Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Respir Res ; 25(1): 75, 2024 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-38317149

RESUMEN

BACKGROUND: Electronic cigarettes (EC) have gained popularity, especially among young people, with the introduction of fourth-generation devices based on e-liquids containing nicotine salts that promise a smoother vaping experience than freebase nicotine. However, the toxicological effects of nicotine salts are still largely unknown, and the chemical diversity of e-liquids limits the comparison between different studies to determine the contribution of each compound to the cytotoxicity of EC aerosols. Therefore, the aim of this study was to evaluate the toxicological profile of controlled composition e-liquid aerosols to accurately determine the effects of each ingredient based on exposure at the air-liquid interface. METHODS: Human lung epithelial cells (A549) were exposed to undiluted aerosols of controlled composition e-liquids containing various ratios of propylene glycol (PG)/vegetable glycerin (VG) solvents, freebase nicotine, organic acids, nicotine salts, and flavoured commercial e-liquids. Exposure of 20 puffs was performed at the air-liquid interface following a standard vaping regimen. Toxicological outcomes, including cytotoxicity, inflammation, and oxidative stress, were assessed 24 h after exposure. RESULTS: PG/VG aerosols elicited a strong cytotoxic response characterised by a 50% decrease in cell viability and a 200% increase in lactate dehydrogenase (LDH) production, but had no effects on inflammation and oxidative stress. These effects occurred only at a ratio of 70/30 PG/VG, suggesting that PG is the major contributor to aerosol cytotoxicity. Both freebase nicotine and organic acids had no greater effect on cell viability and LDH release than at a 70/30 PG/VG ratio, but significantly increased inflammation and oxidative stress. Interestingly, the protonated form of nicotine in salt showed a stronger proinflammatory effect than the freebase nicotine form, while benzoic acid-based nicotine salts also induced significant oxidative stress. Flavoured commercial e-liquids was found to be cytotoxic at a threshold dose of ≈ 330 µg/cm². CONCLUSION: Our results showed that aerosols of e-liquids consisting only of PG/VG solvents can cause severe cytotoxicity depending on the concentration of PG, while nicotine salts elicit a stronger pro-inflammatory response than freebase nicotine. Overall, aerosols from fourth-generation devices can cause different toxicological effects, the nature of which depends on the chemical composition of the e-liquid.


Asunto(s)
Sistemas Electrónicos de Liberación de Nicotina , Vapeo , Humanos , Adolescente , Nicotina/toxicidad , Vapeo/efectos adversos , Sales (Química) , Solventes , Propilenglicol/toxicidad , Propilenglicol/química , Glicerol/química , Glicerol/farmacología , Aerosoles , Aromatizantes , Inflamación
2.
Nanoscale Adv ; 6(2): 458-466, 2024 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-38235099

RESUMEN

To investigate potential correlations between human exposure to inhaled particles and pathological effects, the biological monitoring of nanoparticles in broncho-alveolar lavages (BAL) from patients has been proposed. To better understand the underlying mechanisms of toxicity, we propose to couple this biomonitoring of nanoparticles to their in vitro toxicity assessment. However, BAL obtained from regular clinical practice are conditioned with sodium hypochlorite solution (in a 50% v/v ratio), which is toxic to cells. The aim of this study was to develop a protocol to neutralize sodium hypochlorite, allowing to properly investigate the toxicity of the nanoparticles BAL contain. We first tried to neutralize chemically the sodium hypochlorite using H2O2, ascorbic acid or sodium ascorbate but this approach was unsuccessful. In addition, standard toxicology assays (MTT, LDH) could not be used because of interference with neutralizing solutions. We thus changed strategy and used ultracentrifugation to isolate nanoparticles from the sodium hypochlorite solution, with satisfactory extraction yields (88 to 100%). We then incubated the extracted nanoparticles with macrophages from the RAW264.7 cell line and assessed the cell viability and pro-inflammatory response. This study can be used as a proof-of-concept for further study of the biological impact of nanoparticles. This approach paves the way for studies aiming at a better understanding of the aetiology of some idiopathic diseases and underlying mechanisms.

3.
Pharmaceuticals (Basel) ; 16(12)2023 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-38139856

RESUMEN

This work aims to investigate bronchodilator delivery with the use of different vaping drug delivery systems (VDDS) by determining the dose equivalence delivered in relation to different references: a clinical jet nebulizer, a pMDI (pressurized metered dose inhaler) and a DPI (dry powder inhaler). Three different bronchodilators were used (terbutaline, salbutamol hemisulfate, ipratropium bromide). The e-liquids contained the active pharmaceutical ingredient (API) in powder form. Two different VDDS were tested (JUUL and a GS AIR 2 atomizer paired with a variable lithium-ion battery (i-stick TC 40 W), 1.5 ohm resistance, and 15 W power). Samples were collected using a glass twin impinger (GTI). High-performance liquid chromatography (HPLC) was used to quantify the drugs. A next-generation impactor (NGI) was used to measure the particle size distribution. Terbutaline emerged as the optimal API for bronchodilator delivery in both VDDS devices. It achieved the delivery of a respirable dose of 20.05 ± 4.2 µg/puff for GS AIR 2 and 2.98 ± 0.52 µg/puff for JUUL. With these delivered doses, it is possible to achieve a dose equivalence similar to that of a jet nebulizer and DPI, all while maintaining a reasonable duration, particularly with the GS AIR 2. This study is the first to provide evidence that vaping bronchodilators work only with appropriate formulation, vaping technology, and specific drugs, depending on their thermal degradation properties.

4.
Sci Rep ; 13(1): 11056, 2023 07 08.
Artículo en Inglés | MEDLINE | ID: mdl-37422519

RESUMEN

Successful aerosol therapy in mechanically ventilated patients depends on multiple factors. Among these, position of nebulizer in ventilator circuit and humidification of inhaled gases can strongly influence the amount of drug deposited in airways. Indeed, the main objective was to preclinically evaluate impact of gas humidification and nebulizer position during invasive mechanical ventilation on whole lung and regional aerosol deposition and losses. Ex vivo porcine respiratory tracts were ventilated in controlled volumetric mode. Two conditions of relative humidity and temperature of inhaled gases were investigated. For each condition, four different positions of vibrating mesh nebulizer were studied: (i) next to the ventilator, (ii) right before humidifier, (iii) 15 cm to the Y-piece adapter and (iv) right after the Y-piece. Aerosol size distribution were calculated using cascade impactor. Nebulized dose, lung regional deposition and losses were assessed by scintigraphy using 99mtechnetium-labeled diethylene-triamine-penta-acetic acid. Mean nebulized dose was 95% ± 6%. For dry conditions, the mean respiratory tract deposited fractions reached 18% (± 4%) next to ventilator and 53% (± 4%) for proximal position. For humidified conditions, it reached 25% (± 3%) prior humidifier, 57% (± 8%) before Y-piece and 43% (± 11%) after this latter. Optimal nebulizer position is proximal before the Y-piece adapter showing a more than two-fold higher lung dose than positions next to the ventilator. Dry conditions are more likely to cause peripheral deposition of aerosols in the lungs. But gas humidification appears hard to interrupt efficiently and safely in clinical use. Considering the impact of optimized positioning, this study argues to maintain humidification.


Asunto(s)
Ventilación no Invasiva , Animales , Porcinos , Broncodilatadores , Nebulizadores y Vaporizadores , Aerosoles , Pulmón/diagnóstico por imagen , Administración por Inhalación , Respiración Artificial , Gases , Diseño de Equipo , Albuterol
5.
Prev Med Rep ; 35: 102278, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37389205

RESUMEN

Background: We assessed/compared the evolution of tobacco and e-cigarette experimentation and use among French adolescents of the Loire department aged 15-16 years. Methods: A descriptive, cross-sectional/observational study conducted in 2018-2020 among 7,950 Year 11 pupils attending 27 public secondary schools of the Loire department, France. Results: From 2018 to 2020, 66.18% of adolescents were "non-vapers and non-smokers", 19.76% were "vapers and smokers", 7.90% were "non-vapers and smokers" and 6.15% were "vapers and non-smokers". E-cigarette experimentation was more prevalent than tobacco experimentation (44.92% vs 41.67%), and daily vaping was less prevalent than daily smoking (5.40% vs 10.24%). More boys than girls were daily vapers or daily smokers. A decrease was observed in tobacco experimentation (from 41.22% in 2018 to 39.73% in 2020) and e-cigarette experimentation (from 50.28% in 2018 to 41.25% in 2020). Current vaping remained stable, with an increase in daily vaping. French adolescent vapers frequently use e-liquids with little or no nicotine or with fruit or sweet flavours. Conclusions: Adolescents used e-cigarettes mainly for experimental and/or recreational purposes, with no intention of progression to daily smoking. Although the design of this study is not longitudinal and caution must be exercised, from our cross-sectional observational study data, it appears that the proportion of "non-vapers and non-smokers" tended to increase. "Smokers" tended to progress to the dual use of vaping and smoked tobacco, with the likely intention to reduce or quit smoking.

6.
Pharmaceuticals (Basel) ; 16(2)2023 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-37259287

RESUMEN

This study aims to evaluate the impact of the nasal delivery technique and nebulizing technologies (using different frequencies of oscillating airflow) for acoustic aerosol targeting of maxillary sinuses. Sodium fluoride (chemical used as a marker), tobramycin (drug used as a marker) and 99mTc-DTPA (radiolabel aerosol) were used to assess the intrasinus aerosol deposition on a nasal cast. Two commercial medical devices (PARI SINUS nebulizer and NL11SN ATOMISOR nebulizer) and various nasal delivery techniques (one or two nostrils connected to the aerosol inlet, the patient with the soft palate closed or open during the acoustic administration of the drug, the presence or not of flow resistance in the nostril opposite to the one allowing the aerosol to be administered) were evaluated. The closed soft palate condition showed a significant increase in drug deposition even though no significant difference in the rest of the nasal fossae was noticed. Our results clearly demonstrated a higher intrasinus aerosol deposition (by a factor 2-3; respectively 0.03 ± 0.007% vs. 0.003 ± 0.0002% in the right maxillary sinus and 0.027 ± 0.006% vs. 0.013 ± 0.004% in the left maxillary sinus) using the acoustic airflow generated by the PARI SINUS compared to the NL11SN ATOMISOR. The results clearly demonstrated that the optimal conditions for aerosol deposition in the maxillary sinuses were obtained with a closed soft palate. Thus, the choice of the nebulizing technology (and mainly the frequency of the pulsating aerosol generated) and also the recommendation of the best nasal delivery technique are key factors to improve intrasinus aerosol deposition.

7.
Tob Prev Cessat ; 9: 21, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37363269

RESUMEN

INTRODUCTION: We describe the vaping and smoking habits of French adolescents aged 15-16 years in the Loire department with a view to assess the impact of e-cigarette experimentation and use on their smoking behavior. METHODS: This quantitative, cross-sectional, single-center and observational study conducted from January to July 2019 targeted 6622 students aged 15-16 years attending public high school in the Loire department, France. RESULTS: A total of 4937 (74.6%) adolescents were included. Of these, 73.2% were non-vapers and 72.2% non-smokers; 66.0% of adolescents were non-vapers and non-smokers. Slightly less than half of adolescents had experimented with e-cigarettes (44.6%), more than half of whom (26.8%) continued to use vaping products, with 6.02% vaping daily. Likewise, a little less than half of adolescents had experimented with smoked tobacco (42.4%), more than half of whom (27.8%) continued to use smoking products, with 10.3% smoking daily. Vapers and smokers (20.6%) tended to begin with the use of smoked tobacco and to progress to the dual use of vaping and smoked tobacco products. Vaping had a positive effect, as 71.8% of vapers who smoked tobacco before initiating vaping stopped or reduced smoking following their progression to this double use. More than half of tobacco users are daily users while this daily use affects only 1/3 boys and 1/6 girls for vape. Finally, nearly 80.7% of adolescents who had never smoked before vaping did not smoke at the time of the study. CONCLUSIONS: Our data suggest that vaping has a rather marginal impact on smoking initiation among French adolescents aged 15-16 years in the Loire department. They therefore neither confirm nor completely disprove the gateway effect theory, relating to use of tobacco subsequent to vaping.

8.
Sci Rep ; 13(1): 7115, 2023 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-37130944

RESUMEN

Face masks are often recommended in community settings to prevent the airborne transmission of respiratory viruses or bacteria. Our first objective was to develop an experimental bench to assess the viral filtration efficiency (VFE) of a mask with a methodology similar to the normative measurement of bacterial filtration efficiency (BFE) used to determine the filtration performance of medical masks. Then, using three categories of masks of increasing filtration quality (two types of community masks and one type of medical mask), filtration performances measured ranged from 61.4 to 98.8% of BFE and from 65.5 to 99.2% of VFE. A strong correlation (r = 0.983) between bacterial and viral filtration efficiency was observed for all types of masks and for the same droplets size in the 2-3 µm range. This result confirms the relevance of the EN14189:2019 standard using bacterial bioaerosols to evaluate mask filtration, to also extrapolate mask performances whatever their filtration quality against viral bioaerosols. Indeed, it appears that the filtration efficiency of masks (for micrometer droplet sizes and low bioaerosol exposure times) depends mainly on the size of the airborne droplet, rather than on the size of the infectious agent contained in that droplet.


Asunto(s)
Filtración , Máscaras , Bacterias
9.
Int J Pharm ; 633: 122652, 2023 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-36709833

RESUMEN

PURPOSE: This study aims to evaluate the performance of low-cost homemade spacers compared with manufactured valved holding chambers (VHCs) for fluticasone propionate delivery via a pMDI (pressurized Metered Dose Inhaler). METHODS: The Total Emitted Dose (TED) and particle size distribution were measured for pMDI alone or connected to the different spacers, according to CAN/CSA-Z264.1-02 standard. Two types of low-cost alternative and manufactured spacers were investigated: 500 mL plastic bottle and 553 mL aluminium can; non-antistatic plastic VHCs and aluminium antistatic VHCs. RESULTS: The TED of homemade plastic bottle vs plastic VHC were similar in the 20-23% range. In contrast, the TED of homemade aluminium can was higher compared to aluminium VHC (83% vs 68%). The Fine Particle Fraction (FPF) was similar for the two plastic-based spacers (in the 12.68-17.60% range), although it was greater for the aluminium can compared to aluminium VHC (51% vs 42%). However, all spacers have limited large particles fraction, mainly deposited in the oropharyngeal tract, potentially decreasing side effects. CONCLUSION: We demonstrated that low-tech solutions as homemade spacers have at least similar performances to VHC medical devices composed of same material (aluminium or plastic). Thus, low-cost homemade spacers represent alternatives in case of emergency and without VHCs nearby.


Asunto(s)
Albuterol , Aluminio , Sistemas de Liberación de Medicamentos , Diseño de Equipo , Aerosoles , Inhaladores de Dosis Medida , Administración por Inhalación , Plásticos , Broncodilatadores
10.
Toxics ; 10(12)2022 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-36548617

RESUMEN

The potential cardiovascular effects of e-cigarettes remain largely unidentified and poorly understood. E-liquids contain numerous chemical compounds and can induce exposure to potentially toxic ingredients (e.g., nicotine, flavorings, etc.). Moreover, the heating process can also lead to the formation of new thermal decomposition compounds that may be also hazardous. Clinical as well as in vitro and in vivo studies on e-cigarette toxicity have reported potential cardiovascular damages; however, results remain conflicting. The aim of this study was to assess, in vitro, the toxicity of e-liquids and e-cigarette aerosols on human aortic smooth muscle cells. To that purpose, cells were exposed either to e-liquids or to aerosol condensates obtained using an e-cigarette device at different power levels (8 W or 25 W) to assess the impact of the presence of: (i) nicotine, (ii) cinnamon flavor, and (iii) thermal degradation products. We observed that while no cytotoxicity and no ROS production was induced, a pro-inflammatory response was reported. In particular, the production of IL-8 was significantly enhanced at a high power level of the e-cigarette device and in the presence of the cinnamon flavor (confirming the suspected toxic effect of this additive). Further investigations are required, but this study contributes to shedding light on the biological effects of vaping on the cardiovascular system.

11.
Sante Publique ; 34(4): 471-480, 2022.
Artículo en Francés | MEDLINE | ID: mdl-36577675

RESUMEN

Introduction : Longitudinal studies make it possible to study the evolution of a class of individuals over time. However, they are rarely used in France to observe the same population of young adolescents according to their grade level over the course of several years.Purpose of research : Based on the longitudinal monitoring of repeated annual cross-sectional studies on young adolescents (from 15 to 18 years old) conducted at the Honoré d’Urfé public high school (Saint-Étienne, Loire, France) involving 336 10th grade pupils in 2018, 360 11th grade pupils in 2019 and 273 12th grade pupils in 2020, we observed and studied students’ smoking and vaping behavior over a period of three years.Results : Between the ages of 15 and 18 years, the prevalence of tobacco experimentation increased almost linearly (39.10%, 47.50%, and 53.11%), while the prevalence of ‘non-smoking’ decreased by 4.5%. In addition, the prevalence of e-cigarette experimentation was stable (46.38%, 49.44%, 47.62%), whereas the prevalence of daily vaping increased by 5.0%.Conclusions : The prevalence of tobacco experimentation tends to increase with age and to catch up with that of e-cigarette experimentation, which remains stable at this stage of adolescence. Introductions to these two products seem to be rather recreational, playful, and experimental in nature, and do not have a significant connection with the development of their daily use or propensity to addiction.


Asunto(s)
Conducta del Adolescente , Sistemas Electrónicos de Liberación de Nicotina , Vapeo , Humanos , Adolescente , Estudios Transversales , Estudios Longitudinales , Prevalencia
12.
J Breath Res ; 17(1)2022 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-36541529

RESUMEN

In the field of biomonitoring, exhaled breath condensate (EBC) is described as a potentially useful matrix for assessing inhalation exposure biomarkers in a non-invasive way. However, it is still unclear to what extent EBC is representative of the deep lung. To address this knowledge gap, EBC, bronchial washes (BWs), and bronchoalveolar lavages (BALs) were collected from 82 patients suffering from interstitial lung diseases (ILDs). The particulate contents and elemental composition of EBC, BW, and BAL were then compared in the same patients. The size distribution of particles in EBC was assessed with dynamic light scattering while inductively coupled plasma mass spectrometry was used to quantify its elemental composition. In addition, transmission electron microscopy coupled with energy dispersive x-ray spectrometry were used to further characterize samples of interest. EBC was found to be representative of both the sub-micron and nano-sized particle fractions of BAL and BW, with lower overall levels of elements in EBC than in BW and BAL. Silicon (Si) was the main component for all respiratory matrices with median levels of 2525µg l-1, 5643µg l-1and 5169µg l-1in the nano/ion fractions of EBC, BAL and BW, respectively. Moreover, Si levels in EBC from patients in this study were elevated compared to the levels reported in the literature for healthy subjects. Interestingly, Si levels in the EBC of ILD patients were inversely related to those in BAL and BW. In conclusion, the particulate content of EBC is associated with the lung particle burden and potentially correlates with pathologies, rendering it a relevant biomonitoring technique for the occupational and clinical fields.


Asunto(s)
Enfermedades Pulmonares Intersticiales , Irrigación Terapéutica , Humanos , Pruebas Respiratorias/métodos , Pulmón/química , Lavado Broncoalveolar , Biomarcadores/análisis
13.
Int J Pharm ; 628: 122350, 2022 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-36374741

RESUMEN

PURPOSE: Several technical features influencing bronchodilator delivery were evaluated using different vaping drug delivery systems (VDDS). METHODS: Terbutaline in powder form, combined with 1, 3- propanediol used as e-liquid was tested at different concentrations (1 and 2.5 mg/mL), power levels (15 W and 30 W), and set applied resistances (0.15 to 1.5 O) to compare the efficiency of three VDDS (GS AIR2, GS TANK, CUBIS). Samples were collected with a Glass Twin Impinger (GTI). A High Performance Liquid Chromatography (HPLC) was used for drug quantification. The Next Generation Impactor (NGI) measured particle size distribution. Results were also considered with a clinical jet nebulizer (Cirrus TM 2, 2 mL of terbutaline at 2.5 mg/mL). RESULTS: GS AIR2 with resistance = 1.5 O; power = 15 W, and [Terbutaline] = 2.5 mg/mL represents the optimal VDDS conditions to deliver a respirable dose of 20.05 ± 4.2 µg/puff with a mass median aerodynamic diameter (MMAD) of 1.41 ± 0.03 µm. Thus, 52 puffs were required (lasting approximately 15 min of vaping) to reach similar respirable dose and MMAD compared to nebulization. CONCLUSION: We proved that several crucial VDDS technical parameters govern the performance of respiratory bronchodilator delivery including the resistance, power level and atomizer design.


Asunto(s)
Broncodilatadores , Vapeo , Broncodilatadores/química , Terbutalina/química , Aerosoles/química , Tamaño de la Partícula , Nebulizadores y Vaporizadores , Sistemas de Liberación de Medicamentos
14.
Sci Rep ; 12(1): 15853, 2022 09 23.
Artículo en Inglés | MEDLINE | ID: mdl-36151269

RESUMEN

Can medical face masks be replaced by reusable community face masks with similar performance? The influence of the number of wash cycles, the wash temperature and the use of detergent was evaluated on the performance of one medical face masks (MFM) and ten community face masks (CFM). The performance of the new and washed masks was characterized from the bacterial filtration efficiency (BFE) and the differential pressure (DP). The tests on the new masks showed that the MFM had always better BFE than CFMs. Although two of the CFMs showed a BFE value exceeding 95%, only one can be classified as type I MFM based on both BFE and DP requirements. The influence of the washing parameters was investigated on the MFM and these two CMFs with excellent BFE properties. The parameters had no effect on the BFE of CFMs whilst the MFM exhibited a loss in efficiency when washed with detergent. The DP of masks were not impacted by the washing. The results clearly show that even though a compromise has to be made between the BFE and breathability, it seems possible to manufacture CFMs with performances similar to a type I MFM, without achieving type II requirements.


Asunto(s)
COVID-19 , Máscaras , Detergentes , Filtración , Humanos
15.
Chem Res Toxicol ; 35(7): 1234-1243, 2022 07 18.
Artículo en Inglés | MEDLINE | ID: mdl-35686948

RESUMEN

Given that nicotine salts are a growing market, methods are needed to characterize nicotine forms in e-cigarette vaping products. By lowering the free-base nicotine fraction (αfb) in favor of protonated forms, the addition of organic acids to the e-liquid mix greatly modulates nicotine pharmacokinetics and improves vapers' craving. This research investigated (1) the performance of pH measurement, liquid-liquid extraction (LLE), and acid/nicotine molar ratio calculation methods for αfb estimation in 6 nicotine benzoate and nicotine salicylate e-liquids and (2) nicotine protonation in the aerosol post vaporization. Aerosols were generated with a JUUL device and another mod-pod on a vaping machine to assess device effects. E-liquid and aerosol samples were then analyzed after further analytical optimization of previous methods and careful consideration of biases. Globally, performances were comparable between methods. αfb accounted for less than 5% of nicotine content regardless of experimental conditions. αfb were consistent between e-liquids and aerosols irrespective of e-cigarette devices. Hence, e-liquids are adequate surrogates for aerosols, facilitating the establishment of regulations. pH measurement is one of the most used methods and enables the establishment of relative scales for e-liquid classification but lacks automation possibility. Until now, the extent of sample dilution remained arbitrary. The dilution factor was fixed at 10, as usually achieved, since no effect of dilution was noted. pH values ranged from 5.3 to 6.3 in accordance with the literature. By contrast, LLE relies on the specificity of organic solvent for free-base nicotine extraction, causing discrepancies in previous studies. Here, the results were similar to αfb values from pH determination. Yet, LLE presented the highest variability and was the most time-consuming protocol. Finally, αfb calculation from molar ratio was the most robust and versatile method. Estimations can be made in silico from reported composition data and/or after liquid chromatography routine analysis.


Asunto(s)
Sistemas Electrónicos de Liberación de Nicotina , Vapeo , Aerosoles/química , Nicotina/análisis , Solventes
16.
Artículo en Inglés | MEDLINE | ID: mdl-35328980

RESUMEN

The increase in legionellosis incidence in the general population in recent years calls for a better characterization of the sources of infection, such as showering. Water-efficient shower systems that use water-atomizing technology have been shown to emit slightly more inhalable particles in the range of bacterial sizes than the traditional systems; however, the actual rate of bacterial emission remains poorly documented. The aim of this study was to assess the aerosolisation rate of the opportunistic water pathogen Legionella pneumophila during showering with one shower system representative of each technology. To achieve this objective, we performed controlled experiments inside a glove box and determined the emitted dose and viability of airborne Legionella. The bioaerosols were sampled with a Coriolis® Delta air sampler and the total number of viable (cultivable and noncultivable) Legionella was determined by flow cytometry and culture. We found that the rate of viable and cultivable Legionella aerosolized from the water jet was similar between the two showerheads: the viable fraction represents 0.02% of the overall bacteria present in water, while the cultivable fraction corresponds to only 0.0005%. The two showerhead models emitted a similar ratio of airborne Legionella viable and cultivable per volume of water used. Therefore, the risk of exposure to Legionella is not expected to increase significantly with the new generation of water-efficient showerheads.


Asunto(s)
Legionella pneumophila , Legionella , Legionelosis , Humanos , Agua , Microbiología del Agua , Abastecimiento de Agua
17.
Sci Rep ; 12(1): 1188, 2022 01 24.
Artículo en Inglés | MEDLINE | ID: mdl-35075199

RESUMEN

As a result of the current COVID-19 pandemic, the use of facemasks has become commonplace. The performance of medical facemasks is assessed using Bacterial Filtration Efficiency (BFE) tests. However, as BFE tests, require specific expertise and equipment and are time-consuming, the performance of non-medical facemasks is assessed with non-biological Particle Filtration Efficiency (PFE) tests which are comparatively easier to implement. It is necessary to better understand the possible correlations between BFE and PFE to be able to compare the performances of the different types of masks (medical vs. non-medical). In this study BFE results obtained in accordance with the standard EN 14683 are compared to the results of PFE from a reference test protocol defined by AFNOR SPEC S76-001 with the aim to determine if BFE could be predicted from PFE. Our results showed a correlation between PFE and BFE. It was also observed that PFE values were higher than BFE and this was attributed to the difference in particle size distribution considered for efficiency calculation. In order to properly compare these test protocols for a better deduction, it would be interesting to compare the filtration efficiency for a similar granulometric range.


Asunto(s)
COVID-19/prevención & control , Máscaras , Pandemias/prevención & control , SARS-CoV-2 , Filtración , Humanos , Tamaño de la Partícula
18.
Chemosphere ; 288(Pt 1): 132364, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34600007

RESUMEN

The need for personal protective equipment increased exponentially in response to the Covid-19 pandemic. To cope with the mask shortage during springtime 2020, a French consortium was created to find ways to reuse medical and respiratory masks in healthcare departments. The consortium addressed the complex context of the balance between cleaning medical masks in a way that maintains their safety and functionality for reuse, with the environmental advantage to manage medical disposable waste despite the current mask designation as single-use by the regulatory frameworks. We report a Workflow that provides a quantitative basis to determine the safety and efficacy of a medical mask that is decontaminated for reuse. The type IIR polypropylene medical masks can be washed up to 10 times, washed 5 times and autoclaved 5 times, or washed then sterilized with radiations or ethylene oxide, without any degradation of their filtration or breathability properties. There is loss of the anti-projection properties. The Workflow rendered the medical masks to comply to the AFNOR S76-001 standard as "type 1 non-sanitory usage masks". This qualification gives a legal status to the Workflow-treated masks and allows recommendation for the reuse of washed medical masks by the general population, with the significant public health advantage of providing better protection than cloth-tissue masks. Additionally, such a legal status provides a basis to perform a clinical trial to test the masks in real conditions, with full compliance with EN 14683 norm, for collective reuse. The rational reuse of medical mask and their end-of-life management is critical, particularly in pandemic periods when decisive turns can be taken. The reuse of masks in the general population, in industries, or in hospitals (but not for surgery) has significant advantages for the management of waste without degrading the safety of individuals wearing reused masks.


Asunto(s)
COVID-19 , Pandemias , Humanos , Máscaras , Equipo de Protección Personal , SARS-CoV-2
19.
Sci Rep ; 11(1): 5887, 2021 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-33723303

RESUMEN

Based on the current knowledge of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) transmission, wearing a mask has been recommended during the COVID-19 pandemic. Bacterial filtration efficiency (BFE) measurements enable designing and regulating medical masks to prevent bioaerosol dissemination; however, despite the simplicity of these measurements, several scientific questions remain unanswered regarding BFE tests. Here, we investigated (1) the impact of substituting 100-mm Petri dishes with 90-mm disposable Petri dishes, (2) the impact of colony-counting methods on the bioaerosol aerodynamic size, and (3) the impact of colony-counting methods on the total viable particle counts. We demonstrated that disposable 90-mm Petri dishes can be used to replace the 100-mm dishes. We also showed that an automatic high-resolution colony counter can be used to directly count viable particles on collection substrates and to measure the bioaerosol size parameters. Our results enable possible modernization of the outdated testing methods recommended in the US and European standards for BFE measurements. Specifically, use of a modernized colony counter should be clearly regulated and permitted to avoid the counting of positive holes. The median aerodynamic diameter appears to be the most relevant parameter for characterizing bioaerosol size.


Asunto(s)
Bacterias , Filtración/normas , Máscaras/normas , Carga Bacteriana , Microbiología Ambiental , Filtración/métodos , Humanos , Máscaras/microbiología , Tamaño de la Partícula , Porosidad
20.
Sci Rep ; 10(1): 21707, 2020 12 10.
Artículo en Inglés | MEDLINE | ID: mdl-33303941

RESUMEN

The reliable characterization of particle size distribution and nicotine delivery emitted by electronic cigarettes (ECs) is a critical issue in their design. Indeed, a better understanding of how nicotine is delivered as an aerosol with an appropriate aerodynamic size is a necessary step toward obtaining a well-designed nicotine transfer from the respiratory tract to the bloodstream to better satisfy craving and improve smoking cessation rates. To study these two factors, recent models of EC devices and a dedicated vaping machine were used to generate aerosols under various experimental conditions, including varying the EC power level using two different types of atomizers. The aerodynamic particle sizing of the resulting aerosol was performed using a cascade impactor. The nicotine concentration in the refill liquid and the aerosol droplet was quantified by liquid chromatography coupled with a photodiode array. The vaporization process and the physical and chemical properties of the EC aerosol were very similar at 15 watts (W) and 25 W using the low-power atomizer but quite distinct at 50 W using the high-power atomizer, as follows: (1) the mass median aerodynamic diameters ranged from 1.06 to 1.19 µm (µm) for low power and from 2.33 to 2.46 µm for high power; (2) the nicotine concentrations of aerosol droplets were approximately 11 mg per milliliter (mg/mL) for low power and 17 mg/mL for high power; and (3) the aerosol droplet particle phase of the total nicotine mass emitted by EC was 60% for low power and 95% for high power. The results indicate that varying the correlated factors (1) the power level and (2) the design of atomizer (including the type of coil and the value of resistance used) affects the particle-size distribution and the airborne nicotine portioning between the particle phase and the gas phase in equilibrium with the airborne droplets.


Asunto(s)
Aerosoles/química , Sistemas Electrónicos de Liberación de Nicotina , Nicotina/análisis , Diseño de Equipo , Gases , Tamaño de la Partícula , Volatilización
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...