Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Pediatr Cardiol ; 44(7): 1471-1478, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37439830

RESUMEN

Percutaneous balloon pulmonary valvuloplasty (PBPV) is an alternative intervention in infants with Tetralogy of Fallot (TOF). It can not only improve hypoxia but also promote pulmonary annulus (PA) growth. In this study, we evaluated the effect of PBPV on PA growth in infants with TOF. To eliminate the effect of the systemic to pulmonary shunt (SPS) that may promote PA growth, we divided TOF infants into 2 groups: group A, patients who underwent PBPV with or without other SPS, and group B, patients who attempted SPS but without PBPV. Sixty patients were included, 28 patients in group A and 32 patients in group B. Age at the time of intervention in group A (range, 0.4-5.4; median 1.4 months) was lower than that in group B (range, 2.3-7.7; median 4.8 months), p-value 0.02. The body weight in group A (range, 3-5.5; median 3.7 kg) was also lower than that in group B (range 4.1-6.4; median 5.9 kg), p-value 0.02. Echocardiographic data at the mean follow-up period of 37.2 months (3-88 months) in group A and 39.6 months (6-95 months) in group B demonstrated an increase in mean PA diameter from 5.0 ± 1.3 mm to 10.2 ± 2.9 mm, p-value < 0.001 in group A; and from 6.2 ± 2 mm to 9.5 ± 2.9 mm, p-value < 0.001 in group B. The median PA z-score increased from - 3.4SD (- 3.9 to - 2.6SD) to - 1.8SD (- 2.5 to - 0.8SD), with the p-value of 0.002 in group A; and increased from - 2.9SD (- 4.5 to - 1.3SD) to - 2.7SD (- 3.6 to - 1.4SD), with the p-value of 0.73 in group B. By using the PA z-score as the absolute value, there was a statistically significant increase in the PA z-score during follow-up in group A, but not in group B. Balloon pulmonary valvuloplasty in infants with TOF can facilitate the growth of the pulmonic annulus even after eliminating the effect of the systemic to pulmonary shunt.


Asunto(s)
Valvuloplastia con Balón , Válvula Pulmonar , Tetralogía de Fallot , Humanos , Lactante , Tetralogía de Fallot/cirugía , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Resultado del Tratamiento , Ecocardiografía , Estudios Retrospectivos
2.
Pacing Clin Electrophysiol ; 46(12): 1604-1608, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37120827

RESUMEN

INTRODUCTION: Transvenous pacemaker implantation in patients post bidirectional Glenn anastomosis in one-and-a-half ventricle repair is usually not feasible. However, with a modified surgical technique for Glenn anastomosis and a combined interventional and electrophysiologic approach, the transvenous pacemaker was successfully implanted. FINDINGS AND CONCLUSIONS: We reported a novel technique of pacemaker implantation in a 27-year-old woman, underlying Ebstein anomaly of the tricuspid valve, who developed intermittent complete atrioventricular block at 5 years after surgical repair. The patient had a tricuspid valve replacement and a novel modified bidirectional Glenn anastomosis for one-and-a-half ventricle repair. The Glenn circuit was conducted by opening a window between the posterior wall of the superior vena cava (SVC) and the anterior wall of the right pulmonary artery (RPA), combined with putting a Goretex membrane in the SVC below the SVC-RPA window without disconnecting the SVC from the right atrium. The transvenous pacemaker was implanted by perforating the Goretex membrane, then passing the leads from the axillary vein through the perforated membrane and placing them in the coronary sinus and right atrium.


Asunto(s)
Anomalía de Ebstein , Marcapaso Artificial , Femenino , Humanos , Adulto , Anomalía de Ebstein/complicaciones , Anomalía de Ebstein/cirugía , Válvula Tricúspide/cirugía , Vena Cava Superior , Resultado del Tratamiento , Politetrafluoroetileno
3.
Heart Vessels ; 37(5): 875-883, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34714397

RESUMEN

BACKGROUND: Transcatheter ductus arteriosus stenting (DS) is emerging as an alternative method to modified Blalock-Taussig shunt (MBTS) in providing pulmonary blood flow in cyanotic congenital heart disease (CCHD) with duct-dependent pulmonary circulation. OBJECTIVE: To evaluate post-procedural outcomes and survival between patients undergoing DS and MBTS. METHODS: All infants ≤ 60 days of age having CCHD with diminished pulmonary blood flow who underwent palliative procedure either with MBTS or DS at King Chulalongkorn Memorial Hospital during January 1st, 2013 and December 31th, 2017 were retrospectively reviewed. RESULTS: 98 patients were included; 34 patients underwent a transcatheter DS and 64 patients underwent MBTS. There was no significant difference in post-procedural outcomes and overall mortality rate between two groups (17.6% in MBTS group and 6.1% in DS group, p = 0.09). Single ventricle morphology was the major risk factor associated with increased mortality compared with biventricular morphology (aHR 3.9, 95% CI 1.49-10.2, p = 0.01). There was similar number of early and pre-repair additional interventions focusing on MBTS/DS patency between two groups. The MBTS group had a greater number of early interventions on PA branch stenosis related to baseline diagnosis. Risk factors associated with additional intervention were pre-existing pulmonary branch stenosis (aHR 2.54, 95% CI 1.3-4.97, p = 0.006) and body weight less than 2.5 kg (aHR 3.33, 95% CI 1.57-7.08, p = 0.003). Having pulmonic valve perforation or balloon pulmonary valvuloplasty to promote antegrade pulmonary blood flow could result in a lower number of additional interventions required before definitive repair. CONCLUSION: Duct stenting is a feasible and safe alternative to MBTS in cyanotic infants with duct-dependent pulmonary circulation. However, mortality rate was significantly higher in patients with single ventricle that required careful follow-up after procedure.


Asunto(s)
Procedimiento de Blalock-Taussing , Cardiopatías Congénitas , Estenosis de la Válvula Pulmonar , Procedimiento de Blalock-Taussing/efectos adversos , Procedimiento de Blalock-Taussing/métodos , Constricción Patológica , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/cirugía , Humanos , Lactante , Arteria Pulmonar/cirugía , Circulación Pulmonar , Estudios Retrospectivos , Resultado del Tratamiento
4.
Catheter Cardiovasc Interv ; 97(7): E1011-E1018, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-33034944

RESUMEN

OBJECTIVES: This study aimed to present a new approach of thorough preclinical testing of a novel left atrial appendage (LAA) occluder device. BACKGROUND: The development of a safe and effective LAA occluder has been shown to be challenging. METHODS: The novel OMEGATM LAA occluder (Eclipse Medical, Ireland) was tested in a porcine model and three-dimensional (3D) human LAA models - this as a prelude to its first-in-human use. RESULTS: In a first series of in-vivo experiments, the OMEGATM LAA occluder was shown to have a satisfactory device biocompatibility in a porcine model. The design of the OMEGATM device was further refined and optimized following three more series of in-vivo experiments. The second generation OMEGATM device was designed with thinner wires, leading to a profile reduction. Based on in-vitro testing of different OMEGATM device sizes implanted at different depths in human three-dimensional (3D) LAA models, it could be determined that (1) the landing zone should be measured at a median depth of 12 mm from the LAA ostium; (2) the distal self-retaining inverted cup should have 10%-25% compression to minimize device embolization risk; and (3) the disc should be slightly inverted, i.e. pulled into the LAA, to promote complete LAA occlusion. The combined in-vivo and in-vitro testing resulted in an optimized pre-procedural planning of the first-in-human case treated with the OMEGATM device. CONCLUSIONS: This series of carefully planned in-vivo and in-vitro experiments allowed demonstration of the safety and efficacy of the OMEGATM LAA occluder. This approach of thorough preclinical testing of medical devices may reduce the risk of complications in first-in-human cases and may become the standard approach for device development and preclinical testing in the future.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Dispositivo Oclusor Septal , Animales , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Cateterismo Cardíaco/efectos adversos , Ecocardiografía Transesofágica , Humanos , Porcinos , Resultado del Tratamiento
5.
J Cardiol Cases ; 20(1): 14-19, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31320947

RESUMEN

Takotsubo syndrome is a rare cause of reversible ventricular dysfunction that imitate an acute coronary syndrome. The entity is unusual among pediatric populations and a recurrent episode is extremely rare. We report a case of recurrent takotsubo syndrome in an eight-year-old boy with Duchenne muscular dystrophy (DMD). His chest pain episodes were aggravated by a strong emotional stimuli. During episodes of chest pain, electrocardiograms (ECG) showed ST elevation while echocardiograms showed left ventricle apical ballooning; however, a coronary angiography was normal. Serial ECG and echocardiogram revealed a spontaneous resolution of ST elevation and normalized apical contraction which were compatible with the diagnosis of takotsubo syndrome. Interestingly, serial cardiac magnetic resonance imaging demonstrated increasing subepicardial enhancement which was compatible with progression of cardiac involvement in DMD. .

6.
J Arrhythm ; 31(5): 296-301, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26550086

RESUMEN

BACKGROUND: Congenital long QT syndrome (LQTS) is a genetically transmitted cardiac channelopathy that can lead to lethal arrhythmia and sudden cardiac death in healthy young people. The clinical characteristics of LQTS are variable and depend on the subtype of long QT syndrome, which differ among populations. This single hospital-based case review study examined the clinical presentation of long QT syndrome and the outcomes of its treatment in 20 Thai children at King Chulalongkorn Memorial Hospital in Bangkok, Thailand. METHODS: Inpatient and outpatient records of children (aged 0-14 years) diagnosed with long QT syndrome from January 1, 1998, to September 30, 2013, were retrospectively reviewed. Presentation at diagnosis, treatments, and clinical courses were collected and analyzed. In the 20 subjects, total Schwartz scores totaled 5.2±0.9 points, and mean age at diagnosis was 7.6±4.4 years (range, 1 day-13.8 years). The patients were assigned to one of 3 groups based on trigger events: 50% of patients had events at rest (sleep or at rest), 35% experienced adrenergic-mediated events (e.g., stress, exercise, startle), and 15% were asymptomatic. Excluding the 3 patients who died at first presentation, 100% of patients received a beta blocker, and 47.1% were treated with an automatic implantable cardioverter-defibrillator (AICD). RESULTS: At follow-up (median=959 days; range, 1-4170 days), 4 patients (20%) were known to have died, 3 of whom died shortly after the diagnosis. Among patients who survived the initial event, 52.9% (9 of 17) experienced cardiac events (appropriate AICD shock, death, and/or syncope) during the follow-up period. The mean duration from diagnosis to cardiac event was 1420±759 days (range, 497-2499 days). CONCLUSIONS: All 20 patients with LQTS were mostly symptomatic at presentation. Owing to the geographical region and ethnicity of the Thai population, we conclude that the ratio of patients who develop cardiac symptoms at rest or during sleep might be higher than in other Asian countries.

7.
J Med Assoc Thai ; 98 Suppl 1: S107-10, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25764621

RESUMEN

OBJECTIVE: The Cocoon PFO Occluder is a device for percutaneous closure of inter-atrial communications. Its self-centering characteristics make it attractive for closure of patent foramen ovales (PFOs) with or without atrial septal aneurysms. The goal of this study is to report the immediate and follow-up results of the first 14 patients in implanted with the Cocoon PFO Occluder. MATERIAL AND METHOD: This is a retrospective report of immediate and short-term clinical and echocardiographic outcome of patients who underwent transcatheter closure of PFO because of paradoxical embolism. Procedural success was defined as successful deployment of the device and effective occlusion (no, or trivial, shunt after device placement). All patients had a transesophageal echocardiography (TEE) with saline contrast injection at baseline and clinical follow-up at 6 months. RESULTS: Between September 2012 and March 2014, 14 patients had successfully undergone transcatheter closure of PFO using Cocoon device. During follow-up none of the patients had a recurrence of stroke after device closure. No residual shunt was observed in any patients at follow-up. CONCLUSION: Transcatheter closure of PFO with the Cocoon PFO device is safe and effective and can be used for preventing recurrent strokes in patients who present with cryptogenic stroke and PFO.


Asunto(s)
Foramen Oval Permeable/cirugía , Prótesis e Implantes , Accidente Cerebrovascular/fisiopatología , Adulto , Anciano , Ecocardiografía Transesofágica , Femenino , Foramen Oval Permeable/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
9.
Catheter Cardiovasc Interv ; 83(1): E101-4, 2014 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-24039116

RESUMEN

Iatrogenic arteriovenous fistula is not a common complication of central venous catheterization. Duct occluder devices have been developed for patent ductus arteriosus occlusions but they may be used for arteriovenous fistula closures. We report a case of iatrogenic brachiocephalic-jugular and aortopulmonary artery fistulas after central venous catheter insertion. The fistulas were successfully managed with duct occluder devices. Due to increasing number of central venous catheterizations, physicians should be aware of this uncommon complication. Transcatheter closing of brachiocephalic-jugular and aortopulmonary artery fistulas by duct occluder devices seems to be a safe and feasible form of treatment.


Asunto(s)
Fístula Arterio-Arterial/terapia , Fístula Arteriovenosa/terapia , Tronco Braquiocefálico , Cateterismo Venoso Central/efectos adversos , Cateterismo Periférico , Procedimientos Endovasculares , Enfermedad Iatrogénica , Venas Yugulares , Arteria Pulmonar/anomalías , Aortografía/métodos , Fístula Arterio-Arterial/diagnóstico , Fístula Arterio-Arterial/etiología , Fístula Arteriovenosa/diagnóstico , Fístula Arteriovenosa/etiología , Tronco Braquiocefálico/diagnóstico por imagen , Cateterismo Periférico/instrumentación , Procedimientos Endovasculares/instrumentación , Humanos , Venas Yugulares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Flebografía/métodos , Diálisis Renal , Dispositivo Oclusor Septal , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
10.
J Invasive Cardiol ; 25(10): 525-8, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24088427

RESUMEN

OBJECTIVES: To evaluate the feasibility and efficacy of a new nanoplatinum-coated nitinol device for transcatheter ventricular septal defect (VSD) closure in a swine model. BACKGROUND: In spite of its good closure results, the previous version of Amplatzer perimembranous VSD device had a relatively high incidence of complete heart block as compared to surgical closure. This new VSD device is made from meshed nitinol wires, nanoplatinum-coated and filled with polypropylene sheaths to enhance thrombogenicity. With special design, the device has minimal expanding pressure on the nearby tissue. This may reduce the possibility of atrioventricular block after implantation. METHODS: VSD was created in 12 pigs via retrograde aortic approach, by ventricular septal puncture with Brokenbrough needle and ventricular septal balloon dilation, under echocardiographic and fluoroscopic guidance. After imaging study, the device was deployed for VSD closure. RESULTS: The device was successfully deployed to close the created VSD in all 12 animals. Angiographic and echocardiographic studies demonstrated complete closure of the VSD in 11 animals. One animal had residual VSD leakage. Three animals had unstable hemodynamics and died within 12 hours after the procedure. The remaining 9 animals survived in normal condition. The autopsy findings demonstrated complete endothelialization at 8 weeks after implantation. CONCLUSION: Transcatheter VSD closure with the new nanoplatinum-coated nitinol device is feasible and efficacious. The good occlusion results and complete endothelialization after implantation in the swine model potentiates human application.


Asunto(s)
Aleaciones , Cateterismo Cardíaco/métodos , Materiales Biocompatibles Revestidos , Defectos del Tabique Interventricular/cirugía , Nanoestructuras , Platino (Metal) , Dispositivo Oclusor Septal , Animales , Modelos Animales de Enfermedad , Ecocardiografía , Defectos del Tabique Interventricular/diagnóstico por imagen , Prótesis e Implantes , Diseño de Prótesis , Porcinos , Resultado del Tratamiento
11.
J Med Assoc Thai ; 96(9): 1127-34, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24163987

RESUMEN

BACKGROUND: Atrial septal defect (ASD) is a common congenital heart disease in adults. Amplatzer septal occluder is one of the most common devices used for transcatheter closure due to its high success rate and ease to implant. Cocoon atrial septal occluder is a new nitinol-based device, its shape resembles Amplatzer septal occluder but coated with platinum to prevent nickel release. Little is known about clinical outcomes of large ASD closure using Cocoon atrial septal occluder OBJECTIVE: To review our experience in closure of secundum ASD in adults by Cocoon septal occluder and to compare the clinical outcomes and results of the patients who had ASD closure with a device greater than or equal to 30 mm and less than 30 mm. MATERIAL AND METHOD: Between November 2005 and October 2008, 63 consecutive patients underwent transesophageal echocardiography (TEE)--guided transcatheter closure of secundum ASD. The patients were divided into two groups (Groups' 1 and 2) according to device diameter that is greater than or equal to 30 mm (n = 31) and less than 30 mm (n = 32), respectively. Clinical outcomes, complications, and transthoracic echocardiography (TTE) before hospital discharge, one to three months, and one-year were analyzed. RESULTS: Device implantations were successful in 27 patients (87.1%) in group 1 and 31 patients (96.9%) in group 2 (p = 0.196). The maximum size of secundum ASD in group 1 determined by TTE, TEE, and balloon sizing diameter (BSD) were 22.6 +/- 5.0 mm (range 15-32), 28.1 +/- 4.8 mm (range 19-39), and 31 +/- 3.5 mm (range 23-38) respectively. The maximum size of secundum ASD in group 2 determined by TTE, TEE, and BSD were 19.7 +/- 4.4 mm (range 12-31), 20.4 +/- 3.4 mm (range 13-26), and 23.1 +/- 2.9 mm (range 15-30) respectively. The mean device size in groups 1 and 2 were 33.5 +/- 3.1 mm and 24.6 +/- 3.3 mm, respectively. Four patients (12.9%) in group 1 had unsuccessful implantations. All of them were in the first 15 cases of using large device and two of them had device embolization requiring surgical removal. One patient (3.1%) in group 2 had an unsuccessful implantation and had device embolization requiring surgical removal. The patients in both groups gradually improved in clinical symptoms with decreased RVsystolic pressure and decreased RV size with complete ASD closure at one year CONCLUSION: Transcatheter closure of large secundum ASD by Cocoon septal occluder is feasible with hemodynamic benefit. However complication rates are higher with large ASD closure with device size greater than or equal to 30 mm especially during the early "learning curve" period. With experience, the complication rate declines and the success rate is no different from the group with smaller device size.


Asunto(s)
Defectos del Tabique Interatrial/cirugía , Dispositivo Oclusor Septal , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Aleaciones , Cateterismo Cardíaco , Ecocardiografía Transesofágica , Estudios de Factibilidad , Femenino , Defectos del Tabique Interatrial/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Diseño de Prótesis , Resultado del Tratamiento
12.
J Med Assoc Thai ; 96(11): 1428-33, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24428092

RESUMEN

BACKGROUND: New topical treatments studied in adults have been published to be potentially effective in the treatment of hypertrophic scar and keloids. There is still no study in Thai children. OBJECTIVE: To study the efficacy of 10% onion extract in silicone derivative gel for the prevention of hypertrophic scar and keloid in median sternotomy wound from open heart surgery in pediatric patients. MATERIAL AND METHOD: Thirty-nine pediatric patients who had median sternotomy were recruited in this prospective randomized, double-blinded, placebo-controlled split-scar experimental study. The wound in each patient was divided into upper and lower parts, and the treatment with, either onion extract gel or placebo was randomly applied by block randomization onto each part of the wound twice daily after the seventh day postoperatively for six months. The incidence of scars, serial photographs of the wound, Vancouver Scar Scale (VSS), and adverse effect were assessed at each visit. RESULTS: Thirty patients with the mean age of 4.3 years completed the 6-month study period. Six patients (20%) in onion extract gel group had no scar compared to one patient (3.3%) in placebo group (p = 0.04). Of the 27 patients with hypertrophic scar nine were from onion extract gel group and 18 from the placebo group (p = 0.02). Keloid was not statistically significant diferent in both groups (p = 0.29). VSS was not statistically significant different in all visits. One case had a pustule on the part of the onion extract in silicone derivative application at the sixth month. CONCLUSION: Onion extract in silicone derivative gel can significantly decreased the incidence of hypertrophic scar from median sternotomy wound in pediatric patients. Keloid did not show statistically significant differences in both groups.


Asunto(s)
Cicatriz Hipertrófica/prevención & control , Queloide/prevención & control , Cebollas , Fitoterapia , Extractos Vegetales/uso terapéutico , Geles de Silicona/uso terapéutico , Esternotomía , Adolescente , Niño , Preescolar , Método Doble Ciego , Femenino , Humanos , Lactante , Masculino , Estudios Prospectivos , Geles de Silicona/química
13.
J Med Assoc Thai ; 93(8): 898-902, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20718164

RESUMEN

BACKGROUND: Balloon pulmonary valvuloplasty and its benefit on the growth of pulmonary annulus and pulmonary artery in tetralogy of Fallot (TOF) patients remains controversial. The purpose ofthe present study was to determine the growth of pulmonary valve annulus and pulmonary artery and to evaluate the need of transannular patch during total surgical correction in patients with tetralogy of Fallot (TOF) after balloon pulmonary valvuloplasty. MATERIAL AND METHOD: Fifty-one severely hypoxic TOF patients, who underwent balloon dilatation ofpulmonary valve, were included in the present study. The clinical outcomes, oxygen saturation, and echocardiographic parameters before and after balloon dilatation were analyzed. RESULTS: There were 33 males and 18females. The mean age was 3 years 5 months old (range, I month-15 years 8 months old). The mean oxygen saturation increasedfrom 73.9 +/- 9.1 to 84.8 +/- 6.7% immediately after the procedure (p-value < 0.05). There was no serious procedural-related complication. At the mean follow-up period of 2 years and 4 months, the mean Z-score of pulmonary annulus size increased from -2.56 SD to -1.87 SD (p-value < 0.05) and the right pulmonary artery size from -0.29 SD to + 0.46 SD (p-value < 0.05). Thirty-seven patients (66.1%) underwent corrective surgery. Pulmonary transannular patch was performed in 11 of37 patients (29.7%). CONCLUSION: Pulmonary valve dilatation in patients with TOF is safe. It promotes the growth ofthe pulmonary valve annulus and pulmonary artery and may decrease the need of transannular patch at the time of surgical correction.


Asunto(s)
Cateterismo , Estenosis de la Válvula Pulmonar/cirugía , Tetralogía de Fallot/cirugía , Adolescente , Cateterismo Cardíaco , Niño , Preescolar , Ecocardiografía , Femenino , Estudios de Seguimiento , Humanos , Lactante , Recién Nacido , Masculino , Cuidados Paliativos/métodos , Arteria Pulmonar/crecimiento & desarrollo , Válvula Pulmonar/crecimiento & desarrollo , Estenosis de la Válvula Pulmonar/diagnóstico , Factores de Riesgo , Tetralogía de Fallot/diagnóstico , Factores de Tiempo , Resultado del Tratamiento
14.
J Invasive Cardiol ; 21(6): 286-9, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19494407

RESUMEN

BACKGROUND: An occluding device for closure of patent ductus arteriosus (PDA) was developed from meshed nitinol wires coated with platinum for prevention of nickel release after implantation. OBJECTIVES: Our purpose was to assess the immediate and short-term results of transcatheter PDA closure with this device. METHODS: Sixty patients (13 males and 47 females) underwent catheter-based PDA closure. The age ranged from 9 months to 65 years, with a median age of 4 years. The weight ranged from 4.2-65 kg, with a median of 15.2 kg. The mean PDA diameter at the narrowest segment was 4.7 +/- 2.2 mm, with a range of 2.0-15.1 mm. Eighteen cases had serial blood samples for serum nickel analysis taken before and at 1, 3 and 30 days after device implantation. RESULTS: The devices were successfully deployed in all 60 patients. There were no serious procedural complications. Color Doppler demonstrated complete occlusion rate of 78.3%, 90.0% and 100% at 1 day, 1 month and 1 year after implantation, respectively. There was no statistical difference in serum nickel concentrations between pre- and post-implantation. CONCLUSION: Transcatheter PDA closure using a platinum-coated nitinol device can be performed safely and successfully. There was no evidence of nickel release or nickel reaction after device implantation. This device model may be an alternative for PDA closure, especially in patients with potential nickel allergy.


Asunto(s)
Aleaciones , Conducto Arterioso Permeable/cirugía , Equipos y Suministros , Platino (Metal) , Procedimientos Quirúrgicos Vasculares/instrumentación , Procedimientos Quirúrgicos Vasculares/métodos , Adolescente , Adulto , Anciano , Aleaciones/efectos adversos , Cateterismo , Niño , Preescolar , Conducto Arterioso Permeable/sangre , Conducto Arterioso Permeable/diagnóstico por imagen , Diseño de Equipo , Equipos y Suministros/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Lactante , Masculino , Persona de Mediana Edad , Níquel/efectos adversos , Níquel/sangre , Platino (Metal)/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Ultrasonografía Doppler en Color , Procedimientos Quirúrgicos Vasculares/efectos adversos , Adulto Joven
15.
Pediatr Cardiol ; 30(4): 472-6, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19184175

RESUMEN

BACKGROUND: Endothelial activation and vascular inflammation are thought to be the mechanisms of pulmonary hypertension. Increased expression of the intercellular adhesion molecule (ICAM-1) and raised serum level of its soluble form (sICAM-1) are found in various conditions associated with endothelial activation. METHODS: Serum samples from 31 children (14 boys and 17 girls; age, 4.9 +/- 4.6 years) with congenital heart disease (CHD) collected at the time of cardiac catheterization were analyzed for sICAM-1 level. Uni- and multivariable stepwise linear regression analyses were performed for the following variables against the sICAM-1 level: age, hemoglobin, serum creatinine, systemic arterial pressure (SAP), pulmonary arterial pressure (PAP), pulmonary blood flow (Qp) and resistance (Rp), systemic blood flow (Qs) and resistance (Rs), Qp/Qs, Rp/Rs, and pulmonary and systemic oxygen saturation. RESULTS: The sICAM-1 levels in children who had CHD with and without pulmonary hypertension were 411 +/- 110 and 344 +/- 81 ng/ml, respectively (p = 0.11). In the univariable models, age, serum creatinine, systolic PAP, mean PAP, diastolic PAP, Rp, and Rp/Rs were significantly correlated with sICAM-1 level. In the multiple stepwise regression model, only mean PAP remained as an independent predictor of sICAM-1 level (r = 0.55; p = 0.002). CONCLUSION: Children with CHD and pulmonary hypertension had a trend toward elevated sICAM-1 compared with CHD children who had no pulmonary hypertension. A linear correlation was found between mean pulmonary arterial pressure and sICAM-1 level.


Asunto(s)
Endotelio Vascular/metabolismo , Cardiopatías Congénitas/sangre , Hipertensión Pulmonar/sangre , Molécula 1 de Adhesión Intercelular/sangre , Adolescente , Niño , Preescolar , Femenino , Humanos , Lactante , Recién Nacido , Masculino
16.
J Invasive Cardiol ; 20(6): 279-83, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18523320

RESUMEN

BACKGROUND: A variety of nitinol-containing devices for transcatheter closure of atrial septal defects (ASD) has been widely used. However, there is concern about the release of nickel after nitinol device implantation. In this study, a platinum-coated nitinol device was braided from nanoplatinum-coated nitinol wires in order to prevent nickel release. The serum nickel levels before and after device implantation and the 1-year results were evaluated. METHODS: Thirty-one patients, aged 4-59 years, and weighing 13.7-90.0 kg, underwent transcatheter closure. Blood samples for serum nickel levels were taken before, 1 day, 1 week, 1 month and 3 months after implantation. RESULTS: Twenty-nine (93.6%) patients had a successful implantation. The mean ASD diameter was 19.7 +/- 4.8 mm (range 10-30 mm). Procedure-related complications included transient brachial plexus injury in 1 patient and transient dysrhythmia in 4 patients. All 29 patients had complete closure within 1 month after implantation. The mean serum nickel levels at baseline and at 1 day, 1 week, 1 month and 3 months after implantation were 0.65 +/- 0.28, 0.63 +/- 0.18, 0.67 +/- 0.34, 0.55 +/- 0.16, 0.52 +/- 0.14 ng/ml, respectively. There was no significant difference in serum nickel levels before and after implantation. There were no device-related complications at 1-year follow up. CONCLUSIONS: Transcatheter ASD closure using a platinum-coated nitinol device can be performed safely and successfully with good outcomes. Nano-coating of platinum on nitinol wires can prevent nickel release following device implantation.


Asunto(s)
Aleaciones/efectos adversos , Cateterismo Cardíaco/efectos adversos , Defectos del Tabique Interatrial/terapia , Hipersensibilidad/prevención & control , Níquel/efectos adversos , Compuestos de Platino/efectos adversos , Adolescente , Adulto , Cateterismo Cardíaco/instrumentación , Niño , Preescolar , Femenino , Humanos , Hipersensibilidad/etiología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo
17.
Asian Cardiovasc Thorac Ann ; 16(3): 189-93, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18515666

RESUMEN

Primary repair is preferable to palliation in infants with truncus arteriosus. At our institute, an appropriately small homograft valved conduit is not available for every patient; a bicuspidized pulmonary valve homograft is an alternative. Between December 1996 and August 2005, 24 patients aged 28 days to 21 months with truncus arteriosus underwent primary repair with a homograft valved conduit; bicuspidized homografts were used in 15 of them. In the 18 (75%) patients who survived to hospital discharge, 5-year survival was 94% (75% for tricuspid homografts and 100% for bicuspidized homografts, which was not significantly different). Freedom from reoperation or balloon angioplasty in all 18 survivors was 89% at 5 years. Freedom from reoperation in tricuspid and bicuspidized homograft groups at 5 years was 67% and 100%, respectively; the difference was not statistically significant. Bicuspidized homografts worked as well as tricuspid conduits in the intermediate term. The remodeled homografts showed excellent hemodynamic characteristics and appear to be a reasonable alternative when an appropriate size of valved homograft is unavailable.


Asunto(s)
Prótesis Vascular , Diseño de Prótesis , Arteria Pulmonar/trasplante , Válvula Pulmonar/trasplante , Válvula Tricúspide/trasplante , Tronco Arterial Persistente/cirugía , Aorta/trasplante , Estudios de Cohortes , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Tasa de Supervivencia , Resultado del Tratamiento , Tronco Arterial Persistente/complicaciones , Tronco Arterial Persistente/mortalidad
18.
Pediatr Crit Care Med ; 8(6): 524-9, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17906598

RESUMEN

OBJECTIVES: To determine the prevalence of myocardial depression and its effect on the clinical severity in patients with dengue hemorrhagic fever. DESIGN: Clinical study. SETTING: King Chulalongkorn Memorial Hospital, Bangkok, Thailand. PATIENTS: Ninety-one children (age 10.5 +/- 2.9 yrs, male/female = 52/39) with serologically or polymerase chain reaction-proven dengue virus infection. INTERVENTIONS: Left ventricular ejection fraction (EF) was measured. The proportions of patients with EF <50% were identified in patients with dengue fever (DF, n = 30), dengue hemorrhagic fever without shock (DHF, n = 36), and dengue shock syndrome (DSS, n = 25). Comparisons of clinical findings were made among DSS patients with depressed ventricular function (EF <50%), fair ventricular function (EF > or =50% and <60%), and good ventricular function (EF > or = 60%). Serum troponin T was analyzed in nine patients. MEASUREMENTS AND MAIN RESULTS: EF during toxic stage was significantly lower in patients with DSS than DHF, and lower in DHF than DF (p = .05) with rapid recovery within 24-48 hrs. EF <50% was found in 6.7%, 13.8%, and 36% of patients with DF, DHF, and DSS during the toxic stage, respectively (p = .01). DSS patients with poor ventricular function had significantly more tachycardia and hepatomegaly. While end-diastolic volumes were similarly reduced, patients with lower EF tended to have lower cardiac output, required more aggressive intravenous fluid resuscitation, developed larger pleural effusion, and had higher incidence of respiratory embarrassment. No patient had elevated troponin T level. CONCLUSIONS: Transient myocardial depression is not uncommon in patients with DSS. Cardiac dysfunction in children with DSS may contribute to the clinical severity and the degree of fluid overload in these patients.


Asunto(s)
Cardiomiopatías/epidemiología , Cardiomiopatías/virología , Dengue Grave/fisiopatología , Disfunción Ventricular Izquierda/epidemiología , Adolescente , Cardiomiopatías/diagnóstico , Niño , Femenino , Humanos , Masculino , Prevalencia , Índice de Severidad de la Enfermedad , Tailandia/epidemiología , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/virología
19.
J Med Assoc Thai ; 89(9): 1420-6, 2006 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17100379

RESUMEN

BACKGROUND: Children with single ventricle physiology comprise 10% of all children with congenital heart disease (CHD) and one-third of children with cyanotic CHD seen at King Chulalongkorn Memorial Hospital. The prognosis of these children is generally thought to be poor but no study of the outcome has previously been done in this hospital and in Thailand. OBJECTIVES: To study the clinical course and outcome of children with single ventricle physiology at King Chulalongkorn Memorial Hospital during the current era. MATERIAL AND METHOD: One hundred and seventeen patients with single ventricle physiology were initially seen at this hospital during the year 1999-2001. Retrospective chart reviews were carried out in 90 children with available medical records. The status of the patients was determined in 2003 at clinic visits, by phone calls and mail. RESULTS: The main diagnoses were tricuspid atresia (TA, n = 10), pulmonary atresia with intact ventricular septum (PA/IVS, n = 16), single ventricle associated with cardiac malposition or heterotaxy syndrome (malposition, n = 35), hypoplastic left heart syndrome (HLHS, n = 11) and other complex single ventricle (others, n = 18). Most children did not have other major anomalies. Survival of patients with TA and PA/IVS was approximately 92 and 87% at 1 and 4 years, respectively. For patients in the other three groups, 1 and 4 year survival was 69 and 42%, respectively. Patients with HLHS had the worse survival, partly because of decisions not to pursue further treatments by the parents. Among HLHS patients who underwent Norwood procedure, the 1 and 4 year survival were 83% and 42%, respectively. Approximately 40 and 90% of all patients underwent heart surgery at 1 and 4 years follow-up, respectively. CONCLUSION: Despite limited resource, the short-term outcome of Thai children with single morphologic left ventricle (TA and PA/IVS) is reasonably good. Timely evaluation and treatment of these children toward Fontan procedure should be ensured. After proper discussion with the parents, palliative care is still acceptable for patients with single morphologic right ventricle or other complex single ventricle due to poor survival in the current era. As access to health care improves, re-evaluation of these outcomes is necessary to find the best strategy for the management of these patients.


Asunto(s)
Procedimiento de Fontan , Cardiopatías Congénitas/cirugía , Ventrículos Cardíacos/anomalías , Niño , Preescolar , Femenino , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/mortalidad , Ventrículos Cardíacos/cirugía , Hospitales , Humanos , Lactante , Recién Nacido , Masculino , Estudios Retrospectivos , Análisis de Supervivencia , Tailandia , Resultado del Tratamiento
20.
Indian Heart J ; 58(4): 315-20, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-19039147

RESUMEN

OBJECTIVES: Our purpose was to evaluate self-expanding nanoplatinum-coated nitinol devices for transcatheter closure of atrial septal defects and patent ductus arteriosus in a swine model. The devices were braided from platinum-activated nitinol wires and filled with polyester to enhance thrombogenicity. The platinum activation of the nitinol wires was carried out with the help of Nanofusion technology. The coating of platinum covers the exposed surface of the nitinol wires and prevents the release of nickel into the blood stream after the implantation of the device but does not affect its shape memory, which makes the device self-expanding after it is loaded from the catheter. METHODS AND RESULTS: Atrial septal defects were created in 12 piglets by balloon dilation of the patent foramen ovale. The size of the device was selected on the basis of the diameter of the balloon and the size of the defect, measured by transthoracic echocardiography. The devices were successfully deployed in all 12 piglets under fluoroscopic study. Transthoracic color Doppler echocardiograms showed complete closure of the atrial septal defect within 15 minutes of device implantation. Twelve patent ductus arteriosus closure devices were deployed in the right or left subclavian arteries in 10 piglets. Angiograms showed complete occlusion of the subclavian arteries within a few minutes of device deployment. In the atrial septal defect cases, the autopsy findings showed complete organizing fibrin thrombus formation and complete neo-endothelialization on the outer surface of the devices within one week and six weeks of implantation, respectively. CONCLUSION: The use of self-expanding nanoplatinum-coated nitinol devices for the transcatheter closure of atrial septal defects and patent ductus arteriosus is feasible. The excellent occlusion result and complete neo-endothelialization of the devices in the swine model is an indication of the potential of these devices in human application.


Asunto(s)
Cateterismo/instrumentación , Foramen Oval Permeable/terapia , Defectos del Tabique Interatrial/terapia , Prótesis e Implantes , Aleaciones , Animales , Angiografía Coronaria , Conducto Arterioso Permeable/diagnóstico por imagen , Conducto Arterioso Permeable/terapia , Ecocardiografía Transesofágica , Foramen Oval Permeable/diagnóstico por imagen , Defectos del Tabique Interatrial/diagnóstico por imagen , Nanotecnología , Diseño de Prótesis , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...