Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 2 de 2
1.
Hemodial Int ; 27(2): E19-E22, 2023 04.
Article En | MEDLINE | ID: mdl-36735589

Blood leak alarms are increasingly rare and may be triggered by rupture of the dialyzer membrane, or intravascular hemolysis. We report two patients who developed hemolysis following Angiojet™ thrombolysis and thrombectomy of thrombosed arteriovenous fistulas, triggering blood leak alarms on hemodialysis, the occurrence of which has not been reported before. AngioJet™-induced hemolysis should be considered in the differential diagnosis for blood leak alarms occurring soon after an intervention on an arterio-venous (AV) fistula.


Arteriovenous Shunt, Surgical , Renal Dialysis , Humans , Renal Dialysis/adverse effects , Hemolysis , Treatment Outcome , Thrombectomy/adverse effects , Vascular Patency
2.
Vasc Endovascular Surg ; 44(5): 341-4, 2010 Jul.
Article En | MEDLINE | ID: mdl-20308167

INTRODUCTION: Renal dysfunction after endovascular aortic aneurysm repair is an increasingly recognised problem. Carbon dioxide (CO(2)) angiography has been used to limit the risk of contrast nephrotoxicity during endovascular procedures. This prospective study evaluates the performance of CO(2) angiography during EVAR. METHODS: Seventeen patients undergoing EVAR over a 12 month period were included. All were males with a median age of 74 (range 62-86) years. The median preoperative creatinine was 105 (range 77-165) micromol/L. CO(2) angiography was used routinely in all patients for graft positioning. Contrast was used for completion angiograms and whenever CO(2) did not satisfactorily demonstrate the anatomy. RESULTS: All patients had successful deployment of stent graft. The median contrast usage was 59 (range 20-250)ml. CO( 2) angiography successfully demonstrated the aortic and iliac bifurcation in all 17 cases and the renal artery anatomy in 9. 7 out of 17 patients had both CO(2) and contrast completion angiography. CO(2) correlated with contrast angiography in 6 of the 7 patients. There was no significant difference in pre and post-operative creatinine values (P >0.9; Wilcoxon test). CONCLUSION: CO(2) angiography is a useful adjunct to contrast during the performance of EVAR and helps reduce contrast load and the risk of contrast nephrotoxicity.


Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm/surgery , Aortography/methods , Blood Vessel Prosthesis Implantation , Carbon Dioxide , Contrast Media , Aged , Aged, 80 and over , Biomarkers/blood , Blood Vessel Prosthesis Implantation/adverse effects , Contrast Media/adverse effects , Creatinine/blood , Humans , Kidney Diseases/chemically induced , Kidney Diseases/prevention & control , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Renal Artery/diagnostic imaging , Time Factors , Tomography, X-Ray Computed , Treatment Outcome
...