Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 10 de 10
1.
Heliyon ; 9(9): e19854, 2023 Sep.
Article En | MEDLINE | ID: mdl-37809666

Metagenomic next-generation sequencing (mNGS) is an untargeted technique capable of detecting all microbial nucleic acid within a sample. This protocol outlines our wet laboratory method for mNGS of cerebrospinal fluid (CSF) specimens and tissues from sterile sites. We use this method routinely in our clinical service, processing 178 specimens over the past 2.5 years in a laboratory that adheres to ISO:15189 standards. We have successfully used this protocol to diagnose multiple cases of encephalitis and hepatitis.

3.
Nature ; 617(7961): 564-573, 2023 May.
Article En | MEDLINE | ID: mdl-36996872

Since its first identification in Scotland, over 1,000 cases of unexplained paediatric hepatitis in children have been reported worldwide, including 278 cases in the UK1. Here we report an investigation of 38 cases, 66 age-matched immunocompetent controls and 21 immunocompromised comparator participants, using a combination of genomic, transcriptomic, proteomic and immunohistochemical methods. We detected high levels of adeno-associated virus 2 (AAV2) DNA in the liver, blood, plasma or stool from 27 of 28 cases. We found low levels of adenovirus (HAdV) and human herpesvirus 6B (HHV-6B) in 23 of 31 and 16 of 23, respectively, of the cases tested. By contrast, AAV2 was infrequently detected and at low titre in the blood or the liver from control children with HAdV, even when profoundly immunosuppressed. AAV2, HAdV and HHV-6 phylogeny excluded the emergence of novel strains in cases. Histological analyses of explanted livers showed enrichment for T cells and B lineage cells. Proteomic comparison of liver tissue from cases and healthy controls identified increased expression of HLA class 2, immunoglobulin variable regions and complement proteins. HAdV and AAV2 proteins were not detected in the livers. Instead, we identified AAV2 DNA complexes reflecting both HAdV-mediated and HHV-6B-mediated replication. We hypothesize that high levels of abnormal AAV2 replication products aided by HAdV and, in severe cases, HHV-6B may have triggered immune-mediated hepatic disease in genetically and immunologically predisposed children.


Adenovirus Infections, Human , Genomics , Hepatitis , Child , Humans , Acute Disease/epidemiology , Adenovirus Infections, Human/epidemiology , Adenovirus Infections, Human/immunology , Adenovirus Infections, Human/virology , B-Lymphocytes/immunology , Gene Expression Profiling , Hepatitis/epidemiology , Hepatitis/immunology , Hepatitis/virology , Immunohistochemistry , Liver/immunology , Liver/virology , Proteomics , T-Lymphocytes/immunology
4.
PLoS Med ; 19(10): e1004120, 2022 10.
Article En | MEDLINE | ID: mdl-36260627

BACKGROUND: Early antiviral treatment is effective for Coronavirus Disease 2019 (COVID-19) but currently available agents are expensive. Favipiravir is routinely used in many countries, but efficacy is unproven. Antiviral combinations have not been systematically studied. We aimed to evaluate the effect of favipiravir, lopinavir-ritonavir or the combination of both agents on Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) viral load trajectory when administered early. METHODS AND FINDINGS: We conducted a Phase 2, proof of principle, randomised, placebo-controlled, 2 × 2 factorial, double-blind trial of ambulatory outpatients with early COVID-19 (within 7 days of symptom onset) at 2 sites in the United Kingdom. Participants were randomised using a centralised online process to receive: favipiravir (1,800 mg twice daily on Day 1 followed by 400 mg 4 times daily on Days 2 to 7) plus lopinavir-ritonavir (400 mg/100 mg twice daily on Day 1, followed by 200 mg/50 mg 4 times daily on Days 2 to 7), favipiravir plus lopinavir-ritonavir placebo, lopinavir-ritonavir plus favipiravir placebo, or both placebos. The primary outcome was SARS-CoV-2 viral load at Day 5, accounting for baseline viral load. Between 6 October 2020 and 4 November 2021, we recruited 240 participants. For the favipiravir+lopinavir-ritonavir, favipiravir+placebo, lopinavir-ritonavir+placebo, and placebo-only arms, we recruited 61, 59, 60, and 60 participants and analysed 55, 56, 55, and 58 participants, respectively, who provided viral load measures at Day 1 and Day 5. In the primary analysis, the mean viral load in the favipiravir+placebo arm had changed by -0.57 log10 (95% CI -1.21 to 0.07, p = 0.08) and in the lopinavir-ritonavir+placebo arm by -0.18 log10 (95% CI -0.82 to 0.46, p = 0.58) compared to the placebo arm at Day 5. There was no significant interaction between favipiravir and lopinavir-ritonavir (interaction coefficient term: 0.59 log10, 95% CI -0.32 to 1.50, p = 0.20). More participants had undetectable virus at Day 5 in the favipiravir+placebo arm compared to placebo only (46.3% versus 26.9%, odds ratio (OR): 2.47, 95% CI 1.08 to 5.65; p = 0.03). Adverse events were observed more frequently with lopinavir-ritonavir, mainly gastrointestinal disturbance. Favipiravir drug levels were lower in the combination arm than the favipiravir monotherapy arm, possibly due to poor absorption. The major limitation was that the study population was relatively young and healthy compared to those most affected by the COVID-19 pandemic. CONCLUSIONS: At the current doses, no treatment significantly reduced viral load in the primary analysis. Favipiravir requires further evaluation with consideration of dose escalation. Lopinavir-ritonavir administration was associated with lower plasma favipiravir concentrations. TRIAL REGISTRATION: Clinicaltrials.gov NCT04499677 EudraCT: 2020-002106-68.


COVID-19 Drug Treatment , Humans , Lopinavir/therapeutic use , Pandemics , Ritonavir/therapeutic use , Antiviral Agents/adverse effects , SARS-CoV-2 , Treatment Outcome
5.
Clin Biomech (Bristol, Avon) ; 27(7): 673-9, 2012 Aug.
Article En | MEDLINE | ID: mdl-22503808

BACKGROUND: Cement-in-cement revision hip arthroplasty is an increasingly popular technique to replace a loose femoral stem which retains much of the original cement mantle. However, some concern exists regarding the retention of the existing fatigued and aged cement in such cement-in-cement revisions. This study investigates whether leaving an existing fatigued and aged cement mantle degrades the mechanical performance of a cement-in-cement revision construct. METHODS: Primary cement mantles were formed by cementing a polished stem into sections of tubular steel. If in the test group, the mantle underwent conditioning in saline to simulate ageing and was subject to a fatigue of 1 million cycles. If in the control group no such conditioning or fatigue was carried out. The cement-in-cement procedure was then undertaken. Both groups underwent a fatigue of 1 million cycles subsequent to the revision procedure. FINDINGS: Application of a Mann-Whitney test on the recorded subsidence (means: 0.51, 0.46, n=10+10, P=0.496) and inducible displacement (means: 0.38, 0.36, P=0.96) revealed that there was no statistical difference between the groups. INTERPRETATION: This study represents further biomechanical investigation of the mechanical behaviour of cement-in-cement revision constructs. Results suggest that pre-revision fatigue and ageing of the cement may not be deleterious to the mechanical performance of the revision construct. Thus, this study provides biomechanical evidence to back-up recent successes with this useful revision technique.


Biomimetic Materials/chemistry , Bone Cements/analysis , Bone Cements/chemistry , Cementation/methods , Femur/chemistry , Femur/surgery , Adhesiveness , Elastic Modulus , Humans , Reoperation , Surface Properties , Tensile Strength
6.
Proc Inst Mech Eng H ; 226(12): 927-38, 2012 Dec.
Article En | MEDLINE | ID: mdl-23636956

Reliable prediction of long-term medical device performance using computer simulation requires consideration of variability in surgical procedure, as well as patient-specific factors. However, even deterministic simulation of long-term failure processes for such devices is time and resource consuming so that including variability can lead to excessive time to achieve useful predictions. This study investigates the use of an accelerated probabilistic framework for predicting the likely performance envelope of a device and applies it to femoral prosthesis loosening in cemented hip arthroplasty. A creep and fatigue damage failure model for bone cement, in conjunction with an interfacial fatigue model for the implant-cement interface, was used to simulate loosening of a prosthesis within a cement mantle. A deterministic set of trial simulations was used to account for variability of a set of surgical and patient factors, and a response surface method was used to perform and accelerate a Monte Carlo simulation to achieve an estimate of the likely range of prosthesis loosening. The proposed framework was used to conceptually investigate the influence of prosthesis selection and surgical placement on prosthesis migration. Results demonstrate that the response surface method is capable of dramatically reducing the time to achieve convergence in mean and variance of predicted response variables. A critical requirement for realistic predictions is the size and quality of the initial training dataset used to generate the response surface and further work is required to determine the recommendations for a minimum number of initial trials. Results of this conceptual application predicted that loosening was sensitive to the implant size and femoral width. Furthermore, different rankings of implant performance were predicted when only individual simulations (e.g. an average condition) were used to rank implants, compared with when stochastic simulations were used. In conclusion, the proposed framework provides a viable approach to predicting realistic ranges of loosening behaviour for orthopaedic implants in reduced timeframes compared with conventional Monte Carlo simulations.


Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/statistics & numerical data , Hip Joint/surgery , Joint Instability/epidemiology , Joint Instability/surgery , Models, Biological , Models, Statistical , Arthroplasty, Replacement, Hip/methods , Computer Simulation , Humans , Incidence , Models, Chemical , Prognosis , Prosthesis Failure , Risk Assessment , Treatment Outcome
7.
J Biomech Eng ; 133(8): 081001, 2011 Aug.
Article En | MEDLINE | ID: mdl-21950894

One way to restore physiological blood flow to occluded arteries involves the deformation of plaque using an intravascular balloon and preventing elastic recoil using a stent. Angioplasty and stent implantation cause unphysiological loading of the arterial tissue, which may lead to tissue in-growth and reblockage; termed "restenosis." In this paper, a computational methodology for predicting the time-course of restenosis is presented. Stress-induced damage, computed using a remaining life approach, stimulates inflammation (production of matrix degrading factors and growth stimuli). This, in turn, induces a change in smooth muscle cell phenotype from contractile (as exists in the quiescent tissue) to synthetic (as exists in the growing tissue). In this paper, smooth muscle cell activity (migration, proliferation, and differentiation) is simulated in a lattice using a stochastic approach to model individual cell activity. The inflammation equations are examined under simplified loading cases. The mechanobiological parameters of the model were estimated by calibrating the model response to the results of a balloon angioplasty study in humans. The simulation method was then used to simulate restenosis in a two dimensional model of a stented artery. Cell activity predictions were similar to those observed during neointimal hyperplasia, culminating in the growth of restenosis. Similar to experiment, the amount of neointima produced increased with the degree of expansion of the stent, and this relationship was found to be highly dependant on the prescribed inflammatory response. It was found that the duration of inflammation affected the amount of restenosis produced, and that this effect was most pronounced with large stent expansions. In conclusion, the paper shows that the arterial tissue response to mechanical stimulation can be predicted using a stochastic cell modeling approach, and that the simulation captures features of restenosis development observed with real stents. The modeling approach is proposed for application in three dimensional models of cardiovascular stenting procedures.


Angioplasty, Balloon, Coronary , Computational Biology/methods , Coronary Vessels/pathology , Mechanical Phenomena , Models, Biological , Stents , Biomechanical Phenomena , Calibration , Coronary Restenosis/complications , Coronary Restenosis/pathology , Coronary Restenosis/physiopathology , Coronary Restenosis/therapy , Coronary Vessels/physiopathology , Humans , Inflammation/complications , Inflammation/pathology , Prosthesis Design
9.
J Orthop Res ; 25(6): 779-88, 2007 Jun.
Article En | MEDLINE | ID: mdl-17343282

Advances in surgical procedure, prosthesis design, and biomaterials performance have considerably increased the longevity of total joint replacements. Preoperative planning is another step in joint replacement that may have the potential to improve clinical outcome for the individual patient, but has remained relatively consistent for a long time. One means of advancing this aspect of joint replacement surgery may be to include predictive computer simulation into the planning process. In this article, the potential of patient-specific finite element analysis in preoperative assessment is investigated. Seventeen patient-specific finite element models of cemented Charnley reconstructions were created, of which six were early (<10 years) revisions. Creep was simulated using a Maxwell model, and fatigue damage was simulated using an anisotropic continuum damage formulation. Account was taken of the relationship between annual loading cycles and age, and stair-climbing loads were included using a walking to stair-climbing cycle ratio of 9:1. Simulations for the equivalent of 10 years of loading were performed. Accumulated damage, inducible displacement, and migration were computed. Five of the six early revisions had the highest migration indicating that migration could have been used to identify early failures of these prostheses. Resultant migration showed the most significant difference between the early revised and unrevised groups (p = 0.0024). Furthermore, this trend was apparent from 1 year postimplantation (p = 0.0052). This ability to differentiate early revisions shows that computational simulation of aseptic loosening in cemented prostheses could prove clinically useful in helping surgeons optimize the preoperative plan for individual patients.


Arthroplasty, Replacement, Hip/adverse effects , Computer Simulation , Finite Element Analysis/statistics & numerical data , Models, Biological , Prosthesis Failure , Adult , Aged , Arthroplasty, Replacement, Hip/statistics & numerical data , Databases, Factual/statistics & numerical data , Female , Femur , Hip Joint/diagnostic imaging , Hip Joint/physiology , Hip Joint/surgery , Humans , Male , Middle Aged , Predictive Value of Tests , Preoperative Care , Radiography , Risk Factors , Weight-Bearing
10.
J Biomech ; 40(7): 1525-33, 2007.
Article En | MEDLINE | ID: mdl-17070816

One possible loosening mechanism of the femoral component in total hip replacement is fatigue cracking of the cement mantle. A computational method capable of simulating this process may therefore be a useful tool in the preclinical evaluation of prospective implants. In this study, we investigated the ability of a computational method to predict fatigue cracking in experimental models of the implanted femur construct. Experimental specimens were fabricated such that cement mantle visualisation was possible throughout the test. Two different implant surface finishes were considered: grit blasted and polished. Loading was applied to represent level gait for two million cycles. Computational (finite element) models were generated to the same geometry as the experimental specimens, with residual stress and porosity simulated in the cement mantle. Cement fatigue and creep were modelled over a simulated two million cycles. For the polished stem surface finish, the predicted fracture locations in the finite element models closely matched those on the experimental specimens, and the recorded stem displacements were also comparable. For the grit blasted stem surface finish, no cement mantle fractures were predicted by the computational method, which was again in agreement with the experimental results. It was concluded that the computational method was capable of predicting cement mantle fracture and subsequent stem displacement for the structure considered.


Arthroplasty, Replacement, Hip/methods , Bone Cements/standards , Finite Element Analysis , Hip Prosthesis/standards , Prosthesis Failure , Computer Simulation , Femur , Humans , Materials Testing , Prosthesis Design
...