1.
Br J Radiol ; 92(1103): 20190384, 2019 Nov.
Article En | MEDLINE | ID: mdl-31479307

OBJECTIVE: Evaluation of coronary CT image blur using multi segment reconstruction algorithm. METHODS: Cardiac motion was simulated in a Catphan. CT coronary angiography was performed using 320 × 0.5 mm detector array and 275 ms gantry rotation. 1, 2 and 3 segment reconstruction algorithm, three heart rates (60, 80 and 100bpm), two peak displacements (4, 8 mm) and three cardiac phases (55, 35, 75%) were used. Wilcoxon test compared image blur from the different reconstruction algorithms. RESULTS: Image blur for 1, 2 and 3 segments in: 60 bpm, 75% R-R interval and 8 mm peak displacement: 0.714, 0.588, 0.571 mm (1.18, 0.6, 0.4 mm displacement) 80 bpm, 35% R-R interval and 8 mm peak displacement: 0.869, 0.606, 0.606 mm (1.57, 0.79,0.52 mm displacement) 100 bpm, 35% R-R interval and 4 mm peak displacement: 0.645, 0.588, 0.571 mm (0.98, 0.49, 0.33 mm displacement). The median image blur overall for 1 and 2 segments was 0.714 mm and 0.588 mm respectively (p < 0.0001). CONCLUSION: Two-segment reconstruction significantly reduces image blur. ADVANCES IN KNOWLEDGE: Multisegment reconstruction algorithms during CT coronary angiography are a useful method to reduce image blur, improve visualization of the coronary artery wall and help the early detection of the plaque.


Computed Tomography Angiography/standards , Coronary Artery Disease/diagnostic imaging , Algorithms , Analysis of Variance , Artifacts , Coronary Artery Disease/physiopathology , Heart Rate/physiology , Humans , Movement , Phantoms, Imaging , Pilot Projects , Prospective Studies , Radiographic Image Enhancement/methods
2.
J Comput Assist Tomogr ; 42(2): 240-247, 2018.
Article En | MEDLINE | ID: mdl-28937481

OBJECTIVE: The study aims to optimize visualization of the coronary wall during computed tomography coronary angiography. METHODS: A coronary plaque phantom was scanned on a wide-volume computed tomography scanner. Spatial resolution, contrast resolution, and vessel wall thickness were measured at different x-ray tube currents and voltages. RESULTS: Spatial resolution ranged from 0.385 to 0.625 mm and was significantly lower at higher currents. Contrast-to-noise ratio was significantly higher at higher currents. The most accurate wall thickness measurements were quantified at 300 and 400 mA for 80 and 100 kVp and 300 mA for 120 and 135 kVp. CONCLUSIONS: Lower spatial resolution at higher currents was due to added blur from increased focal spot size. Contrast-to-noise ratio was higher at higher currents owing to decreased quantum noise. Wall thickness was measured more accurately at intermediate currents with midrange contrast-to-noise ratio but optimal spatial resolution. For accurate coronary wall thickness measurement, contrast-to-noise ratio is compromised to achieve optimal spatial resolution.


Coronary Angiography/methods , Phantoms, Imaging , Plaque, Atherosclerotic/diagnostic imaging , Tomography, X-Ray Computed/methods , Reproducibility of Results
3.
J Endovasc Ther ; 24(1): 35-46, 2017 02.
Article En | MEDLINE | ID: mdl-27659155

PURPOSE: To test and validate magnetic resonance imaging (MRI) sequences for peripheral artery lesion characterization and relate the MRI characteristics to the amount of force required for a guidewire to puncture peripheral chronic total occlusions (CTOs) as a surrogate for immediate failure of endovascular therapy. METHODS: Diseased superficial femoral, popliteal, and tibial artery segments containing 55 atherosclerotic lesions were excised from the amputated limbs of 7 patients with critical limb ischemia. The lesions were imaged at high resolution (75 µm3 voxels) with T2-weighted (T2W) and ultrashort echo time (UTE) sequences on a 7-T MR scanner. The MR images (n=15) were validated with micro-computed tomography and histology. CTOs (n=40) were classified by their MR signal characteristics as "soft" (signals indicating fat, thrombus, microchannels, or loose fibrous tissue), "hard" (collagen and/or speckled calcium signals), or "calcified" (calcified nodule signals). A 2-kg load cell advanced the back end of a 0.035-inch stiff guidewire at a fixed displacement rate (0.05 mm/s) through the CTOs, and the forces required to cross each lesion were measured. RESULTS: T2W images showed fat as hyperintense and hardened tissue as hypointense. Calcium and thrombus appeared as a signal void in conventional MRI sequences but were easily identified in UTE images (thrombus was hyperintense and calcium hypointense). MRI accurately differentiated "hard," "soft," and "calcified" CTOs based on associated guidewire puncture force. The guidewire could not enter "calcified" CTOs (n=6) at all. "Hard" CTOs (n=9) required a significantly higher (p<0.001) puncture force of 1.71±0.51 N vs 0.43±0.36 N for "soft" CTOs (n=25). CONCLUSION: MRI characteristics of PAD lesions correlate with guidewire puncture forces, an important aspect of crossability. Future work will determine if clinical MR scanners can be used to predict success in peripheral vascular interventions.


Endovascular Procedures , Femoral Artery/diagnostic imaging , Magnetic Resonance Imaging , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/therapy , Plaque, Atherosclerotic , Popliteal Artery/diagnostic imaging , Tibial Arteries/diagnostic imaging , Vascular Calcification/diagnostic imaging , Vascular Calcification/therapy , Aged , Aged, 80 and over , Clinical Decision-Making , Female , Femoral Artery/pathology , Humans , Male , Middle Aged , Patient Selection , Peripheral Arterial Disease/pathology , Popliteal Artery/pathology , Predictive Value of Tests , Punctures , Reproducibility of Results , Tibial Arteries/pathology , Vascular Calcification/pathology
4.
NMR Biomed ; 28(10): 1236-44, 2015 Oct.
Article En | MEDLINE | ID: mdl-26268158

Although current cardiovascular MR (CMR) techniques for the detection of myocardial fibrosis have shown promise, they nevertheless depend on gadolinium-based contrast agents and are not specific to collagen. In particular, the diagnosis of diffuse myocardial fibrosis, a precursor of heart failure, would benefit from a non-invasive imaging technique that can detect collagen directly. Such a method could potentially replace the need for endomyocardial biopsy, the gold standard for the diagnosis of the disease. The objective of this study was to measure the MR properties of collagen using ultrashort TE (UTE), a technique that can detect short T2* species. Experiments were performed in collagen solutions. Via a model of bi-exponential T2* with oscillation, a linear relationship (slope = 0.40 ± 0.01, R(2) = 0.99696) was determined between the UTE collagen signal fraction associated with these properties and the measured collagen concentration in solution. The UTE signal of protons in the collagen molecule was characterized as having a mean T2* of 0.75 ± 0.05 ms and a mean chemical shift of -3.56 ± 0.01 ppm relative to water at 7 T. The results indicated that collagen can be detected and quantified using UTE. A knowledge of the collagen signal properties could potentially be beneficial for the endogenous detection of myocardial fibrosis.


Collagen Type III/chemistry , Collagen Type I/chemistry , Magnetic Resonance Spectroscopy , Animals , Cattle , Endomyocardial Fibrosis/diagnosis , Endomyocardial Fibrosis/metabolism , Feasibility Studies , Humans , In Vitro Techniques , Protons , Solutions
5.
J Cardiovasc Magn Reson ; 16: 12, 2014 Jan 24.
Article En | MEDLINE | ID: mdl-24460958

BACKGROUND: Electrocardiogram (ECG) gating is commonly used to synchronize imaging windows to diastasis periods over multiple heartbeats in magnetic resonance (MR) coronary angiography. Calibration of the ECG gating parameters is typically based on a cine cardiovascular MR (CMR) video of the beating heart. Insufficient temporal resolution in the cine-CMR method, however, may produce gating errors and motion artifacts.It was previously shown that tissue Doppler echocardiography (TDE) can identify accurate diastasis window timings by observing the movement of the interventricular septum (IVS). We present a new CMR technique, the Septal Scout, for measuring IVS motion. We demonstrate that cardiac gating windows determined by the Septal Scout produce sharper coronary MR angiography images than windows determined by cine-CMR. METHODS: 9 healthy volunteers were scanned on a GE Optima 450w 1.5T MR system. Cine-CMR was acquired and used to identify the start and end times of the diastasis window (Wcine). The Septal Scout employs a one-dimensional steady-state free precession (SSFP) readout along the ventricular septum prescribed from the 4-chamber view. The Septal Scout data is processed to produce a septal velocity function, from which the diastasis window was determined (Wsep). Non-contrast-enhanced MR angiography was performed twice for each volunteer: once gated to Wcine, once to Wsep. Vessel sharpness was assessed subjectively by two experienced observers, and quantitatively by full width half maximum (FWHM) measurements of cross-sectional vessel profiles. In addition, TDE was performed on a subcohort of 6 volunteers where diastasis windows (WTDE) were determined from the IVS velocity measured in the 4-chamber view. Wsep and WTDE were compared using Pearson's correlation. RESULTS: MRA acquisitions were successful in all volunteers. Vessel segments produced smaller FWHM measurements and were deemed sharper when imaged during the Septal Scout gating windows (p < 0.05). Subjective assessment of sharpness also improved for the Septal Scout-gated scans (p < 0.01 for both observers). Lastly, Wsep and WTDE were highly correlated (R > 0.98, p < 0.001). CONCLUSIONS: The MR Septal Scout technique was introduced and demonstrated to be more accurate at determining cardiac gating windows than cine-CMR, yielding sharper coronary MR angiography images.


Cardiac-Gated Imaging Techniques , Coronary Angiography/methods , Electrocardiography , Heart Rate , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Angiography , Ventricular Septum/physiology , Adult , Diastole , Echocardiography, Doppler , Healthy Volunteers , Humans , Magnetic Resonance Imaging, Cine , Male , Observer Variation , Predictive Value of Tests , Reproducibility of Results , Ventricular Septum/diagnostic imaging
6.
Med Phys ; 39(6): 3009-18, 2012 Jun.
Article En | MEDLINE | ID: mdl-22755685

PURPOSE: Currently, the use of cine magnetic resonance imaging (MRI) to identify cardiac quiescent periods relative to the electrocardiogram (ECG) signal is insufficient for producing submillimeter-resolution coronary MR angiography (MRA) images. In this work, the authors perform a time series comparison between tissue Doppler echocardiograms of the interventricular septum (IVS) and concurrent biplane x-ray angiograms. Our results indicate very close agreement between the diastasis gating windows identified by both the IVS and x-ray techniques. METHODS: Seven cath lab patients undergoing diagnostic angiograms were simultaneously scanned during a breath hold by ultrasound and biplane x-ray for six to eight heartbeats. The heart rate of each patient was stable. Dye was injected into either the left or right-coronary vasculature. The IVS was imaged using color tissue Doppler in an apical four-chamber view. Diastasis was estimated on the IVS velocity curve. On the biplane angiograms, proximal, mid, and distal regions were identified on the coronary artery (CA). Frame by frame correlation was used to derive displacement, and then velocity, for each region. The quiescent periods for a CA and its subsegments were estimated based on velocity. Using Pearson's correlation coefficient and Bland-Altman analysis, the authors compared the start and end times of the diastasis windows as estimated from the IVS and CA velocities. The authors also estimated the vessel blur across the diastasis windows of multiple sequential heartbeats of each patient. RESULTS: In total, 17 heartbeats were analyzed. The range of heart rate observed across patients was 47-79 beats per minute (bpm) with a mean of 57 bpm. Significant correlations (R > 0.99; p < 0.01) were observed between the IVS and x-ray techniques for the identification of the start and end times of diastasis windows. The mean difference in the starting times between IVS and CA quiescent windows was -12.0 ms. The mean difference in end times between IVS and CA quiescent windows was -3.5 ms. In contrast, the correlation between RR interval and both the start and duration of the x-ray gating windows were relatively weaker: R = 0.63 (p = 0.13) and R = 0.86 (p = 0.01). For IVS gating windows, the average estimated vessel blurs during single and multiple heartbeats were 0.5 and 0.66 mm, respectively. For x-ray gating windows, the corresponding values were 0.26 and 0.44 mm, respectively. CONCLUSIONS: In this study, the authors showed that IVS velocity can be used to identify periods of diastasis for coronary arteries. Despite variability in mid-diastolic rest positions over multiple steady rate heartbeats, vessel blurring of 0.5-1 mm was found to be achievable using the IVS gating technique. The authors envision this leading to a new cardiac gating system that, compared with conventional ECG gating, provides better resolution and shorter scan times for coronary MRA.


Coronary Angiography/methods , Echocardiography, Doppler/methods , Ventricular Septum/diagnostic imaging , Coronary Vessels/diagnostic imaging , Heart Rate , Humans , Respiration , Time Factors , Ventricular Septum/physiology
7.
EuroIntervention ; 7(12): 1444-52, 2012 Apr.
Article En | MEDLINE | ID: mdl-22522554

AIMS: To create a large animal coronary chronic total occlusion (CTO) model. Presence of microvessels within the CTO lumen facilitates guidewire crossing. The patterns and time profiles of matrix changes and microvessel formation during coronary CTO maturation are unknown. METHODS AND RESULTS: CTO were created in 15 swine by percutaneous deployment of a collagen plug. Matrix changes were assessed by histology. Intraluminal neovascularisation was assessed by histology and several imaging modalities, including conventional and 3D spin angiography, micro-computed tomography (micro-CT) imaging, and contrast-enhanced magnetic resonance imaging (MRI), at six and 12 weeks following CTO creation. Matrix changes included an intense inflammatory reaction at six weeks which had partially abated by 12 weeks. A proteoglycan-rich matrix at six weeks was partially replaced with collagen by 12 weeks. Similar changes were noted in the proximal cap which was acellular. Three patterns of microvessel formation were identified and defined based on the presence and extent of a "lead" neovessel. No major differences in pattern or extent of neovascularisation were noted between six and 12 weeks. CONCLUSIONS: Heterogeneity in neovascularisation patterns occurs during coronary CTO development in a porcine model. Non-invasive imaging to determine the predominant type of neovascularisation prior to and during CTO revascularisation may improve guidewire crossing success rates. This model may be useful for further exploration of CTO pathophysiology, and may aid in further refinements of in vivo imaging of CTO and development of novel therapeutic approaches to revascularisation of CTO, such as manipulations of the proximal cap, matrix composition, neovessel induction, and device testing.


Coronary Occlusion/etiology , Disease Models, Animal , Animals , Chronic Disease , Coronary Occlusion/diagnostic imaging , Coronary Occlusion/pathology , Coronary Occlusion/therapy , Female , Magnetic Resonance Imaging , Swine , Tomography, X-Ray Computed
8.
Med Image Anal ; 16(2): 505-23, 2012 Feb.
Article En | MEDLINE | ID: mdl-22209561

Cardiac computer models can help us understand and predict the propagation of excitation waves (i.e., action potential, AP) in healthy and pathologic hearts. Our broad aim is to develop accurate 3D MR image-based computer models of electrophysiology in large hearts (translatable to clinical applications) and to validate them experimentally. The specific goals of this paper were to match models with maps of the propagation of optical AP on the epicardial surface using large porcine hearts with scars, estimating several parameters relevant to macroscopic reaction-diffusion electrophysiological models. We used voltage-sensitive dyes to image AP in large porcine hearts with scars (three specimens had chronic myocardial infarct, and three had radiofrequency RF acute scars). We first analyzed the main AP waves' characteristics: duration (APD) and propagation under controlled pacing locations and frequencies as recorded from 2D optical images. We further built 3D MR image-based computer models that have information derived from the optical measures, as well as morphologic MRI data (i.e., myocardial anatomy, fiber directions and scar definition). The scar morphology from MR images was validated against corresponding whole-mount histology. We also compared the measured 3D isochronal maps of depolarization to simulated isochrones (the latter replicating precisely the experimental conditions), performing model customization and 3D volumetric adjustments of the local conductivity. Our results demonstrated that mean APD in the border zone (BZ) of the infarct scars was reduced by ~13% (compared to ~318 ms measured in normal zone, NZ), but APD did not change significantly in the thin BZ of the ablation scars. A generic value for velocity ratio (1:2.7) in healthy myocardial tissue was derived from measured values of transverse and longitudinal conduction velocities relative to fibers direction (22 cm/s and 60 cm/s, respectively). The model customization and 3D volumetric adjustment reduced the differences between measurements and simulations; for example, from one pacing location, the adjustment reduced the absolute error in local depolarization times by a factor of 5 (i.e., from 58 ms to 11 ms) in the infarcted heart, and by a factor of 6 (i.e., from 60 ms to 9 ms) in the heart with the RF scar. Moreover, the sensitivity of adjusted conductivity maps to different pacing locations was tested, and the errors in activation times were found to be of approximately 10-12 ms independent of pacing location used to adjust model parameters, suggesting that any location can be used for model predictions.


Algorithms , Body Surface Potential Mapping/methods , Heart Conduction System/pathology , Heart Conduction System/physiopathology , Magnetic Resonance Imaging, Cine/methods , Microscopy, Fluorescence/methods , Voltage-Sensitive Dye Imaging/methods , Humans , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Models, Anatomic , Models, Cardiovascular , Pattern Recognition, Automated/methods , Reproducibility of Results , Sensitivity and Specificity , Subtraction Technique
9.
Magn Reson Imaging ; 28(1): 95-102, 2010 Jan.
Article En | MEDLINE | ID: mdl-19553052

Self-gating is investigated to improve the velocity resolution of real-time Fourier velocity encoding measurements in the absence of a reliable electrocardiogram waveform (e.g., fetal magnetic resonance or severe arrhythmia). Real-time flow data are acquired using interleaved k-space trajectories which share a common path near the origin of k-space. These common data provide a rapid self-gating signal that can be used to combine the interleaved data. The combined interleaves cover a greater area of k-space than a single real-time acquisition, thereby providing higher velocity resolution for a given aliasing velocity and temporal resolution. For example, this approach provided velocity spectra with a temporal resolution of 19 ms and velocity resolution of 22 cm/s over an 818 cm/s field-of-view. The method was validated experimentally using a computer-controlled pulsatile flow apparatus and applied in vivo to measure aortic-valve flow in a healthy volunteer.


Algorithms , Aortic Valve/anatomy & histology , Aortic Valve/physiology , Blood Flow Velocity/physiology , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Rheology/methods , Fourier Analysis , Humans , Image Enhancement/methods , Phantoms, Imaging , Reproducibility of Results , Sensitivity and Specificity
...