Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 11 de 11
1.
Cardiol J ; 30(1): 6-11, 2023.
Article En | MEDLINE | ID: mdl-36510793

Percutaneous coronary intervention (PCI) of chronic total occlusions (CTO) in coronary bifurcation lesions (CBL) is undergoing substantial technical progress and standardization, paralleling the evolution of dedicated devices, tools, and techniques. A standard consensus to classify CTO-CBL might be instrumental to homogenize data collection and description of procedures for scientific and educational purposes. The Medina-CTO classification replicates the classical three digits in Medina classification for bifurcations, representing the proximal main vessel, distal main vessel, and side branch, respectively. Each digit can take a value of 1 if it concerns atherosclerosis and is anatomically stenosed, or 0 if it is not. In addition, the occluded segment(s) of the bifurcation are noted by a subscript, which describes key interventional features of the cap: t (tapered), b (blunt), or a (ambiguous). This approach results in 56 basic categories that can be grouped by means of different elements, depending on the specific needs of each study. Medina-CTO classification, consisting of adding a subscript describing the basic cap characteristics to the totally occluded segment(s) of the standard Medina triplet, might be a useful methodological tool to standardize percutaneous intervention of bifurcational CTO lesions, with interesting scientific and educational applications.


Coronary Occlusion , Percutaneous Coronary Intervention , Humans , Percutaneous Coronary Intervention/methods , Coronary Angiography/methods , Chronic Disease , Treatment Outcome
2.
Front Cardiovasc Med ; 9: 861129, 2022.
Article En | MEDLINE | ID: mdl-35369311

Aim: The aim of this study was to explore the potential intraprocedural benefits of the Proximal Side Optimization (PSO) technique by Optical Coherence Tomography (OCT). Methods: A case series of 10 consecutive true bifurcation lesions, with severe long pathology of long side branch (SB), were randomly assigned to be treated by standard DK Crush procedure (non-PSO group) as compared to DK Crush in PSO modification (PSO group). The data from OCT investigation before crushing of the SB Drug-Eluting Stent (DES), after crushing, after first kissing balloon inflation (KBI), and after final angiography were compared between the two groups (Public trials registry ISRCTN23355755). Results: All 10 cases were successfully treated by the assigned technique. The two groups were similar in terms of indications for the procedure, bifurcation angle, and stent dimensions. As compared to the non-PSO, the PSO group showed larger proximal SB stent areas (5.8 ± 1.8 vs. 4.5 ± 0.5 mm2; p = 0.02), the larger delta between distal and proximal stent areas before crush (1.5 ± 0.7 vs. 0.6 ± 0.5 mm2; p = 0.004), and the larger Space of Optimal Wiring (SOW) after Crush (5.3 ± 1.8 vs. 2.5 ± 1.1 mm2; p = 0.02). The gaps in scaffolding within the ostial segment of the Side Branch DES were found in two patients from the non-PSO group. Conclusion: The DK Crush in PSO modification results in larger SB DES and SOW areas with better apposition to the vessel wall. As result, the SB DES acquires a funnel shape, which reduces the risk of passage outside the SB stent struts during re-wiring, thus, allowing predictable and secure results.

3.
Cardiovasc Revasc Med ; 28: 88-91, 2021 07.
Article En | MEDLINE | ID: mdl-32958440

Provisional single drug-eluting stent (DES) strategy remains the standard of care in simple bifurcation lesions which comprise the vast majority of coronary bifurcations. Nevertheless, the presence of complex bifurcations which are defined based on the 1) Side Branch (SB) lesion length of >10 mm and 2) SB ostial diameter stenosis of >70% are approached with a 2-DES strategy upfront. The bifurcation angle will further define the most appropriate technique, with T-stenting more suitable in angulations close to 90°, Culotte and the family of Crush techniques more appropriate for acute angles of <75°. The Crush techniques which are composed of the classic Crush, mini-Crush and double kissing Crush (DK-Crush) share the core principle of protruding the SB DES within the Main Branch (MB) to minimize the risk of ostial SB restenosis, which remains the most prevalent etiology of stent failure during 2-stent approach in bifurcations. Proximal Side Optimization (PSO) is an additional technical consideration to further optimize the protruding SB struts enabling 1) optimal SB strut accommodation to the larger MB vessel diameter, 2) strut enlargement that will further facilitate effortless rewiring for kissing balloon inflation (KBI) avoiding unfavorable guide wire advancement in the peri-ostial SB area.


Angioplasty, Balloon, Coronary , Drug-Eluting Stents , Humans , Silicones , Stents
4.
EuroIntervention ; 17(2): e140-e148, 2021 Jun 11.
Article En | MEDLINE | ID: mdl-32928714

BACKGROUND: The ability of optical coherence tomography (OCT) to identify specific types of stent has never been systematically studied. AIMS: The aim of this study was to test the accuracy of OCT imaging to identify patterns of stent platform and subsequently identify the type of stent implanted. METHODS: Consecutive patients from six international centres were retrospectively screened, searching for OCT studies with metallic stents or scaffolds. The sample was analysed by two blinded operators, applying a dedicated protocol in four steps to identify the type of stent: 1) 3D and automatic strut detection (ASD), 2) 3D tissue view, 3) longitudinal view with ASD, 4) mode "stent only" and ASD. RESULTS: A series of 212 patients underwent OCT in the study centres, finding 294 metallic stents or scaffolds in 146 patients. The protocol correctly identified 285 stents (96.9%, kappa 0.965), with excellent interobserver agreement (kappa 0.988). The performance tended to be better in recently implanted stents (kappa 0.993) than in stents implanted ≥3 months before (kappa 0.915), and in pullback speed 18 mm/s as compared with 36 mm/s (kappa 0.969 vs 0.940, respectively). CONCLUSIONS: The type of stent platform can be accurately identified in OCT by trained analysts following a dedicated protocol, combining 3D-OCT, ASD and longitudinal view. This might be clinically helpful in scenarios of device failure and for the quantification of apposition. The blinding of analysts in OCT studies should be revisited.


Stents , Tomography, Optical Coherence , Coronary Vessels , Humans , Retrospective Studies
6.
Cardiovasc Revasc Med ; 21(12): 1596-1605, 2020 12.
Article En | MEDLINE | ID: mdl-32546382

Coronary artery bypass surgery has been the accepted treatment for left main coronary artery disease for over 50 years. Balloon angioplasty was later used then abandoned because of deaths likely due to restenosis or thrombotic occlusion. However, rapid innovations in drug-eluting stent designs leading to more biocompatible thin strut platforms with optimal drug elution profiles and further advances in modern pharmacotherapy involving potent P2Y12 inhibitors combined with utilization of intracoronary imaging and physiologic assessment for procedural planning and optimization have transformed percutaneous interventions into successful alternatives to coronary artery bypass graft surgery (CABG) in selected LM anatomic territories. Herein, we provide an evidence-based practical guide on how to approach and perform LM percutaneous interventions (PCI).


Coronary Artery Disease , Percutaneous Coronary Intervention , Coronary Artery Bypass , Drug-Eluting Stents , Humans , Treatment Outcome
7.
Eur Heart J ; 41(27): 2523-2536, 2020 07 14.
Article En | MEDLINE | ID: mdl-32588060

AIM: The present study aimed to assess the benefits of two-stent techniques for patients with DEFINITION criteria-defined complex coronary bifurcation lesions. METHODS AND RESULTS: In total, 653 patients with complex bifurcation lesions at 49 international centres were randomly assigned to undergo the systematic two-stent technique (two-stent group) or provisional stenting (provisional group). The primary endpoint was the composite of target lesion failure (TLF) at the 1-year follow-up, including cardiac death, target vessel myocardial infarction (TVMI), and clinically driven target lesion revascularization (TLR). The safety endpoint was definite or probable stent thrombosis. At the 1-year follow-up, TLF occurred in 37 (11.4%) and 20 (6.1%) patients in the provisional and two-stent groups, respectively [77.8%: double-kissing crush; hazard ratio (HR) 0.52, 95% confidence interval (CI) 0.30-0.90; P = 0.019], largely driven by increased TVMI (7.1%, HR 0.43, 95% CI 0.20-0.90; P = 0.025) and clinically driven TLR (5.5%, HR 0.43, 95% CI 0.19-1.00; P = 0.049) in the provisional group. At the 1 year after indexed procedures, the incidence of cardiac death was 2.5% in the provisional group, non-significant to 2.1% in the two-stent group (HR 0.86, 95% CI 0.31-2.37; P = 0.772). CONCLUSION: For DEFINITION criteria-defined complex coronary bifurcation lesions, the systematic two-stent approach was associated with a significant improvement in clinical outcomes compared with the provisional stenting approach. Further study is urgently warranted to identify the mechanisms contributing to the increased rate of TVMI after provisional stenting. STUDY REGISTRATION: http://www.clinicaltrials.com; Identifier: NCT02284750.


Coronary Artery Disease , Percutaneous Coronary Intervention , Coronary Angiography , Coronary Artery Disease/surgery , Humans , Stents , Time Factors , Treatment Outcome
8.
BMJ Open ; 8(3): e020019, 2018 03 06.
Article En | MEDLINE | ID: mdl-29511018

INTRODUCTION: Provisional stenting (PS) for simple coronary bifurcation lesions is the mainstay of treatment. A systematic two-stent approach is widely used for complex bifurcation lesions (CBLs). However, a randomised comparison of PS and two-stent techniques for CBLs has never been studied. Accordingly, the present study is designed to elucidate the benefits of two-stent treatment over PS in patients with CBLs. METHODS AND ANALYSIS: This DEFINITION II study is a prospective, multinational, randomised, endpoint-driven trial to compare the benefits of the two-stent technique with PS for CBLs. A total of 660 patients with CBLs will be randomised in a 1:1 fashion to receive either PS or the two-stent technique. The primary endpoint is the rate of 12-month target lesion failure defined as the composite of cardiac death, target vessel myocardial infarction (MI) and clinically driven target lesion revascularisation. The major secondary endpoints include all causes of death, MI, target vessel revascularisation, in-stent restenosis, stroke and each individual component of the primary endpoints. The safety endpoint is the occurrence of definite or probable stent thrombosis. ETHICS AND DISSEMINATION: The study protocol and informed consent have been approved by the Institutional Review Board of Nanjing First Hospital, and accepted by each participating centre. Written informed consent was obtained from all enrolled patients. Findings of the study will be published in a peer-reviewed journal and disseminated at conferences. TRIAL REGISTRATION NUMBER: NCT02284750; Pre-results.


Angioplasty, Balloon, Coronary/methods , Coronary Artery Disease/surgery , Coronary Stenosis/therapy , Coronary Vessels/surgery , Stents , Aged , Coronary Artery Disease/pathology , Coronary Vessels/pathology , Drug-Eluting Stents , Female , Humans , Male , Middle Aged , Myocardial Infarction/etiology , Myocardial Infarction/prevention & control , Percutaneous Coronary Intervention/methods , Prospective Studies , Prosthesis Design , Research Design , Treatment Outcome
10.
J Invasive Cardiol ; 16(6): 343-4, 2004 Jun.
Article En | MEDLINE | ID: mdl-15156011

When dealing with acute coronary syndromes, the interventionists often go straight to balloon and stents, because they work quick and well in the majority of cases. However, it is not to forget that vigorous antithrombotic treatment is frequently highly beneficial in these settings. We report here on two clinical cases of coronary thrombosis in which we could appreciate on the angiograms the effect of GP IIb/IIIa inhibitor eptifibatide alone or in conjunction with alteplase.


Coronary Angiography , Coronary Thrombosis/drug therapy , Peptides/therapeutic use , Platelet Aggregation Inhibitors/therapeutic use , Aged , Coronary Thrombosis/diagnostic imaging , Eptifibatide , Female , Humans , Male , Middle Aged
11.
Eur J Cardiothorac Surg ; 24(1): 81-5; discussion 85, 2003 Jul.
Article En | MEDLINE | ID: mdl-12853049

OBJECTIVE: It is not well established whether the blood flow of arterial composite Y-grafts can efficiently respond to the flow demand of the coronary system early postoperatively. The aim of this study was to evaluate if soon after the operation, arterial composite Y-grafts can increase blood flow in response to an increase in myocardial oxygen consumption (MVO2). METHODS: Twenty-seven patients who received complete arterial myocardial revascularization using the left internal thoracic artery (LITA) and the radial artery (RA) as composite Y-graft gave their consent to a pre-discharge coronary angiography and intravascular flow velocity measurements using a Doppler guide wire. Flow measurements were performed in the LITA main stem, the distal LITA and the RA, both at rest and during atrial pacing at the 85% of the patient age-predicted maximum. The heart rate-systolic blood pressure product was considered as an indirect index of MVO2. Hyperemic flow was determined after injection of adenosine. The flow reserve (FR) was defined as the ratio of blood flow during maximal hyperemia (Qmax) to baseline flow (Qbasal). RESULTS: Atrial pacing increased MVO2 significantly (P<0.000). None of the patients developed ischemic S-T segment modifications or complained of chest pain. Q(basal) increased significantly in the LITA main stem (P=0.001), distal LITA (P=0.041) and RA (P=0.004) while Qmax did not change significantly. As a consequence, the FR decreased in the LITA main stem (P=0.002), distal LITA (P<0.000) and RA (P<0.000) but was not completely exhausted. CONCLUSIONS: Soon after the operation, arterial composite Y-grafts can significantly increase blood flow in response to conditions of increased MVO2, keeping normal the myocardial O2 supply-to-demand ratio.


Coronary Disease/physiopathology , Coronary Disease/surgery , Heart Rate/physiology , Myocardial Revascularization , Aged , Blood Flow Velocity , Cardiac Catheterization , Cardiac Pacing, Artificial , Coronary Circulation , Coronary Disease/metabolism , Humans , Laser-Doppler Flowmetry , Male , Mammary Arteries/surgery , Middle Aged , Myocardium/metabolism , Oxygen Consumption , Patient Selection , Radial Artery/surgery , Ultrasonography, Interventional
...