglés | MEDLINE | ID: mdl-33116197

RESUMEN

The role of zinc in neurobiology is rapidly expanding. Zinc is especially essential in olfactory neurobiology. Naturally occurring zinc nanoparticles were detected in olfactory and nasal respiratory epithelia and cilia in animals. The addition of these nanoparticles to a mixture of odorants, including ethyl butyrate, eugenol, and carvone, considerably increased the electrical responses of the olfactory sensory receptors. Studies of these nanoparticles by ransmission electron microscopy (TEM) and selected area electron diffraction revealed metal elemental crystalline zinc nanoparticles 2-4 nm in diameter. These particles did not contain oxidized zinc. The enhancement of the odorant responses induced by the endogenous zinc nanoparticles appears to be similar to the amplification produced by engineered zinc nanoparticles. Zinc nanoparticles produce no odor response but increase odor response if mixed with an odorant. These effects are dose-dependent and reversible. Some other metal nanoparticles, such as copper, silver, gold, and platinum, do not have the effects observed in the case of zinc nanoparticles. The olfactory enhancement was observed in young and mature mouse olfactory epithelium cultures, in the dissected olfactory epithelium of rodents, and in live conscious dogs. The physiological significance of the detected endogenous metal nanoparticles in an animal tissue has been demonstrated for the first time. Overall, our results may advance the understanding of the initial events in olfaction.


Asunto(s)
Cilios/química , Mucosa Olfatoria/química , Olfato/fisiología , Zinc/fisiología , Animales , Masculino , Nanopartículas/análisis , Ratas Sprague-Dawley , Zinc/análisis
5.
Rev Sci Instrum ; 91(2): 021301, 2020 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-32113442

RESUMEN

A 300 keV transmission electron microscope was modified to produce broadband pulsed beams that can be, in principle, between 40 MHz and 12 GHz, corresponding to temporal resolution in the nanosecond to picosecond range without an excitation laser. The key enabling technology is a pair of phase-matched modulating and de-modulating traveling wave metallic comb striplines (pulsers). An initial temporal resolution of 30 ps was achieved with a strobe frequency of 6.0 GHz. The placement of the pulsers, mounted immediately below the gun, allows for preservation of all optical configurations, otherwise available to the unmodified instrument, and therefore makes such a post-modified instrument for dual-use, i.e., both pulsed-beam mode (i.e., stroboscopic time-resolved) and conventional continuous waveform mode. In this article, we describe the elements inserted into the beam path, challenges encountered during integration with an in-service microscope, and early results from an electric-field-driven pump-probe experiment. We conclude with ideas for making this class of instruments broadly applicable for examining cyclical and repeatable phenomena.

6.
Artículo en Inglés | MEDLINE | ID: mdl-34877182

RESUMEN

An evaluation of the feasibility and the requirements associated with a facility-wide deployment of a laboratory information management system (LIMS) at an electron microscopy facility was conducted. 4CeeD, an open-source LIMS, was selected for the focus study. This report summarizes data infrastructure prerequisites, critical and desirable features, and lessons learned from using and interacting with 4CeeD, and broader LIMS adoption recommendations for this facility.

8.
ACS Appl Mater Interfaces ; 10(29): 24725-24732, 2018 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-29972304

RESUMEN

The magnetoelastic behavior of multiferroic heterostructures-coupling of magnetic anisotropy or domain dynamics to structural deformations-has been intensively studied for developing materials for energy-efficient, spin-based applications. Here, we report on a large, interface-dominated magnetostriction in (Co/Ni)4/Pb(Mg1/3Nb2/3)O3-PbTiO3 multiferroic heterostructures. Ferromagnetic resonance spectroscopy under voltage-induced strains enabled estimation of the saturation magnetostriction as a function of Ni thickness. The volume and the interface components to the saturation magnetostriction are (6.6 ± 0.9) × 10-6 and (-2.2 ± 0.2) × 10-14 m, respectively. Similar to perpendicular magnetic anisotropy in Co/Ni, the large, negative magnetostriction originates from the Co/Ni interfaces. This interfacial functionality delivers an effect over 300% larger than the bulk contribution and can enable low-energy, nanoelectronic devices that combine the tunable magnetic and magnetostrictive properties of Co/Ni multilayers with the ferroelectric properties of Pb(Mg1/3Nb2/3)O3-PbTiO3.

9.
PLoS One ; 12(12): e0189273, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29261701

RESUMEN

Olfactory responses are intensely enhanced with the addition of endogenous and engineered primarily-elemental small zinc nanoparticles (NPs). With aging, oxidation of these Zn nanoparticles eliminated the observed enhancement. The design of a polyethylene glycol coating to meet storage requirements of engineered zinc nanoparticles is evaluated to achieve maximal olfactory benefit. The zinc nanoparticles were covered with 1000 g/mol or 400 g/mol molecular weight polyethylene glycol (PEG). Non-PEGylated and PEGylated zinc nanoparticles were tested by electroolfactogram with isolated rat olfactory epithelium and odorant responses evoked by the mixture of eugenol, ethyl butyrate and (±) carvone after storage at 278 K (5 oC), 303 K (30 oC) and 323 K (50 oC). The particles were analyzed by atomic force microscopy, transmission electron microscopy, X-ray photoelectron spectroscopy, and laser Doppler velocimetry. Our data indicate that stored ZnPEG400 nanoparticles maintain physiologically-consistent olfactory enhancement for over 300 days. These engineered Nanoparticles support future applications in olfactory research, sensitive detection, and medicine.


Asunto(s)
Nanopartículas del Metal/química , Odorantes , Mucosa Olfatoria/efectos de los fármacos , Polietilenglicoles/química , Zinc/química , Microscopía de Fuerza Atómica , Microscopía Electrónica de Transmisión , Espectroscopía de Fotoelectrones
10.
Biometals ; 29(6): 1005-1018, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27649965

RESUMEN

Electrical responses of olfactory sensory neurons to odorants were examined in the presence of zinc nanoparticles of various sizes and degrees of oxidation. The zinc nanoparticles were prepared by the underwater electrical discharge method and analyzed by atomic force microscopy and X-ray photoelectron spectroscopy. Small (1.2 ± 0.3 nm) zinc nanoparticles significantly enhanced electrical responses of olfactory neurons to odorants. After oxidation, however, these small zinc nanoparticles were no longer capable of enhancing olfactory responses. Larger zinc oxide nanoparticles (15 nm and 70 nm) also did not modulate responses to odorants. Neither zinc nor zinc oxide nanoparticles produced olfactory responses when added without odorants. The enhancement of odorant responses by small zinc nanoparticles was explained by the creation of olfactory receptor dimers initiated by small zinc nanoparticles. The results of this work will clarify the mechanisms for the initial events in olfaction, as well as to provide new ways to alleviate anosmia related to the loss of olfactory receptors.


Asunto(s)
Nanopartículas del Metal/química , Odorantes , Neuronas Receptoras Olfatorias/efectos de los fármacos , Zinc/química , Zinc/farmacología , Animales , Electrofisiología/métodos , Masculino , Microscopía de Fuerza Atómica , Microscopía Electrónica de Transmisión , Neuronas Receptoras Olfatorias/fisiología , Espectroscopía de Fotoelectrones , Ratas Sprague-Dawley , Receptores Odorantes/química , Óxido de Zinc/química , Óxido de Zinc/farmacología
11.
Ultramicroscopy ; 161: 130-136, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26683815

RESUMEN

A device and a method for producing ultrashort electron pulses with GHz repetition rates via pulsing an input direct current (dc) electron beam are provided. The device and the method are based on an electromagnetic-mechanical pulser (EMMP) that consists of a series of transverse deflecting cavities and magnetic quadrupoles. The EMMP modulates and chops the incoming dc electron beam and converts it into pico- and sub-pico-second electron pulse sequences (pulse trains) at >1GHz repetition rates, as well as controllably manipulates the resulting pulses. Ultimately, it leads to negligible electron pulse phase-space degradation compared to the incoming dc beam parameters. The temporal pulse length and repetition rate for the EMMP can be continuously tunable over wide ranges. Applying the EMMP to a transmission electron microscope (TEM) with any dc electron source (e.g. thermionic, Schottky, or field-emission source), a GHz stroboscopic high-duty-cycle TEM can be realized. Unlike in many recent developments in time-resolved TEM that rely on a sample pumping laser paired with a laser launching electrons from a photocathode to probe the sample, there is no laser in the presented experimental set-up. This is expected to be a significant relief for electron microscopists who are not familiar with laser systems. The EMMP and the sample are externally driven by a radiofrequency (RF) source synchronized through a delay line. With no laser pumping the sample, the problem of the pump laser induced residual heating/damaging the sample is eliminated. As many RF-driven processes can be cycled indefinitely, sampling rates of 1-50GHz become accessible. Such a GHz stroboscopic TEM would open up a new paradigm for in situ and in operando experiments to study samples externally driven electromagnetically. Complementary to the lower (MHz) repetition rates experiments enabled by laser photocathode TEM, new experiments in the multi-GHz regime will be enabled by the proposed RF design. Because TEM is also a platform for various analytical methods, there are infinite application opportunities in energy and electronics to resolve charge (electronic and ionic) transport, and magnetic, plasmonic and excitonic dynamics in advanced functional materials. In addition, because the beam duty-cycle can be as high as ~10(-1) (or 10%), detection can be accomplished by commercially available detectors. In this article, we report an optimal design of the EMMP. The optimal design was found using an analytical generalized matrix approach in the thin lens approximation along with detailed beam dynamics taking actual realistic dc beam parameters in a TEM operating at 200keV.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...