Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Cardiovasc Electrophysiol ; 35(7): 1452-1460, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38757909

RESUMEN

INTRODUCTION: Left bundle branch area (LBBA) pacing (LBBAP) has been proposed as an alternative therapy option in patients indicated for cardiac pacing to treat bradycardia or heart failure. The aim of the study was to evaluate the safety and effectiveness of LBBAP in patients implanted with a Tendril 2088 stylet-driven lead. METHODS: The international retrospective data collection registry included 11 sites from 5 countries globally. Patients with attempted implants of the Tendril lead in the LBBA were followed for at least 6 months post the implant attempt. The primary safety and efficacy endpoints were freedom from LBBAP lead-related serious adverse events and the composite of LBBA capture threshold of ≤2.0 V and R-wave amplitudes ≥5 mV (or ≥value at implant), respectively. RESULTS: Of 221 patients with attempted implants of the Tendril 2088 lead in the LBBA, 91.4% (202/221) had successful implants for LBBAP. Regardless of the LBBAP implant success, all patients were followed for at least 6 months (8.7 ± 7.3 months). Baseline characteristics: 44% female, 84% ≥65 years old, 34% coronary artery disease, and 86% of primary indications for pacemaker implant. Both primary safety and effectiveness endpoints were met (freedom from LBBAP lead-related serious adverse device effects of 99.5% and electrical performance composite success rate of 93%). The capture thresholds in LBBAP at implant and 6 months were 0.8 ± 0.3 V@0.4 ± 0.1 ms and 0.8 ± 0.3 V@0.4 ± 0.1 ms. The rate of patients with capture threshold rise ≥1 V was 1.5% through 6 months. The R-wave amplitudes in LBBAP at implant and 6 months were 9.3 ± 3.2 mV and 10.6 ± 3.0 mV. CONCLUSIONS: This large multicenter study demonstrates that the stylet-driven Tendril™ STS 2088 lead is safe and effective for LBBAP with high success and low complication rates.


Asunto(s)
Potenciales de Acción , Estimulación Cardíaca Artificial , Frecuencia Cardíaca , Marcapaso Artificial , Sistema de Registros , Humanos , Femenino , Masculino , Anciano , Estudios Retrospectivos , Factores de Tiempo , Persona de Mediana Edad , Resultado del Tratamiento , Anciano de 80 o más Años , Bradicardia/fisiopatología , Bradicardia/terapia , Bradicardia/diagnóstico , Fascículo Atrioventricular/fisiopatología , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Factores de Riesgo , Diseño de Equipo
2.
Expert Opin Drug Metab Toxicol ; 16(9): 837-851, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32729743

RESUMEN

INTRODUCTION: Statins have been established as the standard of care for dyslipidemia and preventing cardiovascular diseases while posing few safety concerns. However, misconceptions about statin intolerance lead to their underuse, indicating a need to improve the understanding of the safety of this treatment. AREAS COVERED: We searched PubMed and reviewed literatures related to statin intolerance published between February 2015 and February 2020. Important large-scale or landmark studies published before 2015 were also cited as key evidence. EXPERT OPINION: Optimal lowering of low-density lipoprotein cholesterol with statins substantially reduces the risk of cardiovascular events. Muscle adverse events (AEs) were the most frequently reported AEs by statin users in clinical practice, but they usually occurred at a similar rate with statins and placebo in randomized controlled trials and had a spurious causal relationship with statin treatment. We proposed a rigorous definition for identifying true statin intolerance and present the criteria for defining different forms of muscle AEs and an algorithm for their management. True statin intolerance is uncommon, and every effort should be made to exclude false statin intolerance and ensure optimal use of statins. For the management of statin intolerance, statin-based approaches should be prioritized over non-statin approaches.


Asunto(s)
Dislipidemias/tratamiento farmacológico , Inhibidores de Hidroximetilglutaril-CoA Reductasas/administración & dosificación , Enfermedades Musculares/inducido químicamente , Algoritmos , Enfermedades Cardiovasculares/etiología , Enfermedades Cardiovasculares/prevención & control , LDL-Colesterol/sangre , Dislipidemias/complicaciones , Humanos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/efectos adversos , Enfermedades Musculares/diagnóstico
3.
Singapore Med J ; 58(7): 408-410, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28740998

RESUMEN

Therapeutic temperature management (TTM) was strongly recommended by the 2015 International Liaison Committee on Resuscitation as a component of post-resuscitation care. It has been known to be effective in improving the survival rate and neurologic functional outcome of patients after cardiac arrest. In an effort to increase local adoption of TTM as a standard of post-resuscitation care, this paper discusses and makes recommendations on the treatment for local providers.


Asunto(s)
Paro Cardíaco/terapia , Hipertermia Inducida , Adulto , Temperatura Corporal , Reanimación Cardiopulmonar , Paro Cardíaco/fisiopatología , Humanos , Hipertermia Inducida/efectos adversos , Hipertermia Inducida/métodos
4.
Singapore Med J ; 56(10): 580-5, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26512151

RESUMEN

Transvenous implantable cardioverter defibrillators are a type of implantable cardiac device. They are effective at reducing total and arrhythmic mortality in patients at risk of sudden cardiac death. Subcutaneous implantable cardioverter defibrillators (S-ICDs) are a new alternative that avoids the disadvantages of transvenous lead placement. In this case series, we report on the initial feasibility and safety of S-ICD implantation in Singapore.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/estadística & datos numéricos , Adulto , Electrofisiología , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Implantación de Prótesis , Singapur , Taquicardia Ventricular , Fibrilación Ventricular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...