Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Nefrologia (Engl Ed) ; 43(4): 442-451, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37661514

RESUMEN

INTRODUCTION: SARS CoV2 infection has had a major impact on renal transplant patients with a high mortality in the first months of the pandemic. Intentional reduction of immunosuppressive therapy has been postulated as one of the cornerstone in the management of the infection in the absence of targeted antiviral treatment. This has been modified according to the patient`s clinical situation and its effect on renal function or anti-HLA antibodies in the medium term has not been evaluated. OBJECTIVES: Evaluate the management of immunosuppressive therapy made during SARS-CoV2 infection, as well as renal function and anti-HLA antibodies in kidney transplant patients 6 months after COVID19 diagnosis. MATERIAL AND METHODS: Retrospective, national multicentre, retrospective study (30 centres) of kidney transplant recipients with COVID19 from 01/02/20 to 31/12/20. Clinical variables were collected from medical records and included in an anonymised database. SPSS statistical software was used for data analysis. RESULTS: renal transplant recipients with COVID19 were included (62.6% male), with a mean age of 57.5 years. The predominant immunosuppressive treatment prior to COVID19 was triple therapy with prednisone, tacrolimus and mycophenolic acid (54.6%) followed by m-TOR inhibitor regimens (18.6%). After diagnosis of infection, mycophenolic acid was discontinued in 73.8% of patients, m-TOR inhibitor in 41.4%, tacrolimus in 10.5% and cyclosporin A in 10%. In turn, 26.9% received dexamethasone and 50.9% were started on or had their baseline prednisone dose increased. Mean creatinine before diagnosis of COVID19, at diagnosis and at 6 months was: 1.7 ±â€¯0.8, 2.1 ±â€¯1.2 and 1.8 ±â€¯1 mg/dl respectively (p < 0.001). 56.9% of the patients (N = 350) were monitored for anti-HLA antibodies. 94% (N = 329) had no anti-HLA changes, while 6% (N = 21) had positive anti-HLA antibodies. Among the patients with donor-specific antibodies post-COVID19 (N = 9), 7 patients (3.1%) had one immunosuppressant discontinued (5 patients had mycophenolic acid and 2 had tacrolimus), 1 patient had both immunosuppressants discontinued (3.4%) and 1 patient had no change in immunosuppression (1.1%), these differences were not significant. CONCLUSIONS: The management of immunosuppressive therapy after diagnosis of COVID19 was primarily based on discontinuation of mycophenolic acid with very discrete reductions or discontinuations of calcineurin inhibitors. This immunosuppression management did not influence renal function or changes in anti-HLA antibodies 6 months after diagnosis.


Asunto(s)
COVID-19 , Trasplante de Riñón , Nefrología , Humanos , Masculino , Persona de Mediana Edad , Femenino , Tacrolimus/uso terapéutico , Estudios Retrospectivos , Ácido Micofenólico/uso terapéutico , Prednisona , Prueba de COVID-19 , ARN Viral , SARS-CoV-2 , Inmunosupresores/uso terapéutico , Terapia de Inmunosupresión , Suero Antilinfocítico
2.
Nefrologia ; 2022 Apr 30.
Artículo en Español | MEDLINE | ID: mdl-35528867

RESUMEN

INTRODUCTION: SARS CoV2 infection has had a major impact on renal transplant patients with a high mortality in the first months of the pandemic. Intentional reduction of immunosuppressive therapy has been postulated as one of the cornerstone in the management of the infection in the absence of targeted antiviral treatment. This has been modified according to the patient`s clinical situation and its effect on renal function or anti-HLA antibodies in the medium term has not been evaluated. OBJECTIVES: Evaluate the management of immunosuppressive therapy made during SARS-CoV2 infection, as well as renal function and anti-HLA antibodies in kidney transplant patients 6 months after COVID19 diagnosis. MATERIAL AND METHODS: Retrospective, national multicentre, retrospective study (30 centres) of kidney transplant recipients with COVID19 from 01/02/20 to 31/12/20. Clinical variables were collected from medical records and included in an anonymised database. SPSS statistical software was used for data analysis. RESULTS: 615 renal transplant recipients with COVID19 were included (62.6% male), with a mean age of 57.5 years.The predominant immunosuppressive treatment prior to COVID19 was triple therapy with prednisone, tacrolimus and mycophenolic acid (54.6%) followed by m-TOR inhibitor regimens (18.6%). After diagnosis of infection, mycophenolic acid was discontinued in 73.8% of patients, m-TOR inhibitor in 41.4%, tacrolimus in 10.5% and cyclosporin A in 10%. In turn, 26.9% received dexamethasone and 50.9% were started on or had their baseline prednisone dose increased.Mean creatinine before diagnosis of COVID19, at diagnosis and at 6 months was: 1.7±0.8, 2.1±1.2 and 1.8±1 mg/dl respectively (p<0.001).56.9% of the patients (N=350) were monitored for anti-HLA antibodies. 94% (N=329) had no anti-HLA changes, while 6% (N=21) had positive anti-HLA antibodies. Among the patients with donor-specific antibodies post-COVID19 (N=9), 7 patients (3.1%) had one immunosuppressant discontinued (5 patients had mycophenolic acid and 2 had tacrolimus), 1 patient had both immunosuppressants discontinued (3.4%) and 1 patient had no change in immunosuppression (1.1%), these differences were not significant. CONCLUSIONS: The management of immunosuppressive therapy after diagnosis of COVID19 was primarily based on discontinuation of mycophenolic acid with very discrete reductions or discontinuations of calcineurin inhibitors. This immunosuppression management did not influence renal function or changes in anti-HLA antibodies 6 months after diagnosis.

3.
Kidney Blood Press Res ; 43(5): 1472-1478, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30235456

RESUMEN

BACKGROUND/AIMS: A recent alert from Spanish health authorities warned of a higher incidence of reported hypersensitivity reactions to hemodialysis membranes with polysulfone, in the 2017 review of acute reactions to dialyzers found only published reports in the 21st century on polysulfone and its derivatives. The aim is to assess/evaluate the current incidence and characteristics of hypersensitivity reactions in hemodialysis patients. METHODS: A retrospective multicentre study in 9 Spanish hospitals evaluated patients in whom a hypersensitivity reaction required a change in dialyzer membrane. RESULTS: A total of 37 patients out of 1561 (2.37%) had hypersensitivity reactions and clinical, epidemiological and analytical data were available for 33 patients (2.11%). The membranes involved were polysulfone (n=23), polynephron (n=8), polyethersulfone (n=1) and polyacrylonitrile (n=1). This distribution reflected the frequency of use of membranes in the participating dialysis units. The reactions were described as type A in 18 cases and type B in 15 cases. There were no significant differences between the two types in clinical symptoms, the composition of the membrane involved, the method of sterilization, the season, or the time during the session in which they occurred. The most frequent symptom was dyspnea/breathlessness (64% of reactions). Eosinophilia was common (74%). 54% of the reactions occurred within the first 30 minutes of hemodialysis, 64% occurred during the first year of dialysis, and 54% required discontinuation of dialysis session. Cellulose triacetate was used as an alternative dialyzer in 78% of the cases. CONCLUSION: The incidence of hypersensitivity reactions was in the range found in reports from 20 years ago and is observed associated with synthetic membranes, not just polysulfones. Cellulose triacetate appears to be a good alternative for these patients.


Asunto(s)
Hipersensibilidad/etiología , Diálisis Renal/efectos adversos , Resinas Acrílicas , Anciano , Anciano de 80 o más Años , Celulosa/análogos & derivados , Celulosa/inmunología , Celulosa/uso terapéutico , Femenino , Humanos , Masculino , Membranas Artificiales , Persona de Mediana Edad , Polímeros , Diálisis Renal/instrumentación , Estudios Retrospectivos , Sulfonas/inmunología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...