Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Asunto principal
Intervalo de año de publicación
1.
Crit Care Med ; 51(12): e253-e263, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-37678209

RESUMEN

OBJECTIVES: To identify cytokine signature clusters in patients with septic shock. DESIGN: Prospective observational cohort study. SETTING: Single academic center in the United States. PATIENTS: Adult (≥ 18 yr old) patients admitted to the medical ICU with septic shock requiring vasoactive medication support. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: One hundred fourteen patients with septic shock completed cytokine measurement at time of enrollment (t 1 ) and 24 hours later (t 2 ). Unsupervised random forest analysis of the change in cytokines over time, defined as delta (t 2 -t 1 ), identified three clusters with distinct cytokine profiles. Patients in cluster 1 had the lowest initial levels of circulating cytokines that decreased over time. Patients in cluster 2 and cluster 3 had higher initial levels that decreased over time in cluster 2 and increased in cluster 3. Patients in clusters 2 and 3 had higher mortality compared with cluster 1 (clusters 1-3: 11% vs 31%; odds ratio [OR], 3.56 [1.10-14.23] vs 54% OR, 9.23 [2.89-37.22]). Cluster 3 was independently associated with in-hospital mortality (hazard ratio, 5.24; p = 0.005) in multivariable analysis. There were no significant differences in initial clinical severity scoring or steroid use between the clusters. Analysis of either t 1 or t 2 cytokine measurements alone or in combination did not reveal clusters with clear clinical significance. CONCLUSIONS: Longitudinal measurement of cytokine profiles at initiation of vasoactive medications and 24 hours later revealed three distinct cytokine signature clusters that correlated with clinical outcomes.


Asunto(s)
Choque Séptico , Adulto , Humanos , Estados Unidos/epidemiología , Estudios Prospectivos , Citocinas
2.
Cureus ; 15(5): e39122, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37332456

RESUMEN

Despite the benefits of the intra-aortic balloon pump (IABP) being a subject of debate, it remains a widely available and easy-to-use mechanical circulatory support device. Nonetheless, its use is not exempt from complications. Aortic dissection from IABP is an infrequent but deathly complication. We describe a case in which early recognition of the condition led to control through an endovascular approach. A 57-year-old male was admitted for acute decompensated heart failure requiring intravenous inotropic agents. While undergoing assessment for a heart transplant, he developed cardiogenic shock requiring initiation of mechanical circulatory support with an IABP. A few hours after device implantation, the patient developed acute tearing chest pain and was found to have an acute dissection in the descending thoracic aorta. Prompt liaison with the endovascular team led to a thoracic endovascular aortic repair to control the extent of the lesion.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...