1.
Sci Rep ; 14(1): 5681, 2024 03 07.
Article En | MEDLINE | ID: mdl-38454102

From precordial ECG leads, the conventional determination of the negative derivative of the QRS complex (ND-ECG) assesses epicardial activation. Recently we showed that ultra-high-frequency electrocardiography (UHF-ECG) determines the activation of a larger volume of the ventricular wall. We aimed to combine these two methods to investigate the potential of volumetric and epicardial ventricular activation assessment and thereby determine the transmural activation sequence. We retrospectively analyzed 390 ECG records divided into three groups-healthy subjects with normal ECG, left bundle branch block (LBBB), and right bundle branch block (RBBB) patients. Then we created UHF-ECG and ND-ECG-derived depolarization maps and computed interventricular electrical dyssynchrony. Characteristic spatio-temporal differences were found between the volumetric UHF-ECG activation patterns and epicardial ND-ECG in the Normal, LBBB, and RBBB groups, despite the overall high correlations between both methods. Interventricular electrical dyssynchrony values assessed by the ND-ECG were consistently larger than values computed by the UHF-ECG method. Noninvasively obtained UHF-ECG and ND-ECG analyses describe different ventricular dyssynchrony and the general course of ventricular depolarization. Combining both methods based on standard 12-lead ECG electrode positions allows for a more detailed analysis of volumetric and epicardial ventricular electrical activation, including the assessment of the depolarization wave direction propagation in ventricles.


Electrocardiography , Heart Ventricles , Humans , Retrospective Studies , Electrocardiography/methods , Heart Ventricles/diagnostic imaging , Bundle-Branch Block/diagnosis , Arrhythmias, Cardiac
2.
Eur Heart J Suppl ; 25(Suppl E): E17-E24, 2023 Jun.
Article En | MEDLINE | ID: mdl-37234235

Biventricular pacing (Biv) and left bundle branch area pacing (LBBAP) are methods of cardiac resynchronization therapy (CRT). Currently, little is known about how they differ in terms of ventricular activation. This study compared ventricular activation patterns in left bundle branch block (LBBB) heart failure patients using an ultra-high-frequency electrocardiography (UHF-ECG). This was a retrospective analysis including 80 CRT patients from two centres. UHF-ECG data were obtained during LBBB, LBBAP, and Biv. Left bundle branch area pacing patients were divided into non-selective left bundle branch pacing (NSLBBP) or left ventricular septal pacing (LVSP) and into groups with V6 R-wave peak times (V6RWPT) < 90 ms and ≥ 90 ms. Calculated parameters were: e-DYS (time difference between the first and last activation in V1-V8 leads) and Vdmean (average of V1-V8 local depolarization durations). In LBBB patients (n = 80) indicated for CRT, spontaneous rhythms were compared with Biv (39) and LBBAP rhythms (64). Although both Biv and LBBAP significantly reduced QRS duration (QRSd) compared with LBBB (from 172 to 148 and 152 ms, respectively, both P < 0.001), the difference between them was not significant (P = 0.2). Left bundle branch area pacing led to shorter e-DYS (24 ms) than Biv (33 ms; P = 0.008) and shorter Vdmean (53 vs. 59 ms; P = 0.003). No differences in QRSd, e-DYS, or Vdmean were found between NSLBBP, LVSP, and LBBAP with paced V6RWPTs < 90 and ≥ 90 ms. Both Biv CRT and LBBAP significantly reduce ventricular dyssynchrony in CRT patients with LBBB. Left bundle branch area pacing is associated with more physiological ventricular activation.

3.
Front Cardiovasc Med ; 10: 1140988, 2023.
Article En | MEDLINE | ID: mdl-37034324

Background: Left bundle branch pacing (LBBP) produces delayed, unphysiological activation of the right ventricle. Using ultra-high-frequency electrocardiography (UHF-ECG), we explored how bipolar anodal septal pacing with direct LBB capture (aLBBP) affects the resultant ventricular depolarization pattern. Methods: In patients with bradycardia, His bundle pacing (HBP), unipolar nonselective LBBP (nsLBBP), aLBBP, and right ventricular septal pacing (RVSP) were performed. Timing of local ventricular activation, in leads V1-V8, was displayed using UHF-ECG, and electrical dyssynchrony (e-DYS) was calculated as the difference between the first and last activation. Durations of local depolarizations were determined as the width of the UHF-QRS complex at 50% of its amplitude. Results: aLBBP was feasible in 63 of 75 consecutive patients with successful nsLBBP. aLBBP significantly improved ventricular dyssynchrony (mean -9 ms; 95% CI (-12;-6) vs. -24 ms (-27;-21), ), p < 0.001) and shortened local depolarization durations in V1-V4 (mean differences -7 ms to -5 ms (-11;-1), p < 0.05) compared to nsLBBP. aLBBP resulted in e-DYS -9 ms (-12; -6) vs. e-DYS 10 ms (7;14), p < 0.001 during HBP. Local depolarization durations in V1-V2 during aLBBP were longer than HBP (differences 5-9 ms (1;14), p < 0.05, with local depolarization duration in V1 during aLBBP being the same as during RVSP (difference 2 ms (-2;6), p = 0.52). Conclusion: Although aLBBP improved ventricular synchrony and depolarization duration of the septum and RV compared to unipolar nsLBBP, the resultant ventricular depolarization was still less physiological than during HBP.

4.
Sensors (Basel) ; 22(5)2022 Mar 01.
Article En | MEDLINE | ID: mdl-35271057

Pulse wave velocity is a commonly used parameter for evaluating arterial stiffness and the overall condition of the cardiovascular system. The main goal of this study was to establish a methodology to test and validate multichannel bioimpedance as a suitable method for whole-body evaluations of pulse waves. We set the proximal location over the left carotid artery and eight distal locations on both the upper and lower limbs. In this way, it was possible to simultaneously evaluate pulse wave velocity (PWV) in the upper and lower limbs and in the limbs via four extra PWV measurements. Data were acquired from a statistical group of 220 healthy subjects who were divided into three age groups. The data were then analysed. We found a significant dependency of aortic PWV on age in those values measured using the left carotid as the proximal. PWV values in the upper and lower limbs were found to have no significant dependency on age. In addition, the PWV in the left femoral artery shows comparable values to published already carotid-femoral values. Those findings prove the reliability of whole-body multichannel bioimpedance for pulse wave velocity evaluation and provide reference values for whole-body PWV measurement.


Aging , Pulse Wave Analysis , Carotid Arteries , Humans , Lower Extremity , Pulse Wave Analysis/methods , Reproducibility of Results
5.
Clin Cardiol ; 45(4): 386-390, 2022 Apr.
Article En | MEDLINE | ID: mdl-35194820

BACKGROUND: Obstructive sleep apnea (OSA) imposes an afterload burden on the left ventricle and increases the pressure gradient across the aortic wall. Thus, OSA may increase the risk for aortic dissection (AD). METHODS: This study enrolled 40 subjects with acute AD from four institutions; 37 completed the modified Berlin Questionnaire and 31 underwent attended overnight polysomnography. Aortic diameter was measured on a computed tomography scan at seven locations from the sinotubular junction to the diaphragm. RESULTS: Twenty-seven subjects had type A dissection; 13 had type B. In those who had polysomnography apnea-hypopnea index (AHI) ranged from 0.7 to 89. Prevalence of OSA (AHI ≥ 5) was 61%. Nocturnal presentation (10 p.m.-7 a.m.) did not differ by presence/absence of OSA. The modified Berlin Questionnaire was not predictive of the presence of OSA. Among type A subjects with polysomnography (n = 23), aortic diameters at all locations were greater in the OSA group though differences were not statistically significant. Summating aortic diameters at the seven locations also yielded a numerically larger mean value in the OSA group versus the non-OSA group. CONCLUSIONS: In this sample of patients with acute dissection, OSA was prevalent but was not associated with a nocturnal presentation. The presence of underlying OSA may be associated with larger aortic diameters at the time of dissection compared to patients without OSA. Though differences did not meet statistical significance the current series is limited by small numbers.


Aortic Dissection , Sleep Apnea, Obstructive , Aortic Dissection/diagnosis , Aortic Dissection/epidemiology , Humans , Polysomnography , Prevalence , Sleep Apnea, Obstructive/complications , Sleep Apnea, Obstructive/diagnosis , Sleep Apnea, Obstructive/epidemiology , Surveys and Questionnaires
6.
Front Cardiovasc Med ; 8: 787414, 2021.
Article En | MEDLINE | ID: mdl-34950718

Background: Three different ventricular capture types are observed during left bundle branch pacing (LBBp). They are selective LBB pacing (sLBBp), non-selective LBB pacing (nsLBBp), and myocardial left septal pacing transiting from nsLBBp while decreasing the pacing output (LVSP). Study aimed to compare differences in ventricular depolarization between these captures using ultra-high-frequency electrocardiography (UHF-ECG). Methods: Using decremental pacing voltage output, we identified and studied nsLBBp, sLBBp, and LVSP in patients with bradycardia. Timing of ventricular activations in precordial leads was displayed using UHF-ECGs, and electrical dyssynchrony (e-DYS) was calculated as the difference between the first and last activation. The durations of local depolarizations (Vd) were determined as the width of the UHF-QRS complex at 50% of its amplitude. Results: In 57 consecutive patients, data were collected during nsLBBp (n = 57), LVSP (n = 34), and sLBBp (n = 23). Interventricular dyssynchrony (e-DYS) was significantly lower during LVSP -16 ms (-21; -11), than nsLBBp -24 ms (-28; -20) and sLBBp -31 ms (-36; -25). LVSP had the same V1d-V8d as nsLBBp and sLBBp except for V3d, which during LVSP was shorter than sLBBp; the mean difference -9 ms (-16; -1), p = 0.01. LVSP caused less interventricular dyssynchrony and the same or better local depolarization durations than nsLBBp and sLBBp irrespective of QRS morphology during spontaneous rhythm or paced QRS axis. Conclusions: In patients with bradycardia, LVSP in close proximity to LBB resulted in better interventricular synchrony than nsLBBp and sLBBp and did not significantly prolong depolarization of the left ventricular lateral wall.

7.
Sci Rep ; 11(1): 11469, 2021 06 01.
Article En | MEDLINE | ID: mdl-34075135

The study introduces and validates a novel high-frequency (100-400 Hz bandwidth, 2 kHz sampling frequency) electrocardiographic imaging (HFECGI) technique that measures intramural ventricular electrical activation. Ex-vivo experiments and clinical measurements were employed. Ex-vivo, two pig hearts were suspended in a human-torso shaped tank using surface tank electrodes, epicardial electrode sock, and plunge electrodes. We compared conventional epicardial electrocardiographic imaging (ECGI) with intramural activation by HFECGI and verified with sock and plunge electrodes. Clinical importance of HFECGI measurements was performed on 14 patients with variable conduction abnormalities. From 3 × 4 needle and 108 sock electrodes, 256 torso or 184 body surface electrodes records, transmural activation times, sock epicardial activation times, ECGI-derived activation times, and high-frequency activation times were computed. The ex-vivo transmural measurements showed that HFECGI measures intramural electrical activation, and ECGI-HFECGI activation times differences indicate endo-to-epi or epi-to-endo conduction direction. HFECGI-derived volumetric dyssynchrony was significantly lower than epicardial ECGI dyssynchrony. HFECGI dyssynchrony was able to distinguish between intraventricular conduction disturbance and bundle branch block patients.


Diagnostic Imaging , Electrocardiography , Heart Conduction System , Heart Ventricles , Animals , Heart Conduction System/diagnostic imaging , Heart Conduction System/physiopathology , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Humans , Swine
8.
Heart Rhythm ; 18(8): 1281-1289, 2021 08.
Article En | MEDLINE | ID: mdl-33930549

BACKGROUND: Nonselective His-bundle pacing (nsHBp), nonselective left bundle branch pacing (nsLBBp), and left ventricular septal myocardial pacing (LVSP) are recognized as physiological pacing techniques. OBJECTIVE: The purpose of this study was to compare differences in ventricular depolarization between these techniques using ultra-high-frequency electrocardiography (UHF-ECG). METHODS: In patients with bradycardia, nsHBp, nsLBBp (confirmed concomitant left bundle branch [LBB] and myocardial capture), and LVSP (pacing in left ventricular [LV] septal position without proven LBB capture) were performed. Timings of ventricular activations in precordial leads were displayed using UHF-ECG, and electrical dyssynchrony (e-DYS) was calculated as the difference between the first and last activation. Duration of local depolarization (Vd) was determined as width of the UHF-QRS complex at 50% of its amplitude. RESULTS: In 68 patients, data were collected during nsLBBp (35), LVSP (96), and nsHBp (55). nsLBBp resulted in larger e-DYS than did LVSP and nsHBp [- 24 ms (-28;-19) vs -12 ms (-16;-9) vs 10 ms (7;14), respectively; P <.001]. nsLBBp produced similar values of Vd in leads V5-V8 (36-43 ms vs 38-43 ms; P = NS in all leads) but longer Vd in leads V1-V4 (47-59 ms vs 41-44 ms; P <.05) as nsHBp. LVSP caused prolonged Vd in leads V1-V8 compared to nsHBp and longer Vd in leads V5-V8 compared to nsLBBp (44-51 ms vs 36-43 ms; P <.05) regardless of R-wave peak time in lead V5 or QRS morphology in lead V1 present during LVSP. CONCLUSION: nslbbp preserves physiological LV depolarization but increases interventricular electrical dyssynchrony. LV lateral wall depolarization during LVSP is prolonged, but interventricular synchrony is preserved.


Bundle of His/physiopathology , Bundle-Branch Block/therapy , Cardiac Pacing, Artificial/methods , Electrocardiography/methods , Heart Ventricles/physiopathology , Ventricular Function, Left/physiology , Ventricular Septum/physiopathology , Aged , Bundle-Branch Block/physiopathology , Female , Follow-Up Studies , Humans , Male , Prospective Studies
9.
J Cardiovasc Electrophysiol ; 32(5): 1385-1394, 2021 05.
Article En | MEDLINE | ID: mdl-33682277

BACKGROUND: Right ventricular (RV) pacing causes delayed activation of remote ventricular segments. We used the ultra-high-frequency ECG (UHF-ECG) to describe ventricular depolarization when pacing different RV locations. METHODS: In 51 patients, temporary pacing was performed at the RV septum (mSp); further subclassified as right ventricular inflow tract (RVIT) and right ventricular outflow tract (RVOT) for septal inflow and outflow positions (below or above the plane of His bundle in right anterior oblique), apex, anterior lateral wall, and at the basal RV septum with nonselective His bundle or RBB capture (nsHBorRBBp). The timings of UHF-ECG electrical activations were quantified as left ventricular lateral wall delay (LVLWd; V8 activation delay) and RV lateral wall delay (RVLWd; V1 activation delay). RESULTS: The LVLWd was shortest for nsHBorRBBp (11 ms [95% confidence interval = 5-17]), followed by the RVIT (19 ms [11-26]) and the RVOT (33 ms [27-40]; p < .01 between all of them), although the QRSd for the latter two were the same (153 ms (148-158) vs. 153 ms (148-158); p = .99). RV apical capture not only had a longer LVLWd (34 ms (26-43) compared to mSp (27 ms (20-34), p < .05), but its RVLWd (17 ms (9-25) was also the longest compared to other RV pacing sites (mean values for nsHBorRBBp, mSp, anterior and lateral wall captures being below 6 ms), p < .001 compared to each of them. CONCLUSION: RVIT pacing produces better ventricular synchrony compared to other RV pacing locations with myocardial capture. However, UHF-ECG ventricular dysynchrony seen during RVIT pacing is increased compared to concomitant capture of basal septal myocytes and His bundle or proximal right bundle branch.


Heart Ventricles , Ventricular Septum , Bundle of His , Cardiac Pacing, Artificial , Electrocardiography , Heart Ventricles/diagnostic imaging , Humans , Myocardial Contraction , Ventricular Septum/diagnostic imaging
10.
IEEE Trans Biomed Eng ; 67(10): 2721-2734, 2020 10.
Article En | MEDLINE | ID: mdl-31995473

OBJECTIVE: Nowadays, methods for ECG quality assessment are mostly designed to binary distinguish between good/bad quality of the whole signal. Such classification is not suitable to long-term data collected by wearable devices. In this paper, a novel approach to estimate long-term ECG signal quality is proposed. METHODS: The real-time quality estimation is performed in a local time window by calculation of continuous signal-to-noise ratio (SNR) curve. The layout of the data quality segments is determined by analysis of SNR waveform. It is distinguished between three levels of ECG signal quality: signal suitable for full wave ECG analysis, signal suitable only for QRS detection, and signal unsuitable for further processing. RESULTS: The SNR limits for reliable QRS detection and full ECG waveform analysis are 5 and 18 dB respectively. The method was developed and tested using synthetic data and validated on real data from wearable device. CONCLUSION: The proposed solution is a robust, accurate and computationally efficient algorithm for annotation of ECG signal quality that will facilitate the subsequent tailored analysis of ECG signals recorded in free-living conditions. SIGNIFICANCE: The field of long-term ECG signals self-monitoring by wearable devices is swiftly developing. The analysis of massive amount of collected data is time consuming. It is advantageous to characterize data quality in advance and thereby limit consequent analysis to useable signals.


Signal Processing, Computer-Assisted , Wearable Electronic Devices , Algorithms , Electrocardiography , Signal-To-Noise Ratio , Social Conditions
11.
Heart Rhythm ; 17(4): 607-614, 2020 04.
Article En | MEDLINE | ID: mdl-31805370

BACKGROUND: Right ventricular myocardial pacing leads to nonphysiological activation of heart ventricles. Contrary to this, His bundle pacing preserves their fast activation. Ultra-high-frequency electrocardiography (UHF-ECG) is a novel tool for ventricular depolarization assessment. OBJECTIVE: The purpose of this study was to describe UHF-ECG depolarization patterns during myocardial and His bundle pacing. METHODS: Forty-six patients undergoing His bundle pacing to treat bradycardia and spontaneous QRS complexes without bundle branch block were included. UHF-ECG recordings were performed during spontaneous rhythm, pure myocardial para-Hisian capture, and His bundle capture. QRS duration, QRS area, depolarization time in specific leads, and the UHF-ECG-derived ventricular dyssynchrony index were calculated. RESULTS: One hundred thirty-three UHF-ECG recordings were performed in 46 patients (44 spontaneous rhythm, 28 selective His bundle, 43 nonselective His bundle, and 18 myocardial capture). The mean QRS duration was 117 ms for spontaneous rhythm, 118 ms for selective, 135 ms for nonselective, and 166 ms for myocardial capture (P < .001 for nonselective and myocardial capture compared to each of the other types of ventricular activation). The calculated dyssynchrony index was shortest during spontaneous rhythm (12 ms; P = .02 compared to selective and P = .09 compared to nonselective), and it did not differ between selective and nonselective His bundle capture (16 vs 15 ms; P > .99) and was longest during myocardial capture of the para-Hisian area (37 ms; P < .001 compared to each of the other types of ventricular activation). CONCLUSION: In patients without bundle branch block, both types of His bundle, but not myocardial, capture preserve ventricular electrical synchrony as measured using UHF-ECG.


Bundle-Branch Block/therapy , Cardiac Pacing, Artificial/methods , Electrocardiography/methods , Heart Rate/physiology , Ventricular Function, Left/physiology , Ventricular Function, Right/physiology , Aged , Bundle of His/physiopathology , Bundle-Branch Block/physiopathology , Female , Heart Ventricles/physiopathology , Humans , Male
12.
J Cardiovasc Electrophysiol ; 31(1): 300-307, 2020 01.
Article En | MEDLINE | ID: mdl-31788894

INTRODUCTION: The present study introduces a new ultra-high-frequency 14-lead electrocardiogram technique (UHF-ECG) for mapping ventricular depolarization patterns and calculation of novel dyssynchrony parameters that may improve the selection of patients and application of cardiac resynchronization therapy (CRT). METHODS: Components of the ECG in sixteen frequency bands within the 150 to 1000 Hz range were used to create ventricular depolarization maps. The maximum time difference between the UHF QRS complex centers of mass of leads V1 to V8 was defined as ventricular electrical dyssynchrony (e-DYS), and the duration at 50% of peak voltage amplitude in each lead was defined as the duration of local depolarization (Vd). Proof of principle measurements was performed in seven patients with left (left bundle branch block) and four patients with right bundle branch block (right bundle branch block) before and during CRT using biventricular and His-bundle pacing. RESULTS: The acquired activation maps reflect the activation sequence under the tested conditions. e-DYS decreased considerably more than QRS duration, during both biventricular pacing (-50% vs -8%) and His-bundle pacing (-77% vs -13%). While biventricular pacing slightly increased Vd, His-bundle pacing reduced Vd significantly (+11% vs -36%), indicating the contribution of the fast conduction system. Optimization of biventricular pacing by adjusting VV-interval showed a decrease of e-DYS from 102 to 36 ms with only a small Vd increase and QRS duration decrease. CONCLUSIONS: The UHF-ECG technique provides novel information about electrical activation of the ventricles from a standard ECG electrode setup, potentially improving the selection of patients for CRT and application of CRT.


Bundle of His/physiopathology , Bundle-Branch Block/therapy , Cardiac Resynchronization Therapy , Electrocardiography , Heart Failure/therapy , Heart Rate , Action Potentials , Aged , Aged, 80 and over , Bundle-Branch Block/diagnosis , Bundle-Branch Block/physiopathology , Female , Heart Failure/diagnosis , Heart Failure/physiopathology , Humans , Male , Predictive Value of Tests , Proof of Concept Study , Time Factors , Treatment Outcome , Ventricular Function, Left , Ventricular Function, Right
13.
PLoS One ; 14(5): e0217097, 2019.
Article En | MEDLINE | ID: mdl-31150418

INTRODUCTION: Cardiac resynchronization therapy (CRT) is an effective treatment that reduces mortality and improves cardiac function in patients with left bundle branch block (LBBB). However, about 30% of patients passing the current criteria do not benefit or benefit only a little from CRT. Three predictors of benefit based on different ECG properties were compared: 1) "strict" left bundle branch block classification (SLBBB); 2) QRS area; 3) ventricular electrical delay (VED) which defines the septal-lateral conduction delay. These predictors have never been analyzed concurrently. We analyzed the relationship between them on a subset of 602 records from the MADIT-CRT trial. METHODS & RESULTS: SLBBB classification was performed by two experts; QRS area and VED were computed fully automatically. High-frequency QRS (HFQRS) maps were used to inspect conduction abnormalities. The correlation between SLBBB and other predictors was R = 0.613, 0.523 and 0.390 for VED, QRS area in Z lead, and QRS duration, respectively. Scatter plots were used to pick up disagreement between the predictors. The majority of SLBBB subjects- 295 of 330 (89%)-are supposed to respond positively to CRT according to the VED and QRS area, though 93 of 272 (34%) non-SLBBB should also benefit from CRT according to the VED and QRS area. CONCLUSION: SLBBB classification is limited by the proper setting of cut-off values. In addition, it is too "strict" and excludes patients that may benefit from CRT therapy. QRS area and VED are clearly defined parameters. They may be used to optimize biventricular stimulation. Detailed analysis of conduction irregularities with CRT optimization should be based on HFQRS maps.


Bundle-Branch Block/therapy , Cardiac Resynchronization Therapy Devices/standards , Cardiac Resynchronization Therapy/methods , Electrocardiography/methods , Electrocardiography/standards , Action Potentials , Bundle-Branch Block/physiopathology , Electric Countershock , Heart Rate , Humans , Predictive Value of Tests , Treatment Outcome , Ventricular Function, Left
14.
JACC Cardiovasc Imaging ; 12(12): 2475-2488, 2019 12.
Article En | MEDLINE | ID: mdl-30878439

OBJECTIVES: This study used optical coherence tomography to investigate the mechanism of false lumen (FL) formation in spontaneous coronary artery dissection (SCAD) by studying: 1) differences between fenestrated and nonfenestrated SCAD; 2) vasa vasorum density; and 3) light attenuation characteristics of the FL. BACKGROUND: SCAD is an increasingly recognized cause of acute coronary syndromes, characterized by FL formation and compression of the true lumen (TL). The mechanisms underlying FL formation remain poorly understood. METHODS: A total of 65 SCAD patients (68 vessels) who underwent acute OCT imaging as part of routine clinical care were included. Images were classified by the absence or presence of a connection (fenestration) between the TL and FL. Indexed measurements of TL stenosis, external elastic lamina (EEL) area, FL area, and light attenuation of the FL were assessed. Vasa vasorum densities of SCAD cases were compared with those in control non-SCAD myocardial infarction cases. RESULTS: In nonfenestrated cases, there was significantly larger expansion of the EEL area (9.1% vs. -1.9%; p <0.05) and a larger FL area (73.6% vs. 53.2%, respectively; p <0.05) in dissected segments. No significant differences were found between vasa vasorum density in SCAD and those in control subjects. The FL contents were heterogeneous but attenuated less light than whole blood or thrombus (4.28 ± 0.55 mm-1 vs. 5.08 ± 0.56 mm-1; p < 0.05; vs. 4.96 ± 0.56 mm-1; p < 0.05). CONCLUSIONS: These observational data suggest that the absence of a fenestration leads to increased FL pressure and compression of the TL. Although vasa vasorum may still be implicated in pathogenesis, increased vasa vasorum density could be an epiphenomenon of vascular healing.


Coronary Vessel Anomalies/diagnostic imaging , Coronary Vessels/diagnostic imaging , Tomography, Optical Coherence , Vasa Vasorum/diagnostic imaging , Vascular Diseases/congenital , Adult , Coronary Vessel Anomalies/physiopathology , Coronary Vessel Anomalies/therapy , Coronary Vessels/physiopathology , Europe , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prognosis , Registries , Retrospective Studies , Vasa Vasorum/physiopathology , Vascular Diseases/diagnostic imaging , Vascular Diseases/physiopathology , Vascular Diseases/therapy , Vascular Remodeling
15.
J Interv Card Electrophysiol ; 53(1): 105-113, 2018 Oct.
Article En | MEDLINE | ID: mdl-30008046

PURPOSE: To demonstrate the feasibility of directional percutaneous epicardial ablation using a partially insulated catheter. METHODS: Partially insulated catheter prototypes were tested in 12 (6 canine, 6 porcine) animal studies in two centers. Prototypes had interspersed windows to enable visualization of epicardial structures with ultrasound. Epicardial unipolar ablation and ablation between two electrodes was performed according to protocol (5-60 W power, 0-60 mls/min irrigation, 78 s mean duration). RESULTS: Of 96 epicardial ablation attempts, unipolar ablation was delivered in 53.1%. Electrogram evidence of ablation, when analyzable, occurred in 75 of 79 (94.9%) therapies. Paired pre/post-ablation pacing threshold (N = 74) showed significant increase in pacing threshold post-ablation (0.9 to 2.6 mA, P < .0001). Arrhythmias occurred in 18 (18.8%) therapies (11 ventricular fibrillation, 7 ventricular tachycardia), mainly in pigs (72.2%). Coronary artery visualization was variably successful. No phrenic nerve injury was noted during or after ablation. Furthermore, there were minimal pericardial changes with ablation. CONCLUSIONS: Epicardial ablation using a partially insulated catheter to confer epicardial directionality and protect the phrenic nerve seems feasible. Iterations with ultrasound windows may enable real-time epicardial surface visualization thus identifying coronary arteries at ablation sites. Further improvements, however, are necessary.


Catheter Ablation/instrumentation , Equipment Design , Intraoperative Complications/prevention & control , Phrenic Nerve/injuries , Tachycardia, Ventricular/surgery , Animals , Area Under Curve , Cardiac Catheters , Catheter Ablation/methods , Disease Models, Animal , Dogs , Feasibility Studies , Female , Random Allocation , Sensitivity and Specificity , Swine , Tachycardia, Ventricular/diagnostic imaging
16.
Circ Arrhythm Electrophysiol ; 11(5): e005719, 2018 05.
Article En | MEDLINE | ID: mdl-29700054

BACKGROUND: Although cardiac resynchronization therapy (CRT) is beneficial in heart failure patients with left bundle branch block, 30% of these patients do not respond to the therapy. Identifying these patients before implantation of the device is one of the current challenges in clinical cardiology. METHODS: We verified the diagnostic contribution and an optimized computerized approach to measuring ventricular electrical activation delay (VED) from body surface 12-lead ECGs. We applied the method to ECGs acquired before implantation (baseline) in the MADIT-CRT trial (Multicenter Automatic Defibrillator Implantation-Cardiac Resynchronization Therapy). VED values were dichotomized using its quartiles, and we tested the association of VED values with the MADIT-CRT primary end point of heart failure or death. Multivariate Cox proportional models were used to estimate the risk of study end points. In addition, the association between VED values and hemodynamic changes after CRT-D implantation was examined using 1-year follow-up echocardiograms. RESULTS: Our results showed that left bundle branch block patients with baseline VED <31.2 ms had a 35% risk of MADIT-CRT end points, whereas patients with VED ≥31.2 ms had a 14% risk (P<0.001). The hazard ratio for predicting primary end points in patients with low VED was 2.34 (95% confidence interval, 1.53-3.57; P<0.001). Higher VED values were also associated with beneficial hemodynamic changes. These strong VED associations were not found in the right bundle branch block and intraventricular conduction delay cohorts of the MADIT-CRT trial. CONCLUSIONS: Left bundle branch block patients with a high baseline VED value benefited most from CRT, whereas left bundle branch block patients with low VED did not show CRT benefits.


Action Potentials , Bundle-Branch Block/therapy , Cardiac Resynchronization Therapy , Defibrillators, Implantable , Electric Countershock/instrumentation , Electrocardiography , Heart Failure/therapy , Aged , Bundle-Branch Block/diagnosis , Bundle-Branch Block/mortality , Bundle-Branch Block/physiopathology , Cardiac Resynchronization Therapy/adverse effects , Cardiac Resynchronization Therapy/mortality , Clinical Decision-Making , Electric Countershock/adverse effects , Electric Countershock/mortality , Female , Heart Failure/diagnosis , Heart Failure/mortality , Heart Failure/physiopathology , Heart Rate , Humans , Male , Middle Aged , Multicenter Studies as Topic , Patient Selection , Predictive Value of Tests , Randomized Controlled Trials as Topic , Recovery of Function , Retrospective Studies , Time Factors , Treatment Outcome
17.
Annu Int Conf IEEE Eng Med Biol Soc ; 2017: 2598-2601, 2017 Jul.
Article En | MEDLINE | ID: mdl-29060431

Physiologic monitoring enables scientists and physicians to study both normal and pathologic signals of the body. While wearable technologies are available today, many of these technologies are limited to data collection only. Embedded processors have minimal computational capabilities. We propose an efficient implementation of the Stockwell Transform which can enable real-time time-frequency analysis of biological signals in a microcontroller. The method is built upon the fact that the Stockwell Transform can be implemented as a compact filter bank with pre-computed filter taps. Additionally, due to the long tails of the gaussian windowing function, low amplitude filter taps can be removed. The method was implemented on a TI MSP430 processor. Simulated ECG data was fed into the processor to demonstrate performance and evaluate computational efficiency.


Histological Techniques , Algorithms , Monitoring, Physiologic , Normal Distribution , Signal Processing, Computer-Assisted
18.
J Interv Card Electrophysiol ; 49(3): 245-254, 2017 Sep.
Article En | MEDLINE | ID: mdl-28695377

PURPOSE: The aim of this proof-of-concept study is to introduce new high-dynamic ECG technique with potential to detect temporal-spatial distribution of ventricular electrical depolarization and to assess the level of ventricular dyssynchrony. METHODS: 5-kHz 12-lead ECG data was collected. The amplitude envelopes of the QRS were computed in an ultra-high frequency band of 500-1000 Hz and were averaged (UHFQRS). UHFQRS V lead maps were compiled, and numerical descriptor identifying ventricular dyssynchrony (UHFDYS) was detected. RESULTS: An electrical UHFQRS maps describe the ventricular dyssynchrony distribution in resolution of milliseconds and correlate with strain rate results obtained by speckle tracking echocardiography. The effect of biventricular stimulation is demonstrated by the UHFQRS morphology and by the UHFDYS descriptor in selected examples. CONCLUSIONS: UHFQRS offers a new and simple technique for assessing electrical activation patterns in ventricular dyssynchrony with a temporal-spatial resolution that cannot be obtained by processing standard surface ECG. The main clinical potential of UHFQRS lies in the identification of differences in electrical activation among CRT candidates and detection of improvements in electrical synchrony in patients with biventricular pacing.


Cardiac Resynchronization Therapy/methods , Echocardiography, Three-Dimensional/methods , Electrocardiography/methods , Image Interpretation, Computer-Assisted , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/therapy , Adult , Aged , Female , Humans , Male , Middle Aged , Sampling Studies , Severity of Illness Index , Treatment Outcome , Ventricular Remodeling/physiology
19.
JACC Clin Electrophysiol ; 3(7): 747-755, 2017 07.
Article En | MEDLINE | ID: mdl-28736750

INTRODUCTION: Epicardial defibrillation systems currently require surgical access. We aimed to develop a percutaneous defibrillation system with partially-insulated epicardial coils to focus electrical energy on the myocardium and prevent or minimize extra-cardiac stimulation. METHODS: We tested 2 prototypes created for percutaneous introduction into the pericardial space via a steerable sheath. This included a partially-insulated defibrillation coil and a defibrillation mesh with a urethane balloon acting as an insulator to the face of the mesh not in contact with the epicardium. The average energy associated with a chance of successful defibrillation 75% of the time (ED75) was calculated for each experiment. RESULTS: Of 16 animal experiments, 3 pig experiments had malfunctioning mesh prototypes such that results were unreliable; these were excluded. Therefore, 13 animal experiments were analyzed - 6 canines (29.8±4.0kg); 7 pigs (41.1±4.4kg). The overall ED75 was 12.8±6.7J (10.9±9.1J for canines; 14.4±3.9J in pigs [P=0.37]). The lowest ED75 obtained in canines was 2.5J while in pigs it was 9.5J. The lowest energy resulting in successful defibrillation was 2J in canines and 5J in pigs. There was no evidence of coronary vessel injury or trauma to extra-pericardial structures. CONCLUSION: Percutaneous, epicardial defibrillation using a partially insulated coil is feasible and appears to be associated with low defibrillation thresholds. Focusing insulation may limit extra-cardiac stimulation and potentially lower energy requirements for efficient defibrillation.


Defibrillators , Animals , Dogs , Electric Countershock/instrumentation , Electric Countershock/methods , Female , Male , Pericardium , Swine
20.
J Card Fail ; 23(7): 558-562, 2017 Jul.
Article En | MEDLINE | ID: mdl-28408305

BACKGROUND: Patients with atrial fibrillation (AF) have an increased risk of diastolic dysfunction and heart failure. The purpose of this study was to identify independent predictors of early (ie, only exercise-induced) heart failure with preserved ejection fraction (HFpEF) and to describe the prevalence of early HFpEF among patients with paroxysmal AF. METHODS AND RESULTS: One hundred patients with paroxysmal AF and preserved left ventricular ejection fraction (LVEF) underwent catheterization for left atrial pressure (LAP) measurements at rest and at the peak of arm exercise (LAP-exe). Based on resting and exercise LAP values, the patients were divided into 3 groups. Sixty-one patients had no evidence of HFpEF (LAP at rest ≤15 mm Hg, LAP-exe <25 mm Hg). Twenty-five subjects had early HFpEF (LAP at rest ≤15 mm Hg, LAP-exe ≥25 mm Hg, prevalence 25%). Fourteen patients already had HFpEF at rest (LAP at rest >15 mm Hg). Multivariate exact logistic regression analysis identified age ≥58 years, LAP at rest ≥11 mm Hg, and peak systolic mitral annular velocity ≤9.3 cm/s to be independent predictors of early HFpEF. CONCLUSIONS: In patients with paroxysmal AF and preserved LVEF, there appears to be a clinically significant prevalence of early HFpEF.


Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/epidemiology , Heart Failure/diagnostic imaging , Heart Failure/epidemiology , Stroke Volume/physiology , Aged , Atrial Fibrillation/physiopathology , Cohort Studies , Early Diagnosis , Female , Heart Failure/physiopathology , Humans , Male , Middle Aged , Predictive Value of Tests , Prevalence , Prospective Studies
...