Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Exp Physiol ; 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38984642

RESUMEN

We investigated the effects of resistance exercise (RE), hydrolysed collagen (HC) ingestion and circulating oestrogen concentration on collagen synthesis in a naturally menstruating female CrossFit athlete. In a double-blind, randomised cross-over design, the participant (36 years; height 1.61 m; mass 82.6 kg) consumed 0 or 30 g HC prior to performing back-squat RE when endogenous circulating oestrogen concentration was low (onset of menses, OM) and high (late follicular phase, LF) during two consecutive menstrual cycles. Ten 5-mL blood samples were collected during each of the four interventions to analyse concentrations of serum 17ß-oestradiol, and biomarkers of type I collagen turnover, that is serum procollagen type I N-terminal propeptide (PINP, a biomarker of collagen synthesis) and plasma ß-isomerised C-terminal telopeptide of type I collagen (ß-CTX, a biomarker of collagen breakdown), as well as the serum concentration of 18 collagen amino acids. 17ß-Oestradiol concentration was 5-fold higher at LF (891 ± 116 pmol L-1) than OM (180 ± 13 pmol L-1). The PINP concentration × time area under the curve (AUC) was higher in the 30 g HC OM intervention (201 µg L-1 h) than the 30 g HC LF (144 µg L-1 h), 0 g HC OM (151 µg L-1 h) and 0 g HC LF (122 µg L-1 h) interventions. ß-CTX concentration decreased 1.4-fold from pre-RE to 6 h post-RE in all interventions. Thus, high circulating oestrogen concentration was associated with lower collagen synthesis following RE in this female athlete. Ingesting 30 g HC, however, augmented the collagen synthesis response at LF and particularly at OM. HIGHLIGHTS: What is the central question of this study? Does resistance exercise-induced collagen synthesis vary according to circulating oestrogen concentration in a naturally menstruating female athlete, and if so, does hydrolysed collagen ingestion have any impact? What is the main finding and its importance? Exercise-induced collagen synthesis was low when circulating oestrogen concentration was high and vice versa. However, ingesting 30 g hydrolysed collagen prior to exercise reduced the negative effect of oestrogen on collagen synthesis. As high circulating oestrogen has been associated with greater injury risk in females, supplementing exercise with hydrolysed collagen may help protect these tissues from injury.

2.
Eur J Radiol ; 175: 111471, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38636411

RESUMEN

PURPOSE: With the slice thickness routinely used in elbow MRI, small or subtle lesions may be overlooked or misinterpreted as insignificant. To compare 1 mm slice thickness MRI (1 mm MRI) with deep learning reconstruction (DLR) to 3 mm slice thickness MRI (3 mm MRI) without/with DLR, and 1 mm MRI without DLR regarding image quality and diagnostic performance for elbow tendons and ligaments. METHODS: This retrospective study included 53 patients between February 2021 and January 2022, who underwent 3 T elbow MRI, including T2-weighted fat-saturated coronal 3 mm and 1 mm MRI without/with DLR. Two radiologists independently assessed four MRI scans for image quality and artefacts, and identified the pathologies of the five elbow tendons and ligaments. In 19 patients underwent elbow surgery after elbow MRI, diagnostic performance was evaluated using surgical records as a reference standard. RESULTS: For both readers, 3 mm MRI with DLR had significant higher image quality scores than 3 mm MRI without DLR and 1 mm MRI with DLR (all P < 0.01). For common extensor tendon and elbow ligament pathologies, 1 mm MRI with DLR showed the highest number of pathologies for both readers. The 1 mm MRI with DLR had the highest kappa values for all tendons and ligaments. For reader 1, 1 mm MRI with DLR showed superior diagnostic performance than 3 mm MRI without/with DLR. For reader 2, 1 mm MRI with DLR showed the highest diagnostic performance; however, there was no significant difference. CONCLUSIONS: One mm MRI with DLR showed the highest diagnostic performance for evaluating elbow tendon and ligament pathologies, with similar subjective image qualities and artefacts.


Asunto(s)
Aprendizaje Profundo , Articulación del Codo , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Adulto , Articulación del Codo/diagnóstico por imagen , Anciano , Ligamentos Articulares/diagnóstico por imagen , Ligamentos Articulares/lesiones , Ligamentos/diagnóstico por imagen , Adulto Joven , Tendones/diagnóstico por imagen
3.
Eur Radiol ; 34(8): 5379-5388, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38231393

RESUMEN

OBJECTIVE: Blood-labyrinthine barrier leakage has been reported in sudden sensorineural hearing loss (SSNHL). We compared immediate post-contrast 3D heavily T2-weighted fluid-attenuated inversion recovery (FLAIR), T1 spin echo (SE), and 3D T1 gradient echo (GRE) sequences, and heavily T2-weighted FLAIR (hvT2F) with and without deep learning-based reconstruction (DLR) in detecting perilymphatic enhancement. METHODS: Fifty-four patients with unilateral SSNHL who underwent ear MRI with three sequences were included. We compared asymmetry scores, confidence scores, and detection rates of perilymphatic enhancement among the three sequences and obtained 3D hvT2F with DLR from 35 patients. The above parameters and subjective image quality between 3D hvT2F with and without DLR were compared. RESULTS: Asymmetry scores and detection rate of 3D hvT2F were significantly higher than 3D GRE T1 and SE T1 (respectively, 1.37, 0.11, 0.19; p < 0.001). Asymmetry scores significantly increased with DLR compared to 3D hvT2F for experienced and inexperienced readers (respectively, 1.77 vs. 1.40, p = 0.036; 1.49 vs. 1.03, p = 0.012). The detection rate significantly increased only for the latter (57.1% vs. 31.4%, p = 0.022). Patients with perilymphatic enhancement had significantly higher air conduction thresholds on initial (77.96 vs. 57.79, p = 0.002) and 5 days after presentation (63.38 vs. 41.85, p = 0.019). CONCLUSION: 3D hvT2F significantly increased the detectability of perilymphatic enhancement compared to 3D GRE T1 and SE T1. DLR further improved the conspicuity of perilymphatic enhancement in 3D hvT2F. 3D hvT2F and DLR are useful for evaluating blood-labyrinthine barrier leakage; furthermore, they might provide prognostic value in the early post-treatment period. CLINICAL RELEVANCE STATEMENT: Ten-minute post-contrast 3D heavily T2-weighed FLAIR imaging is a potentially efficacious sequence in demonstrating perilymphatic enhancement in patients with sudden sensorineural hearing loss and may be further improved by deep learning-based reconstruction. KEY POINTS: • 3D heavily T2-weighted FLAIR (3D hvT2F) is a sequence sensitive in detecting low concentrations of contrast in the perilymphatic space. • 3D hvT2F sequences properly demonstrated perilymphatic enhancement in sudden sensorineural hearing loss compared to T1 sequences and were further improved by deep learning-based reconstruction (DLR). • 3D hvT2F and DLR are efficacious sequences in detecting blood-labyrinthine barrier leakage and with potential prognostic information.


Asunto(s)
Aprendizaje Profundo , Pérdida Auditiva Sensorineural , Pérdida Auditiva Súbita , Imagenología Tridimensional , Imagen por Resonancia Magnética , Humanos , Masculino , Femenino , Persona de Mediana Edad , Pérdida Auditiva Sensorineural/diagnóstico por imagen , Imagenología Tridimensional/métodos , Adulto , Imagen por Resonancia Magnética/métodos , Anciano , Pérdida Auditiva Súbita/diagnóstico por imagen , Oído Interno/diagnóstico por imagen , Adulto Joven , Estudios Retrospectivos , Medios de Contraste , Interpretación de Imagen Asistida por Computador/métodos
4.
Quant Imaging Med Surg ; 14(1): 722-735, 2024 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-38223037

RESUMEN

Background: While anti-peristaltic agents are beneficial for high quality magnetic resonance enterography (MRE), their use is constrained by potential side effects and increased examination complexity. We explored the potential of deep learning-based reconstruction (DLR) to compensate for the absence of anti-peristaltic agent, improve image quality and reduce artifact. This study aimed to evaluate the need for an anti-peristaltic agent in single breath-hold single-shot fast spin-echo (SSFSE) MRE and compare the image quality and artifacts between conventional reconstruction (CR) and DLR. Methods: We included 45 patients who underwent MRE for Crohn's disease between October 2021 and September 2022. Coronal SSFSE images without fat saturation were acquired before and after anti-peristaltic agent administration. Four sets of data were generated: SSFSE CR with and without an anti-peristaltic agent (CR-A and CR-NA, respectively) and SSFSE DLR with and without an anti-peristaltic agent (DLR-A and DLR-NA, respectively). Two radiologists independently reviewed the images for overall quality and artifacts, and compared the three images with DLR-A. The degree of distension and inflammatory parameters were scored on a 5-point scale in the jejunum and ileum, respectively. Signal-to-noise ratio (SNR) levels were calculated in superior mesenteric artery (SMA) and iliac bifurcation level. Results: In terms of overall quality, DLR-NA demonstrated no significant difference compared to DLR-A, whereas CR-NA and CR-A demonstrated significant differences (P<0.05, both readers). Regarding overall artifacts, reader 1 rated DLR-A slightly better than DLR-NA in four cases and rated them as identical in 41 cases (P=0.046), whereas reader 2 demonstrated no difference. Bowel distension was significantly different in the jejunum (Reader 1: P=0.046; Reader 2: P=0.008) but not in the ileum. Agreements between the images (Reader 1: ĸ=0.73-1.00; Reader 2: ĸ=1.00) and readers (ĸ=0.66 for all comparisons) on inflammation were considered good to excellent. The sensitivity, specificity, and accuracy in diagnosing inflammation in the terminal ileum were the same among DLR-NA, DLR-A, CR-NA and CR-A (94.42%, 81.83%, and 89.69 %; and 83.33%, 90.91%, and 86.21% for Readers 1 and 2, respectively). In both SMA and iliac bifurcation levels, SNR of DLR images exhibited no significant differences. CR images showed significantly lower SNR compared with DLR images (P<0.001). Conclusions: SSFSE without anti-peristaltic agents demonstrated nearly equivalent quality to that with anti-peristaltic agents. Omitting anti-peristaltic agents before SSFSE and adding DLR could improve the scanning outcomes and reduce time.

5.
J Korean Soc Radiol ; 84(6): 1309-1323, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38107694

RESUMEN

Purpose: To assess the quality of four images obtained using single-breath-hold (SBH), single-shot fast spin-echo (SSFSE) and multiple-breath-hold (MBH) SSFSE with and without deep-learning based reconstruction (DLR) in patients with Crohn's disease. Materials and Methods: This study included 61 patients who underwent MR enterography (MRE) for Crohn's disease. The following images were compared: SBH-SSFSE with (SBH-DLR) and without (SBH-conventional reconstruction [CR]) DLR and MBH-SSFSE with (MBH-DLR) and without (MBH-CR) DLR. Two radiologists independently reviewed the overall image quality, artifacts, sharpness, and motion-related signal loss using a 5-point scale. Three inflammatory parameters were evaluated in the ileum, the terminal ileum, and the colon. Moreover, the presence of a spatial misalignment was evaluated. Signal-to-noise ratio (SNR) was calculated at two locations for each sequence. Results: DLR significantly improved the image quality, artifacts, and sharpness of the SBH images. No significant differences in scores between MBH-CR and SBH-DLR were detected. SBH-DLR had the highest SNR (p < 0.001). The inter-reader agreement for inflammatory parameters was good to excellent (κ = 0.76-0.95) and the inter-sequence agreement was nearly perfect (κ = 0.92-0.94). Misalignment artifacts were observed more frequently in the MBH images than in the SBH images (p < 0.001). Conclusion: SBH-DLR demonstrated equivalent quality and performance compared to MBH-CR. Furthermore, it can be acquired in less than half the time, without multiple BHs and reduce slice misalignments.

6.
J Nutr ; 2023 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-38007183

RESUMEN

BACKGROUND: Resistance exercise (RE) stimulates collagen synthesis in skeletal muscle and tendon but there is limited and equivocal evidence regarding an effect of collagen supplementation and exercise on collagen synthesis. Furthermore, it is not known if a dose-response exists regarding the effect of hydrolyzed collagen (HC) ingestion and RE on collagen synthesis. OBJECTIVE: To determine the HC dose-response effect on collagen synthesis after high-intensity RE in resistance-trained young men. METHODS: Using a double-blind, randomized crossover design, 10 resistance-trained males (age: 26 ± 3 y; height: 1.77 ± 0.04 m; mass: 79.7 ± 7.0 kg) ingested 0 g, 15 g, or 30 g HC with 50 mg vitamin C 1 h before performing 4 sets' barbell back squat RE at 10-repetition maximum load, after which they rested for 6 h. Blood samples were collected throughout each of the 3 interventions to analyze procollagen type Ⅰ N-terminal propeptide (PINP) and ß-isomerized C-terminal telopeptide of type I collagen (ß-CTX) concentration, and the concentration of 18 collagen amino acids. RESULTS: The serum PINP concentration × time area under the curve (AUC) was greater for 30 g (267 ± 79 µg·L-1·h) than for 15 g (235 ± 70 µg·L-1·h, P = 0.013) and 0 g HC (219 ± 88 µg·L-1·h, P = 0.002) but there was no difference between 0 and 15 g HC (P = 0.225). The AUCs of glycine and proline were greater for 30 g than for 15 and 0 g HC (P < 0.05). Plasma ß-CTX concentration decreased from -1 to +6 h (P < 0.05), with no differences between interventions. CONCLUSIONS: Ingesting 30 g HC before high-intensity RE augments whole-body collagen synthesis more than 15 g and 0 g HC in resistance-trained young males.

7.
Diagn Interv Radiol ; 29(3): 437-449, 2023 05 31.
Artículo en Inglés | MEDLINE | ID: mdl-37098650

RESUMEN

PURPOSE: This study aimed to compare near-isotropic contrast-enhanced T1-weighted (CE-T1W) magnetic resonance enterography (MRE) images reconstructed with vendor-supplied deep-learning reconstruction (DLR) with those reconstructed conventionally in terms of image quality. METHODS: A total of 35 patients who underwent MRE for Crohn's disease between August 2021 and February 2022 were included in this retrospective study. The enteric phase CE-T1W MRE images of each patient were reconstructed with conventional reconstruction and no image filter (original), with conventional reconstruction and image filter (filtered), and with a prototype version of AIRTM Recon DL 3D (DLR), which were then reformatted into the axial plane to generate six image sets per patient. Two radiologists independently assessed the images for overall image quality, contrast, sharpness, presence of motion artifacts, blurring, and synthetic appearance for qualitative analysis, and the signal-to-noise ratio (SNR) was measured for quantitative analysis. RESULTS: The mean scores of the DLR image set with respect to overall image quality, contrast, sharpness, motion artifacts, and blurring in the coronal and axial images were significantly superior to those of both the filtered and original images (P < 0.001). However, the DLR images showed a significantly more synthetic appearance than the other two images (P < 0.05). There was no statistically significant difference in all scores between the original and filtered images (P > 0.05). In the quantitative analysis, the SNR was significantly increased in the order of original, filtered, and DLR images (P < 0.001). CONCLUSION: Using DLR for near-isotropic CE-T1W MRE improved the image quality and increased the SNR.


Asunto(s)
Enfermedad de Crohn , Aprendizaje Profundo , Humanos , Enfermedad de Crohn/diagnóstico por imagen , Enfermedad de Crohn/patología , Estudios Retrospectivos , Mejoramiento de la Calidad , Medios de Contraste , Espectroscopía de Resonancia Magnética , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
8.
Skeletal Radiol ; 52(8): 1545-1555, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36943429

RESUMEN

OBJECTIVE: To compare the image quality and agreement among conventional and accelerated periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) MRI with both conventional reconstruction (CR) and deep learning-based reconstruction (DLR) methods for evaluation of shoulder. MATERIALS AND METHODS: We included patients who underwent conventional (acquisition time, 8 min) and accelerated (acquisition time, 4 min and 24 s; 45% reduction) PROPELLER shoulder MRI using both CR and DLR methods between February 2021 and February 2022 on a 3 T MRI system. Quantitative evaluation was performed by calculating the signal-to-noise ratio (SNR). Two musculoskeletal radiologists compared the image quality using conventional sequence with CR as the reference standard. Interobserver agreement between image sets for evaluating shoulder was analyzed using weighted/unweighted kappa statistics. RESULTS: Ninety-two patients with 100 shoulder MRI scans were included. Conventional sequence with DLR had the highest SNR (P < .001), followed by accelerated sequence with DLR, conventional sequence with CR, and accelerated sequence with CR. Comparison of image quality by both readers revealed that conventional sequence with DLR (P = .003 and P < .001) and accelerated sequence with DLR (P = .016 and P < .001) had better image quality than the conventional sequence with CR. Interobserver agreement was substantial to almost perfect for detecting shoulder abnormalities (κ = 0.600-0.884). Agreement between the image sets was substantial to almost perfect (κ = 0.691-1). CONCLUSION: Accelerated PROPELLER with DLR showed even better image quality than conventional PROPELLER with CR and interobserver agreement for shoulder pathologies comparable to that of conventional PROPELLER with CR, despite the shorter scan time.


Asunto(s)
Aprendizaje Profundo , Hombro , Humanos , Hombro/diagnóstico por imagen , Artefactos , Imagen por Resonancia Magnética/métodos , Relación Señal-Ruido
9.
Front Physiol ; 14: 1089971, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36776971

RESUMEN

We investigated the effect of collagen hydrolysate supplementation on changes in patellar tendon (PT) properties after 10 weeks' training in female soccer players from a Football Association Women's Super League Under 21 s squad. We pair-matched n = 17 players (age: 17 ± 0.9 years; height: 1.66 ± 0.06 m; mass: 58.8 ± 8.1 kg) for baseline knee extension (KE) maximum isometric voluntary contraction (MIVC) torque, age, height, and body mass, and randomly assigned them to collagen (COL) or placebo (PLA) groups (COL n = 8, PLA n = 9). Participants consumed 30 g collagen hydrolysate supplementation or energy-matched PLA (36.5 g maltodextrin, 8.4 g fructose) and plus both groups consumed 500 mg vitamin C, after each training session, which comprised bodyweight strength-, plyometric- and/or pitch-based exercise 3 days/week for 10 weeks in-season. We assessed KE MIVC torque, vastus lateralis muscle thickness and PT properties using isokinetic dynamometry and ultrasonography before and after 10 weeks' soccer training. KE MIVC torque, muscle thickness and tendon cross-sectional area did not change after training in either group. However, COL increased PT stiffness [COL, +18.0 ± 12.2% (d = 1.11) vs. PLA, +5.1 ± 10.4% (d = 0.23), p = 0.049] and Young's modulus [COL, +17.3 ± 11.9% (d = 1.21) vs. PLA, +4.8 ± 10.3% (d = 0.23), p = 0.035] more than PLA. Thus, 10 weeks' in-season soccer training with COL increased PT mechanical and material properties more than soccer training alone in high-level female soccer players. Future studies should investigate if collagen hydrolysate supplementation can improve specific aspects of female soccer performance requiring rapid transference of force, and if it can help mitigate injury risk in this under-researched population.

10.
Eur J Radiol ; 158: 110647, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36527773

RESUMEN

PURPOSE: To compare performance of 1-mm deep learning reconstruction (DLR) with 3-mm routine MRI imaging for the delineation of pituitary axis and identification of cavernous sinus invasion for pituitary macroadenoma. METHOD: This retrospective study included 104 patients (59.4 ± 13.1 years; 46 women) who underwent an MRI protocol including 1-mm deep learning-reconstructed and 3-mm routine images for evaluating pituitary adenoma between August 2019 and October 2020. Five readers (24, 9, 2 years, and <1 year of experience) assessed the delineation of pituitary axis (gland and stalk) and the presence of cavernous sinus invasion for using a pairwise design. The signal-to-noise ratio (SNR) was measured. Diagnostic performance as well as image preference data were analysed and compared according to the readers' experience using the McNemar test. RESULTS: For delineation of normal pituitary axis, all readers preferred thin 1-mm DLR MRI over 3-mm MRI (overall superiority, 55.8 %, P <.001), with this preference being greater in the less experienced readers (92.3 % vs. 55.8 % [expert], P <.001). The readers showed higher diagnostic performance for cavernous sinus invasion on 1-mm (AUC, 0.91 and 0.92) than on 3-mm imaging (AUC, 0.87 and 0.88). The SNR of the 1-mm DLR was 1.21-fold higher than that of the routine 3-mm imaging. CONCLUSION: Deep learning reconstruction-based 1-mm imaging demonstrates improved image quality and better delineation of microstructure in the sellar fossa and is preferred by both radiologists and non-radiologist physicians, especially in less experienced readers.


Asunto(s)
Adenoma , Seno Cavernoso , Aprendizaje Profundo , Enfermedades de la Hipófisis , Neoplasias Hipofisarias , Humanos , Femenino , Neoplasias Hipofisarias/diagnóstico por imagen , Neoplasias Hipofisarias/cirugía , Estudios Retrospectivos , Seno Cavernoso/diagnóstico por imagen , Invasividad Neoplásica , Imagen por Resonancia Magnética/métodos , Adenoma/diagnóstico por imagen , Adenoma/cirugía , Procesamiento de Imagen Asistido por Computador
11.
Adapt Phys Activ Q ; 40(3): 541-550, 2023 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-36577422

RESUMEN

South Korea has developed its first Para Report Card on physical activity (PA) for children and adolescents with disabilities. Five national surveillance databases were used to evaluate PA indicators based on the benchmarks and grading rubric provided by Active Healthy Kids Global Alliance. Report card evaluation committees were invited to grade and assess the results using strengths, weaknesses, opportunities, and threats analysis. Five indicators (overall PA, D+; organized sports and PA, D-; active transportation, D-; physical fitness, D+; and government, A+) and one additional indicator (sleep, C-) were assigned a letter grade. The other five indicators were graded as incomplete. The Para Report Card revealed a significant gap between the behavioral-indicator grades (D- to D+) and the policy-indicator grade (A+), suggesting that government strategies and investment have not yet been translated into behavioral PA among children and adolescents with disabilities.


Asunto(s)
Personas con Discapacidad , Conducta Sedentaria , Humanos , Niño , Adolescente , Política de Salud , Promoción de la Salud , Ejercicio Físico , República de Corea
12.
Quant Imaging Med Surg ; 12(3): 2002-2017, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35284250

RESUMEN

Background: Diffusion-weighted imaging plays a key role in magnetic resonance imaging (MRI) of breast tumors. However, it remains unclear how to interpret single diffusion encoding with respect to its link with tissue microstructure. The purpose of this retrospective cross-sectional study was to use tensor-valued diffusion encoding to investigate the underlying microstructure of invasive ductal carcinoma (IDC) and evaluate its potential value in a clinical setting. Methods: We retrospectively reviewed biopsy-proven breast cancer patients who underwent preoperative breast MRI examination from July 2020 to March 2021. We reviewed the MRI of 29 patients with 30 IDCs, including analysis by diffusional variance decomposition enabled by tensor-valued diffusion encoding. The diffusion parameters of mean diffusivity (MD), total mean kurtosis (MKT), anisotropic mean kurtosis (MKA), isotropic mean kurtosis (MKI), macroscopic fractional anisotropy (FA), and microscopic fractional anisotropy (µFA) were estimated. The parameter differences were compared between IDC and normal fibroglandular breast tissue (FGBT), as well as the association between the diffusion parameters and histopathologic items. Results: The mean value of MD in IDCs was significantly lower than that of normal FGBT (1.07±0.27 vs. 1.34±0.29, P<0.001); however, MKT, MKA, MKI, FA, and µFA were significantly higher (P<0.005). Among all the diffusion parameters, MKI was positively correlated with the tumor size on both MRI and pathological specimen (rs=0.38, P<0.05 vs. rs=0.54, P<0.01), whereas MKT had a positive correlation with the tumor size in the pathological specimen only (rs=0.47, P<0.02). In addition, the lymph node (LN) metastasis group had significantly higher MKT, MKA, and µFA compared to the metastasis negative group (P<0.05). Conclusions: Tensor-valued diffusion encoding enables a useful non-invasive method for characterizing breast cancers with information on tissue microstructures. Particularly, µFA could be a potential imaging biomarker for evaluating breast cancers prior to surgery or chemotherapy.

13.
Diagnostics (Basel) ; 12(1)2022 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-35054316

RESUMEN

(1) Background: Highly flexible adaptive image receive (AIR) coil has become available for clinical use. The present study aimed to evaluate the performance of AIR anterior array coil in lung MR imaging using a zero echo time (ZTE) sequence compared with conventional anterior array (CAA) coil. (2) Methods: Sixty-six patients who underwent lung MR imaging using both AIR coil (ZTE-AIR) and CAA coil (ZTE-CAA) were enrolled. Image quality of ZTE-AIR and ZTE-CAA was quantified by calculating blur metric value, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of lung parenchyma. Image quality was qualitatively assessed by two independent radiologists. Lesion detection capabilities for lung nodules and emphysema and/or lung cysts were evaluated. Patients' comfort levels during examinations were assessed. (3) Results: SNR and CNR of lung parenchyma were higher (both p < 0.001) in ZTE-AIR than in ZTE-CAA. Image sharpness was superior in ZTE-AIR (p < 0.001). Subjective image quality assessed by two independent readers was superior (all p < 0.05) in ZTE-AIR. AIR coil was preferred by 64 of 66 patients. ZTE-AIR showed higher (all p < 0.05) sensitivity for sub-centimeter nodules than ZTE-CAA by both readers. ZTE-AIR showed higher (all p < 0.05) sensitivity and accuracy for detecting emphysema and/or cysts than ZTE-CAA by both readers. (4) Conclusions: The use of highly flexible AIR coil in ZTE lung MR imaging can improve image quality and patient comfort. Application of AIR coil in parenchymal imaging has potential for improving delineation of low-density parenchymal lesions and tiny nodules.

14.
AJR Am J Roentgenol ; 218(3): 506-516, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34523950

RESUMEN

BACKGROUND. Shoulder MRI using standard multiplanar sequences requires long scan times. Accelerated sequences have tradeoffs in noise and resolution. Deep learning-based reconstruction (DLR) may allow reduced scan time with preserved image quality. OBJECTIVE. The purpose of this study was to compare standard shoulder MRI sequences and accelerated sequences without and with DLR in terms of image quality and diagnostic performance. METHODS. This retrospective study included 105 patients (45 men, 60 women; mean age, 57.6 ± 10.9 [SD] years) who underwent a total of 110 3-T shoulder MRI examinations. Examinations included standard sequences (scan time, 9 minutes 23 seconds) and accelerated sequences (3 minutes 5 seconds; 67% reduction), both including fast spin-echo sequences in three planes. Standard sequences were reconstructed using the conventional pipeline; accelerated sequences were reconstructed using both the conventional pipeline and a commercially available DLR pipeline. Two radiologists independently assessed three image sets (standard sequence, accelerated sequence without DLR, and accelerated sequence with DLR) for subjective image quality and artifacts using 4-point scales (4 = highest quality) and identified pathologies of the subscapularis tendon, supraspinatus-infraspinatus tendon, long head of the biceps brachii tendon, and glenoid labrum. Interobserver agreement and agreement between image sets for the evaluated pathologies were assessed using weighted kappa statistics. In 27 patients who underwent arthroscopy, diagnostic performance was calculated using arthroscopic findings as a reference standard. RESULTS. Mean subjective image quality scores for readers 1 and 2 were 10.6 ± 1.2 and 10.5 ± 1.4 for the standard sequence, 8.1 ± 1.3 and 7.2 ± 1.1 for the accelerated sequence without DLR, and 10.7 ± 1.2 and 10.5 ± 1.6 for the accelerated sequence with DLR. Mean artifact scores for readers 1 and 2 were 9.3 ± 1.2 and 10.0 ± 1.0 for the standard sequence, 7.3 ± 1.3 and 9.1 ± 0.8 for the accelerated sequence without DLR, and 9.4 ± 1.2 and 9.8 ± 0.8 for the accelerated sequence with DLR. Interobserver agreement ranged from kappa of 0.813-0.951 except for accelerated sequence without DLR for the supraspinatus-infraspinatus tendon (κ = 0.673). Agreement between image sets ranged from kappa of 0.809-0.957 except for reader 1 for supraspinatus-infraspinatus tendon (κ = 0.663-0.700). Accuracy, sensitivity, and specificity for tears of the four structures were not different (p > .05) among image sets. CONCLUSION. Accelerated sequences with DLR provide 67% scan time reduction with similar subjective image quality, artifacts, and diagnostic performance to standard sequences. CLINICAL IMPACT. Accelerated sequences with DLR may provide an alternative to standard sequences for clinical shoulder MRI.


Asunto(s)
Aprendizaje Profundo , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Lesiones del Hombro/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Articulación del Hombro/diagnóstico por imagen
15.
Sci Rep ; 11(1): 21302, 2021 10 29.
Artículo en Inglés | MEDLINE | ID: mdl-34716372

RESUMEN

Even a tiny functioning pituitary adenoma could cause symptoms; hence, accurate diagnosis and treatment are crucial for management. However, it is difficult to diagnose a small pituitary adenoma using conventional MR sequence. Deep learning-based reconstruction (DLR) using magnetic resonance imaging (MRI) enables high-resolution thin-section imaging with noise reduction. In the present single-institution retrospective study of 201 patients, conducted between August 2019 and October 2020, we compared the performance of 1 mm DLR MRI with that of 3 mm routine MRI, using a combined imaging protocol to detect and delineate pituitary adenoma. Four readers assessed the adenomas in a pairwise fashion, and diagnostic performance and image preferences were compared between inexperienced and experienced readers. The signal-to-noise ratio (SNR) was quantitatively assessed. New detection of adenoma, achieved using 1 mm DLR MRI, was not visualised using 3 mm routine MRI (overall: 6.5% [13/201]). There was no significant difference depending on the experience of the readers in new detections. Readers preferred 1 mm DLR MRI over 3 mm routine MRI (overall superiority 56%) to delineate normal pituitary stalk and gland, with inexperienced readers more preferred 1 mm DLR MRI than experienced readers. The SNR of 1 mm DLR MRI was 1.25-fold higher than that of the 3 mm routine MRI. In conclusion, the 1 mm DLR MRI achieved higher sensitivity in the detection of pituitary adenoma and provided better delineation of normal pituitary gland than 3 mm routine MRI.


Asunto(s)
Adenoma/diagnóstico por imagen , Aprendizaje Profundo , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Neoplasias Hipofisarias/diagnóstico por imagen , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
16.
NMR Biomed ; 34(8): e4561, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34080736

RESUMEN

An increase in hyperpolarized (HP) [1-13 C]lactate production has been suggested as a biomarker for cancer occurrence as well as for response monitoring of cancer treatment. Recently, the use of metformin has been suggested as an anticancer or adjuvant treatment. By regulating the cytosolic NAD+ /NADH redox state, metformin stimulates lactate production and increases the HP [1-13 C]lactate conversion rate in the kidney, liver, and heart. In general, increased HP [1-13 C]lactate is regarded as a sign of cancer occurrence or tumor growth. Thus, the relationship between the tumor suppression effect of metformin and the change in metabolism monitored by HP [1-13 C]pyruvate MRS in cancer treatment needs to be investigated. The present study was performed using a brain metastasis animal model with MDA-MB-231(BR)-Luc breast cancer cells. HP [1-13 C]pyruvate MRS, T2 -weighted MRI, and bioluminescence imaging were performed in groups treated with metformin or adjuvant metformin and radiation therapy. Metformin treatment alone did not display a tumor suppression effect, and the HP [1-13 C]lactate conversion rate increased. In radiation therapy, the HP [1-13 C]lactate conversion rate decreased with tumor suppression, with a p-value of 0.028. In the adjuvant metformin and radiation treatment, the tumor suppression effect increased, with a p-value of 0.001. However, the apparent HP [1-13 C]lactate conversion rate (Kpl ) was observed to be offset by two opposite effects: a decrease on radiation therapy and an increase caused by metformin treatment. Although HP [1-13 C]pyruvate MRS could not evaluate the tumor suppression effect of adjuvant metformin and radiation therapy due to the offset phenomenon, metabolic changes following only metformin pre-treatment could be monitored. Therefore, our results indicate that the interpretation of HP [1-13 C]pyruvate MRS for response monitoring of cancer treatment should be carried out with caution when metformin is used as an adjuvant cancer therapy.


Asunto(s)
Adyuvantes Farmacéuticos/farmacología , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/radioterapia , Isótopos de Carbono/química , Ácido Láctico/metabolismo , Imagen por Resonancia Magnética , Metformina/farmacología , Radiación Ionizante , Animales , Apoptosis , Neoplasias Encefálicas/secundario , Línea Celular Tumoral , Femenino , Humanos , Ratones Endogámicos BALB C , Ratones Desnudos , Modelos Biológicos , Ácido Pirúvico/metabolismo , Ensayos Antitumor por Modelo de Xenoinjerto
17.
Eur Radiol ; 31(9): 6438-6445, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33609144

RESUMEN

OBJECTIVES: High cochlear signal intensity on three-dimensional (3D) T2 fluid-attenuated inversion recovery (FLAIR) sequences in patients with sudden sensorineural hearing loss (SSNHL) has been reported. Here, we evaluated the cochlear T2 relaxation time differences in patients with idiopathic SSNHL using quantitative synthetic MRI (SyMRI). METHODS: Twenty-four patients with unilateral SSNHL who underwent precontrast conventional 3D FLAIR and SyMRI were retrospectively included. T1 and T2 relaxation times and the proton density (PD) of the bilateral ears were measured by manually drawn regions of interest. Wilcoxon signed-rank tests and intra- and interobserver correlation analyses were performed. Qualitative analysis was also performed to determine the presence and laterality of the asymmetric high signal intensity on synthetic FLAIR (SyFLAIR) images. RESULTS: The T2 relaxation time was significantly lower in the affected (basal and apico-middle turns) than in the unaffected cochlea (basal turn: 519 ± 181.3 vs. 608.8 ± 203.6, p = 0.042; apico-middle turn: 410.8 ± 163.8 vs. 514.5 ± 186.3, p = 0.037). There were no significant differences in the T1 relaxation time and PD between the affected and unaffected ears (p > 0.05). Additionally, three patients without asymmetric signal intensity on conventional MRI showed asymmetric increased signal intensity in the affected ear on SyFLAIR. CONCLUSIONS: The T2 relaxation time was significantly shorter in the affected than in the unaffected cochlea of patients with idiopathic SSNHL. The SyMRI-derived T2 relaxation time may be a promising imaging marker, suggesting that the changes in inner ear fluid composition are implicated in the idiopathic SSNHL development. KEY POINTS: • T2 relaxation time was significantly lower in the affected than in the unaffected cochlea. • SyFLAIR showed increased lesion conspicuity compared to conventional 3D-FLAIR in detecting asymmetric high signal intensity of the affected side. • SyMRI-derived T2 relaxation time may be a promising imaging marker of the affected ear in patients with idiopathic SSNHL.


Asunto(s)
Pérdida Auditiva Sensorineural , Pérdida Auditiva Súbita , Cóclea/diagnóstico por imagen , Pérdida Auditiva Sensorineural/diagnóstico por imagen , Pérdida Auditiva Súbita/diagnóstico por imagen , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Estudios Retrospectivos
18.
Radiology ; 298(1): 114-122, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33141001

RESUMEN

Background Achieving high-spatial-resolution pituitary MRI is challenging because of the trade-off between image noise and spatial resolution. Deep learning-based MRI reconstruction enables image denoising with sharp edges and reduced artifacts, which improves the image quality of thin-slice MRI. Purpose To assess the diagnostic performance of 1-mm slice thickness MRI with deep learning-based reconstruction (DLR) (hereafter, 1-mm MRI+DLR) compared with 3-mm slice thickness MRI (hereafter, 3-mm MRI) for identifying residual tumor and cavernous sinus invasion in the evaluation of postoperative pituitary adenoma. Materials and Methods This single-institution retrospective study included 65 patients (mean age ± standard deviation, 54 years ± 10; 26 women) who underwent a combined imaging protocol including 3-mm MRI and 1-mm MRI+DLR for postoperative evaluation of pituitary adenoma between August and October 2019. Reference standards for correct diagnosis were established by using all available imaging resources, clinical histories, laboratory findings, surgical records, and pathology reports. The diagnostic performances of 3-mm MRI, 1-mm slice thickness MRI without DLR (hereafter, 1-mm MRI), and 1-mm MRI+DLR for identifying residual tumor and cavernous sinus invasion were evaluated by two readers and compared between the protocols. Results The performance of 1-mm MRI+DLR in the identification of residual tumor was comparable to that of 3-mm MRI (area under the receiver operating characteristic curve [AUC], 0.89-0.92 vs 0.85-0.89, respectively; P ≥ .09). In the identification of cavernous sinus invasion, the diagnostic performance of 1-mm MRI+DLR was higher than that of 3-mm MRI (AUC, 0.95-0.98 vs 0.83-0.87, respectively; P ≤ .02). Conventional 1-mm MRI (AUC, 0.82-0.83) showed comparable diagnostic performance to 3-mm MRI (AUC, 0.83-0.87) (P ≥ .38). With 1-mm MRI+DLR, residual tumor was diagnosed in 20 patients and cavernous sinus invasion was diagnosed in 14 patients, in whom these diagnoses were not made with 3-mm MRI. Conclusion In the postoperative evaluation of pituitary adenoma, 1-mm slice thickness MRI with deep learning-based reconstruction showed higher diagnostic performance than 3-mm slice thickness MRI in the identification of cavernous sinus invasion and comparable diagnostic performance to 3-mm slice thickness MRI in the identification of residual tumor. © RSNA, 2020 Online supplemental material is available for this article.


Asunto(s)
Adenoma/diagnóstico por imagen , Aprendizaje Profundo , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Neoplasias Hipofisarias/diagnóstico por imagen , Cuidados Posoperatorios/métodos , Adenoma/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Invasividad Neoplásica , Hipófisis/diagnóstico por imagen , Hipófisis/patología , Hipófisis/cirugía , Neoplasias Hipofisarias/patología
19.
Magn Reson Med ; 82(1): 237-250, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30883886

RESUMEN

PURPOSE: To propose a novel 3D ultrafast gradient echo-based MRI method, dubbed RASE, using quadratic-phase encoding. THEORY AND METHODS: Several characteristics of RASE, including spin behaviors, spatial resolution, SNR, and reduction of susceptibility-induced signal loss, were analytically described. A way of compensating for TE variation was suggested in the quadratic phase-encoding direction. Lemon, in vivo rat and mouse images were demonstrated at 9.4T, including a feasibility study for DCE-MRI as one of promising applications. RESULTS: RASE was successfully demonstrated by lemon and in vivo rat brain imaging, showing a good robustness to field inhomogeneity. Contribution of the quadratic phase to signal enhancement in a range of magnetic susceptibilities was also evaluated by simulation. Taking a geometric mean of 2 phantom data acquired with opposite gradient polarities effectively compensated for the effect of TE variation. Preliminary DCE-MRI results were also presented, showing that RASE could more accurately estimate Gd concentration than FLASH. CONCLUSION: RASE offers a shorter effective TE, having less sensitivity to field inhomogeneity and T2* effects, much less Nyquist ghosting or chemical-shift artifacts than gradient echo EPI (GE-EPI). We highly anticipate that RASE can be an alternative to GE-EPI in many applications, particularly those requiring high spatial and temporal resolutions in a broad volume coverage.


Asunto(s)
Imagen Eco-Planar/métodos , Imagenología Tridimensional/métodos , Animales , Encéfalo/diagnóstico por imagen , Masculino , Ratones , Ratones Endogámicos C57BL , Fantasmas de Imagen , Ratas
20.
Neuroimage ; 177: 30-44, 2018 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-29730495

RESUMEN

Mouse fMRI is critically useful to investigate functions of mouse models. Until now, the somatosensory-evoked responses in anesthetized mice are often widespread and inconsistent across reports. Here, we adopted a ketamine and xylazine mixture for mouse fMRI, which is relatively new anesthetics in fMRI experiments. Forepaw stimulation frequency was optimized using cerebral blood volume (CBV)-weighted optical imaging (n = 11) and blood-oxygenation-level dependent (BOLD) fMRI with a gradient-echo time of 16 ms at 9.4 T, and 4 Hz stimulation with 0.5 ms and 0.5 mA pulses induced the highest hemodynamic response. For 20-s 4-Hz unilateral forepaw stimulation, localized BOLD activity was consistently found in the contralateral primary forelimb somatosensory cortex (S1FL), while no significant change was observed in the ipsilateral S1FL. The mean magnitude was 1.44 ±â€¯0.20% SEM (n = 9) in the contralateral S1FL and 0.69 ±â€¯0.10% in the contralateral thalamus. The variability of evoked fMRI responses across sessions was investigated by comparing with resting state fMRI (rsfMRI) functional connectivity (FC). Evoked responses in S1FL were correlated positively with rsfMRI FC between bilateral S1FL (r = 0.63 to 0.69) and negatively with FC between S1FL and the anterior cingulate cortex (r = -0.50 to -0.57), suggesting that rsfMRI FC is a good index of the evoked fMRI response and anesthetized animal condition. Finally, three weekly fMRI scans were performed in 5 mice, and localized activity was reproducibly observed in S1FL, with a success rate of 70-95%. In summary, our developed fMRI protocol can be used for mapping functions of mouse models.


Asunto(s)
Anestésicos/administración & dosificación , Neuroimagen Funcional/métodos , Ketamina/administración & dosificación , Imagen por Resonancia Magnética/métodos , Corteza Somatosensorial/fisiología , Xilazina/administración & dosificación , Animales , Circulación Cerebrovascular/fisiología , Estimulación Eléctrica , Miembro Anterior/fisiología , Masculino , Ratones , Ratones Endogámicos C57BL , Modelos Animales , Imagen Óptica , Corteza Somatosensorial/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...