Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Interact Cardiovasc Thorac Surg ; 10(2): 217-21, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19884165

RESUMEN

Recently, morphometric measurements of the ascending aorta have been done with ECG-gated multidector computerized tomography (MDCT) to help the development of future novel transcatheter therapies (TCT); nevertheless, the variability of such measurements remains unknown. Thirty patients referred for ECG-gated CT thoracic angiography were evaluated. Continuous reformations of the ascending aorta, perpendicular to the centerline, were obtained automatically with a commercially available computer aided diagnosis (CAD). Then measurements of the maximal diameter were done with the CAD and manually by two observers (separately). Measurements were repeated one month later. The Bland-Altman method, Spearman coefficients, and a Wilcoxon signed-rank test were used to evaluate the variability, the correlation, and the differences between observers. The interobserver variability for maximal diameter between the two observers was up to 1.2 mm with limits of agreement [-1.5, +0.9] mm; whereas the intraobserver limits were [-1.2, +1.0] mm for the first observer and [-0.8, +0.8] mm for the second observer. The intraobserver CAD variability was 0.8 mm. The correlation was good between observers and the CAD (0.980-0.986); however, significant differences do exist (P<0.001). The maximum variability observed was 1.2 mm and should be considered in reports of measurements of the ascending aorta. The CAD is as reproducible as an experienced reader.


Asunto(s)
Aorta/patología , Aortografía/métodos , Electrocardiografía , Interpretación de Imagen Radiográfica Asistida por Computador , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados
2.
Radiol Case Rep ; 5(4): 335, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-27307876

RESUMEN

Foreign bodies in the left atrium are rare events with potential major complications. We describe the percutaneous retrieval of a coil from the left atrium that migrated there during an embolization procedure for a pulmonary arteriovenous malformation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA