Antimicrobial susceptibility testing (AST) is a key measure in clinical microbiology laboratories to enable appropriate antimicrobial administration. During an AST, the determination of the minimum inhibitory concentration (MIC) is an important step in which the bacterial responses to an antibiotic at a series of concentrations obtained in separate bacterial growth chambers or sites are compared. However, the preparation of different antibiotic concentrations is time-consuming and labor-intensive. In this paper, we present a microfluidic device that generates a concentration gradient for antibiotics that is produced by diffusion in the laminar flow regime along a series of lateral microwells to encapsulate bacteria for antibiotic treatment. All the AST preparation steps (including bacterium loading, antibiotic concentration generation, buffer washing, and isolated bacterial growth with an antibiotic) can be performed in a single chip. The viable bacterial cells in each microwell after the antibiotic treatment are then quantified by their surface-enhanced Raman scattering (SERS) signals that are acquired after placing a uniform SERS-active substrate in contact with all the microwells. For proof-of-concept, we demonstrated the AST performance of this system on ampicillin (AMP)-susceptible and -resistant E. coli strains. Compared with the parameters for conventional AST methods, the AST procedure based on this chip requires only 20 µL of bacteria solution and 5 h of operation time. This result indicates that this integrated system can greatly shorten and simplify the tedious and labor-intensive procedures required for current standard AST methods.


Anti-Bacterial Agents , Anti-Infective Agents , Anti-Bacterial Agents/pharmacology , Bacteria , Escherichia coli , Lab-On-A-Chip Devices , Microbial Sensitivity Tests , Microfluidics/methods , Spectrum Analysis, Raman
2.
Sci Rep ; 11(1): 23475, 2021 12 06.
Article En | MEDLINE | ID: mdl-34873208

Fluorescence lifetime imaging microscopy of a fluorescence probe, 3,6-bis(1-methyl-2-vinylpyridinium) carbazole diiodide (o-BMVC), provides an objective method for preoperative diagnosis of fine-needle aspiration (FNA) of thyroid nodules. The key of this o-BMVC test of FNA smears is the measurement of the digital number of o-BMVC foci in the nucleus. Thus, there are three categories classified in the o-BMVC test, which are nondiagnostic for unsatisfactory samples, benign for less numbers of o-BMVC foci, and malignant for more numbers of o-BMVC foci. The discrimination of indeterminate (including atypia, follicular neoplasm, suspicious) cytology into benign or malignant cases can reduce diagnostic uncertainty and benefit clinical decision making. This pilot study strongly suggests that the o-BMVC test is an invaluable method for diagnosing FNA samples. Particularly, the combination of FNA cytology and the o-BMVC test holds great promise to improve the efficacy of diagnosis and reduce the healthcare costs.


Thyroid Nodule/pathology , Adolescent , Adult , Aged , Aged, 80 and over , Biopsy, Fine-Needle/methods , Carbazoles/administration & dosage , Cytodiagnosis/methods , Female , Fluorescent Dyes/administration & dosage , Humans , Male , Microscopy, Fluorescence/methods , Middle Aged , Pilot Projects , Pyridinium Compounds/administration & dosage , Thyroid Gland/pathology , Thyroid Neoplasms/diagnosis , Thyroid Neoplasms/pathology , Young Adult
3.
Biosens Bioelectron ; 191: 113483, 2021 Nov 01.
Article En | MEDLINE | ID: mdl-34246896

Bloodstream infection (BSI) is a serious public health issue worldwide. Timely and effective antibiotics for controlling infection are crucial towards patient outcomes. However, the current culture-based methods of identifying bacteria and antimicrobial susceptibility testing (AST) remain labor-intensive and time-consuming, and are unable to provide early support to physicians in critical hours. To improve the effectiveness of early antibiotic therapy, Surface-enhanced Raman scattering (SERS) technology, has been used in bacterial detection and AST based on its high specificity and label-free features. To simplify sample preparation steps in SERS-AST, we proposed an automated microfluidic control system to integrate all required procedures into a single device. Our preliminary results demonstrated the system can achieve on-chip reagent replacement, bacteria trapping, and buffer exchange. Finally, in-situ SERS-AST was performed within 3.5 h by loading isolates of ampicilin susceptible and resistant E. coli and clear discrimination of two strains under antibiotic treatment was demonstrated. Overall, our system can standardize and simplify the SERS-AST protocol and implicate parallel bacterial detection. This prototypical integration demonstrates timely microbiological support to optimize early antibiotic therapy for fighting bacteremia.


Biosensing Techniques , Microfluidics , Anti-Bacterial Agents/pharmacology , Escherichia coli , Humans , Microbial Sensitivity Tests , Spectrum Analysis, Raman
4.
Lab Chip ; 20(14): 2520-2528, 2020 07 14.
Article En | MEDLINE | ID: mdl-32542276

The antibiotic susceptibility test (AST) is a general laboratory procedure for bacterial identification and characterization and can be utilized to determine effective antimicrobials for individual patients. Due to the low bacterial concentration, conventional AST usually requires a prolonged bacterial culture time and a labor-intensive sample pretreatment process. Therefore, it cannot perform timely diagnosis or treatment, which results in a high mortality rate for seriously infected patients. To address this problem, we developed a microfluidic microwell device integrating surface-enhanced Raman scattering (SERS) technology, or the so called the Microwell-SERS system, to enable a rapid and high-throughput AST. Our results show that the Microwell-SERS system can successfully encapsulate bacteria in a miniaturized microwell with a greatly increased effective bacteria concentration, resulting in a shorter bacterial culture time. By attaching a microchannel onto the microwell, a smooth liquid and air exchange can purify the surrounding buffer and isolate bacteria in an individual microwell for independent SERS measurement. For proof-of-concept, we demonstrated a 2 h AST on susceptible and resistant E. coli and S. aureus with a concentration of 103 CFU mL-1 in the Microwell-SERS system, whereas the previous SERS-AST method required 108 CFU mL-1 bacterial suspension droplets dispensing on a SERS substrate. Based on the above features, we envision that the Microwell-SERS system could achieve highly sensitive, label-free, bacteria detection and rapid AST to enable timely and accurate bacterial infection disease diagnosis.


Spectrum Analysis, Raman , Staphylococcus aureus , Anti-Bacterial Agents/pharmacology , Bacteria , Escherichia coli , Humans , Microfluidics
5.
Molecules ; 24(1)2018 Dec 21.
Article En | MEDLINE | ID: mdl-30583464

G-quadruplex (G4) structures have recently received increasing attention as a potential target for cancer research. We used time-gated fluorescence lifetime imaging microscopy (FLIM) with a G4 fluorescent probe, 3,6-bis(1-methyl-2-vinylpyridinium) carbazole diiodide (o-BMVC), to measure the number of o-BMVC foci, which may represent G4 foci, in cells as a common signature to distinguish cancer cells from normal cells. Here, the decrease in the number of o-BMVC foci in the pretreatment of cancer cells with TMPyP4, BRACO-19 and BMVC4 suggested that they directly bind to G4s in cells. In contrast, the increase in the number of o-BMVC foci in the pretreatment of cells with PDS and Hoechst 33258 (H33258) suggested that they do not inhabit the binding site of o-BMVC to G4s in cells. After the H33258 was removed, the gradual decrease of H33258-induced G4 foci may be due to DNA repair. The purpose of this work is to introduce o-BMVC foci as an indicator not only to verify the direct binding of potential G4 ligands to G4 structures but also to examine the possible effect of some DNA binding ligands on DNA integrity by monitoring the number of G4 foci in cells.


Carbazoles/chemistry , DNA/chemistry , Fluorescent Dyes/chemistry , G-Quadruplexes , Microscopy, Fluorescence , Pyridinium Compounds/chemistry , Circular Dichroism , DNA/metabolism , Fluorescent Dyes/metabolism , Humans , Ligands
...