1.
J Clin Monit Comput ; 30(6): 985-994, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26563187

RESUMEN

Increased extravascular lung water (EVLW) may contribute to respiratory failure in neonates. Accurate measurement of EVLW in these patients is limited due to the lack of bedside methods. The aim of this pilot study was to investigate the reliability of the transpulmonary ultrasound dilution (TPUD) technique as a possible method for estimating EVLW in a neonatal animal model. Pulmonary edema was induced in 11 lambs by repeated surfactant lavages. In between the lavages, EVLW indexed by bodyweight was estimated by TPUD (EVLWItpud) and transpulmonary dye dilution (EVLWItpdd) (n = 22). Final EVLWItpud measurements were also compared with EVLWI estimations by gold standard post mortem gravimetry (EVLWIgrav) (n = 6). EVLWI was also measured in two additional lambs without pulmonary edema. Bland-Altman plots showed a mean bias between EVLWItpud and EVLWItpdd of -3.4 mL/kg (LOA ± 25.8 mL/kg) and between EVLWItpud and EVLWIgrav of 1.7 mL/kg (LOA ± 8.3 mL/kg). The percentage errors were 109 and 43 % respectively. The correlation between changes in EVLW measured by TPUD and TPDD was r2 = 0.22. Agreement between EVLWI measurements by TPUD and TPDD was low. Trending ability to detect changes between these two methods in EVLWI was questionable. The accuracy of EVLWItpud was good compared to the gold standard gravimetric method but the TPUD lacked precision in its current prototype. Based on these limited data, we believe that TPUD has potential for future use to estimate EVLW after adaptation of the algorithm. Larger studies are needed to support our findings.


Asunto(s)
Agua Pulmonar Extravascular , Termodilución/métodos , Algoritmos , Animales , Gasto Cardíaco , Cateterismo , Arteria Femoral/patología , Hemodinámica , Lesión Pulmonar/patología , Edema Pulmonar/terapia , Reproducibilidad de los Resultados , Ovinos , Termogravimetría , Ultrasonografía
2.
Acta Anaesthesiol Scand ; 59(10): 1319-29, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26079640

RESUMEN

BACKGROUND: Human factors account for the majority of adverse events in both aviation and medicine. Human factors awareness training entitled "Crew Resource Management (CRM)" is associated with improved aviation safety. We determined whether implementation of CRM impacts outcome in critically ill patients. METHODS: We performed a prospective 3-year cohort study in a 32-bed ICU, admitting 2500-3000 patients yearly. At the end of the baseline year, all personnel received CRM training, followed by 1 year of implementation. The third year was defined as the clinical effect year. All 7271 patients admitted to the ICU in the study period were included. The primary outcome measure was ICU complication rate. Secondary outcome measures were ICU and hospital length of stay, and standardized mortality ratio. RESULTS: Occurrence of serious complications was 67.1/1000 patients and 66.4/1000 patients during the baseline and implementation year respectively, decreasing to 50.9/1000 patients in the post-implementation year (P = 0.03). Adjusted odds ratios for occurrence of complications were 0.92 (95% CI 0.71-1.19, P = 0.52) and 0.66 (95% CI 0.51-0.87, P = 0.003) in the implementation and post-implementation year. The incidence of cardiac arrests was 9.2/1000 patients and 8.3/1000 patients during the baseline and implementation year, decreasing to 3.5/1000 patients (P = 0.04) in the post-implementation year, while cardiopulmonary resuscitation success rate increased from 19% to 55% and 67% (P = 0.02). Standardized mortality ratio decreased from 0.72 (95% CI 0.63-0.81) in the baseline year to 0.60 (95% CI 0.53-0.67) in the post-implementation year (P = 0.04). CONCLUSION: Our data indicate an association between CRM implementation and reduction in serious complications and lower mortality in critically ill patients.


Asunto(s)
Capacitación en Servicio/organización & administración , Unidades de Cuidados Intensivos , Grupo de Atención al Paciente/organización & administración , Anciano , Estudios de Cohortes , Femenino , Paro Cardíaco/epidemiología , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud , Estudios Prospectivos
5.
Br J Anaesth ; 111(6): 967-70, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23884875

RESUMEN

BACKGROUND: Asthma is a common disease in children and often develops early in life. This multicentre retrospective case series describe the use and effectiveness of sevoflurane inhalation therapy in a series of children with severe asthma in the paediatric intensive care unit (PICU). METHODS: Seven children ranging from 4 to 13 yr of age admitted to the PICU of two tertiary care hospitals in the Netherlands were included. They all were admitted with the diagnosis of severe asthma requiring invasive mechanical ventilation and were treated with sevoflurane inhalation therapy. RESULTS: The median (range) Pco2 level at the start, after 2 h, and at the end of sevoflurane treatment were 14 (5.1-24.8), 9.8 (5.4-17.0), and 6.2 (4.5-11.4) kPa (P=0.05) while the median (range) pH was 7.02 (6.97-7.36), 7.18 (7.04-7.35), and 7.43 (7.15-7.47) kPa (P=0.01), respectively. The median (range) peak pressure values declined from 30 (23-56) to 20.4 (14-33) cm H2O (P=0.03). No severe adverse effects besides hypotension, with sufficient response to norepinephrine treatment, were seen. CONCLUSIONS: Sevoflurane inhalation corrects high levels of Pco2 and provides clinical improvement in mechanically ventilated children with life-threatening asthma who fail to respond to conventional treatment.


Asunto(s)
Anestésicos por Inhalación/uso terapéutico , Asma/tratamiento farmacológico , Éteres Metílicos/uso terapéutico , Adolescente , Asma/sangre , Dióxido de Carbono/sangre , Niño , Preescolar , Cuidados Críticos/métodos , Evaluación de Medicamentos/métodos , Humanos , Concentración de Iones de Hidrógeno , Presión Parcial , Terapia Respiratoria/métodos , Estudios Retrospectivos , Sevoflurano , Resultado del Tratamiento
7.
Br J Anaesth ; 111(2): 286-92, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23423726

RESUMEN

BACKGROUND: The transpulmonary thermodilution (TPTD) technique is widely used in clinical practice for measuring cardiac output (CO). This study was designed to investigate the influence of various levels of pulmonary oedema on the reliability of CO measurements by the TPTD method. METHODS: In 11 newborn lambs pulmonary oedema was induced using a surfactant washout technique. Serial CO measurements using TPTD (CO(TPTD)) were performed at various amounts of lung water. Simultaneously, CO was measured by an ultrasound flow probe around the main pulmonary artery (CO(MPA)) and used as the standard reference. CO was divided by the body surface area to calculate cardiac index (CI). Data were analysed using correlational statistics and Bland-Altman analysis. RESULTS: One lamb died prematurely. A total of 56 measurements in 10 lambs were analysed with a median CI(MPA) of 2.95 (IQR 1.04) litre min(-1) m(-2). Mean percentage increase in extravascular lung water (EVLW) between the start and the end of the study was 126.4% (SD 40.4). Comparison of the two CO methods showed a mean bias CI of -0.16 litre min(-1) m(-2) (limits of agreement ±0.73 litre min(-1) m(-2)) and a percentage error of 23.8%. Intraclass correlation coefficients were 0.91 (95% CI 0.81-0.95) for absolute agreement and 0.92 (95% CI 0.87-0.95) for consistency. Acceptable agreement was confirmed by a tolerability-agreement ratio of 0.39. The within-subject correlation between the amount of EVLWI and the bias between the two methods was not significant (-0.02; P=0.91). CONCLUSIONS: CO measurements by the transpulmonary thermodilution technique over a wide range of CI values are not affected by the presence of high EVLWI. The slight underestimation of the CO is independent of the amount of pulmonary oedema.


Asunto(s)
Gasto Cardíaco/fisiología , Edema Pulmonar/fisiopatología , Animales , Animales Recién Nacidos , Agua Pulmonar Extravascular/fisiología , Reproducibilidad de los Resultados , Oveja Doméstica , Termodilución/métodos
8.
Br J Anaesth ; 108(3): 395-401, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22185905

RESUMEN

BACKGROUND: Dynamic indices, including pulse pressure, systolic pressure, and stroke volume variation (PPV, SPV, and SVV), are accurate predictors of fluid responsiveness under strict conditions, for example, controlled mechanical ventilation using conventional tidal volumes (TVs) in the absence of cardiac arrhythmias. However, in routine clinical practice, these prerequisites are not always met. We evaluated the effect of regularly used ventilator settings, different calculation methods, and the presence of cardiac arrhythmias on the ability of dynamic indices to predict fluid responsiveness in sedated, mechanically ventilated patients. METHODS: We prospectively evaluated 47 fluid challenges in 29 consecutive cardiac surgery patients. Patients were divided into different groups based on TV. Dynamic indices were calculated in various ways: calculation over 30 s, breath-by-breath (with and without excluding arrhythmias), and with correction for TV. RESULTS: The predictive value was optimal in the group ventilated with TVs >7 ml kg(-1) with correction for TV, calculated breath-by-breath, and with exclusion of arrhythmias [area under the curve (AUC)=0.95, 0.93, and 0.90 for PPV, SPV, and SVV, respectively]. Including patients ventilated with lower TVs decreased the predictive value of all dynamic indices, while calculating dynamic indices over 30 s and not excluding cardiac arrhythmias further reduced the AUC to 0.51, 0.63, and 0.51 for PPV, SPV, and SVV, respectively. CONCLUSIONS: PPV, SPV, and SVV are the only reliable predictors of fluid responsiveness under strict conditions. In routine clinical practice, factors including low TV, cardiac arrhythmias, and the calculation method can substantially reduce their predictive value.


Asunto(s)
Puente de Arteria Coronaria , Fluidoterapia/métodos , Cuidados Posoperatorios/métodos , Anciano , Arritmias Cardíacas/fisiopatología , Gasto Cardíaco/fisiología , Sedación Consciente/métodos , Femenino , Hemodinámica/fisiología , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico/métodos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Respiración Artificial/métodos , Volumen de Ventilación Pulmonar/fisiología
9.
Br J Anaesth ; 107(3): 336-43, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21642643

RESUMEN

BACKGROUND: The transpulmonary thermodilution (TPTD) technique for measuring cardiac output (CO) has never been validated in the presence of a left-to-right shunt. METHODS: In this experimental, paediatric animal model, nine lambs with a surgically constructed aorta-pulmonary left-to-right shunt were studied under various haemodynamic conditions. CO was measured with closed and open shunt using the TPTD technique (CO(TPTD)) with central venous injections of ice-cold saline. An ultrasound transit time perivascular flow probe around the main pulmonary artery served as the standard reference measurement (CO(MPA)). RESULTS: Seven lambs were eligible for further analysis. Mean (sd) weight was 6.6 (1.6) kg. The mean CO(MPA) was 1.21 litre min(-1) (range 0.61-2.06 l min(-1)) with closed shunt and 0.93 litre min(-1) (range 0.48-1.45 litre min(-1)) with open shunt. The open shunt resulted in a mean Q(p)/Q(s) ratio of 1.8 (range 1.6-2.4). The bias between the two CO methods was 0.17 litre min(-1) [limits of agreement (LOA) of 0.27 litre min(-1)] with closed shunt and 0.14 litre min(-1) (LOA of 0.32 litre min(-1)) with open shunt. The percentage errors were 22% with closed shunt and 34% with open shunt. The correlation (r) between the two methods was 0.93 (P<0.001) with closed shunt and 0.86 (P<0.001) with open shunt. The correlation (r) between the two methods in tracking changes in CO (ΔCO) during the whole experiment was 0.94 (P<0.0001). CONCLUSIONS: The TPTD technique is a feasible method of measuring CO in paediatric animals with a left-to-right shunt.


Asunto(s)
Gasto Cardíaco , Cardiopatías Congénitas/fisiopatología , Termodilución/métodos , Animales , Aorta/fisiología , Modelos Animales de Enfermedad , Circulación Pulmonar , Ovinos , Choque Hemorrágico/fisiopatología
10.
Br J Anaesth ; 107(4): 540-5, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21700612

RESUMEN

BACKGROUND: Pulse pressure variation (PPV) and systolic pressure variation (SPV) are reliable predictors of fluid responsiveness in patients undergoing controlled mechanical ventilation. Currently, PPV and SPV are measured invasively and it is unknown if an arterial pressure (AP) signal obtained with a finger cuff can be used as an alternative. The aim of this study was to validate PPV and SPV measured using a finger cuff. METHODS: Patients receiving mechanical ventilation under sedation after cardiac artery bypass graft (CABG) surgery were included after arrival on the intensive care unit. AP was measured invasively in the radial artery and non-invasively using the finger cuff of the Nexfin™ monitor. I.V. fluid challenges were administered according to clinical need. The mean value of PPV and SVV was calculated before and after administration of a fluid challenge. Agreement of the calculated PPV and SPV from both methods was assessed using the Bland-Altman analysis. RESULTS: Nineteen patients were included and 28 volume challenges were analysed. Correlation between the two methods for PPV and SPV [mean (sd)=6.9 (4.3)% and 5.3 (2.6)%, respectively] was r=0.96 (P<0.0001) and r=0.95 (P<0.0001), respectively. The mean bias was -0.95% for PPV and -0.22% for SPV. Limits of agreement were -4.3% and 2.4% for PPV and -2.2% and 1.7% for SPV. The correlation between changes in PPV and SPV as a result of volume expansion measured by the two different methods was r=0.88 (P<0.0001) and r=0.87 (P<0.0001), respectively. CONCLUSIONS: In patients receiving controlled mechanical ventilation after CABG, PPV and SPV can be measured reliably non-invasively using the inflatable finger cuff of the Nexfin™ monitor.


Asunto(s)
Arterias/fisiología , Presión Sanguínea/fisiología , Dedos/irrigación sanguínea , Monitoreo Fisiológico/métodos , Anciano , Algoritmos , Sesgo , Arteria Braquial/fisiología , Puente de Arteria Coronaria , Interpretación Estadística de Datos , Femenino , Fluidoterapia , Humanos , Infusiones Intravenosas , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Pulso Arterial , Estándares de Referencia , Flujo Sanguíneo Regional/fisiología , Reproducibilidad de los Resultados , Sístole/fisiología
11.
Br J Anaesth ; 105(4): 493-500, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20693181

RESUMEN

BACKGROUND: Continuous non-invasive measurement of finger arterial pressure (FAP) is a reliable technology in adults. FAP is measured with an inflatable cuff around the finger and simultaneously converted to a reconstructed brachial artery pressure waveform (reBAP) by the Nexfin™ device. We assessed the adequacy of a prototype device (Nexfin-paediatric), designed for a paediatric population, for detecting rapid arterial pressure changes in children during cardiac surgery. METHODS: Thirteen anaesthetized children with a median age of 11 months (2 months-7 yr) undergoing congenital cardiac surgery were included in the study. reBAP and intra-arterial pressure (IAP) were recorded simultaneously during the surgical procedure. To assess the accuracy of reBAP in tracking arterial pressure changes, the four largest IAP variations within a 5 min time interval were identified from each procedure. These variations were compared offline with reBAP during a 10 s control period before and a 10 s period after an arterial pressure change had occurred. RESULTS: In 10 out of 13 children, a non-invasive arterial pressure recording could be obtained. Therefore, recordings from these 10 children were eligible for further analysis, resulting in 40 data points. The correlation coefficient between reBAP and IAP in tracking mean arterial pressure (MAP) changes was 0.98. reBAP followed changes in IAP with a mean bias for systolic, diastolic arterial pressure, and MAP of 0.0 mm Hg (sd 5.8), 0.1 (sd 2.8), and 0.19 (sd 2.7), respectively. CONCLUSIONS: The prototype device closely follows arterial pressure changes in children. However, in a considerable number of attempts, obtaining a signal was time-consuming or unsuccessful. This technique seems promising but requires further technical development.


Asunto(s)
Determinación de la Presión Sanguínea/métodos , Cardiopatías Congénitas/cirugía , Monitoreo Intraoperatorio/métodos , Presión Sanguínea , Determinación de la Presión Sanguínea/instrumentación , Monitores de Presión Sanguínea , Niño , Preescolar , Dedos/irrigación sanguínea , Humanos , Lactante , Monitoreo Intraoperatorio/instrumentación , Reproducibilidad de los Resultados
12.
Pediatr Cardiol ; 30(2): 205-7, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19052806

RESUMEN

Congenital coronary artery anomalies are a well-recognized risk factor for sudden cardiac death in children as well as young adults, mostly during or immediately after intense exertion on the athletic field. Because these malformations are amenable to surgical treatment, timely identification is crucial. Unfortunately, antemortem diagnosis is notoriously difficult, partly due to the absence of abnormal test results in routine investigations. We present a 15-year-old boy who collapsed during exercise due to ventricular fibrillation. Coronary abnormalities were initially not identified, but they were clearly visualized by means of an echocardiogram and confirmed by multislice computed tomography. We would like to emphasize that echocardiography is capable of accurately identifying congenital coronary anomalies when attention is paid to the correct diagnostic hallmarks.


Asunto(s)
Aorta/anomalías , Seno Coronario/anomalías , Anomalías de los Vasos Coronarios/patología , Adolescente , Aorta/diagnóstico por imagen , Seno Coronario/diagnóstico por imagen , Anomalías de los Vasos Coronarios/complicaciones , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Ecocardiografía , Humanos , Masculino , Seno Aórtico/anomalías , Tomografía Computarizada Espiral , Fibrilación Ventricular/etiología
13.
Intensive Care Med ; 34(12): 2268-72, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18787810

RESUMEN

OBJECTIVE: To measure the effect of intense neuromuscular blockade (NMB) on oxygen consumption (VO(2)) in deeply sedated and mechanically ventilated children on the first day after complex congenital cardiac surgery. DESIGN: Prospective clinical interventional study. SETTING: Pediatric intensive care unit of an university medical centre. MEASUREMENTS AND RESULTS: Nine mechanically ventilated and sedated children (weight 2.8-8.7 kg) were included. All children were treated with vasoactive drugs. The level of sedation was quantified using the comfort score, Ramsay score and bispectral index (BIS). The intensity of NMB was quantified using acceleromyography and VO(2) was measured using indirect calorimetry. Analgo-sedation using various intravenous agents was targeted at a deep level (comfort score < 18, BIS < 60 and Ramsay score > 4). NMB was achieved by intravenous administration of rocuronium. All measurements were conducted before, during and after recovery from a period of intense NMB. Baseline values were VO(2) 6.1 ml/(kg min) (SD 1.3), comfort score 13 (SD 0.7), BIS 42.5 (SD 14.2), mean blood pressure 54.0 mmHg (SD 10.5), mean heart rate 129.9 bpm (SD 28.9) and mean core temperature 36.7 degrees C (SD 0.5). There were no significant differences in VO(2) or other parameters between baseline, during NMB and the recovery phase. CONCLUSION: Neuromuscular blocking agents do not reduce oxygen consumption in deeply sedated and mechanically ventilated children after congenital cardiac surgery.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Sedación Profunda , Bloqueo Neuromuscular/efectos adversos , Consumo de Oxígeno/efectos de los fármacos , Respiración Artificial , Estudios de Cohortes , Humanos , Lactante , Recién Nacido , Unidades de Cuidados Intensivos
14.
Ned Tijdschr Geneeskd ; 152(19): 1106-12, 2008 May 10.
Artículo en Holandés | MEDLINE | ID: mdl-18552066

RESUMEN

OBJECTIVE: To investigate whether Helicopter-Mobile Medical Teams (H-MMTs or HEMS) are optimally deployed in all emergency dispatch centres. DESIGN: Descriptive, retrospective. METHOD: Initially, we assessed whether data from different ambulance regions could be compared effectively if they were related to the number of inhabitants per region. Data concerning the number of inhabitants, number of deaths caused by trauma, number of traffic accidents with injury, number ofemergency call-outs by ambulance services and H-MMT deployment were collected from several governmental databases for the period 2002-2005. The correlation coefficients between these data and the number of inhabitants were calculated. Subsequently, we determined the number of H-MMT deployments per 100,000 inhabitants per year per emergency dispatch centre. The number of H-MMT dispatches from the 4 H-MMT coordinating dispatch centres was compared to the number of dispatches from the 17 other emergency dispatch centres. RESULTS: There was a strong correlation between the number of deaths caused by trauma, the number of traffic accidents with injury, emergency call-outs from ambulance services, and the number of inhabitants per region (correlation coefficients: 0.90-0.98). On average there were 2664 H-MMT calls per year. The average number of H-MMT calls per emergency dispatch centre per year was 110 (range: 2-403). The number of H-MMT deployments per 100,000 inhabitants per year was 10.5 (0.9-27.8). Emergency dispatch centres coordinating H-MMTs conducted significantly more H-MMT calls with a lower cancellation rate. CONCLUSION: By relating the deployment of H-MMTs with the number of inhabitants per region, a comparison can be made of the deployment frequencies in different emergency dispatch regions. The deployment of H-MMTs proved to differ significantly between emergency dispatch centres.


Asunto(s)
Ambulancias Aéreas/estadística & datos numéricos , Densidad de Población , Accidentes de Tránsito/estadística & datos numéricos , Servicios Médicos de Urgencia , Humanos , Países Bajos , Estudios Retrospectivos