Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 30
1.
Article En | MEDLINE | ID: mdl-38700962

In this paper, a high gain amplifier with phase compensation loop is presented. A structure of parallel gate cross-coupled transistors to both ends of differential pair drain and source is designed to improves the load impedance, which obtains sufficient gain and further reduces power consumption. A novel capacitor bootstrap load circuit is proposed. The capacitor bootstrap topology is constructed by the drain source resistance of the transistor working in the cut-off region, where the gate source parasitic capacitor of the transistor is in parallel with the bootstrap capacitor rather than the existing series structure, thereby only a small bootstrap capacitor is required. By avoiding the use of large capacitors, chip area can be effectively reduced without compromising performance such as gain and bandwidth. The amplifier is fabricated using 10-µm n-type a-IGZO TFT technology. Measurement results show that the proposed amplifier achieves a voltage gain of 43.5dB and a common mode rejection ratio of 61.2dB while maintaining low power consumption. The amplifier also exhibits a -3dB bandwidth covering 0.4~2.1KHz, encompassing major bioelectric frequency bands. A real-time ECG signal was successfully captured using the fabricated TFT amplifier and gel electrodes. It has great potential in flexible sensing and acquisition applications such as electro cardiogram (ECG), electro encephalogram (EEG), pulse detection, and other wearable applications.

2.
Article En | MEDLINE | ID: mdl-38689530

Recently, concern has been raised about the spread of human mpox virus, and the demand for rapid detection reagents for mpox virus has increased. This study aims to establish a time-resolved fluorescence immunochromatography (TRFICO) method for qualitative/quantitative detection of mpox virus. A double-antibody sandwich TRFICO method was optimized and established using mpox recombinant fusion antigen and its paired monoclonal antibody. The test performance of the method was evaluated using mpox fusion antigen and control serum, including sensitivity, linearity range, specificity, precision, and reference interval. We successfully established a TRFICO method for qualitative/quantitative detection of mpox antigen, its linearity range 0-100 ng/mL, analytical sensitivity 0.017 ng/mL, and reference intervals greater than 0.045 ng/mL. No cross-reaction was detected with various poxvirus and clinical negative controls, with good specificity. All average recoveries of the intra- and inter-batch ranged from 81.33% to 97.83%, and all CVs were below 10%. Additionally, the TRFICO strips can be stably stored at 37°C for 7 days without significant changes in the fluorescence intensity. This TRFICO method, with high sensitivity, linearity range, specificity, precision, and stability with 16-min detection time, provides a new option for qualitative/quantitative and convenient testing of mpox virus.

3.
Mikrochim Acta ; 191(6): 325, 2024 05 13.
Article En | MEDLINE | ID: mdl-38739279

Glial fibrillary acidic protein (GFAP) in serum has been shown as a biomarker of traumatic brain injury (TBI) which is a significant global public health concern. Accurate and rapid detection of serum GFAP is critical for TBI diagnosis. In this study, a time-resolved fluorescence immunochromatographic test strip (TRFIS) was proposed for the quantitative detection of serum GFAP. This TRFIS possessed excellent linearity ranging from 0.05 to 2.5 ng/mL for the detection of serum GFAP and displayed good linearity (Y = 598723X + 797198, R2 = 0.99), with the lowest detection limit of 16 pg/mL. This TRFIS allowed for quantitative detection of serum GFAP within 15 min and showed high specificity. The intra-batch coefficient of variation (CV) and the inter-batch CV were both < 4.0%. Additionally, this TRFIS was applied to detect GFAP in the serum samples from healthy donors and patients with cerebral hemorrhage, and the results of TRFIS could efficiently discern the patients with cerebral hemorrhage from the healthy donors. Our developed TRFIS has the characteristics of high sensitivity, high accuracy, and a wide linear range and is suitable for rapid and quantitative determination of serum GFAP on-site.


Chromatography, Affinity , Glial Fibrillary Acidic Protein , Limit of Detection , Glial Fibrillary Acidic Protein/blood , Humans , Chromatography, Affinity/methods , Reagent Strips , Cerebral Hemorrhage/blood , Cerebral Hemorrhage/diagnosis , Biomarkers/blood
4.
Virol J ; 21(1): 64, 2024 03 11.
Article En | MEDLINE | ID: mdl-38468354

OBJECTIVE: Canine enteric coronavirus (CCV) and canine parvovirus type 2 (CPV-2) are the main pathogens responsible for acute gastroenteritis in dogs, and both single and mixed infections are common. This study aimed to establish a double-labeling time-resolved fluorescence immunoassay (TRFIA) to test and distinguish CCV and CPV-2 diseases. METHODS: A sandwich double-labeling TRFIA method was established and optimized using europium(III) (Eu3+)/samarium(III) (Sm3+) chelates. CCV/CPV-2 antigens were first captured by the immobilized antibodies. Then, combined with Eu3+/Sm3+-labeled paired antibodies, the Eu3+/Sm3+ fluorescence values were detected after dissociation to calculate the CCV/CPV-2 ratios. The performance, clinical performance and methodology used for laboratory (sensitivity, specificity, accuracy and stability) testing were evaluated. RESULTS: A double-label TRFIA for CCV and CPV-2 detection was optimized and established. The sensitivity of this TRFIA kit was 0.51 ng/mL for CCV and 0.80 ng/mL for CPV-2, with high specificity for CCV and CPV-2. All the accuracy data were less than 10%, and the recovery ranged from 101.21 to 110.28%. The kits can be temporarily stored for 20 days at 4 °C and can be stored for 12 months at temperatures less than - 20 °C. Based on a methodology comparison of 137 clinically suspected patients, there was no statistically significant difference between the TRFIA kit and the PCR method. Additionally, for CCV detection, the clinical sensitivity was 95.74%, and the clinical specificity was 93.33%. For CPV-2 detection, the clinical sensitivity was 92.86%, and the clinical specificity was 96.97%. CONCLUSION: In this study, a double-label TRFIA kit was prepared for CCV and CPV-2 detection with high laboratory sensitivity, specificity, accuracy, stability, clinical sensitivity and specificity. This kit provides a new option for screening/distinguishing between CCV and CPV-2 and may help improve strategies to prevent and control animal infectious diseases in the future.


Coronavirus, Canine , Dog Diseases , Parvoviridae Infections , Parvovirus, Canine , Humans , Animals , Dogs , Parvoviridae Infections/diagnosis , Parvoviridae Infections/veterinary , Sensitivity and Specificity , Immunoassay , Dog Diseases/diagnosis
5.
Pract Lab Med ; 38: e00356, 2024 Jan.
Article En | MEDLINE | ID: mdl-38292924

Objective: Abnormal serum matrix metalloproteinase-9 (MMP-9) levels are closely related to the occurrence and development of many diseases. This study aimed to establish a fluorescence immunochromatography (FIC) method using the lanthanide fluorescent element europium(III) (Eu3+) for the quantitative measurement of MMP-9 in serum. Design & Methods: The FIC method for quantifying MMP-9 was optimized and established, and the FIC test strips (FICTS) were assembled and subsequently evaluated for sensitivity, specificity and precision. Furthermore, the reference interval and clinical sensitivity/specificity were estimated using clinical healthy/positive serum samples, and a commercial ELISA was used for comparison. Results: We successfully established an FIC method and prepared FICTS. The analytical sensitivity of the FICTS was 0.92 ng/mL, with a linearity range of 0-1000 ng/mL. The cross-reactivity of the 7 common serum interferents was less than 1.56%. All recoveries of the intra-array and inter-array samples ranged from 102.50% to 110.99%, and all CVs were less than 5%. The reference interval of the FICTS was >161.15 ng/mL. The clinical sensitivity was 96.00%, and the specificity was 97.5%. The results of 270 clinical serum samples were highly coincident with the clinical diagnostic results. Pearson correlation analysis and Bland‒Altman plots indicated that the FICTS and commercial ELISA results were consistent with the quantitative MMP-9 concentration. Conclusions: The designed FIC method and test strips may be suitable for point-of-care quantitative measurement of MMP-9, which provides a new method for screening for atherosclerosis, xerophthalmia, etc.

6.
BMC Biotechnol ; 23(1): 30, 2023 08 18.
Article En | MEDLINE | ID: mdl-37596558

BACKGROUND: Carbohydrate antigen 724 (CA724) is a sensitive and specific indicator for multiple malignant tumors. The aim of this study was to establish a Eu-time resolved fluorescence immunochromatography (Eu-TRFICO) method for quantitative detection of CA724 in serum. METHODS: Eu-TRFICO strips were optimized and assembled. The sensitivity, specificity and precision were evaluated using CA724 standard dilutions and matrix serum. Meanwhile, the reference interval, comparison, and sensitivity/specificity were performed using clinical negative/positive gastric cancer serum samples. RESULTS: The standard curve equation was y = 9.869 x - 154.12 (R2 = 0.993), and the sensitivity was 0.42 U/mL. The common interferents in serum could not affect the quantitative results with low cross-reactivities (all no more than 1.09%). All average recoveries of the intra- and interbatch ranged from 102.38 to 106.40%, and all CVs were below 10%. The reference interval of the healthy subjects was < 4.68 U/mL and the reference interval of the subjects with grade I/II gastric cancer was > 9.54 U/mL. Additionally, a high Pearson r (0.9503) and sensitivity/specificity (92.86%/94.20%) were obtained. CONCLUSION: This study prepared Eu-TRFICO strips with high sensitivity, specificity, precision and satisfactory clinical testing performance, which provides more options for clinical quantitative and convenient testing of CA724.


Stomach Neoplasms , Humans , Stomach Neoplasms/diagnosis , Chromatography, Affinity , Immunologic Tests
7.
J Immunol Methods ; 520: 113513, 2023 09.
Article En | MEDLINE | ID: mdl-37307908

Echinococcosis is a kind of parasitic disease shared by humans and animals. The aim of this study was to establish a new detection method for echinococcosis screening using magnetic bead-based chemiluminescence immunoassay (CLIA). A magnetic bead-based CLIA to determine anti-echinococcosis IgG antibodies was optimized and established. The sensitivity, accuracy, precision and recovery rate were evaluated using the national reference serum, and the reference interval, specificity and comparison assays were performed using the clinical negative/positive echinococcosis serum samples. This study established a new CLIA to determine anti-echinococcosis IgG antibodies. The sensitivity of this CLIA method was higher than that of the registered ELISA kit and the national standard, the conformance rate of the negative/positive references was 100% (8/8), the CVs of the sensitivity reference were all below 5%, and the CVs of the precision reference were 5.7%. There was no obvious cross-reactivity with the common parasitic disease-positive serum and serum interferents. Clinical sample testing found that the cutoff value of this CLIA was 5537.15 (RLU), and there was no significant difference between the CLIA method and the registered ELISA kit. This study established a fully automated CLIA method with high sensitivity, specificity, accuracy, precision, recovery rate, and satisfactory clinical testing performance, which may provide a new choice for echinococcosis screening.


Immunoglobulin G , Luminescence , Animals , Humans , Enzyme-Linked Immunosorbent Assay , Immunoassay/methods , Sensitivity and Specificity , Luminescent Measurements/methods
8.
Comput Math Methods Med ; 2022: 1704948, 2022.
Article En | MEDLINE | ID: mdl-35912162

Gastric carcinoma (GC) is one of the most common malignancies in the world with the great early screening challenges. The study is aimed at establishing a new detection method for early screening GC using time-resolved fluorescence immunoassay (TRFIA) via quantitative detection of gastrin-17 (G-17) and carbohydrate antigen 724 (CA724) in serum. Time-resolved analyzer measured the fluorescence intensity. The standards of G-17/CA724 were used for drawing the standard curve, which is used to calculate the concentration of G-17 and CA724 in serum sample. The sensitivity for G-17 was 0.54 pg/mL and for CA724 was 0.28 U/mL with a wide-range analyze concentration (0.1-1000) pg/mL or U/mL. The average recoveries ranged from 100.52% to 110.30% for G-17 and 103.02% to 116.00% for CA724. All CVs of the intra- and interassay were below 10% with high specificity. There was a high Pearson coefficient between this TRFIA method and the commercially available kits (Pearson r 0.9117 for G-17 and 0.9449 for CA724). Additionally, the cutoff value was 88.41 pg/mL and 5.47 U/mL for CA724 in health subjects. This study established a TRFIA method for simultaneous detection of the concentrations of G-17 and CA724 in serum, which provide a new method for sensitive, accurate, and specific early screening of gastric cancer.


Stomach Neoplasms , Biomarkers, Tumor , Early Detection of Cancer , Humans , Immunoassay , Mass Screening , Sensitivity and Specificity , Stomach Neoplasms/diagnostic imaging
9.
Biotechnol Appl Biochem ; 69(6): 2617-2623, 2022 Dec.
Article En | MEDLINE | ID: mdl-34981870

Elevated serum high-sensitivity C-reactive protein (hs-CRP) and lipoprotein(a) (Lp(a)) levels are associated with the development of native coronary atherosclerosis. We aimed to establish a new method for the simultaneous detection of hs-CRP and Lp(a) to predict the development of atherosclerosis. A one-step time-resolved fluorescence immunoassay (TRFIA) with europium(III) (Eu3+ ) or samarium(III) (Sm3+ ) labels was established, and the performance of this TRFIA (in terms of sensitivity, specificity, accuracy, and cutoff values) was evaluated using clinical serum samples and compared with those of registered kits. The sensitivity was 0.052 µg/ml for hs-CRP and 0.64 µg/ml for Lp(a). The intra-assay and inter-assay cross-reactivities (CVs) were very low, ranging from 2.05% to 4.67% for hs-CRP and from 2.42% to 6.43% for Lp(a). The CVs were very low (<0.34% and <2.65%, respectively) with five interferents. Additionally, there was a high Pearson coefficient between the present TRFIA method and the registered kits (R2 = 0.9967 and 0.9906, respectively). These data indicate that this study developed a TRFIA method that can be used for the quantitative detection of hs-CRP and Lp(a) in serum with high sensitivity, specificity, and accuracy. This TRFIA provides a new method for predicting the development of atherosclerosis.


Atherosclerosis , Coronary Artery Disease , Humans , C-Reactive Protein , Lipoprotein(a) , Fluoroimmunoassay/methods , Sensitivity and Specificity
10.
Biotechnol Appl Biochem ; 69(4): 1474-1481, 2022 Aug.
Article En | MEDLINE | ID: mdl-34245473

Coronavirus disease 2019 (COVID-19) caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is spreading rapidly around the world. Antibody detection plays an important role in the diagnosis of COVID-19. Here, we established a new time-resolved fluorescence immunoassay (TRFIA) to determine COVID-19 total antibodies. A double-antigen sandwich TRFIA was optimized and established: recombinant nucleocapsid phosphoprotein (N protein) and spike protein (S protein) of COVID-19 immobilized on 96-well plates captured human COVID-19 antibodies and then banded together with the N/S proteins labeled with europium(III) (Eu3+ ) chelates, and finally, time-resolved fluorometry was used to measure the fluorescence values. We successfully established a TRFIA method for the detection of human COVID-19 total antibodies, and the cutoff value was 2.02. There was no cross-reactivity with the negative reference of the National Reference Panel for IgM and IgG antibodies to COVID-19. The CV of the precision assay was 3.19%, and the assay could be stored stably for 15 days at 37°C. Compared with that of the colloidal gold method and chemiluminescence method, the sensitivity of the TRFIA method was higher, and the false positive/negative rate was lower. This established TRFIA has high sensitivity, accuracy, and specificity, which indicates that this method provides a new detection method for the high-throughput routine diagnosis of COVID-19.


COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , Fluoroimmunoassay/methods , Humans , Immunoassay/methods , Immunoglobulin G , Sensitivity and Specificity
11.
J Fluoresc ; 31(6): 1771-1777, 2021 Nov.
Article En | MEDLINE | ID: mdl-34495467

Currently, atherosclerosis accounts for the majority of cardiovascular morbidity and mortality worldwide, and predicting the stability of atherosclerotic plaque is the main method to prevent atherosclerotic death. This study aims to establish a dual-label time-resolved fluorescence immunoassay (TRFIA) of matrix metalloprotein-9 (MMP-9) and lipoprotein-associated phospholipaseA2 (Lp-PLA2) to predict atherosclerotic plaque stability. A dual-label TRFIA was introduced for the simultaneous quantification of MMP-9 and Lp-PLA2 using fluorescent lanthanide (Eu3+ and Sm3+) chelates. The performance (sensitivity, specificity, accuracy, precision and reference intervals in different subjects) of this TRFIA was evaluated and compared with commercial kit. The sensitivity of the TRFIA for MMP-9 was 0.85 ng/mL and for Lp-PLA2 was 0.68 ng/mL with high affinity and specificity. The average recoveries were 94.58% to 109.82%, and 104.32% to 109.26%, respectively. All intra- and inter-assay CVs ranged from 3.10% to 5.46%. For the normal subjects, the cutoff value was 160.70 ng/mL for MMP-9 and 183.73 ng/mL for LP-PLA2; for the subjects with stable plaque, the cutoff value was 181.98~309.22 ng/mL for MMP-9 and 194.73~337.89 ng/mL for LP-PLA2; for the subjects with unstable plaque, the cutoff value was 330.43 ng/mL for MMP-9 and 343.23 ng/mL for LP-PLA2. This TRFIA detection results agreed well with the results of commercial kit (R2=0.9567 and R2=0.9771, respectively) in clinical serum samples. The TRFIA developed has a wide detection range and good sensitivity for the high-throughput simultaneous detection of MMP-9 and Lp-PLA2 in serum, which provides a new method for predicting the stability of atherosclerotic plaque.


1-Alkyl-2-acetylglycerophosphocholine Esterase/blood , Fluoroimmunoassay , Matrix Metalloproteinase 9/blood , 1-Alkyl-2-acetylglycerophosphocholine Esterase/metabolism , Europium/chemistry , Humans , Matrix Metalloproteinase 9/metabolism , Samarium/chemistry , Time Factors
12.
J Fluoresc ; 31(5): 1291-1296, 2021 Sep.
Article En | MEDLINE | ID: mdl-34075517

African swine fever (ASF) has severely influenced the swine industry of the whole world. Fast and accurate African swine fever virus (ASFV) antigen detection is very important for ASF prevention. This study aims to establish a new detection method for detection ASFV antigen using time-resolved fluorescence immunoassay (TRFIA) in the nose and mouth discharge. A double antibody sandwich TRFIA method was optimized and established. Recombinant P30 recombinant antigen was captured by its antibodies immobilized on 96-well plate, and then banded together with another detection antibodies labeled with Europium(III) (Eu3+) chelates, finally time-resolved analyzer measured the fluorescence intensity. The performance of this TRFIA (sensitivity, specificity and accuracy) was evaluated using the clinical samples and compared with the nucleic acid testing method. The sensitivity of this TRFIA was 0.015 ng/mL (dynamic range 0.24-500 ng/mL) with high specificity. The recovery ranged from 92.00 to 103.62 %, the inter-assay CVs ranged from 5.50 to 11.96 %, and the intra-assay CVs was between 5.20 and 10.53 %. Additionally, the cutoff value was 0.016. TRFIA took only 45 min to generate results, and its detection capability comparable to the nucleic acid detection. This study developed a TRFIA method that could be used for qualitative/quantitative detection of ASFV antigen in pigs nasal discharge, which has high sensitivity, specificity and accuracy. This TRFIA provides a new method for rapidly screening ASFV infection in pigs industry.


African Swine Fever Virus , Fluorescence , Animals , Swine
13.
Biotechnol Appl Biochem ; 68(3): 597-602, 2021 Jun.
Article En | MEDLINE | ID: mdl-32533780

As a highly contagious and potentially fatal disease of dogs, canine parvovirus type 2 (CPV-2) usually causes severe myocarditis and gastroenteritis, while vaccine injection has greatly reduced the incidence of CPV-2 diseases. However, there is currently a lack of simple and effective method for quantitative detection of CPV-2 in vaccine. Therefore, this study aims to prepare an accurate method to determine the CPV-2 antigen (CPV-2-Ag) in vaccine. Here, a sandwich time-resolved fluorescence immunoassay (TRFIA) was established and optimized. Anti-CPV-2 antibodies were immobilized on 96-well plates to capture CPV-2-Ag, and then bound together with the detection antibodies labeled with Europium(III) (Eu3+ ) chelates; finally, time-resolved fluorometry was employed to measure the fluorescence intensity. Vaccination was performed to evaluate the relationship between CPV-2-Ag concentration and antibody titer. The sensitivity is 1.15 mEU/mL (LogY = 1.524 + 0.8667 × LogX, R2  = 0.9933), and the average recovery is among 91.00% to 106.39% without cross-reactions with the other canine viral antigen. The correlation between ELISA assay and this method is up to 0.9861. And, there is high correlation between the CPV-2-Ag concentration and antibody titers (R2  = 0.9234). This immunoassay established has high sensitivity, accuracy, and specificity, which indicate that this method could be suitable for quantitative detection of CPV-2-Ag in vaccine evaluation.


Antigens, Viral/analysis , Fluoroimmunoassay , Parvovirus, Canine/isolation & purification , Viral Vaccines/immunology , Animals , Antibodies, Viral/immunology , Antigens, Viral/immunology , Dogs , Enzyme-Linked Immunosorbent Assay , Parvovirus, Canine/immunology , Vaccination
14.
Int J Clin Exp Pathol ; 13(5): 889-895, 2020.
Article En | MEDLINE | ID: mdl-32509059

OBJECTIVE: To explore the effects of miR-149 on the cell proliferation and apoptosis of colorectal cancer (CRC) and its potential molecular mechanism. METHODS: miR-149 expression patterns were detected in human CRC cell lines by quantitative real-time RT-PCR (Q-PCR). Online prediction software and luciferase reporter assay were performed to screen the functional targets of miR-149. CRC cells were transfected with miR-149 mimics or siRNAs of FZD5 and then divided into NC group (negative control), miR-149 mimics group (cells transfected with miR-149 mimics) and miR-149 mimics + SiFZD5 group (cells transfected by miR-149 mimics and SiFZD5). Moreover, the effects of miR-149 on the proliferation and apoptosis of CRC cells were also analyzed by MTT and flow cytometry assay. In addition, the expression of Wnt/ß-catenin signal pathways related factors were shown by western blot analysis. RESULTS: Q-PCR results demonstrated that the expression of miR-149 was significantly lower in SW480 than that in the FHC cell line. Frizzled class receptor 5 (FZD5) was identified as a functional target of miR-149 through a series of experiments including Q-PCR, western blot analysis, and luciferase assay. Cellular functional experiments demonstrated that the cell viability and proliferation were greatly inhibited after miR-149 overexpression in SW480 cells. Furthermore, the proportion of apoptotic cells increased significantly after introducing miR-149 into SW480 cells. Furthermore, Wnt/ß-catenin signal pathway was activated because of the lower expression of ß-catenin and cyclinD1 in miR-149 mimics group. However, reducing FZD5 expression restored the expression of ß-catenin and cyclin D. CONCLUSIONS: Our data suggested that miR-149 may function as a tumor suppressor in CRC cells lines by targeting FZD5. miR-149/FZD5 may become a new therapeutic target for CRC.

15.
Curr Pharm Biotechnol ; 21(11): 1099-1106, 2020.
Article En | MEDLINE | ID: mdl-32188382

BACKGROUND: Chlorogenic Acid (CA) has diverse, recognized health effects. OBJECTIVE: This study aimed to explore the effects of CA on fat reduction and the underlying mechanism of these effects. MATERIALS AND METHODS: First, we established a Monosodium Glutamate (MSG)-induced obesity mouse model and subjected the mice to 4 weeks of CA gavage. Then, we established an oleic acidinduced model of human fatty liver in HepG2 cells, and administered a CA intervention to the cells for 48 h. Finally, we used Oil red O staining, biochemical detection kits, RT-PCR and Western blot analysis to evaluate the effects of CA on fat reduction and on related pathways. RESULTS: The CA treatment could reduce fat accumulation in the liver and reduce blood lipid levels. In addition, CA decreased the mRNA and protein levels of peroxisome proliferator-activated receptor gamma, coactivator 1 α (PGC-1α) and Uncoupling Protein 1 (UCP1) in the MSG-induced obesity mouse model and the oleic acid-induced HepG2 cells. CONCLUSION: Based on the above results, we deduced that CA could reduce body weight and fat deposition in vitro and in vivo and that the mechanism may be related to the PGC-1α/UCP-1 pathway. CA can be developed as a drug to lower blood lipids and to treat obesity.


Anti-Obesity Agents/pharmacology , Chlorogenic Acid/pharmacology , Fatty Liver/drug therapy , Liver/drug effects , Obesity/drug therapy , Weight Loss/drug effects , Animals , Anti-Obesity Agents/therapeutic use , Chlorogenic Acid/therapeutic use , Disease Models, Animal , Fatty Liver/metabolism , Hep G2 Cells , Humans , Lipid Metabolism/drug effects , Lipids/blood , Liver/metabolism , Mice , Mice, Inbred C57BL , Obesity/metabolism , Peroxisome Proliferator-Activated Receptor Gamma Coactivator 1-alpha/metabolism , Signal Transduction/drug effects , Sodium Glutamate/metabolism , Uncoupling Protein 1/metabolism
16.
J Cell Physiol ; 235(4): 3579-3591, 2020 04.
Article En | MEDLINE | ID: mdl-31552684

HOXC10 plays a critical role in many cellular processes, such as proliferation, migration, and invasion, but the function of HOXC10 in gastric carcinoma is not clear. In this study, we aimed to investigate the expression profile of HOXC10 and its role in gastric carcinoma cells and in vivo experiments. HOXC10 expression patterns were detected in clinical samples and gastric cancer cells lines by reverse transcriptase polymerase chain reaction assays, and then, we focused on its role in regulating cell proliferation, cell cycle, migration, and invasion after transfection of silencing and overexpression plasmids in vitro and in vivo. Finally, we confirmed the correlation between HOXC10 and nuclear factor-κB (NF-κB), tumor necrosis factor-α (TNF-α), transforming growth factor-ß (TGF-ß), and epidermal growth factor receptor expression. We found that HOXC10 expression increased in clinical samples, especially in poorly differentiated (PD) gastric cancer cells. Silencing HOXC10 suppressed proliferation, migration, and invasion in vitro, and inhibited tumor growth and induced apoptosis in vivo. Overexpression of HOXC10 showed the opposite effect on PD gastric cancer cells. In addition, silencing HOXC10 inhibited the expression of interleukin-6, TNF-α, TGF-ß, and epidermal growth factor, and overexpressing HOXC10 induced their expression both in vitro and in vivo. Luciferase reporter assays and chromatin immunoprecipitation indicated that HOXC10 may activate the NF-κB signaling pathway through regulation of P65 transcriptional activity by binding to the P65 promoter. HOXC10 may play an important role in PD gastric carcinoma cell proliferation, cell cycle, migration, invasion, and metastasis through upregulating proinflammatory cytokines via NF-κB pathway, suggesting HOXC10 may serve as a novel therapeutic target for PD gastric cancer.


Carcinoma/genetics , Cell Proliferation/genetics , Homeodomain Proteins/genetics , Stomach Neoplasms/genetics , Animals , Carcinoma/pathology , Cell Line, Tumor , Cell Movement/genetics , Cytokines/genetics , Female , Gene Expression Regulation, Neoplastic/genetics , Heterografts , Humans , Interleukin-6/genetics , Lymphotoxin-alpha/genetics , Male , Mice , Neoplasm Invasiveness/genetics , Neoplasm Invasiveness/pathology , Stomach Neoplasms/pathology , Tumor Necrosis Factor-alpha/genetics
17.
Exp Ther Med ; 18(4): 3053-3061, 2019 Oct.
Article En | MEDLINE | ID: mdl-31572545

Astragaloside IV (ASI) exhibits a wide variety of pharmacological effects in cardiovascular diseases, hepatitis and kidney disease and due to this, ASI has recently become an attractive research target. The present study aimed to determine the effect of ASI on renal fibrosis and the mechanisms underlying its therapeutic effects in diabetic nephropathy (DN). In vitro, ASI was added to rat mesangial cells (RMCs) and cultured with a high level of glucose (HG) to observe the effects exhibited on proliferation and fibrosis-related mRNA and protein expression. In vivo, a DN model was established using streptozotocin administration in rats, and renal injury was evaluated using renal histological examination. The expression levels of related mRNAs and proteins were analyzed using reverse transcription-quantitative PCR, western blot analysis and immunohistochemistry. ASI was demonstrated to downregulate miR-192 expression and inhibit excessive proliferation of RMCs, which was induced by HG, in a dose-dependent manner. Additionally, ASI exhibited a therapeutic effect on DN rats. ASI was also demonstrated to decrease the miR-192 expression and mRNA and protein expression of transforming growth factor-ß1 (TGF-ß1), Smad3, α-smooth muscle actin (α-SMA) and collagen type 1 (col1), and increase the mRNA and protein expression of Smad7 in vitro and in vivo. These results suggested that ASI exhibited a therapeutic effect on DN, possibly due to the inhibition of excessive mesangial proliferation and renal fibrosis via the TGF-ß1/Smad/miR-192 signaling pathway.

18.
Cancer Med ; 8(16): 7044-7054, 2019 11.
Article En | MEDLINE | ID: mdl-31557409

BACKGROUND: Immunotherapy and its mechanisms are being studied in a wide variety of cancers. Programmed cell death ligand 1 (PDL1) is associated with immune evasion in numerous tumor types. Here, we aimed to assess the relationship between metastasis associated in colon cancer-1 (MACC1) and PDL1 and examine their effects on gastric cancer (GC) tumor immunity. METHODS: The expression of MACC1, c-Met, and PDL1 in human GC tissues was first assessed using quantitative RT-PCR (qRT-PCR) and immunohistochemistry. We then focused on the relationships among MACC1, c-Met, and PDL1 using RT-PCR and western blotting after cell transfection and inhibitor treatment in vitro and on the identification of their roles in immune killing in vitro and in vivo. RESULTS: We found that expression of MACC1, c-Met, and PDL1 was upregulated in human GC tissues, and there was a positive correlation between the expression levels. In addition, we found that ectopic expression of MACC1 (silencing and overexpression by transfection) resulted in corresponding changes in c-Met and PDL1 expression levels, and c-Met/AKT/mTOR pathway inhibitors (SU11274, MK2206, and rapamycin) blocked the regulation of PDL1 expression by MACC1. Furthermore, silencing of MACC1 led to an increase in antitumor and immune killing in vitro and in vivo, and overexpression of MACC1 resulted in a decrease in tumor immunity in vitro and in vivo. CONCLUSIONS: From these data, we infer that MACC1 regulates PDL1 expression and tumor immunity through the c-Met/AKT/mTOR pathway in GC cells and suggest that MACC1 may be a therapeutic target for GC immunotherapy.


B7-H1 Antigen/metabolism , Proto-Oncogene Proteins c-akt/metabolism , Proto-Oncogene Proteins c-met/metabolism , Stomach Neoplasms/metabolism , TOR Serine-Threonine Kinases/metabolism , Trans-Activators/metabolism , Animals , B7-H1 Antigen/genetics , Cell Line, Tumor , Cytokines/immunology , Female , Humans , Leukocytes, Mononuclear/metabolism , Male , Mice, Nude , Middle Aged , Proto-Oncogene Proteins c-met/genetics , Signal Transduction , Stomach Neoplasms/genetics , Stomach Neoplasms/immunology , Stomach Neoplasms/pathology , Trans-Activators/genetics
19.
Biotechnol Appl Biochem ; 66(4): 586-590, 2019 Jul.
Article En | MEDLINE | ID: mdl-31039295

Canine parvovirus type 2 (CPV-2), as a highly contagious and potentially fatal disease of dogs and many other carnivores, usually causes severe gastroenteritis and myocarditis. Therefore, it is very necessary and urgent to have an accurate method to determine the CPV-2 antibodies (CPV-2-Ab) in canine samples. Here, a magnetic bead-based chemiluminescence immunoassay was established and optimized to detect the concentration of CPV-2-Ab in serum. And a commercial assay was also used to evaluate the consistency with our method. After optimization of the detective system, the CPV-2-Ab was captured by CPV-antigen-magnetic bead (8.3 µg/mL); then combined with the conjugation of anti-canine IgG antibody-acridinium ester (0.36 µg/mL). Finally, collected the signal (read the luminosity) after 1 H reaction time. The linear correlation coefficient (R2 ) is 0.9924. The limit of detection (sensitivity) is 0.36 ng/mL (the linear dynamic range: 1.32-93.75 ng/mL), and the average recovery is 100.89% without cross-reactions with other canine viral antibodies. The results' correlation between commercial assays and this method is 0.9888. This immunoassay establishes that it has high sensitivity, accuracy, and specificity in clinical analysis, indicating that this method could be suitable for quantitative detection of CPV-2-Ab and evaluation of vaccination effect.


Antibodies, Viral/blood , Antibodies, Viral/immunology , Enzyme-Linked Immunosorbent Assay , Luminescent Measurements , Parvovirus, Canine/immunology , Animals , Dogs , Magnetic Phenomena
20.
Biotechnol Appl Biochem ; 65(6): 816-821, 2018 Nov.
Article En | MEDLINE | ID: mdl-29679420

Among women worldwide, cervical cancer is the second-most common cancer, and cervical smears and DNA detection have low sensitivity or are too expensive. The concentrations of carcinoembryonic antigen (CEA) and squamous cell carcinoma (SCC) in the serum were detected using a sandwich immunoassay. The CEA and SCC in the serum were captured by anti-CEA and anti-SCC antibodies. After combining other anti-CEA- and anti-SCC-labeled antibodies with europium (III) (Eu3+ ) and samarium (III) (Sm3+ ) chelates, CEA and SCC were detected with time-resolved fluorometry (TRF). The linear correlation coefficients (R2 ) of the CEA and SCC standard curves were 0.9997 and 0.9997, respectively. The minimum detection level for CEA was 1.15 ng/mL (the linear dynamic range was 3.24-543.67 ng/mL), and the average recovery was 100.83%. The sensitivity for SCC detection was 0.54 ng/mL (the linear dynamic range was 2.47-96.58 ng/mL), and the average recovery was 101.02%. High R2 between the results of commercial assays and this method were obtained (R2  = 0.9983 for CEA, R2   = 0.9878 for SCC). These findings indicated that the dual-label TRFIA invented in this study has high sensitivity, accuracy, and specificity in clinical analysis, which indicates that this method could be used for the early diagnosis and follow-up surveillance of cervical cancer.


Antigens, Neoplasm/analysis , Carcinoembryonic Antigen/analysis , Fluoroimmunoassay/methods , Serpins/analysis , Uterine Cervical Neoplasms/diagnosis , Uterine Cervical Neoplasms/metabolism , Female , Fluorescence , Humans , Time Factors
...