1.
Europace ; 2024 May 04.
Article En | MEDLINE | ID: mdl-38702961

BACKGROUND AND AIMS: Clinical concerns exist about the potential proarrhythmic effects of the sodium channel blockers flecainide and propafenone (SCB) in patients with cardiovascular disease. SCB were used to deliver early rhythm control (ERC) therapy in EAST-AFNET 4. METHODS: We analysed the primary safety outcome (death, stroke, or serious adverse events related to rhythm-control therapy) and primary efficacy outcome (cardiovascular death, stroke and hospitalization for worsening of heart failure or acute coronary syndrome) during SCB-intake for ERC patients (n = 1395) in EAST-AFNET 4. The protocol discouraged flecainide and propafenone in patients with reduced left ventricular ejection fraction and suggested stopping therapy upon QRS prolongation >25% on therapy. RESULTS: Flecainide or propafenone was given to 689 patients (age 69 (8) years; CHA2DS2-VASc 3.2 (1); 177 with heart failure; 41 with prior myocardial infarction, CABG or PCI; 26 with left ventricular hypertrophy >15 mm; median therapy duration 1,153 [237, 1,828] days). The primary efficacy outcome occurred less often in patients treated with SCB (3/100 (99/3,316) patient-years) than in patients who never received SCB (SCBnever 4.9/100 (150/3,083) patient-years, p < 0.001). There were numerically fewer primary safety outcomes in patients receiving SCB (2.9/100 (96/3,359) patient-years) than in SCBnever patients (4.2/100 (135/3,220) patient-years, adjusted p = 0.015). Sinus rhythm at 2 years was similar between groups (SCB 537/610 (88); SCBnever 472/579 (82)). CONCLUSION: Long-term therapy with flecainide or propafenone appeared to be safe in the EAST-AFNET 4 trial to deliver effective ERC therapy, including in selected patients with stable cardiovascular disease such as coronary artery disease and stable heart failure. CLINICAL TRIAL REGISTRATION: ISRCTN04708680, NCT01288352, EudraCT2010-021258-20, www.easttrial.org.

2.
JACC Clin Electrophysiol ; 10(5): 900-912, 2024 May.
Article En | MEDLINE | ID: mdl-38430087

BACKGROUND: Pulmonary vein isolation (PVI) alone is insufficient to treat many patients with persistent atrial fibrillation (PersAF). Adjunctive left atrial posterior wall (LAPW) ablation with thermal technologies has revealed lack of efficacy, perhaps limited by the difficulty in achieving lesion durability amid concerns of esophageal injury. OBJECTIVES: This study aims to compare the safety and effectiveness of PVI + LAPW ablation vs PVI in patients with PersAF using pulsed-field ablation (PFA). METHODS: In a retrospective analysis of the MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-approval Clinical Use of Pulsed Field Ablation) registry, we studied consecutive PersAF patients undergoing post-approval treatment with a pentaspline PFA catheter. The primary effectiveness outcome was freedom from any atrial arrhythmia of ≥30 seconds. Safety outcomes included the composite of acute and chronic major adverse events. RESULTS: Of the 547 patients with PersAF who underwent PFA, 131 (24%) received adjunctive LAPW ablation. Compared to PVI-alone, patients receiving adjunctive LAPW ablation were younger (65 vs 67 years of age, P = 0.08), had a lower CHA2DS2-VASc score (2.3 ± 1.6 vs 2.6 ± 1.6, P = 0.08), and were more likely to receive electroanatomical mapping (48.1% vs 39.0%, P = 0.07) and intracardiac echocardiography imaging (46.1% vs 17.1%, P < 0.001). The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmias was not statistically different between groups in the full (PVI + LAPW: 66.4%; 95% CI: 57.6%-74.4% vs PVI: 73.1%; 95% CI: 68.5%-77.2%; P = 0.68) and propensity-matched cohorts (PVI + LAPW: 71.7% vs PVI: 68.5%; P = 0.34). There was also no significant difference in major adverse events between the groups (2.2% vs 1.4%, respectively, P = 0.51). CONCLUSIONS: In patients with PersAF undergoing PFA, as compared to PVI-alone, adjunctive LAPW ablation did not improve freedom from atrial arrhythmia at 12 months.


Atrial Fibrillation , Catheter Ablation , Heart Atria , Pulmonary Veins , Humans , Atrial Fibrillation/surgery , Male , Female , Aged , Catheter Ablation/methods , Catheter Ablation/adverse effects , Middle Aged , Retrospective Studies , Heart Atria/surgery , Pulmonary Veins/surgery , Treatment Outcome , Registries
6.
Heart Rhythm ; 21(3): 250-257, 2024 Mar.
Article En | MEDLINE | ID: mdl-38036235

BACKGROUND: Pulsed-field ablation (PFA) is a nonthermal energy source for ablation of cardiac arrhythmias. This study investigated the prospective outcomes of a novel PFA generator in conjunction with a commercially available, contact force-sensing, focal ablation catheter. OBJECTIVE: The purpose of this study was to assess the feasibility, safety, and lesion characteristics of point-by-point PFA in consecutive patients undergoing repeat ablation of atrial fibrillation (AF). METHODS: The study involved reisolation of pulmonary veins (PVs) with electrical reconnection and the creation of an anterior line (AL) in patients with anterior substrate or durable pulmonary vein isolation (PVI). RESULTS: In 24 patients (46% female; mean age 67 ± 10 years; 67% persistent AF), successful reisolation of 27 of 27 reconnected PVs (100%) was performed. In 19 patients, AL ablation was performed, with bidirectional block in 16 (84%), median ablation time 26 [21, 33] minutes, and first-pass bidirectional block in 13 patients (68%). Acute AL reconduction occurred in 8 of 19 patients (42%). Among these 8 patients, a subsequent sustained block of the AL was achieved in 5 (63%). Ultra-high-density electroanatomic mapping revealed homogeneous but relatively large low-voltage areas in the ablated regions. Median procedural, left atrial dwell, and fluoroscopy times were 100 [90, 109] minutes, 83 [75, 98] minutes, and 10 [8, 13] minutes, respectively. No major or minor complications occurred. CONCLUSION: This study demonstrated feasibility, acute efficacy, and safety of point-by-point PFA for repeat PVI and AL ablation. Further studies are warranted to assess the long-term durability and comparison with established ablation methods.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Female , Middle Aged , Aged , Male , Pulmonary Veins/surgery , Prospective Studies , Treatment Outcome , Atrial Fibrillation/surgery , Heart Atria , Catheter Ablation/methods , Recurrence
7.
JAMA Cardiol ; 8(12): 1142-1151, 2023 12 01.
Article En | MEDLINE | ID: mdl-37910101

Importance: Previous studies evaluating the association of patient sex with clinical outcomes using conventional thermal ablative modalities for atrial fibrillation (AF) such as radiofrequency or cryoablation are controversial due to mixed results. Pulsed field ablation (PFA) is a novel AF ablation energy modality that has demonstrated preferential myocardial tissue ablation with a unique safety profile. Objective: To compare sex differences in patients undergoing PFA for AF in the Multinational Survey on the Methods, Efficacy, and Safety on the Postapproval Clinical Use of Pulsed Field Ablation (MANIFEST-PF) registry. Design, Setting, and Participants: This was a retrospective cohort study of MANIFEST-PF registry data, which included consecutive patients undergoing postregulatory approval treatment with PFA to treat AF between March 2021 and May 2022 with a median follow-up of 1 year. MANIFEST-PF is a multinational, retrospectively analyzed, prospectively enrolled patient-level registry including 24 European centers. The study included all consecutive registry patients (age ≥18 years) who underwent first-ever PFA for paroxysmal or persistent AF. Exposure: PFA was performed on patients with AF. All patients underwent pulmonary vein isolation and additional ablation, which was performed at the discretion of the operator. Main Outcomes and Measures: The primary effectiveness outcome was freedom from clinically documented atrial arrhythmia for 30 seconds or longer after a 3-month blanking period. The primary safety outcome was the composite of acute (<7 days postprocedure) and chronic (>7 days) major adverse events (MAEs). Results: Of 1568 patients (mean [SD] age, 64.5 [11.5] years; 1015 male [64.7%]) with AF who underwent PFA, female patients, as compared with male patients, were older (mean [SD] age, 68 [10] years vs 62 [12] years; P < .001), had more paroxysmal AF (70.2% [388 of 553] vs 62.4% [633 of 1015]; P = .002) but had fewer comorbidities such as coronary disease (9% [38 of 553] vs 15.9% [129 of 1015]; P < .001), heart failure (10.5% [58 of 553] vs 16.6% [168 of 1015]; P = .001), and sleep apnea (4.7% [18 of 553] vs 11.7% [84 of 1015]; P < .001). Pulmonary vein isolation was performed in 99.8% of female (552 of 553) and 98.9% of male (1004 of 1015; P = .90) patients. Additional ablation was performed in 22.4% of female (124 of 553) and 23.1% of male (235 of 1015; P = .79) patients. The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was similar in male and female patients (79.0%; 95% CI, 76.3%-81.5% vs 76.3%; 95% CI, 72.5%-79.8%; P = .28). There was also no significant difference in acute major AEs between groups (male, 1.5% [16 of 1015] vs female, 2.5% [14 of 553]; P = .19). Conclusion and Relevance: Results of this cohort study suggest that after PFA for AF, there were no significant sex differences in clinical effectiveness or safety events.


Atrial Fibrillation , Humans , Male , Female , Middle Aged , Aged , Adolescent , Atrial Fibrillation/drug therapy , Retrospective Studies , Cohort Studies , Sex Factors , Treatment Outcome
8.
Clin Cardiol ; 46(10): 1210-1219, 2023 Oct.
Article En | MEDLINE | ID: mdl-37526378

BACKGROUND: Although electrophysiological (EP) centers have institutional standards, evidence on management of cardiac tamponade is lacking. AIM AND METHODS: A physician-based survey was conducted by sending out questionnaires to all hospitals in Germany performing EP procedures. To evaluate the infrastructure of EP centers and the impact of center volume and onsite cardiac surgery on the management of cardiac tamponade, the results of the survey were analyzed for low-volume (0-250 procedures per year), mid-volume (250-500 procedures), and high-volume (>500 procedures) centers, as well as for centers with and without onsite cardiac surgery. RESULTS: A total of 341 centers were identified and 189/341 (55%) returned data sets were analyzed. Most types of EP procedures are performed across all kinds of centers. Ablation of ventricular tachycardia (VT) is concentrated in higher volume centers and in centers with onsite cardiac surgery. None of the participating low-volume centers and only 13% of centers without onsite cardiac surgery responded to performing epicardial VT ablation. Irrespective of center volume and onsite cardiac surgery, neither body mass index nor age was reported to be an exclusion criterion for ablation procedures. Higher volume centers and centers with onsite cardiac surgery more often have dedicated EP laboratories and EP-nursing teams. Also, differences regarding periprocedural safety precautions and management of cardiac tamponade were found for low-, mid-, and high-volume centers, as well as for centers with and without onsite cardiac surgery. CONCLUSION: While center volume and onsite cardiac surgery do not impact patient selection, there are differences in ablation spectrum, infrastructure, periprocedural safety precautions, and treatment of tamponade.


Cardiac Tamponade , Catheter Ablation , Tachycardia, Ventricular , Humans , Cardiac Tamponade/etiology , Cardiac Tamponade/surgery , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/therapy , Tachycardia, Ventricular/surgery , Germany/epidemiology , Catheter Ablation/methods , Electrophysiology , Treatment Outcome
10.
J Cardiovasc Electrophysiol ; 34(9): 1802-1807, 2023 09.
Article En | MEDLINE | ID: mdl-37473404

INTRODUCTION: Pulsed-field ablation (PFA) and the multielectrode radiofrequency balloon (RFB) are two novel ablation technologies to perform pulmonary vein isolation (PVI). It is currently unknown whether these technologies differ in lesion formation and lesion extent. We compared the acute lesion extent after PVI induced by PFA and RFB by measuring low-voltage area in high-density maps and the release of biomolecules reflecting cardiac injury. METHODS: PVI was performed with a pentaspline catheter (FARAPULSE) applying PFA or with the compliant multielectrode RFB (HELIOSTAR). Before and after PVI high-density mapping with CARTO 3 was performed. In addition, blood samples were taken before transseptal puncture and after post-PVI remapping and serum concentrations of high-sensitive Troponin I were quantified by immunoassay. RESULTS: Sixty patients undergoing PVI by PFA (n = 28, age 69 ± 12 year, 60% males, 39.3% persistent atrial fibrillation [AF]) or RFB (n = 32, age 65 ± 13 year, 53% males, 21.9% persistent AF) were evaluated. Acute PVI was achieved in all patients in both groups. Mean number of PFA pulses was 34.2 ± 4.5 and mean number RFB applications was 8.5 ± 3 per patient. Total posterior ablation area was significantly larger in PFA (20.7 ± 7.7 cm²) than in RFB (7.1 ± 2.09 cm²; p < .001). Accordingly, posterior ablation area for each PV resulted in larger lesions after PFA versus RFB (LSPV 5.2 ± 2.7 vs. 1.9 ± 0.8 cm², LIPV 5.5 ± 2.3 vs. 1.9 ± 0.8 cm², RSPV 4.7 ± 1.9 vs. 1.6 ± 0.5 cm², RIPV 5.3 ± 2.1 vs. 1.6 ± 0.7 cm,² respectively; p < .001). In a subset of 38 patients, increase of hsTropI was higher after PFA (625 ± 138 pg/mL, n = 28) versus RFB (148 ± 36 pg/mL, n = 10; p = .049) supporting the evidence of larger lesion extent by PFA. CONCLUSION: PFA delivers larger acute lesion areas and higher troponin release upon successful PVI than multielectrode RFB-based PVI in this single-center series.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Male , Humans , Middle Aged , Aged , Aged, 80 and over , Female , Pulmonary Veins/surgery , Treatment Outcome , Catheter Ablation/adverse effects , Catheter Ablation/methods , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheters
11.
Circulation ; 148(1): 35-46, 2023 07 04.
Article En | MEDLINE | ID: mdl-37199171

BACKGROUND: Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (<7 days postprocedure) and latent (>7 days) major adverse events. RESULTS: At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA2DS2-VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289-421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%-80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P=0.001). Acute major adverse events occurred in 1.9% of patients. CONCLUSIONS: In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.


Atrial Fibrillation , Atrial Flutter , Catheter Ablation , Pulmonary Veins , Humans , Female , Middle Aged , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/drug therapy , Retrospective Studies , Stroke Volume , Ventricular Function, Left , Treatment Outcome , Atrial Flutter/etiology , Registries , Catheter Ablation/adverse effects , Catheter Ablation/methods , Recurrence
12.
Front Cardiovasc Med ; 10: 1156500, 2023.
Article En | MEDLINE | ID: mdl-37034336

Background: Cryoballoon (CB)- based pulmonary vein isolation (PVI) remains guided by fluoroscopy and dye. The novel saline injection-based occlusion tool allows for pulmonary vein (PV)-occlusion assessment without the need for dye injection. Aim: To compare KODEX-EPD guided CB-PVI using the novel saline injection-based workflow with conventional cryoablation for acute efficacy, fluoroscopy exposure and dye volume. Methods: Consecutive atrial fibrillation (AF)- patients undergoing CB-PVI in conjunction with KODEX-EPD (CryoEPD group) were analyzed. Patients undergoing conventional CB-PVI (Cryo group) in the same time period acted as controls. Results: One hundred forty patients [91/140 (65%) persistent AF] were studied. Seventy patients underwent CryoEPD procedures [64 ± 13 years, 21 (30%) female] and seventy patients underwent Cryo procedures [68 ± 10 years, 27 (39%) female].A total of 560 PVs were identified and successfully isolated. Mean procedure time was 66 ± 15 min for the CryoEPD group, and 65 ± 19 min for the Cryo group (p = 0.3). Fluoroscopy time (CryoEPD 6 ± 4 min; Cryo 13 ± 6 min, p < 0.001) and dose area product (CryoEPD 193 [111; 297] cGycm2; Cryo 381 [268; 614] cGycm2, p < 0.001) were lower in patients undergoing CryoEPD compared with Cryo procedures. No dye was needed in the CryoEPD group while 53 ± 18 ml dye per patient were administered for the Cryo group (p < 0.001). The overall complication rate was comparable between both groups (p = 0.5). Conclusion: KODEX-EPD guided AF-ablation enables dye-free CB-based PVI with reduced fluoroscopy exposure when compared to conventional CB-ablation, without differences in acute procedural outcomes or procedure duration.

14.
Circ Arrhythm Electrophysiol ; 16(3): e011602, 2023 03.
Article En | MEDLINE | ID: mdl-36763906

BACKGROUND: Electrical remodeling in human persistent atrial fibrillation is believed to result from rapid electrical activation of the atria, but underlying genetic causes may contribute. Indeed, common gene variants in an enhancer region close to PITX2 (paired-like homeodomain transcription factor 2) are strongly associated with atrial fibrillation, but the mechanism behind this association remains unknown. This study evaluated the consequences of PITX2 deletion (PITX2-/-) in human induced pluripotent stem cell-derived atrial cardiomyocytes. METHODS: CRISPR/Cas9 (clustered regularly interspaced short palindromic repeats/clustered regularly interspaced short palindromic repeat-associated 9) was used to delete PITX2 in a healthy human iPSC line that served as isogenic control. Human induced pluripotent stem cell-derived atrial cardiomyocytes were differentiated with unfiltered retinoic acid and cultured in atrial engineered heart tissue. Force and action potential were measured in atrial engineered heart tissues. Single human induced pluripotent stem cell-derived atrial cardiomyocytes were isolated from atrial engineered heart tissue for ion current measurements. RESULTS: PITX2-/- atrial engineered heart tissue beats slightly slower than isogenic control without irregularity. Force was lower in PITX2-/- than in isogenic control (0.053±0.015 versus 0.131±0.017 mN, n=28/3 versus n=28/4, PITX2-/- versus isogenic control; P<0.0001), accompanied by lower expression of CACNA1C and lower L-type Ca2+ current density. Early repolarization was weaker (action potential duration at 20% repolarization; 45.5±13.2 versus 8.6±5.3 ms, n=18/3 versus n=12/4, PITX2-/- versus isogenic control; P<0.0001), and maximum diastolic potential was more negative (-78.3±3.1 versus -69.7±0.6 mV, n=18/3 versus n=12/4, PITX2-/- versus isogenic control; P=0.001), despite normal inward rectifier currents (both IK1 and IK,ACh) and carbachol-induced shortening of action potential duration. CONCLUSIONS: Complete PITX2 deficiency in human induced pluripotent stem cell-derived atrial cardiomyocytes recapitulates some findings of electrical remodeling of atrial fibrillation in the absence of fast beating, indicating that these abnormalities could be primary consequences of lower PITX2 levels.


Atrial Fibrillation , Atrial Remodeling , Induced Pluripotent Stem Cells , Humans , Induced Pluripotent Stem Cells/metabolism , Heart Atria , Action Potentials , Myocytes, Cardiac/metabolism
15.
Europace ; 25(2): 688-697, 2023 02 16.
Article En | MEDLINE | ID: mdl-35989424

AIMS: Cardiac arrhythmia originating from the papillary muscle (PM) can trigger ventricular fibrillation (VF) and cause sudden cardiac death even in the absence of structural heart disease. Most premature ventricular contractions, however, are benign and hitherto difficult to distinguish from a potentially fatal arrhythmia. Altered repolarization characteristics are associated with electrical instability, but electrophysiological changes which precede degeneration into VF are still not fully understood. METHODS AND RESULTS: Ventricular arrhythmia (VA) was induced by aconitine injection into PMs of healthy sheep. To investigate mechanisms of degeneration of stable VA into VF in structurally healthy hearts, endocardial high-density and epicardial mapping was performed during sinus rhythm (SR) and VA. The electrical restitution curve, modelling the relation of diastolic interval and activation recovery interval (a surrogate parameter for action potential duration), is steeper in VA than in non-arrhythmia (ventricular pacing and SR). Steeper restitution curves reflect electrical instability and propensity to degenerate into VF. Importantly, we find the parameter repolarization time in relation to cycle length (RT/CL) to differentiate self-limiting from degenerating arrhythmia with high specificity and sensitivity. CONCLUSION: RT/CL may serve as a simple index to aid differentiation between self-limiting and electrically instable arrhythmia with the propensity to degenerate to VF. RT/CL is independent of cycle length and could easily be measured to identify electrical instability in patients.


Arrhythmias, Cardiac , Papillary Muscles , Animals , Sheep , Ventricular Fibrillation/diagnosis , Ventricular Fibrillation/etiology , Heart Ventricles , Action Potentials/physiology , Electrocardiography
16.
Clin Res Cardiol ; 112(12): 1727-1737, 2023 Dec.
Article En | MEDLINE | ID: mdl-35713695

BACKGROUND: Despite continued efforts to improve the safety of catheter ablation, pericardial tamponade remains one of its more frequent, potentially life-threatening complications. Management of cardiac tamponade is not standardized and uncertainties regarding acute treatment remain. METHODS: This survey sought to evaluate the management of cardiac tamponade in German EP centers via a standardized postal questionnaire. All 341 identified German EP centers were invited to return a questionnaire on their standards for the management of cardiac tamponade. RESULTS: A total of 189 German EP centers completed the questionnaire. Several precautions are followed to avoid pericardial tamponade: A minority of centers preclude very old patients (19%) or those with a high body mass index (30%) from ablation. Non-vitamin K antagonist oral anticoagulants are briefly paused in most centers (88%) before procedures, while vitamin K antagonists are continued. Pericardial tamponade is usually treated using reversal of heparin by applying protamine (86%) and pericardiocentesis under both, fluoroscopic and echocardiographic guidance (62%). A pigtail catheter is mostly inserted (97%) and autotransfusion of aspirated blood is performed in 47% of centers. The decision for surgical repair depends on different clinical and infrastructural aspects. The timing of reinitiation of anticoagulation widely differs between the centers. Approximately 1/3 of centers prescribe nonsteroidal anti-inflammatory agents, colchicine or steroids after pericardiocentesis. CONCLUSION: The present survey shows that the management of cardiac tamponade is still inhomogeneous in German ablation centers. However, multiple findings of this survey can be generalized and might guide especially less experienced operators and centers in their treatment and decision strategies.


Cardiac Tamponade , Humans , Cardiac Tamponade/diagnosis , Cardiac Tamponade/etiology , Cardiac Tamponade/therapy , Pericardiocentesis/adverse effects , Pericardiocentesis/methods , Anticoagulants/therapeutic use , Heparin , Cardiac Electrophysiology
18.
Clin Res Cardiol ; 112(6): 795-806, 2023 Jun.
Article En | MEDLINE | ID: mdl-36131138

PURPOSE: Pulsed-field ablation (PFA) is a new energy source to achieve pulmonary vein isolation (PVI) by targeted electroporation of cardiomyocytes. Experimental and controlled clinical trial data suggest good efficacy of PFA-based PVI. We aimed to assess efficacy, safety and follow-up of PFA-based PVI in an early adopter routine care setting. METHODS: Consecutive patients with symptomatic paroxysmal or persistent atrial fibrillation (AF) underwent PVI using the Farawave® PFA ablation catheter in conjunction with three-dimensional mapping at two German high-volume ablation centers. PVI was achieved by applying 8 PFA applications in each PV. RESULTS: A total of 138 patients undergoing a first PVI (67 ± 12 years, 66% male, 62% persistent AF) were treated. PVI was achieved in all patients by deploying 4563 applications in 546 PVs (8.4 ± 1.0/PV). Disappearance of PV signals after the first application was demonstrated in 544/546 PVs (99.6%). More than eight PFA applications were performed in 29/546 PVs (6%) following adapted catheter positioning or due to reconnection as assessed during remapping. Mean procedure time was 78 ± 22 min including pre- and post PVI high-density voltage mapping. PFA catheter LA dwell-time was 23 ± 9 min. Total fluoroscopy time and dose area product were 16 ± 7 min and 505 [275;747] cGy*cm2. One pericardial tamponade (0.7%), one transient ST-elevation (0.7%) and three groin complications (2.2%) occurred. 1-year follow-up showed freedom of arrhythmia in 90% in patients with paroxysmal AF (n = 47) and 60% in patients with persistent AF (n = 82, p = 0.015). CONCLUSIONS: PFA-based PVI is acutely highly effective and associated with a beneficial safety and low recurrence rate.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Male , Female , Follow-Up Studies , Pulmonary Veins/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Fluoroscopy , Treatment Outcome , Recurrence
19.
Cells ; 11(17)2022 09 02.
Article En | MEDLINE | ID: mdl-36078153

Genetic variants in α-actinin-2 (ACTN2) are associated with several forms of (cardio)myopathy. We previously reported a heterozygous missense (c.740C>T) ACTN2 gene variant, associated with hypertrophic cardiomyopathy, and characterized by an electro-mechanical phenotype in human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs). Here, we created with CRISPR/Cas9 genetic tools two heterozygous functional knock-out hiPSC lines with a second wild-type (ACTN2wt) and missense ACTN2 (ACTN2mut) allele, respectively. We evaluated their impact on cardiomyocyte structure and function, using a combination of different technologies, including immunofluorescence and live cell imaging, RNA-seq, and mass spectrometry. This study showed that ACTN2mut presents a higher percentage of multinucleation, protein aggregation, hypertrophy, myofibrillar disarray, and activation of both the ubiquitin-proteasome system and the autophagy-lysosomal pathway as compared to ACTN2wt in 2D-cultured hiPSC-CMs. Furthermore, the expression of ACTN2mut was associated with a marked reduction of sarcomere-associated protein levels in 2D-cultured hiPSC-CMs and force impairment in engineered heart tissues. In conclusion, our study highlights the activation of proteolytic systems in ACTN2mut hiPSC-CMs likely to cope with ACTN2 aggregation and therefore directs towards proteopathy as an additional cellular pathology caused by this ACTN2 variant, which may contribute to human ACTN2-associated cardiomyopathies.


Actinin , Cardiomyopathy, Hypertrophic , Protein Aggregation, Pathological , Actinin/genetics , Actinin/metabolism , Cardiomyopathy, Hypertrophic/genetics , Cardiomyopathy, Hypertrophic/metabolism , Humans , Induced Pluripotent Stem Cells/metabolism , Myocytes, Cardiac/metabolism , Protein Aggregation, Pathological/genetics , Protein Aggregation, Pathological/metabolism , Sarcomeres/metabolism
...