Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Chromatographia ; 79(17): 1131-1141, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27616782

RESUMEN

Bosentan monohydrate (4-tert-butyl-N-[6-(2-hydroxyethoxy)-5-(2-methoxyphenoxy)-2-(pyrimidin-2-yl) pyrimidin-4-yl]benzene-1-sulfonamide monohydrate) is a dual endothelin receptor antagonist (ERA) applied in the treatment of pulmonary arterial hypertension. To achieve effective process control of the bosentan monohydrate synthesis, it was necessary to develop a selective and not highly time-consuming method for ultra-high performance liquid chromatography (UHPLC). The method is characterized by adequate sensitivity, reproducibility and selectivity for the determination of bosentan monohydrate and related compounds from all synthetic stages. The UHPLC separation was carried out by reversed phase chromatography on the Acquity BEH C18 column (100 mm × 2.1 mm, 1.7 µm) with a mobile phase composed of solvent A (0.1 %, v/v, acetic acid in water) and solvent B (methanol), in the gradient mode at the flow rate of 0.4 mL min-1. Limits of detection and quantification for the compounds were ≤0.1 µg mL-1 and 0.3 µg mL-1, respectively. The linearity for all related compounds was investigated as in the range for the active pharmaceutical ingredient (API) and as in the range for the in-process control. The developed method was validated according to the current guidelines, proving the suitability of the method for its intended purpose.

2.
J Pharm Biomed Anal ; 91: 1-6, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24406462

RESUMEN

The study is a proposition of the application of high performance liquid chromatography (HPLC) with a spectrophotometric UV range detector to analyze the chemical purity and assay of nepafenac, an active pharmaceutical ingredient (API). During literature search only a few publications were found about nepafenac. HPLC UV methods were mainly presented in patent documents about nepafenac synthesis and chemical purity. The presented method allows to separate all potential related compounds from nepafenac and to quantitate the nepafenac amount. As there is no official monograph in the pharmacopeias about nepafenac, the performed full validation procedure makes the method ready to use in routine analysis. The composition of the mobile phase (10mM ammonium formate, pH 4.1) and the HPLC column (Phenomenex Gemini-NX C18) were selected during the development step. Presented data confirm the benefits of the developed method. Four of the most potential impurities were validated as for the quantitative test and the rest of impurities were validated as for the limit test - according to ICH Q2(R1). The accuracy/recovery results for the chemical purity method are within 90-108%, in the case of assay studies from 99% to 101%; the limit of detection is as low as 15-30ng/mL. The linearity passes all statistical tests.


Asunto(s)
Bencenoacetamidas/química , Cromatografía Líquida de Alta Presión/métodos , Contaminación de Medicamentos , Fenilacetatos/química , Espectrofotometría/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA