Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Microsyst Nanoeng ; 10: 102, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39045232

RESUMEN

With the rapid development of various fields, including aerospace, industrial measurement and control, and medical monitoring, the need to quantify flow velocity measurements is increasing. It is difficult for traditional flow velocity sensors to fulfill accuracy requirements for velocity measurements due to their small ranges, susceptibility to environmental impacts, and instability. Herein, to optimize sensor performance, a flexible microelectromechanical system (MEMS) thermal flow sensor is proposed that combines the working principles of thermal loss and thermal temperature difference and utilizes a flexible cavity substrate made of a low-thermal-conductivity polyimide/SiO2 (PI/SiO2) composite porous film to broaden the measurement range and improve the sensitivity. The measurement results show that the maximum measurable flow velocity can reach 30 m/s with a resolution of 5.4 mm/s. The average sensitivities of the sensor are 59.49 mV/(m s-1) in the medium-to-low wind velocity range of 0-2 m/s and 467.31 mV/(m s-1) in the wind velocity range of 2-30 m/s. The sensor proposed in this work can enable new applications of flexible flow sensors and wearable devices.

2.
Nanoscale ; 16(29): 13945-13952, 2024 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-38980062

RESUMEN

Hollow core fibers, supporting waveguiding in a void, open a room of opportunities for numerous applications owing to an extended light-matter interaction distance and relatively high optical confinement. Decorating an inner capillary with functional materials allows tailoring the fiber's optical properties further and turns the structure into a functional device. Here, we functionalize an anti-resonant hollow-core fiber with 18 nm-size gold nanoparticles, approaching a uniform 45% surface coverage along 10 s of centimeters along its inner capillary. Owing to a moderately low overlap between the fundamental mode and the gold layer, the fiber maintains its high transmission properties; nevertheless, the entire structure experiences considerable heating, which is observed and quantified with the aid of a thermal camera. The hollow core and the surrounding capillary are subsequently filled with ethanol and thermo-optical heating is demonstrated. We also show that at moderate laser intensities, the liquid inside the fiber begins to boil and, as a result, the optical guiding is destroyed. The gilded hollow core fiber and its high thermal-optical responsivity suggest considering the structure as an efficient optically driven catalytic reactor in applications where either small reaction volumes or remote control over a process are demanded.

3.
Biosens Bioelectron ; 258: 116291, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38735080

RESUMEN

Depression is one of the most common mental disorders and is mainly characterized by low mood or lack of interest and pleasure. It can be accompanied by varying degrees of cognitive and behavioral changes and may lead to suicide risk in severe cases. Due to the subjectivity of diagnostic methods and the complexity of patients' conditions, the diagnosis of major depressive disorder (MDD) has always been a difficult problem in psychiatry. With the discovery of more diagnostic biomarkers associated with MDD in recent years, especially emerging non-coding RNAs (ncRNAs), it is possible to quantify the condition of patients with mental illness based on biomarker levels. Point-of-care biosensors have emerged due to their advantages of convenient sampling, rapid detection, miniaturization, and portability. After summarizing the pathogenesis of MDD, representative biomarkers, including proteins, hormones, and RNAs, are discussed. Furthermore, we analyzed recent advances in biosensors for detecting various types of biomarkers of MDD, highlighting representative electrochemical sensors. Future trends in terms of new biomarkers, new sample processing methods, and new detection modalities are expected to provide a complete reference for psychiatrists and biomedical engineers.


Asunto(s)
Biomarcadores , Técnicas Biosensibles , Trastorno Depresivo Mayor , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , Humanos , Biomarcadores/análisis , Trastorno Depresivo Mayor/diagnóstico , Trastorno Depresivo Mayor/genética , Sistemas de Atención de Punto , Técnicas Electroquímicas/métodos
4.
Biosens Bioelectron ; 255: 116090, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38569250

RESUMEN

Cardiovascular diseases (CVDs), especially chronic heart failure, threaten many patients' lives worldwide. Because of its slow course and complex causes, its clinical screening, diagnosis, and prognosis are essential challenges. Clinical biomarkers and biosensor technologies can rapidly screen and diagnose. Multiple types of biomarkers are employed for screening purposes, precise diagnosis, and treatment follow-up. This article provides an up-to-date overview of the biomarkers associated with the six main heart failure etiology pathways. Plasma natriuretic peptides (BNP and NT-proBNP) and cardiac troponins (cTnT, cTnl) are still analyzed as gold-standard markers for heart failure. Other complementary biomarkers include growth differentiation factor 15 (GDF-15), circulating Galactose Lectin 3 (Gal-3), soluble interleukin (sST2), C-reactive protein (CRP), and tumor necrosis factor-alpha (TNF-α). For these biomarkers, the electrochemical biosensors have exhibited sufficient sensitivity, detection limit, and specificity. This review systematically summarizes the latest molecular biomarkers and sensors for heart failure, which will provide comprehensive and cutting-edge authoritative scientific information for biomedical and electronic-sensing researchers in the field of heart failure, as well as patients. In addition, our proposed future outlook may provide new research ideas for researchers.


Asunto(s)
Técnicas Biosensibles , Insuficiencia Cardíaca , Humanos , Biomarcadores , Pronóstico , Péptido Natriurético Encefálico , Insuficiencia Cardíaca/diagnóstico , Proteína C-Reactiva/metabolismo , Fragmentos de Péptidos
5.
Nanomaterials (Basel) ; 14(6)2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38535686

RESUMEN

Considering the magnetic shielding requirements of both geomagnetic field and 50 Hz power-line frequency in the complex working conditions of the power grid, an electromagnetic shielding system combining active and passive modes is proposed in this article. A three-dimensional Helmholtz coil with a magnetic shielding barrel nested inside is established by the COMSOL simulation tool, and the magnetic shielding efficiency of the system is analyzed. Comparing different materials, the simulation results indicate that permalloy alloy exhibits better shielding performance than pure iron and nickel materials. Additionally, the overall shielding efficiency of the shielding barrel increases linearly with the number of multiple layers. Under the combined active and passive electromagnetic shielding conditions, the system achieves a shielding efficiency of SE = 113.98 dB, demonstrating excellent performance in shielding both AC and DC interference magnetic fields. This study provides theoretical guidance for the construction of magnetic shielding systems in electromagnetic interference environment.

6.
Microsyst Nanoeng ; 10: 24, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38344149

RESUMEN

Stress tolerance plays a vital role in ensuring the effectiveness of piezoresistive sensing films used in flexible pressure sensors. However, existing methods for enhancing stress tolerance employ dome-shaped, wrinkle-shaped, and pyramidal-shaped microstructures in intricate molding and demolding processes, which introduce significant fabrication challenges and limit the sensing performance. To address these shortcomings, this paper presents periodic microslits in a sensing film made of multiwalled carbon nanotubes and polydimethylsiloxane to realize ultrahigh stress tolerance with a theoretical maximum of 2.477 MPa and a sensitivity of 18.092 kPa-1. The periodic microslits permit extensive deformation under high pressure (e.g., 400 kPa) to widen the detection range. Moreover, the periodic microslits also enhance the sensitivity based on simultaneously exhibiting multiple synapses within the sensing interface and between the periodic sensing cells. The proposed solution is verified by experiments using sensors based on the microslit strategy for wind direction detection, robot movement sensing, and human health monitoring. In these experiments, vehicle load detection is achieved for ultrahigh pressure sensing under an ultrahigh pressure of over 400 kPa and a ratio of the contact area to the total area of 32.74%. The results indicate that the proposed microslit strategy can achieve ultrahigh stress tolerance while simplifying the fabrication complexity of preparing microstructure sensing films.

7.
Colloids Surf B Biointerfaces ; 234: 113742, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38271855

RESUMEN

Because of the excellent performance in photochemistry, WO3 is increasingly applied in the field of biology and medicine. However, little is known about the mechanism of WO3 cytotoxicity. In this work, WO3 nanosheets with oxygen vacancy are synthesized by solvothermal method, then characterized and added to culture medium of human umbilical vein endothelial cells (HUVECs) with different concentrations. We characterized and analyzed the morphology of nano-WO3 by transmission electron microscopy and calculated the specific data of oxygen vacancy by XPS. It is the first time the effect of WO3-x on cells that WO3-x can cause oxidative stress in HUVEC cells, resulting in DNA damage and thus promoting apoptosis. Transcriptome sequencing is performed on cells treated with low and high concentrations of WO3-x, and a series of key signals affecting cell proliferation and apoptosis are detected in differentially expressed genes, which indicates the research direction of nanotoxicity. The expression levels of key genes are also verified by quantitative PCR after cell treatment with different concentrations of WO3-x. This work fills the gap between the biocompatibility of nano WO3-x materials and molecular cytology and paves the way for investigating the mechanism and risks of oxygen vacancy in cancer therapy.


Asunto(s)
Óxidos , Oxígeno , Humanos , Células Endoteliales de la Vena Umbilical Humana , Óxidos/química , Tungsteno/toxicidad , Tungsteno/química
8.
Nanomaterials (Basel) ; 14(2)2024 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-38276739

RESUMEN

An intensity-demodulated fiber-optic magnetometer is proposed and experimentally investigated, which is fabricated via fusion splicing a segment of photonic crystal fiber (PCF) between single-mode fibers (SMFs), with the cladding air holes of PCF filled with magnetic fluid. Using the magneto-optical properties of the magnetic fluid, the transmission spectrum is changed with an external magnetic field. Based on the intensity variations in the transmission spectrum, the magnetic field is detected, and a sensitivity of 0.238 dB/mT is obtained at 1550.03 nm with the length of PCF 5.5 cm. By converting light signals into electrical signals, a sensitivity of 0.003 V/mT is achieved. The fiber-optic magnetometer possesses the advantages of simple fabrication, compact/robust structure, and low cost.

9.
Micromachines (Basel) ; 14(12)2023 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-38138309

RESUMEN

In this work, a novel fiber-optic sensor for 2D magnetic sensing is explored based on nanostructured magnetic fluid. The fiber-optic sensor comprises a ring-shaped fiber structure that is coated with magnetic fluid. The unique magneto-optical characteristic of the nanostructured magnetic fluid enables the fiber-optic structure to detect magnetic fields. By utilizing the 3D Monte Carlo method, the magneto-optical characteristic induced by the nanostructure changes in the magnetic fluid was analyzed. The sensor can realize 2D vector magnetic sensing by intensity demodulation and achieves a sensitivity of 2.402 dB/mT. The proposed fiber optic sensor helps in developing a high-sensitivity 2D vector magnetic field sensor, which has potential applications in the fields of navigation, electrical power systems, and biological detection.

10.
Micromachines (Basel) ; 14(12)2023 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-38138304

RESUMEN

This study discussed the application of optical fibers in addressing the problem of insufficient light harvesting and sensing health monitoring in ancient buildings. Based on three-dimensional (3D) printing technology to fix the light-harvesting lens and conducting optical fiber, develop the replacement parts that can be buried into the optical fiber of ancient buildings. By introducing the experimental application to improve the experimental quality of research and teaching. Firstly, it highlights the advantage that the optical fiber plus lens structure design can make the natural light introduced for a long time; secondly, it points out that the buried optical fiber structure design does not affect the warmth and sound insulation of the building; finally, the health monitoring of the building is realized through the proposed method of buried optical fiber sensing. The design scheme adopts a fiber optic light transmission and sensing system, which can realize the whole system's corrosion resistance, after laying buried and low-cost operation.

11.
Nanomaterials (Basel) ; 13(22)2023 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-37999302

RESUMEN

A co-sputtering process for the deposition of Fe0.8Ga0.2B alloy magnetostrictive thin films is studied in this paper. The soft magnetic performance of Fe0.8Ga0.2B thin films is modulated by the direct-current (DC) sputtering power of an FeGa target and the radio-frequency (RF) sputtering power of a B target. Characterization results show that the prepared Fe0.8Ga0.2B films are amorphous with uniform thickness and low coercivity. With increasing FeGa DC sputtering power, coercivity raises, resulting from the enhancement of magnetism and grain growth. On the other hand, when the RF sputtering power of the B target increases, the coercivity decreases first and then increases because of the conversion of the films from a crystalline to an amorphous state. The lowest coercivity of 7.51 Oe is finally obtained with the sputtering power of 20 W for the FeGa target and 60 W for the B target. Potentially, this optimization provides a simple way for improving the magnetoelectric coefficient of magnetoelectric composite materials and the sensitivity of magnetoelectric sensors.

12.
Microsyst Nanoeng ; 9: 133, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37886351

RESUMEN

With the growing demand for thermal management of electronic devices, cooling of high-precision instruments, and biological cryopreservation, heat flux measurement of complex surfaces and at ultralow temperatures has become highly imperative. However, current heat flux sensors (HFSs) are commonly used in high-temperature scenarios and have problems when applied in low-temperature conditions, such as low sensitivity and embrittlement. In this study, we developed a flexible and highly sensitive HFS that can operate at ultralow to high temperatures, ranging from -196 °C to 273 °C. The sensitivities of HFSs with thicknesses of 0.2 mm and 0.3 mm, which are efficiently manufactured by the screen-printing method, reach 11.21 µV/(W/m2) and 13.43 µV/(W/m2), respectively. The experimental results show that there is a less than 3% resistance change from bending to stretching. Additionally, the HFS can measure heat flux in both exothermic and absorptive cases and can measure heat flux up to 25 kW/m2. Additionally, we demonstrate the application of the HFS to the measurement of minuscule heat flux, such as heat dissipation of human skin and cold water. This technology is expected to be used in heat flux measurements at ultralow temperatures or on complex surfaces, which has great importance in the superconductor and cryobiology field.

13.
Nanomaterials (Basel) ; 13(19)2023 Sep 24.
Artículo en Inglés | MEDLINE | ID: mdl-37836271

RESUMEN

At present, flexible pressure-sensitive materials generally have problems with weak adhesion and poor wear resistance, which easily result in friction failure when used for plantar pressure detection. In this study, a flexible pressure sensor with the advantages of a wide detection range, fast recovery, and good abrasive resistance was designed and prepared based on the screen printing process. The pressure-sensitive unit with a structural size of 5 mm× 8 mm was a functional material system due to the use of graphene and epoxy resin. The influence of the different mass ratios of the graphene and epoxy resin on the sensing properties was also studied. The test results showed that when the mass ratio of graphene to epoxy resin was 1:4, the response time and recovery time of the sensing unit were 40.8 ms and 3.7 ms, respectively, and the pressure detection range was 2.5-500 kPa. The sensor can detect dynamic pressure at 0.5 Hz, 1 Hz, 2 Hz, 10 Hz, and 20 Hz and can withstand 11,000 cycles of bending. In addition, adhesion tests showed that the high viscosity of the epoxy helped to improve the interlayer bond between the pressure-sensitive materials and the flexible substrate, which makes it more suitable for plantar pressure detection environments, where friction is common.

14.
Micromachines (Basel) ; 14(9)2023 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-37763825

RESUMEN

Here, we present a high-precision demodulation method that supports the arrayed waveguide grating (AWG) system, which includes a 1 × 8 AWG as the primary filter with a 0.5 nm channel spacing and a 1 × 4 AWG as the auxiliary filter with a 1 nm channel spacing. The high precision is achieved through an innovative method of decoupling three channels, involving two adjacent channels of the primary filter and one channel of the secondary auxiliary filter. Simulation results show that the AWGs have a good transmission spectrum with crosstalk below -24.8 dB, non-uniformities below 0.8 dB, insertion loss below -3.7 dB, 3 dB bandwidth of 0.25 nm, and 10 dB bandwidth of 0.43 nm. The interrogation precision can reach 8 pm, with a dynamic range of 0.4 nm, corresponding to a single FBG.

15.
Opt Lett ; 48(15): 4045-4048, 2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-37527114

RESUMEN

The nitrogen vacancy (NV) centers in diamonds have gathered increasing interest as an emerging quantum sensing platform with high sensitivity and spatial resolution. Integration of micro-sized diamond and fiber is an essential method to build an NV center endoscope probe and enable NV center sensors for practical application. However, the low fluorescence collection efficiency of fibers due to their small numerical aperture (NA) has limited the sensitivity of the sensors. In this paper, a cone-shape microlens was fabricated using the photopolymerization process at the end of a multimode fiber to boost the laser excitation and fluorescence collection efficiency of NV centers. Experiments demonstrated that over 21 times fluorescence intensity enhancement and 12 times sensitivity improvement were achieved. This fiber-microlens magnetometer probe exhibited a 2.1-nT/Hz1/2 sensitivity over a bandwidth of 100 Hz with ∼80-µm diameter diamond. This research presented a robust and large NA diamond integrated fiber-microlens magnetometer probe, which can also be expanded to magnetic field scan and real-time monitoring.

16.
Small ; 19(48): e2304599, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37544920

RESUMEN

Considerable thermal energy is emitted into the environment from human activities and equipment operation in the course of daily production. Accordingly, the use of thermoelectric generators (TEGs) can attract wide interest, and it shows high potential in reducing energy waste and increasing energy recovery rates. Notably, TEGs have aroused rising attention and been significantly boosted over the past few years, as the energy crisis has worsened. The reason for their progress is that thermoelectric generators can be easily attached to the surface of a heat source, converting heat energy directly into electricity in a stable and continuous manner. In this review, applications in wearable devices, and everyday life are reviewed according to the type of structure of TEGs. Meanwhile, the latest progress of TEGs' hybridization with triboelectric nanogenerator (TENG), piezoelectric nanogenerator (PENG), and photovoltaic effect is introduced. Moreover, prospects and suggestions for subsequent research work are proposed. This review suggests that hybridization of energy harvesting, and flexible high-temperature thermoelectric generators are the future trends.

17.
Nanomaterials (Basel) ; 13(5)2023 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-36903827

RESUMEN

Magnetometers based on nitrogen-vacancy (NV) centers in diamonds have promising applications in fields of living systems biology, condensed matter physics, and industry. This paper proposes a portable and flexible all-fiber NV center vector magnetometer by using fibers to substitute all conventional spatial optical elements, realizing laser excitation and fluorescence collection of micro-diamond with multi-mode fibers simultaneously and efficiently. An optical model is established to investigate multi-mode fiber interrogation of micro-diamond to estimate the optical performance of NV center system. A new analysis method is proposed to extract the magnitude and direction of the magnetic field, combining the morphology of the micro-diamond, thus realizing µm-scale vector magnetic field detection at the tip of the fiber probe. Experimental testing shows our fabricated magnetometer has a sensitivity of 0.73 nT/Hz1/2, demonstrating its feasibility and performance in comparison with conventional confocal NV center magnetometers. This research presents a robust and compact magnetic endoscopy and remote-magnetic measurement approach, which will substantially promote the practical application of magnetometers based on NV centers.

18.
Nanomaterials (Basel) ; 13(4)2023 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-36838999

RESUMEN

GaN high-electron-mobility transistor (HEMT) terahertz (THz) detectors have been widely studied and applied in the past few decades. However, there are few reports about the influence of GaN/AlGaN heterostructure material properties on the detection model at present. In this paper, a response voltage model for a GaN HEMT THz detector that considers the carrier scattering in a GaN/AlGaN heterostructure is proposed. The phonon scattering, dislocation scattering, and interface roughness scattering mechanisms are taken into account in the classic THz response voltage model; furthermore, the influence of various material parameters on the response voltage is studied. In a low-temperature region, acoustic scattering plays an important role, and the response voltage drops with an increase in temperature. In a high temperature range, optical phonon scattering is the main scattering mechanism, and the detector operates in a non-resonant detection mode. With an increase in carrier surface density, the response voltage decreases and then increases due to piezoelectric scattering and optical phonon scattering. For dislocation and interface roughness scattering, the response voltage is inversely proportional to the dislocation density and root mean square roughness (RMS) but is positively related to lateral correlation length. Finally, a comparison between our model and the reported models shows that our proposed model is more accurate.

19.
Opt Express ; 31(3): 3743-3754, 2023 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-36785360

RESUMEN

The electronic spin polarization of alkali-metal-vapor atoms is a pivotal parameter for atomic magnetometers. Herein, a novel method is presented for determining the spin polarization with a miniaturized single-beam spin-exchange-relaxation-free (SERF) magnetometer on the basis of zero-field cross-over resonance. Two separate laser beams are utilized to heat the cell and interrogate the vapor atoms, respectively. Spin polarization can be extracted by measuring the resonance response signal of the magnetometer to the transverse magnetic field under different irradiances. Results of these experiments are consistent well with the theoretical predictions with the maximum deviation less than 4%. The proposed method has the integrated advantages of possessing a simple configuration and in-situ measurement. Furthermore, combined with a homemade optical differential detection system with a factor of approximately three of the power noise suppression, the developed single-beam SERF atomic magnetometer with a measuring sensitivity of 32 fT/Hz1/2 has been achieved. This demonstrated approach can help guide the development of chip-scale atomic magnetometers for bio-magnetic field imaging applications.

20.
Opt Express ; 30(10): 16541-16552, 2022 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-36221495

RESUMEN

We describe a single beam compact spin exchange relaxation free (SERF) magnetometer whose configuration is simple and compatible with the silicon-glass bonding micro-machining method. Due to the small size of the vapor cell utilized in a miniature atomic magnetometer, the wall relaxation could not be neglected. In this study we show that Ne buffer gas is more efficient than that of the other typically utilized gas species such as nitrogen and helium for wall relaxation reduction theoretically and experimentally. 3 Amagats (1 Amagat=2.69×1019/cm3) Ne gas is filled in the vapor cell and this is the first demonstration of a Cs-Ne SERF magnetometer. In order to reduce the laser amplitude noise and the large background detection offset, which is reported to be the main noise source of a single beam absorption SERF magnetometer, we developed a laser power differential method and a factor of approximately two improvement of the power noise suppression has been demonstrated. In order to reduce the power consumption of the magnetometer, the Cs based atomic magnetometer is studied. We did an optimization of the magnetometer and a sensitivity of 23fT/Hz1/2@100Hz has been achieved. This is the first demonstration of a single beam Cs based SERF magnetometer.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA