Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 12 de 12
1.
Lab Med ; 54(5): 495-501, 2023 Sep 05.
Article En | MEDLINE | ID: mdl-36728171

OBJECTIVE: Modular workcells could be a better solution than total laboratory automation (TLA) in hemostasis laboratories. Here, we evaluated the impact of implementing a modular workcell (HemoCell) with an intelligent data management facility (HemoHub). METHODS: We compared the turnaround times (TATs), numbers of rerun samples, and rerun times pre- and postimplementation of the HemoCell at Gil Medical Center. Prothrombin time (PT), activated partial thromboplastin time (aPTT), D-dimer, and fibrinogen were evaluated. RESULTS: The TAT standard deviations (SDs) and maximum TAT values decreased after HemoCell implementation, although the mean TATs for PT, aPTT, and D-dimer were increased. Numbers of rerun samples were increased (18.1/day vs 44.7/day). However, rerun times were reduced, and SDs were decreased during the post-HemoCell period compared with pre-HemoCell. Additionally, technologists needed smaller working space and less labor. CONCLUSION: The modular workcell could improve quality and efficiency by providing more consistent TATs and shorter rerun times in the hemostasis laboratory.


Automation, Laboratory , Laboratories , Humans , Tertiary Care Centers , Blood Coagulation Tests , Hemostasis
2.
Expert Rev Hematol ; 15(2): 175-181, 2022 02.
Article En | MEDLINE | ID: mdl-35119350

OBJECTIVES: We examined the frequencies and sizes of glycosylphosphatidylinositol (GPI)-deficient cells as per the International Clinical Cytometry Society/European Society for Clinical Cell Analysis (ICCS/ESCCA) consensus guidelines for the high-sensitivity detection of GPI-deficient cells. METHODS: In 2018, the ICCS/ESCCA guidelines for the high-sensitivity detection of GPI-deficient cells were published. We evaluated frequencies and sizes of GPI-deficient red blood cells (RBCs), neutrophils, and monocytes as determined using the ICCS/ESCCA guidelines and Clinical and Laboratory Standards Institute (CLSI) guidelines in patients with a hematologic malignancy, aplastic anemia, or cytopenia. RESULTS: A total of 106 (38.7%) patients exhibited GPI deficiency in at least one blood cell lineage. GPI-deficient cells of one or more lineages were found in 62.7% of patients with a hematologic malignancy, 51.1% of patients with aplastic anemia, and 23.4% of patients with cytopenia. GPI-deficient monocytes were most frequently detected in all three groups. By population size, GPI-deficient clones (>1%) in monocytes were mostly detected in patients with a hematologic malignancy or aplastic anemia. Rare cells with GPI deficiency (<0.1%) in monocytes were most common among patients with cytopenia. CONCLUSION: High-sensitive flow cytometry analysis including monocytes may be necessary for patients with a hematologic disorder.


Anemia, Aplastic , Hematologic Neoplasms , Hemoglobinuria, Paroxysmal , Thrombocytopenia , Anemia, Aplastic/diagnosis , Anemia, Aplastic/genetics , Flow Cytometry , Glycosylphosphatidylinositols/deficiency , Hemoglobinuria, Paroxysmal/diagnosis , Hemoglobinuria, Paroxysmal/genetics , Humans , Seizures
3.
J Clin Lab Anal ; 33(5): e22869, 2019 Jun.
Article En | MEDLINE | ID: mdl-30860622

BACKGROUND: Apixaban and rivaroxaban are approved for the prevention and treatment of deep vein thrombosis (DVT), pulmonary embolism (PE), and embolic stroke in atrial fibrillation (AF) patients. The aim of this study was to find appropriate methods of monitoring the anticoagulant effects of are direct oral anticoagulants (DOACs) and establish on-therapy ranges using conventional tests. METHODS: A total of 184 samples were collected from 91 patients receiving DOACs. Concentrations of apixaban and rivaroxaban in plasma were accessed by an anti-factor Xa chromogenic assay. PT, APTT, antithrombin, D-dimer, dRVVT screen/confirm, FDP, and fibrinogen levels were measured. On-therapy ranges were calculated by substituting previously reported trough plasma concentrations of DOACs. RESULTS: Anti-factor Xa chromogenic assay-based DOACs levels were 26.0-279.5 (115.9 ± 56.5) ng/mL for apixaban at 2.5 mg BID, 19.9-565.1 (205.3 ± 162.4) ng/mL for apixaban at 5 mg BID, 2.3-395.3 (205.3 ± 162.4) ng/mL for rivaroxaban at 15 mg OD, 3.6-494.8 (119.6 ± 95.1) ng/mL for rivaroxaban at 20 mg OD, and 9.6-431.4 (140.8 ± 113.6) ng/mL for rivaroxaban at 15 mg BID. PT (%), antithrombin, and dRVVT confirm tests showed good correlation with plasma apixaban levels. Plasma rivaroxaban concentrations were correlated well with PT (sec), PT (%),and dRVVT confirm results. On-therapy ranges established for dRVVT confirm test by linear regression were as follows: 1.32-1.52 for apixaban 2.5 mg BID, 1.12-1.75 for apixaban 5 mg BID, 1.11-1.78 for rivaroxaban 15 mg OD, 1.09-1.64 for rivaroxaban 20 mg OD, and 1.22-1.81 for rivaroxaban 20 mg BID. CONCLUSIONS: Apixaban concentrations were well correlated with PT (%), antithrombin, and dRVVT confirm test. Rivaroxaban concentrations showed good correlation with PT (sec), PT (%), and dRVVT confirm test.


Blood Coagulation Tests/methods , Factor Xa Inhibitors/blood , Pyrazoles/blood , Pyridones/blood , Rivaroxaban/blood , Administration, Oral , Adult , Aged , Aged, 80 and over , Clinical Laboratory Techniques , Factor Xa Inhibitors/therapeutic use , Female , Fibrin Fibrinogen Degradation Products/analysis , Fibrinogen/analysis , Humans , Male , Middle Aged , Prothrombin Time , Pyrazoles/therapeutic use , Pyridones/therapeutic use , Rivaroxaban/therapeutic use , Viper Venoms
4.
J Clin Lab Anal ; 33(4): e22841, 2019 May.
Article En | MEDLINE | ID: mdl-30724410

BACKGROUND: Bone marrow (BM) study plays an important role as initial investigation specimen of lymphoma as well as staging lymphoma. This study aimed to investigate the utility of BM studies for classification of lymphoma and evaluate features of BM involvement by lymphoma over a period of 11 years. METHODS: A total of 1162 cases of BM studies for lymphoma evaluation were reviewed for the incidence of lymphoma subtypes, the percentage of marrow involvement, the pattern of involvement and discordance with histopathologic diagnoses of lymph nodes and other tissues. RESULTS: A total of 255 of 1162 cases underwent BM study without pathologic information, and 108 cases show lymphoma involvement. Lymph node biopsy underwent in 66 cases, and 10 cases show discordant result between BM and lymph node biopsy. Seven discordant cases were due to insufficient further studies. Lymphoma was diagnosed only by BM study in 38 cases. Abnormal lymphocytes were found in BM aspiration in 34 cases. Also, abnormal clonal lymphocytes were detected by flow cytometry in 26 cases. Four cases showed disease-related chromosomal abnormalities. FISH analysis detected abnormal findings in two cases, however, discordant with other additional studies. CONCLUSIONS: Discrepancies between the BM study and lymph node biopsy were due to insufficient further study and discordance of immunohistochemical stain result. BM study can be utilized as initial diagnosis of lymphoma by the combination of morphological feature, involvement pattern, and additional tests such as flow cytometry, chromosomal analysis, and FISH analysis. Thus, BM study with further analysis is an essential choice when lymph node biopsies are unavailable.


Bone Marrow/pathology , Lymphoma/pathology , Sentinel Lymph Node Biopsy , Humans
5.
J Obstet Gynaecol Res ; 45(1): 69-77, 2019 Jan.
Article En | MEDLINE | ID: mdl-30230126

AIM: Group B streptococcus (GBS) is a leading cause of life-threatening bacterial infections among newborns, and neonates born to heavily colonized women may be subject to vertical transmission. We sought to determine an appropriate detection method for genital GBS in pregnant women by comparing culture-based methods and real-time polymerase chain reaction (PCR). In addition, we performed molecular serotyping and multilocus sequence typing (MLST) on isolates. METHODS: A total of 150 pregnant women were enrolled and underwent vaginal-rectal swabbing at 16-40 weeks of gestation. GBS was identified by conventional culture and real-time PCR with or without enrichment. Molecular serotyping and MLST were performed on isolates. RESULTS: Overall genital GBS positive rate among the 150 study subjects was 17.3%. Direct culture identified 18 (12.0%) positive specimens, enrichment culture 22 (14.6%), direct PCR 24 (16.0%) and enrichment PCR 25 (16.6%). The sensitivity and specificity by direct and enrichment PCR were as follows: for direct PCR, 90.9% and 96.9%, respectively; and for enrichment PCR, 95.5% and 96.9%, respectively. Resistance rates to clindamycin and erythromycin were 33.3% and 19.1%, respectively. Serotype III-1 was the most common (26.3%), followed by serotype Ib (21.1%), III-3 (15.8%), V (15.8%), II (10.5%), IV (5.3%) and VI (5.3%). Most common sequence types (ST) were ST-1, ST-19 and ST-862 (15.8%), followed by ST-2 and ST-654 (10.5%). CONCLUSION: Direct real-time PCR using vaginal-rectal specimen could be used for detecting GBS in emergent conditions. Molecular serotypes III, Ib and V were most common. MLST analysis frequently presented ST-1, ST-19 and ST-862.


Genome, Bacterial , Genomics/methods , Pregnancy Complications, Infectious/microbiology , Serogroup , Streptococcal Infections/microbiology , Streptococcus/genetics , Adult , Female , Humans , Multilocus Sequence Typing/methods , Pregnancy , Pregnancy Complications, Infectious/epidemiology , Real-Time Polymerase Chain Reaction/methods , Republic of Korea/epidemiology , Serotyping/methods , Streptococcal Infections/epidemiology , Streptococcus/classification
6.
Ann Lab Med ; 38(6): 585-590, 2018 Nov.
Article En | MEDLINE | ID: mdl-30027703

BACKGROUND: Although testing to detect weak D antigens using the antihuman globulin reagent is not required for D- patients in many countries, it is routinely performed in Korea. However, weak D testing can be omitted in D- patients with a C-E- phenotype as this indicates complete deletion of the RHD gene, except in rare cases. We designed a new algorithm for weak D testing, which consisted of RhCE phenotyping followed by weak D testing in C+ or E+ samples, and compared it with the current algorithm with respect to time and cost-effectiveness. METHODS: In this retrospective study, 74,889 test results from January to July 2017 in a tertiary hospital in Korea were analyzed. Agreement between the current and proposed algorithms was evaluated, and total number of tests, time required for testing, and test costs were compared. With both algorithms, RHD genotyping was conducted for samples that were C+ or E+ and negative for weak D testing. RESULTS: The algorithms showed perfect agreement (agreement=100%; κ=1.00). By applying the proposed algorithm, 29.56% (115/389 tests/yr) of tests could be omitted, time required for testing could be reduced by 36% (8,672/24,084 min/yr), and the test cost could be reduced by 16.53% (536.11/3,241.08 USD/yr). CONCLUSIONS: Our algorithm omitting weak D testing in D- patients with C-E- phenotype may be a cost-effective testing strategy in Korea.


Algorithms , Rh-Hr Blood-Group System/genetics , Blood Grouping and Crossmatching/economics , Blood Grouping and Crossmatching/methods , Genotype , Humans , Phenotype , Retrospective Studies , Tertiary Care Centers
9.
J Clin Lab Anal ; 31(4)2017 Jul.
Article En | MEDLINE | ID: mdl-27660110

INTRODUCTION: The Mindray CAL 8000 is a cellular analysis line that consists of the BC-6800, an automated hematology analyzer, and the SC-120, an automated slidemaker/stainer. We evaluated the performances of the BC-6800 and the SC-120. METHODS: Four hundred and eight normal and abnormal samples were analyzed. The performance of the BC-6800 and Sysmex XE-2100 were compared, and blood films by the SC-120 and manual method were compared according to the CLSI guideline H26-A2 and H20-A2. RESULTS: Most parameters measured by the BC-6800 matched well with the XE-2100 and manual differential. The flag efficiency of the BC-6800 for blasts (95.3%) and atypical lymphocytes (92.6%) were higher while immature granulocytes (89.7%) and NRBCs (94.1%) were lower than that of the XE-2100. Additionally, the BC-6800 detected four of five samples infected with plasmodium parasites. The SC-120 showed no carry-over and expected repeatability. There was good agreement on the five-part differential including abnormal cells between blood films by the SC-120 and manually prepared blood films. The shape of the RBC was also comparable between blood films. CONCLUSION: The CAL-8000 analysis line is beneficial for precise, fast hematology work, and even more useful in malaria endemic areas.


Blood Cell Count/methods , Blood Cell Count/standards , Staining and Labeling/methods , Staining and Labeling/standards , Humans , Linear Models , Reproducibility of Results
10.
Ann Lab Med ; 36(5): 420-6, 2016 Sep.
Article En | MEDLINE | ID: mdl-27374706

BACKGROUND: Amino-terminal pro-B type natriuretic peptide (NT-proBNP) is a well-established prognostic factor in heart failure (HF). However, numerous causes may lead to elevations in NT-proBNP, and thus, an increased NT-proBNP level alone is not sufficient to predict outcome. The aim of this study was to evaluate the utility of two acute response markers, high sensitivity C-reactive protein (hsCRP) and heart-type fatty acid binding protein (H-FABP), in patients with an increased NT-proBNP level. METHODS: The 278 patients were classified into three groups by etiology: 1) acute coronary syndrome (ACS) (n=62), 2) non-ACS cardiac disease (n=156), and 3) infectious disease (n=60). Survival was determined on day 1, 7, 14, 21, 28, 60, 90, 120, and 150 after enrollment. RESULTS: H-FABP (P<0.001), NT-proBNP (P=0.006), hsCRP (P<0.001) levels, and survival (P<0.001) were significantly different in the three disease groups. Patients were divided into three classes by using receiver operating characteristic curves for NT-proBNP, H-FABP, and hsCRP. Patients with elevated NT-proBNP (≥3,856 pg/mL) and H-FABP (≥8.8 ng/mL) levels were associated with higher hazard ratio for mortality (5.15 in NT-proBNP and 3.25 in H-FABP). Area under the receiver operating characteristic curve analysis showed H-FABP was a better predictor of 60-day mortality than NT-proBNP. CONCLUSIONS: The combined measurement of H-FABP with NT-proBNP provides a highly reliable means of short-term mortality prediction for patients hospitalized for ACS, non-ACS cardiac disease, or infectious disease.


Acute Coronary Syndrome/diagnosis , C-Reactive Protein/analysis , Fatty Acid-Binding Proteins/blood , Natriuretic Peptide, Brain/blood , Peptide Fragments/blood , Acute Coronary Syndrome/blood , Acute Coronary Syndrome/mortality , Aged , Area Under Curve , Biomarkers/blood , Fatty Acid Binding Protein 3 , Female , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Prognosis , Proportional Hazards Models , ROC Curve
11.
Ann Lab Med ; 36(4): 291-9, 2016 Jul.
Article En | MEDLINE | ID: mdl-27139600

BACKGROUND: Mutations in calreticulin (CALR) have been reported to be key markers in the molecular diagnosis of myeloid proliferative neoplasms. In most previous reports, CALR mutations were analyzed by using Sanger sequencing. Here, we report a new, rapid, and convenient system for screening CALR mutations without sequencing. METHODS: Eighty-three bone marrow samples were obtained from 81 patients with thrombocytosis. PCR primers were designed to detect wild-type CALR (product: 357 bp) and CALR with type 1 (product: 302 bp) and type 2 mutations (product: 272 bp) in one reaction. The results were confirmed by Sanger sequencing and compared with results from fragment analysis. RESULTS: The minimum detection limit of the screening PCR was 10 ng for type 1, 1 ng for type 2, and 0.1 ng for cases with both mutations. CALR type 1 and type 2 mutants were detected with screening PCR with a maximal analytical sensitivity of 3.2% and <0.8%, respectively. The screening PCR detected 94.1% (16/17) of mutation cases and showed concordant results with sequencing in the cases of type 1 and type 2 mutations. Sanger sequencing identified one novel mutation (c.1123_1132delinsTGC). Compared with sequencing, the screening PCR showed 94.1% sensitivity, 100.0% specificity, 100.0% positive predictive value, and 98.5% negative predictive value. Compared with fragment analysis, the screening PCR presented 88.9% sensitivity and 100.0% specificity. CONCLUSIONS: This screening PCR is a rapid, sensitive, and cost-effective method for the detection of major CALR mutations.


Calreticulin/genetics , Myeloproliferative Disorders/diagnosis , Thrombocytosis/diagnosis , Adult , Aged , Base Sequence , Bone Marrow/metabolism , Calreticulin/chemistry , Calreticulin/metabolism , DNA Mutational Analysis , Female , Follow-Up Studies , Genotype , Humans , Janus Kinase 2/chemistry , Janus Kinase 2/genetics , Janus Kinase 2/metabolism , Male , Middle Aged , Mutation , Myeloproliferative Disorders/complications , Myeloproliferative Disorders/genetics , Polymerase Chain Reaction , Thrombocytosis/complications
...