Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Metallomics ; 15(10)2023 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-37715341

RESUMEN

The gadolinium-based contrast agent Gadoxetic acid and the platinum-based antitumor agent Cisplatin were quantitatively imaged in liver and liver cancer (hepatocellular carcinoma, HCC) tissue of rats by means of laser ablation-inductively coupled plasma-mass spectrometry. HCC bearing rats simultaneously received a tail vein injection of the hepatocyte-specific magnetic resonance imaging contrast agent Gadoxetic acid and a transarterial injection of Cisplatin 15 min before sacrifice and liver removal. Resecting HCC with adjacent liver tissue allows the comparison of Gd, Pt, and endogenous elements like Fe, Cu, and Zn in the various tissue types. Region of interest analysis reveals lower concentrations of Gd in HCC and higher Gd content in the adjacent liver, fitting the selective uptake of Gadoxetic acid into hepatocytes. Furthermore, two malignancy grades and their possible impact on the Gadoxetic acid and Cisplatin uptake are compared. For this, four high grade (G3) and two moderate grade (G2) HCCs were analysed, including a control sample each. Gd concentrations were lower in HCC irrespective of the grade of dedifferentiation (G2, G3) compared to adjacent liver. Despite local arterial Cisplatin injection, concentrations of Pt were similar or also reduced in HCC compared to liver tissue. In addition, endogenous Fe, Cu, and Zn were quantified. While Zn was homogenously distributed, higher Fe concentrations were determined in liver tissue compared to HCC. Hotspots of Cu suggest a deregulated copper homeostasis in certain liver lesions. The Gd and Fe distributions are compared in detail with cellular alterations examined by hematoxylin and eosin staining.

2.
Eur Radiol ; 33(10): 6892-6901, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37133518

RESUMEN

OBJECTIVES: To examine the effect of high-b-value computed diffusion-weighted imaging (cDWI) on solid lesion detection and classification in pancreatic intraductal papillary mucinous neoplasm (IPMN), using endoscopic ultrasound (EUS) and histopathology as a standard of reference. METHODS: Eighty-two patients with known or suspected IPMN were retrospectively enrolled. Computed high-b-value images at b = 1000 s/mm2 were calculated from standard (b = 0, 50, 300, and 600 s/mm2) DWI images for conventional full field-of-view (fFOV, 3 × 3 × 4 mm3 voxel size) DWI. A subset of 39 patients received additional high-resolution reduced-field-of-view (rFOV, 2.5 × 2.5 × 3 mm3 voxel size) DWI. In this cohort, rFOV cDWI was compared against fFOV cDWI additionally. Two experienced radiologists evaluated (Likert scale 1-4) image quality (overall image quality, lesion detection and delineation, fluid suppression within the lesion). In addition, quantitative image parameters (apparent signal-to-noise ratio (aSNR), apparent contrast-to-noise ratio (aCNR), contrast ratio (CR)) were assessed. Diagnostic confidence regarding the presence/absence of diffusion-restricted solid nodules was assessed in an additional reader study. RESULTS: High-b-value cDWI at b = 1000 s/mm2 outperformed acquired DWI at b = 600 s/mm2 regarding lesion detection, fluid suppression, aCNR, CR, and lesion classification (p = < .001-.002). Comparing cDWI from fFOV and rFOV revealed higher image quality in high-resolution rFOV-DWI compared to conventional fFOV-DWI (p ≤ .001-.018). High-b-value cDWI images were rated non-inferior to directly acquired high-b-value DWI images (p = .095-.655). CONCLUSIONS: High-b-value cDWI may improve the detection and classification of solid lesions in IPMN. Combining high-resolution imaging and high-b-value cDWI may further increase diagnostic precision. CLINICAL RELEVANCE STATEMENT: This study shows the potential of computed high-resolution high-sensitivity diffusion-weighted magnetic resonance imaging for solid lesion detection in pancreatic intraductal papillary mucinous neoplasia (IPMN). The technique may enable early cancer detection in patients under surveillance. KEY POINTS: • Computed high-b-value diffusion-weighted imaging (cDWI) may improve the detection and classification of intraductal papillary mucinous neoplasms (IPMN) of the pancreas. • cDWI calculated from high-resolution imaging increases diagnostic precision compared to cDWI calculated from conventional-resolution imaging. • cDWI has the potential to strengthen the role of MRI for screening and surveillance of IPMN, particularly in view of the rising incidence of IPMNs combined with now more conservative therapeutic approaches.


Asunto(s)
Neoplasias Intraductales Pancreáticas , Neoplasias Pancreáticas , Humanos , Estudios Retrospectivos , Neoplasias Pancreáticas/diagnóstico por imagen , Relación Señal-Ruido , Imagen de Difusión por Resonancia Magnética/métodos , Páncreas
3.
Cancers (Basel) ; 14(3)2022 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-35158737

RESUMEN

BACKGROUND: Our purpose was to investigate the potential of high-resolution, high b-value computed DWI (cDWI) in pancreatic ductal adenocarcinoma (PDAC) detection. MATERIALS AND METHODS: We retrospectively enrolled 44 patients with confirmed PDAC. Respiratory-triggered, diffusion-weighted, single-shot echo-planar imaging (ss-EPI) with both conventional (i.e., full field-of-view, 3 × 3 × 4 mm voxel size, b = 0, 50, 300, 600 s/mm2) and high-resolution (i.e., reduced field-of-view, 2.5 × 2.5 × 3 mm voxel size, b = 0, 50, 300, 600, 1000 s/mm2) imaging was performed for suspected PDAC. cDWI datasets at b = 1000 s/mm2 were generated for the conventional and high-resolution datasets. Three radiologists were asked to subjectively rate (on a Likert scale of 1-4) the following metrics: image quality, lesion detection and delineation, and lesion-to-pancreas intensity relation. Furthermore, the following quantitative image parameters were assessed: apparent signal-to-noise ratio (aSNR), contrast-to-noise ratio (aCNR), and lesion-to-pancreas contrast ratio (CR). RESULTS: High-resolution, high b-value computed DWI (r-cDWI1000) enabled significant improvement in lesion detection and a higher incidence of a high lesion-to-pancreas intensity relation (type 1, clear hyperintense) compared to conventional high b-value computed and high-resolution high b-value acquired DWI (f-cDWI1000 and r-aDWI1000, respectively). Image quality was rated inferior in the r-cDWI1000 datasets compared to r-aDWI1000. Furthermore, the aCNR and CR were higher in the r-cDWI1000 datasets than in f-cDWI1000 and r-aDWI1000. CONCLUSION: High-resolution, high b-value computed DWI provides significantly better visualization of PDAC compared to the conventional high b-value computed and high-resolution high b-value images acquired by DWI.

4.
EJNMMI Res ; 11(1): 70, 2021 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-34322781

RESUMEN

PURPOSE: In this prospective exploratory study, we evaluated the feasibility of [18F]fluorodeoxyglucose ([18F]FDG) PET/MRI-based chemotherapy response prediction in pancreatic ductal adenocarcinoma at two weeks upon therapy onset. MATERIAL AND METHODS: In a mixed cohort, seventeen patients treated with chemotherapy in neoadjuvant or palliative intent were enrolled. All patients were imaged by [18F]FDG PET/MRI before and two weeks after onset of chemotherapy. Response per RECIST1.1 was then assessed at 3 months [18F]FDG PET/MRI-derived parameters (MTV50%, TLG50%, MTV2.5, TLG2.5, SUVmax, SUVpeak, ADCmax, ADCmean and ADCmin) were assessed, using multiple t-test, Man-Whitney-U test and Fisher's exact test for binary features. RESULTS: At 72 ± 43 days, twelve patients were classified as responders and five patients as non-responders. An increase in ∆MTV50% and ∆ADC (≥ 20% and 15%, respectively) and a decrease in ∆TLG50% (≤ 20%) at 2 weeks after chemotherapy onset enabled prediction of responders and non-responders, respectively. Parameter combinations (∆TLG50% and ∆ADCmax or ∆MTV50% and ∆ADCmax) further improved discrimination. CONCLUSION: Multiparametric [18F]FDG PET/MRI-derived parameters, in particular indicators of a change in tumor glycolysis and cellularity, may enable very early chemotherapy response prediction. Further prospective studies in larger patient cohorts are recommended to their clinical impact.

5.
Cancers (Basel) ; 13(9)2021 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-33922981

RESUMEN

BACKGROUND: PDAC remains a tumor entity with poor prognosis and a 5-year survival rate below 10%. Recent research has revealed invasive biomarkers, such as distinct molecular subtypes, predictive for therapy response and patient survival. Non-invasive prediction of individual patient outcome however remains an unresolved task. METHODS: Discrete cellularity regions of PDAC resection specimen (n = 43) were analyzed by routine histopathological work up. Regional tumor cellularity and CT-derived Hounsfield Units (HU, n = 66) as well as iodine concentrations were regionally matched. One-way ANOVA and pairwise t-tests were performed to assess the relationship between different cellularity level in conventional, virtual monoenergetic 40 keV (monoE 40 keV) and iodine map reconstructions. RESULTS: A statistically significant negative correlation between regional tumor cellularity in histopathology and CT-derived HU from corresponding image regions was identified. Radiological differentiation was best possible in monoE 40 keV CT images. However, HU values differed significantly in conventional reconstructions as well, indicating the possibility of a broad clinical application of this finding. CONCLUSION: In this study we establish a novel method for CT-based prediction of tumor cellularity for in-vivo tumor characterization in PDAC patients.

6.
Acad Radiol ; 28 Suppl 1: S234-S243, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-33390324

RESUMEN

RATIONALE AND OBJECTIVES: To investigate the effects of a reduced field-of-view (rFOV) acquisition in diffusion-weighted magnetic resonance imaging of the pancreas. MATERIALS AND METHODS: We enrolled 153 patients who underwent routine clinical MRI work-up including respiratory-triggered diffusion-weighted single-shot echo-planar imaging (DWI) with full field-of-view (fFOV, 3 × 3 × 4 mm3 voxel size) and reduced field-of-view (rFOV, 2.5 × 2.5 × 3 mm3 voxel size) for suspected pancreatic pathology. Two experienced radiologists were asked to subjectively rate (Likert Scale 1-4) image quality (overall image quality, lesion conspicuity, anatomical detail, artifacts). In addition, quantitative image parameters were assessed (apparent diffusion coefficient, apparent signal to noise ratio, apparent contrast to noise ratio [CNR]). RESULTS: All subjective metrics of image quality were rated in favor of rFOV DWI images compared to fFOV DWI images with substantial-to-high inter-rater reliability. Calculated ADC values of normal pancreas, pancreatic pathologies and reference tissues revealed no differences between both sequences. Whereas the apparent signal to noise ratio was higher in fFOV images, apparent CNR was higher in rFOV images. CONCLUSION: rFOV DWI provides higher image quality and apparent CNR values, favorable in the analysis of pancreatic pathologies.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Imagen Eco-Planar , Artefactos , Humanos , Páncreas/diagnóstico por imagen , Reproducibilidad de los Resultados
7.
J Clin Med ; 9(5)2020 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-32443442

RESUMEN

The evolving dynamics of coronavirus disease 2019 (COVID-19) and the increasing infection numbers require diagnostic tools to identify patients at high risk for a severe disease course. Here we evaluate clinical and imaging parameters for estimating the need of intensive care unit (ICU) treatment. We collected clinical, laboratory and imaging data from 65 patients with confirmed COVID-19 infection based on polymerase chain reaction (PCR) testing. Two radiologists evaluated the severity of findings in computed tomography (CT) images on a scale from 1 (no characteristic signs of COVID-19) to 5 (confluent ground glass opacities in over 50% of the lung parenchyma). The volume of affected lung was quantified using commercially available software. Machine learning modelling was performed to estimate the risk for ICU treatment. Patients with a severe course of COVID-19 had significantly increased interleukin (IL)-6, C-reactive protein (CRP), and leukocyte counts and significantly decreased lymphocyte counts. The radiological severity grading was significantly increased in ICU patients. Multivariate random forest modelling showed a mean ± standard deviation sensitivity, specificity and accuracy of 0.72 ± 0.1, 0.86 ± 0.16 and 0.80 ± 0.1 and a receiver operating characteristic-area under curve (ROC-AUC) of 0.79 ± 0.1. The need for ICU treatment is independently associated with affected lung volume, radiological severity score, CRP, and IL-6.

8.
J Clin Med ; 9(5)2020 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-32344944

RESUMEN

RATIONALE: Pancreatic ductal adenocarcinoma (PDAC) remains a tumor entity of exceptionally poor prognosis, and several biomarkers are under current investigation for the prediction of patient prognosis. Many studies focus on promoting newly developed imaging biomarkers without a rigorous comparison to other established parameters. To assess the true value and leverage the potential of all efforts in this field, a multi-parametric evaluation of the available biomarkers for PDAC survival prediction is warranted. Here we present a multiparametric analysis to assess the predictive value of established parameters and the added contribution of newly developed imaging features such as biomarkers for overall PDAC patient survival. METHODS: 103 patients with resectable PDAC were retrospectively enrolled. Clinical and histopathological data (age, sex, chemotherapy regimens, tumor size, lymph node status, grading and resection status), morpho-molecular and genetic data (tumor morphology, molecular subtype, tp53, kras, smad4 and p16 genetics), image-derived features and the combination of all parameters were tested for their prognostic strength based on the concordance index (CI) of multivariate Cox proportional hazards survival modelling after unsupervised machine learning preprocessing. RESULTS: The average CIs of the out-of-sample data were: 0.63 for the clinical and histopathological features, 0.53 for the morpho-molecular and genetic features, 0.65 for the imaging features and 0.65 for the combined model including all parameters. CONCLUSIONS: Imaging-derived features represent an independent survival predictor in PDAC and enable the multiparametric, machine learning-assisted modelling of postoperative overall survival with a high performance compared to clinical and morpho-molecular/genetic parameters. We propose that future studies systematically include imaging-derived features to benchmark their additive value when evaluating biomarker-based model performance.

9.
J Clin Med ; 9(3)2020 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-32155990

RESUMEN

To bridge the translational gap between recent discoveries of distinct molecular phenotypes of pancreatic cancer and tangible improvements in patient outcome, there is an urgent need to develop strategies and tools informing and improving the clinical decision process. Radiomics and machine learning approaches can offer non-invasive whole tumor analytics for clinical imaging data-based classification. The retrospective study assessed baseline computed tomography (CT) from 207 patients with proven pancreatic ductal adenocarcinoma (PDAC). Following expert level manual annotation, Pyradiomics was used for the extraction of 1474 radiomic features. The molecular tumor subtype was defined by immunohistochemical staining for KRT81 and HNF1a as quasi-mesenchymal (QM) vs. non-quasi-mesenchymal (non-QM). A Random Forest machine learning algorithm was developed to predict the molecular subtype from the radiomic features. The algorithm was then applied to an independent cohort of histopathologically unclassifiable tumors with distinct clinical outcomes. The classification algorithm achieved a sensitivity, specificity and ROC-AUC (area under the receiver operating characteristic curve) of 0.84 ± 0.05, 0.92 ± 0.01 and 0.93 ± 0.01, respectively. The median overall survival for predicted QM and non-QM tumors was 16.1 and 20.9 months, respectively, log-rank-test p = 0.02, harzard ratio (HR) 1.59. The application of the algorithm to histopathologically unclassifiable tumors revealed two groups with significantly different survival (8.9 and 39.8 months, log-rank-test p < 0.001, HR 4.33). The machine learning-based analysis of preoperative (CT) imaging allows the prediction of molecular PDAC subtypes highly relevant for patient survival, allowing advanced pre-operative patient stratification for precision medicine applications.

10.
Eur J Radiol ; 124: 108848, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32006931

RESUMEN

PURPOSE: To test combined dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and 18F-FDG positron emission tomography (FDG-PET)-derived parameters for prediction of histopathological grading in a rat Diethyl Nitrosamine (DEN)-induced hepatocellular carcinoma (HCC) model. METHODS: 15 male Wistar rats, aged 10 weeks were treated with oral DEN 0.01 % in drinking water and monitored until HCCs were detectable. DCE-MRI and PET were performed consecutively on small animal scanners. 38 tumors were identified and manually segmented based on HCC-specific contrast enhancement patterns. Grading (G2/3: 24 tumors, G1:14 tumors) alongside other histopathological parameters, tumor volume, contrast agent and 18F-FDG uptake metrics were noted. Class imbalance was addressed using SMOTE and collinearity was removed using hierarchical clustering and principal component analysis. A logistic regression model was fit separately to the individual parameter groups (DCE-MRI-derived, PET-derived, tumor volume) and the combined parameters. RESULTS: The combined model using all imaging-derived parameters achieved a mean ± STD sensitivity of 0.88 ± 0.16, specificity of 0.70 ± 0.20 and AUC of 0.90 ± 0.03. No correlation was found between tumor grading and tumor volume, morphology, necrosis, extracellular matrix, immune cell infiltration or underlying liver fibrosis. CONCLUSION: A combination of DCE-MRI- and 18F-FDG-PET-derived parameters provides high accuracy for histopathological grading of hepatocellular carcinoma in a relevant translational model system.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico por imagen , Medios de Contraste , Fluorodesoxiglucosa F18 , Aumento de la Imagen/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Tomografía de Emisión de Positrones/métodos , Animales , Carcinoma Hepatocelular/patología , Modelos Animales de Enfermedad , Hígado/diagnóstico por imagen , Hígado/patología , Neoplasias Hepáticas/patología , Masculino , Clasificación del Tumor , Radiofármacos , Ratas , Ratas Wistar , Sensibilidad y Especificidad , Carga Tumoral
11.
PLoS One ; 14(11): e0224988, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31730658

RESUMEN

OBJECTIVES: To evaluate proton density fat fraction (PDFF) and T2* measurements of the liver with combined parallel imaging (sensitivity encoding, SENSE) and compressed sensing (CS) accelerated chemical shift encoding-based water-fat separation. METHODS: Six-echo Dixon imaging was performed in the liver of 89 subjects. The first acquisition variant used acceleration based on SENSE with a total acceleration factor equal to 2.64 (acquisition labeled as SENSE). The second acquisition variant used acceleration based on a combination of CS with SENSE with a total acceleration factor equal to 4 (acquisition labeled as CS+SENSE). Acquisition times were compared between acquisitions and proton density fat fraction (PDFF) and T2*-values were measured and compared separately for each liver segment. RESULTS: Total scan duration was 14.5 sec for the SENSE accelerated image acquisition and 9.3 sec for the CS+SENSE accelerated image acquisition. PDFF and T2* values did not differ significantly between the two acquisitions (paired Mann-Whitney and paired t-test P>0.05 in all cases). CS+SENSE accelerated acquisition showed reduced motion artifacts (1.1%) compared to SENSE acquisition (12.3%). CONCLUSION: CS+SENSE accelerates liver PDFF and T2*mapping while retaining the same quantitative values as an acquisition using only SENSE and reduces motion artifacts.


Asunto(s)
Aceleración , Adiposidad , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética , Protones , Adulto , Anciano , Anciano de 80 o más Años , Hígado Graso/diagnóstico por imagen , Hígado Graso/patología , Femenino , Hemosiderosis/diagnóstico por imagen , Hemosiderosis/patología , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
12.
Eur J Radiol ; 120: 108675, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31585303

RESUMEN

PURPOSE: To evaluate the performance of a novel camera-based breathing navigation system in respiratory-triggered (CRT) 3D-magnetic resonance cholangiopancreatography (MRCP) at 3T MRI. METHODS: Two 3D-MRCP data sets were acquired subsequently within one imaging session with traditional respiratory belt- (BRT) or camera- (CRT) based triggering in 28 patients. Overall image quality, blurring, motion artifacts and discernibility of the pancreaticobiliary tree (PBT) structures were scored on a 4-point scale retrospectively by 2 radiologists. The contrast ratio between the common bile duct and its adjacent tissue was measured by region-of-interest (ROI) analysis. The signal intensity increase at the duct boundaries was quantified by line profiles to objectify blurring and motion artifacts. The extracted respiratory signal curves were analyzed for signal quality and trigger timing. RESULTS: Total scan time was 72 s for both acquisitions. CRT yielded significantly better ratings in image quality, background suppression, blurring and discernibility of PBT structures compared to BRT. Contrast ratios were significantly higher in CRT (0.94 ±â€¯0.03) than in BRT (0.93 ±â€¯0.03) exams; paired t test P = 0.0017. Line profile slopes through the common bile duct revealed significantly higher values in CRT (42.23 ±â€¯8.74% of maximum intensity/mm) compared to BRT (36.06 ±â€¯8.96% of maximum intensity/mm; paired t test P < 0.0001). Camera-derived respiratory signal curves showed a higher SNR, lower standard deviation of the signal amplitude and less incorrect triggering than the respiratory belt-derived respiratory signal curves. CONCLUSION: Camera-based respiratory triggering significantly improves image quality of 3D-MRCP compared to conventional respiratory belt triggering.


Asunto(s)
Pancreatocolangiografía por Resonancia Magnética/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Enfermedades Pancreáticas/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Artefactos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Movimiento (Física) , Reproducibilidad de los Resultados , Respiración , Estudios Retrospectivos , Adulto Joven
13.
Eur J Radiol ; 115: 53-58, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31084759

RESUMEN

OBJECTIVES: To compare the image quality between compressed sensing (CS) 3D-magnetic resonance cholangiopancreatography (MRCP) using respiratory-triggered (RT) and breath-hold (BH) acquisitions and 2D single-shot breath-hold (SSBH) MRCP at 3 T MRI. METHODS: 53 datasets were retrospectively assessed. 3D-MRCP with CS (RT-CS10, BH-CS24) and 2D-SSBH MRCP were acquired. Overall image quality, blurring/motion artifacts and discernibility of the pancreaticobiliary tree (PBT) structures were scored on a 4-point scale by 2 radiologists. The contrast ratio between the common bile duct and its adjacent tissue was measured by region-of-interest (ROI) analysis. Signal intensity increase at the boundaries of the ducts was quantified by line profiles to objectively characterize blurring and motion artifacts. RESULTS: Total scan duration was 17 s for BH-CS24, 1m12 s for 2D-SSBH and 3m48 s for RT-CS10. Images acquired with CS were consistently rated superior in terms of image quality, background suppression, blurring and discernibility of PBT structures compared to 2D-SSBH images. RT-CS10 was superior to BH-CS24 for all ratings except for blurring. Objective analysis yielded the highest contrast ratio for RT-CS10 (0.91 ± 0.04) followed by BH-C24 (0.88 ± 0.05) and 2D-SSBH (0.85 ± 0.06); one-way ANOVA P < 0.0001. The line-profile slope through the CBD was significantly higher in BH-CS24 (37.91 ± 6.38% of maximum intensity/mm) compared to RT-CS10 (29.46 ± 8.17% of maximum intensity/mm) and on par with 2D-SSBH (35.8 ± 12.30% of maximum intensity/mm); one-way-ANOVA P = 0.017. CONCLUSION: CS allows acquisition of volumetric image data with improved image quality compared to SSBH. CS24 yields substantial gains in acquisition speed while robust towards artifacts, enabling diagnostic image quality with a single breath-hold acquisition.


Asunto(s)
Enfermedades de los Conductos Biliares/patología , Enfermedades Pancreáticas/patología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Análisis de Varianza , Artefactos , Contencion de la Respiración , Pancreatocolangiografía por Resonancia Magnética/métodos , Conducto Colédoco/patología , Femenino , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Movimiento (Física) , Estudios Retrospectivos , Adulto Joven
14.
PLoS One ; 14(1): e0208717, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30601813

RESUMEN

PURPOSE: The purpose of the current study was to compare CT-signs of portal venous confluence infiltration for actual histopathological infiltration of the vein or the tumor/vein interface (TVI) in borderline resectable pancreatic ductal adenocarcinoma (PDAC). METHODS AND MATERIALS: 101 patients with therapy-naïve, primarily resected PDAC of the pancreatic head without arterial involvement were evaluated. The portal venous confluence was assessed for contour irregularity (defined as infiltration) and degree of contact. The sensitivity and specificity of contour irregularity versus tumor to vein contact >180° as well as the combination of the signs for tumor cell infiltration of the vessel wall or TVI was calculated. Overall survival (OS) was compared between groups. RESULTS: Sensitivity and specificity of contour irregularity for identification of tumor infiltration of the portal venous confluence or the TVI was higher compared to tumor to vessel contact >180° for tumor cell infiltration (96%/79% vs. 91%/38% respectively, p<0.001). The combination of the signs increased specificity to 92% (sensitivity 88%). Patients with contour irregularity/ tumor to vein contact >180°/ both signs had significantly worse overall survival (16.2 vs. 26.5 months/ 17.9 vs. 37.4 months/ 18.5 vs. 26.5 months respectively, all p<0.05). CONCLUSION: Portal venous confluence contour irregularity is a strong predictor of actual tumor cell infiltration of the vessel wall or the TVI and should be noted as such in radiological reports.


Asunto(s)
Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/patología , Tomografía Computarizada por Rayos X/métodos , Carcinoma Ductal Pancreático/diagnóstico por imagen , Carcinoma Ductal Pancreático/patología , Femenino , Humanos , Masculino , Neoplasias Pancreáticas/cirugía , Pancreaticoduodenectomía , Estudios Retrospectivos , Sensibilidad y Especificidad , Neoplasias Pancreáticas
15.
Eur Radiol ; 28(12): 4925-4931, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29808428

RESUMEN

PURPOSE: The aim of this study was to evaluate the advantages of dual-layer spectral CT (DLSCT) in detection and staging of head and neck cancer (HNC) as well as the imaging of tumour margins and infiltration depth compared to conventional contrast enhanced CT (CECT). MATERIALS AND METHODS: Thirty-nine patients with a proven diagnosis of HNC were examined with a DLSCT scanner and retrospectively analysed. An age-matched healthy control group of the same size was used. Images were acquired in the venous phase. Virtual monoenergetic 40keV-equivalent (MonoE40) images were compared to CECT-images. Diagnostic confidence for tumour identification and margin detection was rated independently by four experienced observers. The steepness of the Hounsfield unit (HU)-increase at the tumour margin was analysed. External carotid artery branch image reconstructions were performed and their contrast compared to conventional arterial phase imaging. Means were compared using a Student's t-test. ANOVA was used for multiple comparisons. RESULTS: MonoE40 images were superior to CECT-images in tumour detection and margin delineation. MonoE40 showed significantly higher attenuation differences between tumour and healthy tissue compared to CECT-images (p < 0.001). The HU-increase at the boundary of the tumour was significantly steeper in MonoE40 images compared to CECT-images (p < 0.001). Iodine uptake in the tumour was significantly higher compared to healthy tissue (p < 0.001). MonoE40 compared to conventional images allowed visualisation of external carotid artery branches from the venous phase in a higher number of cases (87% vs. 67%). CONCLUSION: DLSCT enables improved detection of primary and recurrent head and neck cancer and quantification of tumour iodine uptake. Improved contrast of MonoE40 compared to conventional reconstructions enables higher diagnostic confidence concerning tumour margin detection and vessel identification. KEY POINTS: • Sensitivity concerning tumour detection are higher using dual-layer spectral-CT than conventional CT. • Lesion to background contrast in DLSCT is significantly higher than in CECT. • DLSCT provides sufficient contrast for evaluation of external carotid artery branches.


Asunto(s)
Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Análisis de Varianza , Arterias Carótidas/diagnóstico por imagen , Estudios de Casos y Controles , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Estadificación de Neoplasias/métodos , Estudios Retrospectivos , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...