1.
Heliyon ; 10(4): e26001, 2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38404873

RESUMEN

Mass reduction of mechanical systems is a recurrent objective in engineering, which is often reached by removing material from its mechanical parts. However, this material removal leads to a decrease of mechanical performances for the parts, which must be minimized and controlled to avoid a potential system failure. To find a middle-ground between material removing and mechanical performances), material must be kept only in areas where it is necessary, for example using stress-driven material removal methods. These methods use the stress field to define the local material removal based on two local parameters: the local volume fraction vf and the structural anisotropy orientation ß. These methods may be based on different types of cellular structure patterns: lattice-based or bio-inspired. The long-term objective of this study is to improve the performance of stress-driven methods by using the most efficient pattern. For this purpose, this study investigates the influence of vf and ß on the mechanical stiffness of three planar cellular structures called Periodic Stress-Driven Material Removal (PSDMR) structures. The first, taken from the literature, is bio-inspired from bone and based on a square pattern. The second, developed in this study, is also bio-inspired from bone but based on a rectangular pattern. The third is a strut-based lattice pattern well documented in the literature for its isotropic behavior. These three patterns are compared in this study in terms of relative longitudinal stiffness, obtained through linear elastic compressive tests by finite element analysis. It is highlighted that each PSDMR pattern has a specific domain in which it performs better than the two others. In future works, these domains could be used in stress-driven material removal methods to select the most adequate pattern or a mix of them to improve the performances of parts.

2.
Sci Rep ; 14(1): 2177, 2024 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-38272957

RESUMEN

Synovial joints, such as the elbow, experience different lubrication regimes, ranging from fluid film to boundary lubrication, depending on locomotion conditions. We explore the relationship between the elbow lubrication regime and the size of quadrupedal mammals. We use allometry to analyze the dimensions, contact stress, and sliding speed of the elbow in 110 quadrupedal mammals. Our results reveal that the average diameter and width of the distal humerus are scaled [Formula: see text], which allowed us to estimate a consistent contact pressure and sliding speed across mammals. This consistency likely promotes fluid film lubrication regardless of body mass. Further, the ratio between the diameter and width is about 0.5 for all analyzed taxa, which is a good compromise between loading capacity and size. Our study deepens our understanding of synovial joints and their adaptations, with implications for the development of treatments, prostheses, and bioinspired joint designs.


Asunto(s)
Codo , Líquido Sinovial , Animales , Lubrificación , Articulaciones , Mamíferos , Fricción
3.
Bioinspir Biomim ; 18(1)2022 11 21.
Artículo en Inglés | MEDLINE | ID: mdl-36322997

RESUMEN

Designing resilient actuators is a challenge for industry, in part because an index for resilience has yet to be established. In this work, several definitions of resilience are analysed and, on the basis of this, an index quantifying resilience for actuators is proposed. This index does indeed allow for the resilience computation of a wide range of manufactured and biological actuators to be compared. The two manufactured actuators chosen as iconic models are a hydraulic cylinder and a bio-inspired McKibben muscle, and these are shown not to be resilient by design. In addition, two biological actuators likely to be resilient were also analysed. The pulvinus resilience index shows that it is partly resilient depending on damage location. But the most promising is the skeletal muscle, which has been shown to be highly resilient. Finally, the bio-inspired roots of resilience are discussed: resilience may originate from multi-scale structural design.


Asunto(s)
Músculo Esquelético , Raíces de Plantas
4.
Bioinspir Biomim ; 17(6)2022 09 06.
Artículo en Inglés | MEDLINE | ID: mdl-35944519

RESUMEN

Mimosa pudicarapidly folds leaves when touched. Motion is created by pulvini, 'the plant muscles' that allow plants to produce various complex motions. Plants rely on local control of the turgor pressure to create on-demand motion. In this paper, the mechanics of a cellular material inspired from pulvinus ofM. pudicais studied. First, the manufacturing process of a cell-controllable material is described. Its deformation behaviour when pressured is tested, focusing on three pressure patterns of reference. The deformations are modelled based on the minimisation of elastic energy framework. Depending on pressurisation pattern and magnitude, reversible buckling-induced motion may occur.


Asunto(s)
Pulvino , Hojas de la Planta
5.
Front Bioeng Biotechnol ; 10: 767914, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35299633

RESUMEN

Quadrupeds and hexapods are known by their ability to adapt their locomotive patterns to their functions in the environment. Computational modeling of animal movement can help to better understand the emergence of locomotive patterns and their body dynamics. Although considerable progress has been made in this subject in recent years, the strengths and limitations of kinematic simulations at the scale of small moving animals are not well understood. In response to this, this work evaluated the effects of modeling uncertainties on kinematic simulations at small scale. In order to do so, a multibody model of a Messor barbarus ant was developed. The model was built from 3D scans coming from X-ray micro-computed tomography. Joint geometrical parameters were estimated from the articular surfaces of the exoskeleton. Kinematic data of a free walking ant was acquired using high-speed synchronized video cameras. Spatial coordinates of 49 virtual markers were used to run inverse kinematics simulations using the OpenSim software. The sensitivity of the model's predictions to joint geometrical parameters and marker position uncertainties was evaluated by means of two Monte Carlo simulations. The developed model was four times more sensitive to perturbations on marker position than those of the joint geometrical parameters. These results are of interest for locomotion studies of small quadrupeds, octopods, and other multi-legged animals.

6.
Bioinspir Biomim ; 16(4)2021 06 23.
Artículo en Inglés | MEDLINE | ID: mdl-33652422

RESUMEN

One of the biggest issues of the mechanical cylindrical joints is related to premature wear appearing. Application of bioinspiration principles in an engineering context taking advantage of smart solutions offered by nature in terms of kinematic joints could be a way of solving those problems. This work is focussed on joints of one degrees of freedom in rotation (revolute or ginglymus joints in biological terms), as this is one of the most common type of mechanical joints. This type of joints can be found in the elbow of some quadrupedal mammals. The articular morphology of the elbow of these animals differs in the presence/absence of a trochlear sulcus. In this study, bio-inspired mechanical joints based on these morphologies (with/without trochlear sulcus) were designed and numerically tested. Their load bearing performance was numerically analysed. This was done through contact simulations using the finite element method under different external loading conditions (axial load, radial load and turnover moment). Results showed that the tested morphologies behave differently in transmission of external mechanical loads. It was found that bio-inspired joints without trochlea sulcus showed to be more specialized in the bearing of turnover moments. Bio-inspired joints with trochlea sulcus are more suitable for supporting combined loads (axial and radial load and turnover moments). Learning about the natural rules of mechanical design can provide new insights to improve the design of current mechanical joints.


Asunto(s)
Miembro Anterior , Mamíferos , Soporte de Peso , Animales , Fenómenos Biomecánicos , Análisis de Elementos Finitos , Rango del Movimiento Articular
7.
Sci Rep ; 10(1): 5277, 2020 03 24.
Artículo en Inglés | MEDLINE | ID: mdl-32210280

RESUMEN

Arthroplasty is a surgical procedure to restore the function of the joint of patient suffering from knee osteoarthritis. However, postoperative functional deficits are reported even after a rehabilitation program. In order to determine the origin of functional deficits of patient suffering from knee osteoarthritis and total knee arthroplasty, we developed a rodent model including a chemically-induced-osteoarthritis and designed a knee prosthesis (Ti6Al4V/PEEK) biomechanically and anatomically adapted to rat knee joint. Dynamic Weight-Bearing, gait kinematics, H-reflex from vastus medialis muscle and activities from metabosensitive III and IV afferent fibers in femoral nerve were assessed at 1 and 3 months post-surgery. Results indicate that knee osteoarthritis altered considerably the responses of afferent fibers to their known activators (i.e., lactic acid and potassium chloride) and consequently their ability to modulate the spinal sensorimotor loop, although, paradoxically, motor deficits seemed relatively light. On the contrary, results indicate that, after the total knee arthroplasty, the afferent responses and the sensorimotor function were slightly altered but that motor deficits were more severe. We conclude that neural changes attested by the recovery of the metabosensitive afferent activity and the sensorimotor loop were induced when a total knee replacement was performed and that these changes may disrupt or delay the locomotor recovery.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Cetonas , Prótesis de la Rodilla , Osteoartritis de la Rodilla/cirugía , Polietilenglicoles , Titanio , Vías Aferentes/fisiología , Aleaciones , Animales , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Benzofenonas , Modelos Animales de Enfermedad , Nervio Femoral/lesiones , Nervio Femoral/fisiopatología , Marcha , Trastornos Neurológicos de la Marcha/etiología , Trastornos Neurológicos de la Marcha/fisiopatología , Reflejo H , Ácido Yodoacético/toxicidad , Masculino , Músculo Esquelético/fisiopatología , Osteoartritis de la Rodilla/inducido químicamente , Traumatismos de los Nervios Periféricos/etiología , Traumatismos de los Nervios Periféricos/fisiopatología , Polímeros , Complicaciones Posoperatorias/etiología , Distribución Aleatoria , Ratas , Recuperación de la Función , Soporte de Peso
8.
J Biomech ; 104: 109724, 2020 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-32156444

RESUMEN

In musculoskeletal modelling, adjusting model parameters is challenging. This paper proposes a multivariate statistical methodology to adjust muscle force-generating parameters optimally. Dynamic residuals are minimized as muscle force-generating parameters are varied (maximal isometric force, optimal fiber length, tendon slack length and pennation angle).First, a sensitivity and a Pareto analyses are carried out in order to sort out and screen the set of parameters having the greatest influence regarding the dynamic residuals. These parameters are then used to create a response surface following a Design of Experiments (DoE) approach. Finally, this surface is used to determine the optimum levels of the design variables (muscle force-generating parameters). The proposed methodology is illustrated by the adjustment of a three-dimensional musculoskeletal model of a sheep forelimb. After adjustment, the reserve actuator values of the elbow and wrist joints were reduced, on average, by 18%, and 16%, respectively. These results demonstrate that the use of multivariate statistical strategies is an effective way to adjust model parameters optimally while reducing dynamic inconsistencies. This study constitutes a step towards a more robust methodology in musculoskeletal modelling, focusing on muscular parameter tuning.


Asunto(s)
Modelos Biológicos , Músculo Esquelético , Animales , Miembro Anterior , Contracción Isométrica , Ovinos , Tendones , Extremidad Superior
9.
PLoS One ; 14(3): e0213100, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30835751

RESUMEN

Looking for new opportunities in mechanical design, we are interested in studying the kinematic behaviour of biological joints. The real kinematic behaviour of the elbow of quadruped animals (which is submitted to high mechanical stresses in comparison with bipeds) remains unexplored. The sheep elbow joint was chosen because of its similarity with a revolute joint. The main objective of this study is to estimate the effects of elbow simplifications on the prediction of joint reaction forces in inverse dynamic simulations. Rigid motions between humerus and radius-ulna were registered during full flexion-extension gestures on five cadaveric specimens. The experiments were initially conducted with fresh specimens with ligaments and repeated after removal of all soft tissue, including cartilage. A digital image correlation system was used for tracking optical markers fixed on the bones. The geometry of the specimens was digitized using a 3D optical scanner. Then, the instantaneous helical axis of the joint was computed for each acquisition time. Finally, an OpenSim musculoskeletal model of the sheep forelimb was used to quantify effects of elbow joint approximations on the prediction of joint reaction forces. The motion analysis showed that only the medial-lateral translation is sufficiently large regarding the measuring uncertainty of the experiments. This translation assimilates the sheep elbow to a screw joint instead of a revolute joint. In comparison with fresh specimens, the experiments conducted with dry bone specimens (bones without soft tissue) provided different kinematic behaviour. From the results of our inverse dynamic simulations, it was noticed that the inclusion of the medial-lateral translation to the model made up with the mean flexion axis does not affect the predicted joint reaction forces. A geometrical difference between the axis of the best fitting cylinder and the mean flexion axis (derived from the motion analysis) of fresh specimens was highlighted. This geometrical difference impacts slightly the prediction of joint reactions.


Asunto(s)
Miembro Anterior/fisiología , Imagenología Tridimensional/métodos , Animales , Fenómenos Biomecánicos , Simulación por Computador , Femenino , Articulaciones , Rango del Movimiento Articular , Ovinos
10.
J Biomed Mater Res B Appl Biomater ; 106(3): 1156-1164, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-28556590

RESUMEN

Despite the worldwide high prevalence of total joint arthroplasty (TJA), life expectancy of prosthesis remains limited by mechanical and chemical constraint which promote wear debris production, surrounding tissues damage and finally prosthesis loosening. Such results could be amplified by neuro-myoelectrostimulation (NMES; widely used to reduce neuromuscular deficits observed following TJA surgery). It was previously described in an in vivo experiment that interactions between NMES and Ti6Al4V implant are deleterious for both implant and surrounding muscles. The purpose of the present study was to compare the biocompatibility of four common orthopedic biomaterials, two metallic (Ti6Al4V, CrCo) and two nonmetallic (PEEK, Al2 O3 ) alloys, fixed on rat tibial crest in which the surrounding muscles were electrostimulated. Muscle cell death rate was not found significantly increased, with or without electrical stimulation for nonmetallic implants. Contrary to Ti6Al4V alloy, the CrCo implant did not induce destruction of the surrounding muscle. However, cell viability decreased for both metallic alloys when NMES was applied but within a greater significant extent for Ti6Al4V implant. Otherwise, when NMES was applied, implant-to-bone adhesion significantly decreased for Ti6Al4V while no significant difference was found for PEEK, Al2 O3 , and CrCo. Statistical analyses reveal also a lesser adhesion strength for Ti6Al4V compared with CrCo when NMES was applied. Selecting the most suitable material in term of biocompatibility remains a major concern and non-metallic materials seems to be more appropriated in regard to electrical currents used for post TJA care. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1156-1164, 2018.


Asunto(s)
Materiales Biocompatibles , Estimulación Eléctrica , Ensayo de Materiales , Adhesividad , Aleaciones , Óxido de Aluminio/química , Animales , Artroplastia de Reemplazo , Benzofenonas , Huesos/patología , Supervivencia Celular , Cetonas/química , Masculino , Fibras Musculares Esqueléticas/patología , Músculo Esquelético/fisiología , Polietilenglicoles/química , Polímeros , Diseño de Prótesis , Ratas , Ratas Sprague-Dawley , Titanio/química
11.
J Biomed Mater Res B Appl Biomater ; 106(1): 104-111, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27875027

RESUMEN

New fusionless devices are being developed to get over the limits of actual spinal surgical treatment, based on arthrodesis. However, due to their recentness, no standards exist to test and validate those devices, especially concerning the wear. A new tribological first approach to the definition of an in vitro wear protocol to study wear of flexible and sliding spinal devices is presented in this article, and was applied to a new concept. A simplified synthetic spine portion (polyethylene) was developed to reproduce a simple supra-physiological spinal flexion (10° between two vertebrae). The device studied with this protocol was tested in wet environment until 1 million cycles (Mc). We obtained an encouraging estimated wear volume of same order of magnitude compared to similar devices. An associated finite element (FE) numerical model has permitted to access contact information and study the effect of misalignment of one screw. First results could point out how to improve the design and suggest that a vertical misalignment of a screw (under or over-screwing) has more impact than a horizontal one. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 104-111, 2018.


Asunto(s)
Implantes Experimentales , Modelos Biológicos , Columna Vertebral , Análisis de Elementos Finitos , Humanos
12.
Int J Mol Sci ; 18(7)2017 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-28696371

RESUMEN

Nowadays, salt consumption appears to be drastically above the recommended level in industrialized countries. The health consequences of this overconsumption are heavy since high-salt intake induces cardiovascular disease, kidney dysfunction, and stroke. Moreover, harmful interaction may also occur with orthopaedic devices because overconsumption of salt reinforces the corrosive aspect of biological tissues and favors bone resorption process. In the present study, we aimed to assess the in vivo effect of three weeks of a high-salt diet, associated (or not) with two weeks of the neuro-myoelectrostimulation (NMES) rehabilitation program on the biocompatibility of four biomaterials used in the manufacture of arthroplasty implants. Thus, two non-metallic (PEEK and Al2O3) and two metallic (Ti6Al4V and CrCo) compounds were implanted in the rat tibial crest, and the implant-to-bone adhesion and cell viability of two surrounded muscles, the Flexor Digitorum (FD) and Tibialis Anterior (TA), were assessed at the end of the experiment. Results indicated lower adhesion strength for the PEEK implant compared to other biomaterials. An effect of NMES and a high-salt diet was only identified for Al2O3 and Ti6Al4V implants, respectively. Moreover, compared to a normal diet, a high-salt diet induced a higher number of dead cells on both muscles for all biomaterials, which was further increased for PEEK, Al2O3, and CrCo materials with NMES application. Finally, except for Ti6Al4V, NMES induced a higher number of dead cells in the directly stimulated muscle (FD) compared to the indirectly stimulated one (TA). This in vivo experiment highlights the potential harmful effect of a high-salt diet for people who have undergone arthroplasty, and a rehabilitation program based on NMES.


Asunto(s)
Materiales Biocompatibles/química , Cloruro de Sodio Dietético/efectos adversos , Aleaciones , Óxido de Aluminio/química , Animales , Benzofenonas , Supervivencia Celular/efectos de los fármacos , Humanos , Cetonas/química , Masculino , Polietilenglicoles/química , Polímeros , Ratas , Ratas Sprague-Dawley , Titanio/química
13.
PLoS One ; 11(1): e0146873, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26761710

RESUMEN

AIM OF THE STUDY: High-salt consumption has been widely described as a risk factor for cardiovascular, renal and bone functions. In the present study, the extent to which high-salt diet could influence Ti6Al4V implant surface characteristic, its adhesion to rat tibial crest, and could modify muscle cell viability of two surrounding muscles, was investigated in vivo. These parameters have also been assessed following a NMES (neuro-myoelectrostimulation) program similar to that currently used in human care following arthroplasty. RESULTS: After a three-week diet, a harmful effect on titanium implant surface and muscle cell viability was noted. This is probably due to salt corrosive effect on metal and then release of toxic substance around biologic tissue. Moreover, if the use of NMES with high-salt diet induced muscles damages, the latter were higher when implant was added. Unexpectedly, higher implant-to-bone adhesion was found for implanted animals receiving salt supplementation. CONCLUSION: Our in vivo study highlights the potential dangerous effect of high-salt diet in arthroplasty based on titanium prosthesis. This effect appears to be more important when high-salt diet is combined with NMES.


Asunto(s)
Músculos/fisiología , Prótesis e Implantes , Cloruro de Sodio Dietético/efectos adversos , Titanio/química , Aleaciones , Animales , Artroplastia , Presión Sanguínea , Supervivencia Celular , Materiales Biocompatibles Revestidos , Dieta , Estimulación Eléctrica , Masculino , Músculos/patología , Oseointegración/fisiología , Implantación de Prótesis , Ratas , Ratas Sprague-Dawley , Factores de Riesgo , Propiedades de Superficie , Tibia/patología
14.
J Biomed Mater Res B Appl Biomater ; 103(8): 1594-601, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25533414

RESUMEN

Electrical currents have deleterious effects on biomedical metallic implants. However, following arthroplasty, neuro-myoelectrostimulation (NMES) is often used in patient rehabilitation. Such a rehabilitation technique could compromise patient recovery through deleterious effects on metallic alloys and biological tissues. The purpose of our study was to assess the effects of NMES on a Ti6Al4V implant placed in a rat tibial crest and the surrounding muscle tissues. This in vivo study allowed to bring to the fore the prosthesis behavior under mechanical and electromagnetic loads induced by NEMS stimulation. After 3 weeks, implant-to-bone adhesion significantly decreased in stimulated animals compared with nonstimulated animals. Surface mapping indicated titanium implant degradation after NMES. Furthermore, NMES alone did not induce muscle damage contrary to that found in implanted animals. The muscle damage rate was significantly higher in implanted and stimulated animals compared with implanted-only animals. It seems obvious that rehabilitation programs using the NMES technique could induce early deterioration of biomaterial employed for surgical implants. Clinicians should reconsider the use of NMES as a rehabilitation technique for patients with titanium prostheses.


Asunto(s)
Sustitutos de Huesos , Ensayo de Materiales , Células Musculares/metabolismo , Músculo Esquelético/metabolismo , Prótesis e Implantes , Tibia/metabolismo , Titanio , Aleaciones , Animales , Células Musculares/patología , Músculo Esquelético/patología , Ratas , Tibia/patología