Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 6 de 6
1.
Europace ; 25(9)2023 08 02.
Article En | MEDLINE | ID: mdl-37477946

AIMS: Intracardiac echocardiography (ICE) is a useful but operator-dependent tool for left atrial (LA) anatomical rendering during atrial fibrillation (AF) ablation. The CARTOSOUND FAM Module, a new deep learning (DL) imaging algorithm, has the potential to overcome this limitation. This study aims to evaluate feasibility of the algorithm compared to cardiac computed tomography (CT) in patients undergoing AF ablation. METHODS AND RESULTS: In 28 patients undergoing AF ablation, baseline patient information was recorded, and three-dimensional (3D) shells of LA body and anatomical structures [LA appendage/left superior pulmonary vein/left inferior pulmonary vein/right superior pulmonary vein/right inferior pulmonary vein (RIPV)] were reconstructed using the DL algorithm. The selected ultrasound frames were gated to end-expiration and max LA volume. Ostial diameters of these structures and carina-to-carina distance between left and right pulmonary veins were measured and compared with CT measurements. Anatomical accuracy of the DL algorithm was evaluated by three independent electrophysiologists using a three-anchor scale for LA anatomical structures and a five-anchor scale for LA body. Ablation-related characteristics were summarized. The algorithm generated 3D reconstruction of LA anatomies, and two-dimensional contours overlaid on ultrasound input frames. Average calculation time for LA reconstruction was 65 s. Mean ostial diameters and carina-to-carina distance were all comparable to CT without statistical significance. Ostial diameters and carina-to-carina distance also showed moderate to high correlation (r = 0.52-0.75) except for RIPV (r = 0.20). Qualitative ratings showed good agreement without between-rater differences. Average procedure time was 143.7 ± 43.7 min, with average radiofrequency time 31.6 ± 10.2 min. All patients achieved ablation success, and no immediate complications were observed. CONCLUSION: DL algorithm integration with ICE demonstrated considerable accuracy compared to CT and qualitative physician assessment. The feasibility of ICE with this algorithm can potentially further streamline AF ablation workflow.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Artificial Intelligence , Feasibility Studies , Echocardiography/methods , Heart Atria/diagnostic imaging , Heart Atria/surgery , Imaging, Three-Dimensional/methods , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Algorithms , Catheter Ablation/methods
2.
JACC Clin Electrophysiol ; 8(12): 1475-1483, 2022 12.
Article En | MEDLINE | ID: mdl-36543496

BACKGROUND: Although efficacious, catheter ablation (CA) of ventricular arrhythmias (VAs) originating from left ventricular (LV) papillary muscles (PAPs) has the potential to affect mitral valve (MV) function. OBJECTIVES: The aim of this study was to determine whether lesions delivered during CA of VAs from LV PAPs affected MV function. METHODS: Consecutive patients undergoing CA of LV PAP VAs from January 2015 to December 2020 in whom both preprocedural and postprocedural transthoracic echocardiography was performed were included. Radiofrequency ablation was performed with an irrigated-tip catheter with or without contact force sensing and intracardiac echocardiographic guidance. The PAPs were delineated into segments: tip, body, and base. Pre- and post-CA transthoracic echocardiograms were reviewed to assess MV regurgitation, which was graded 0 (none), 1 (mild), 2 (moderate), or 3 (severe). A change of ≥2 grades from baseline was considered significant. RESULTS: A total of 103 patients (mean age 63 ± 15 years, 78% men) were included. VAs were ablated from the anterolateral PAP in 35% (n = 36), posteromedial PAP in 55% (n = 57), and both PAPs in 10% (n = 10). Lesion distribution was as follows: PAP tip in 52 (50%), PAP base in 34 (33%), PAP body in 13 (13%), and entire PAP in 4 (4%). The mean number of lesions delivered was 16 ± 13 (median 14). Of 103 patients, 102 (99%) showed no change in MV function. CONCLUSIONS: Using intracardiac echocardiographic guidance, lesions can be safely delivered on various aspects of this structure without adverse impact on MV function.


Catheter Ablation , Tachycardia, Ventricular , Male , Humans , Middle Aged , Aged , Female , Papillary Muscles/diagnostic imaging , Papillary Muscles/surgery , Tachycardia, Ventricular/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Arrhythmias, Cardiac , Catheter Ablation/adverse effects
3.
Heart Rhythm O2 ; 2(3): 255-261, 2021 Jun.
Article En | MEDLINE | ID: mdl-34337576

BACKGROUND: Patients with typical atrial flutter (AFL) undergoing successful cavotricuspid isthmus ablation remain at risk for future development of new-onset atrial fibrillation (AF). Conventional monitoring (CM) techniques have shown AF incidence rates of 18%-50% in these patients. OBJECTIVES: To evaluate whether continuous monitoring using implantable loop recorders (ILRs) would enhance AF detection in this patient population. METHODS: Veteran patients undergoing AFL ablation between 2002 and 2019 who completed at least 6 months of follow-up after the ablation procedure were included. We compared new-onset AF detection between those who underwent CM and those who received ILRs immediately following AFL ablation. RESULTS: A total of 217 patients (age: 66 ± 9 years; all male) participated. CM was used in 172 (79%) and ILR in 45 (21%) patients. Median follow-up duration after ablation was 4.1 years. Seventy-nine patients (36%) developed new-onset AF, which was detected by CM in 51 and ILR in 28 (30% vs 62%, respectively, P < .001). AF detection occurred at 7.7 months (IQR: 4.7-17.5) after AFL ablation in the ILR group vs 41 months (IQR: 23-72) in the CM group (P < .001). Eleven patients (5%) experienced cerebrovascular events (all in the CM group) and only 4 of these patients (36%) were on long-term anticoagulation. CONCLUSION: Patients undergoing AFL ablation remain at an increased risk of developing new-onset AF, which is detected sooner and more frequently by ILR than by CM. Improving AF detection may allow optimization of rhythm management strategies and anticoagulation in this patient population.

5.
JACC Clin Electrophysiol ; 6(11): 1381-1392, 2020 10 26.
Article En | MEDLINE | ID: mdl-33121667

OBJECTIVES: This study sought to address whether technological innovations such as contact force sensing (CFS) can improve acute and long-term ablation outcomes of left ventricular papillary muscle (LV PAP) ventricular arrhythmias (VAs). BACKGROUND: Catheter ablation of LV PAP VAs has been less efficacious than another focal VAs. It remains unclear whether technological innovations such as CFS can improve acute and long-term ablation outcomes of LV PAP VA. METHODS: From January 2015 to December 2019, a total of 137 patients underwent LV PAP VA ablation. VA site of origin (SOO) was identified using activation and pace-mapping guided by intracardiac echocardiography. Radiofrequency energy (20 to 50 W for 60 to 90 s) was delivered by irrigated catheter with or without CFS. We defined acute success as complete suppression of targeted VA ≥30 min post ablation and clinical success as ≥80% VA burden reduction at outpatient follow-up. RESULTS: VA manifested as premature ventricular complexes in 98 (71%), nonsustained ventricular tachycardia in 18 (13%), sustained ventricular tachycardia in 12 (9%) and premature ventricular complexes induced ventricular fibrillation in 9 (7%). VA SOO was anterolateral PAP in 51 (37%), posteromedial PAP in 73 (53%), and both PAPs in 13 (10%). VAs were targeted using CFS in 97 (71%) and non-CFS in 40 (29%). After a single procedure, acute success was achieved in 130 (95%) and clinical success was achieved in 112 (82%); neither was impacted by VA SOO and/or CFS. Complications occurred in 5 patients (3.6%). CONCLUSION: Independent of CFS technology, intracardiac echocardiography-guided catheter ablation is highly efficacious and may be considered as first-line therapy in the management of LV PAP VA.


Catheter Ablation , Tachycardia, Ventricular , Ventricular Premature Complexes , Heart Ventricles/diagnostic imaging , Heart Ventricles/surgery , Humans , Papillary Muscles/diagnostic imaging , Papillary Muscles/surgery , Tachycardia, Ventricular/surgery , Ventricular Premature Complexes/surgery
6.
Heart Rhythm ; 17(7): 1132-1138, 2020 07.
Article En | MEDLINE | ID: mdl-32112873

BACKGROUND: Postoperative bradycardia can complicate orthotopic heart transplantation (OHT). Previous studies suggested donor age and surgical technique as possible risk factors. However, risk factors in the era of bicaval anastomosis have not been elucidated. OBJECTIVE: We sought to examine the association between donor/recipient characteristics with need for chronotropic support and permanent pacemaker (PPM) implantation in patients with OHT. METHODS: All patients treated with OHT between January 2003 and January 2018 at the Hospital of the University of Pennsylvania were retrospectively evaluated until June 2018. Chronotropic support was given upon postoperative inability to increase the heart rate to patient's demands and included disproportionate bradycardia and junctional rhythm. RESULTS: A total of 820 patients (mean age 51.3 ± 12.6 years; 607, 74% men) underwent 826 OHT procedures (787 patients, 95.3% bicaval anastomosis). Patients who were exposed to amiodarone (odds ratio [OR] 2.30; 95% confidence interval [CI] 1.58-3.34; P < .001) and have older donor (OR 1.02; 95% CI 1.01-1.04; P = .001) were more likely to develop need for chronotropic support. In multivariable analysis, recipient age (OR 1.03; 95% CI 1.00-1.06; P = .04) and biatrial anastomosis (OR 6.12; 95% CI 2.48-15.09) were significantly associated with PPM implantation within 6 months of OHT. No association was found between pre-OHT amiodarone use and PPM implantation. No risk factors assessed were associated with PPM implantation 6 months post-OHT. CONCLUSION: Surgical technique and donor age were the main risk factors for the need for chronotropic support post-OHT, whereas surgical technique and recipient age were risk factors for early PPM implantation.


Bradycardia/therapy , Heart Transplantation/adverse effects , Pacemaker, Artificial , Tissue Donors , Bradycardia/etiology , Female , Follow-Up Studies , Humans , Male , Middle Aged , Retrospective Studies , Risk Factors , Treatment Outcome
...