Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
1.
Medicina (Kaunas) ; 60(8)2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39202526

RESUMEN

Background and Objectives: This is a propensity-matched, single-center study of limited versus extended resection for type A acute aortic dissection (AAAD). Materials and Methods: This study collected retrospective data for 440 patients with acute type A aortic dissection repairs (limited resection, LR-215; extended resection, ER-225), of which 109 pairs were propensity-matched to LR versus ER. Multivariate analysis was performed for inpatient death, long-term survival and the composite outcome of inpatient death/TIA/stroke. Kaplan-Meier survival curves were compared at 1, 3, 5, 10 and 15 years using the log-rank test. Results: Mean age was 66.9 ± 13 years and mean follow-up was 5.3 ± 4.7 years. A total of 48.9% had LR. In-hospital mortality was 10% (LR: 6% vs. ER: 13.8%, p < 0.01). ER, NYHA class, salvage surgery and additional procedures were predictors of increased mortality in unmatched data. Propensity-matched data showed no difference in TIA/stroke rates, LOS, inpatient mortality or composite outcomes. LR had better survival (LR: 77.1% vs. ER: 51.4%, p < 0.001). ER (OR: 1.97, 95% CI: 1.27, 3.08, p = 0.003) was a significant predictor of worse long-term survival. At 15 years, aortic re-operation was 17% and freedom from re-operation and death was 42%. Conclusions: Type A aortic dissection repair has high mortality and morbidity, although results have improved over two decades. ER was a predictor of worse perioperative results and long-term survival.


Asunto(s)
Disección Aórtica , Humanos , Masculino , Femenino , Anciano , Disección Aórtica/cirugía , Disección Aórtica/mortalidad , Estudios Retrospectivos , Persona de Mediana Edad , Mortalidad Hospitalaria , Puntaje de Propensión , Resultado del Tratamiento , Estimación de Kaplan-Meier , Anciano de 80 o más Años , Análisis Multivariante
2.
Medicina (Kaunas) ; 60(6)2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38929496

RESUMEN

Background and Objectives: Determinants of long-term outcomes after surgery for native mitral valve endocarditis have not been thoroughly investigated. The aim of this study was to assess anatomical, disease, and surgical risk factors for long-term mortality and need of reintervention, in patients undergoing mitral valve surgery for active endocarditis. Materials and Methods: Patients who underwent surgery for active native mitral valve endocarditis at three academic centres, between 2000 and 2022, were analysed. The primary outcome was long-term survival. The secondary outcome was the freedom from mitral reoperation. Survival curves were constructed with Kaplan-Meier methodology. Multivariable Cox regression was used to identify demographic, anatomical, disease, and surgical factors associated with late mortality and reoperation. Results: 335 consecutive patients with active mitral endocarditis were analysed. Two hundred and one patients (70.5%) had infection confined to the valve cusp whereas 89 (25.6%) had invasive disease extended to the annulus and surrounding tissues. Preoperative neurological events occurred at the diagnosis in 52 cases. Streptococci were the most common causative organisms followed by Staphylococcus aureus, Coagulase-negative Staphylococcus, and Enterococcus. Valve repair was performed in 108 patients (32.2%). Survival at 5 and 10 years was 70.1% and 59.2%, respectively. Staphylococcus emerged as an independent predictor of late mortality, along with age, chronic obstructive pulmonary disease, and previous cardiac surgery. Survival was considerably reduced in patients with S. aureus compared with those without (log rank p < 0.001). The type of surgery (repair vs. replacement) did not emerge as a risk factor for late mortality and reoperation. Seventeen patients underwent mitral reoperation during the follow-up. The 5- and 10-year freedom from reoperation was 94.7% and 91.8%, respectively. Conclusions: Active mitral valve endocarditis remains a life-threatening disease with impaired survival. While lesion characteristics influenced surgical decision-making and intraoperative management, their impact on long-term survival and freedom from reintervention appears to be moderated by other factors such as infecting pathogens and patient comorbidities.


Asunto(s)
Válvula Mitral , Humanos , Femenino , Masculino , Persona de Mediana Edad , Válvula Mitral/cirugía , Anciano , Reoperación/estadística & datos numéricos , Factores de Riesgo , Resultado del Tratamiento , Estudios Retrospectivos , Endocarditis/cirugía , Endocarditis/mortalidad , Adulto , Modelos de Riesgos Proporcionales , Estimación de Kaplan-Meier
3.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38598445

RESUMEN

OBJECTIVES: The indications for use, evidence base and experience with the novel noncovered open hybrid surgical stents for acute type A aortic dissection repair for concurrent stabilization of the 'downstream' aorta remains limited. We review the evidence base and the development of these stents. METHODS: Data were collected from Pubmed/Medline literature search to develop and review the evidence base for safety and efficacy of non-covered surgical stents. Existing guidelines for use and developments were reviewed. RESULTS: A single randomized control trial and 4 single-centre studies were included in the review with a total worldwide experience of 241 patients. The deployment was easy and did not add significantly to the primary operation. The mortality and new stroke ranged from 6.3-18.7%. Safe and complete deployment was accomplished in 92-100%. There was no device-related reintervention. There was a significant improvement in malperfusion in over 90% of the cases with varying degrees of remodelling (60-90%) of the downstream aorta. CONCLUSIONS: Open noncovered stent grafts represent a major technical advancement as an adjunct procedure for acute dissection repairs, e.g. hemiarch repair. It has potential for wider use by non-aortic surgeons due to simplicity of technique. Limited safety and efficacy data confirm the device to be safe, feasible and reproducible with potential for wider adoption. However, long-term trial and registry data are required before recommendations for standard use outside of high-volume experienced aortic centres.


Asunto(s)
Disección Aórtica , Implantación de Prótesis Vascular , Stents , Humanos , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/métodos , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/métodos , Procedimientos Endovasculares/efectos adversos , Enfermedad Aguda , Diseño de Prótesis , Aneurisma de la Aorta Torácica/cirugía , Resultado del Tratamiento , Aneurisma de la Aorta/cirugía
4.
Life (Basel) ; 14(3)2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38541709

RESUMEN

BACKGROUND: This study compared perioperative outcomes and long-term survival of saphenous vein grafts (SVGs) versus left internal thoracic artery (LITA) to left anterior descending artery (LAD) in isolated coronary artery bypass graft surgery (CABG). METHODS: In this retrospective, single-centre study, we included patients with primary isolated CABG from January 2001 to July 2022. Baseline demographics were compared between SVG-LAD and LITA-LAD. Univariable and multivariable regressions were performed for predictors of in-hospital death. Propensity score matching was performed for LITA-LAD vs. SVG-LAD. Kaplan-Meier survival curves were generated for comparison of survival. Cox proportional hazards model was used for predictors of survival. RESULTS: A total of 8237 patients (1602 SVG-LAD/6725 LITA-LAD) were included. Median age was 67.9 years (LITA-LAD; 67.1 years vs. SVG-LAD; 71.7 years, p < 0.01). A total of 1270 pairs of SVG-LAD were propensity-matched to LITA-LAD. In matched cohorts, in-hospital mortality (0.8% vs. 1.6%, LITA-LAD and SVG-LAD respectively; p = 0.07), deep sternal wound infection, new cerebrovascular events, renal replacement therapy and hospital stay >30 days were similar. SVG-LAD did not adversely affect in-hospital mortality (OR; 2.03, CI; 0.91, 4.54, p = 0.08). Median long-term survival was similar between the groups (13.7 years vs. 13.1 years for LITA-LAD and SVG-LAD respectively, log rank p < 0.31). SVG-LAD was not a predictor of adverse long-term survival. (HR; 1.06, 95% CI; 0.92, 1.22, p < 0.40). Long-term survival was better with LITA-LAD for LVEF <30% (log rank p < 0.03). CONCLUSIONS: There was no difference in the propensity-matched cohorts for use of SVG vs. LITA to the LAD. Further contemporary long-term studies are needed for substantiation.

5.
Eur J Cardiothorac Surg ; 65(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38331412

RESUMEN

OBJECTIVES: While current data show a clear trend towards the use of bioprosthetic valves during aortic valve replacement (AVR), durability of bioprosthetic valves remains the most important concern. We conducted a 1st systematic review of all available evidence that analysed early and mid-term outcomes after AVR using the Inspiris RESILIA™ bioprosthesis. METHODS: A systematic literature search was performed to identify all relevant studies evaluating early and mid-term outcomes after AVR using the Inspiris RESILIA bioprosthesis and including at least 20 patients with no restriction on the publication date. Subgroup meta-analysis was performed to compare Inspiris RESILIA and PERIMOUNT Magna Ease bioprosthesis and to pool the early postoperative mortality and stroke rates. RESULTS: A total of 416 studies were identified, of which 15 studies met the eligibility criteria. The studies included a total of 3202 patients with an average follow-up of up to 5.3 years. The average age of patients across the studies was 52.2-75.1 years. Isolated AVR was performed in 39.0-86.4% of patients. In-hospital or 30-day postoperative mortality was 0-2.8%. At the mid-term follow-up, freedom from all-cause mortality was up to 85.4%. Among studies with mid-term follow-up, trace/mild paravalvular leak was detected in 0-3.0%, while major paravalvular leak was found only in up to 2.0% of patients. No statistically significant differences in terms of mortality (P = 0.98, odds ratio 1.02, 95% confidence interval 0.36-2.83) and stroke (P = 0.98, odds ratio 1.01, 95% confidence interval 0.38-2.73) between the Inspiris RESILIA bioprosthesis and PERIMOUNT Magna Ease bioprosthesis were observed in the subgroup meta-analysis. CONCLUSIONS: Mid-term data on the safety and haemodynamic performance of the novel aortic bioprosthesis are encouraging. Further comparative studies with other bioprostheses and longer follow-up are still required to endorse durability and safety of the novel bioprosthesis.


Asunto(s)
Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Resultado del Tratamiento , Diseño de Prótesis , Complicaciones Posoperatorias/epidemiología , Anciano
6.
J Cardiovasc Med (Hagerstown) ; 25(4): 334-341, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38407841

RESUMEN

AIMS: The clinical benefits of mitral valve repair over replacement in the setting of mitral infective endocarditis are not clearly established. METHODS: Data of patients who underwent cardiac surgery for infective endocarditis over a 20-year period (2001-2021) at two cardiac centres were reviewed. Among them, 282 patients underwent native mitral valve surgery and were included in the study. Nearest-neighbour propensity-score matching was performed to account for differences in patients' profile between the repair and replacement subgroups. RESULTS: Mitral valve replacement was performed in 186 patients, while in 96 cases patients underwent mitral valve repair. Propensity match analysis provided 89 well matched pairs. Mean age was 60 ±â€Š15 years; 75% of the patients were male. Mitral valve replacement was more commonly performed in patients with involvement of both mitral leaflets, commissure(s) and mitral annulus. Patients with lesion(s) limited to P2 segment formed the majority of the cases undergoing mitral valve repair. There was no difference in terms of microbiological findings. In-hospital mortality was 7% with no difference between the repair and the replacement cohorts. Survival probabilities at 1, 5 and 10 years were 88%, 72% and 68%, respectively after mitral repair, and 88%, 78% and 63%, respectively after mitral replacement (log-rank P  = 0.94). CONCLUSIONS: Mitral valve repair was more commonly performed in patients with isolated single leaflet involvement and provided good early and 10-year outcomes. Patients with annular disruption, lesion(s) on both leaflets and commissure(s) were successfully served on early and mid-term course by mitral valve replacement.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Resultado del Tratamiento , Endocarditis Bacteriana/microbiología , Endocarditis/diagnóstico por imagen , Endocarditis/cirugía , Insuficiencia de la Válvula Mitral/cirugía
9.
J Clin Med ; 12(14)2023 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-37510956

RESUMEN

BACKGROUND: The impact of concomitant coronary artery bypass grafting (CABG) on aortic valve replacement (AVR) in octogenarians is still debated. We analyzed the characteristics and long-term survival of octogenarians undergoing isolated AVR and AVR + CABG. METHODS: All octogenarians who consecutively underwent AVR with or without concomitant CABG at our tertiary cardiac center between 2000 and 2022 were included. Patients with redo, emergent, or any other concomitant procedures were excluded. The primary endpoints were 30-day and long-term survival. The secondary endpoints were early postoperative outcomes and determinants of long-term survival. Univariable and multivariable logistic regression analyses were performed to identify independent predictors of 30-day mortality, and Cox regression analysis was performed for predictors of adverse long-term survival. RESULTS: A total of 1011 patients who underwent AVR (83.0 [81.0-85.0] years, 42.0% males) and 1055 with AVR + CABG (83.0 [81.2-85.4] years, 66.1% males) were included in our study. Survival at 30 days and at 1, 3, and 5 years in the AVR group was 97.9%, 91.5%, 80.5%, and 66.2%, respectively, while in the AVR + CABG group it was 96.2%, 89.6%, 77.7%, and 64.7%, respectively. There was no significant difference in median postoperative survival between the AVR and AVR + CABG groups (7.1 years [IQR: 6.7-7.5] vs. 6.6 years [IQR: 6.3-7.2], respectively, p = 0.21). Significant predictors of adverse long-term survival in the AVR group included age (hazard ratio (HR): 1.09; 95% CI: 1.06-1.12, p < 0.001), previous MI (HR: 2.08; 95% CI: 1.32-3.28, p = 0.002), and chronic kidney disease (HR 2.07; 95% CI: 1.33-3.23, p = 0.001), while in the AVR + CABG group they included age (HR: 1.06; 95% CI: 1.04-1.10, p < 0.001) and diabetes mellitus (HR: 1.48; 95% CI: 1.15-1.89, p = 0.002). Concomitant CABG was not an independent risk factor for adverse long-term survival (HR: 0.89; 95% CI: 0.77-1.02, p = 0.09). CONCLUSIONS: The long-term survival of octogenarians who underwent AVR or AVR + CABG was similar and was not affected by adding concomitant CABG. However, octogenarians who underwent concomitant CABG with AVR had significantly higher in-hospital mortality. Each decision should be discussed within the heart team.

10.
Eur J Cardiothorac Surg ; 63(6)2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-37233116

RESUMEN

OBJECTIVES: While open surgical repair remains the gold standard for thoracoabdominal aortic aneurysm (TAAA) treatment, there is still no consensus regarding perioperative neuromonitoring technique for prevention of spinal cord ischaemia. METHODS: In this systematic review, we aimed to explore the effects and practices of neuromonitoring during the open TAAA repair. A systematic literature search in PubMed, Embase via Ovid, Cochrane library and ClinicalTrialsGov until December 2022 was performed. RESULTS: A total of 535 studies were identified from the literature search, of which 27 studies including a total of 3130 patients met the eligibility criteria. Most studies (21 out of 27, 78%) investigated the feasibility of motor-evoked potentials (MEP), while 15 analysed somatosensory-evoked potentials (SSEP) and 2 studies analysed near-infrared spectroscopy during open TAAA repair. CONCLUSIONS: Current literature suggest that rates of postoperative spinal cord ischaemia can be kept at low levels after open TAAA repair with the adequate precautions and perioperative manoeuvres. Neuromonitoring with MEP provides the surgeon objective criteria to direct selective intercostal reconstruction or other protective anaesthetic and surgical manoeuvres. Simultaneous monitoring of MEP and SSEP is a reliable method that can rapidly detect important findings and direct adequate protective manoeuvres during open TAAA repair.


Asunto(s)
Aneurisma de la Aorta Torácica , Aneurisma de la Aorta Toracoabdominal , Implantación de Prótesis Vascular , Isquemia de la Médula Espinal , Humanos , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico , Resultado del Tratamiento , Potenciales Evocados Motores , Isquemia de la Médula Espinal/etiología , Isquemia de la Médula Espinal/prevención & control , Estudios Retrospectivos
13.
Asian Cardiovasc Thorac Ann ; 30(9): 1001-1009, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36210789

RESUMEN

BACKGROUND: Outcomes for high surgical risk patients who declined transcatheter aortic valve implantation (TAVI) and then reconsidered for conventional aortic valve replacement (rSAVR) for severe calcific aortic stenosis are not well known. METHODS: This single-centre, case-control study (rSAVR vs Conservative group) retrospectively analysed patients for rSAVR (2009-2019). Multivariable logistic regression was used to identify independent predictors of composite of neurological sequelae/renal failure/deep sternal wound infection/re-exploration and death. Survival was compared using Kaplan-Meier curves and log-rank test. A Cox proportional hazards model was used to determine predictors of survival. RESULTS: TAVI was denied in 519/1095 patients, 114(10.4%) had rSAVR (cases) and 405 (37%) were managed conservatively (controls). Mean age for rSAVR was 80 years (IQR: 73.5-85 years). The commonest reason for declining TAVI was prohibitive high risk due to multiple comorbidities. Among rSAVR, hospital mortality was 2.2% and stroke was 4.4%. Median follow-up was conservative; 14.4 months versus rSAVR; 34.8 months. Five-year survival was conservative; 12.6% versus rSAVR; and 59.5% (overall conservative; 38.0% vs. rSAVR; 60.5%, p < 0.001). rSAVR was protective (hazard ratio [HR]: 0.37, 95% confidence interval [CI]: 0.26, 0.51, p < 0.001) and high comorbidities had high hazard (HR: 1.57, 95% CI: 1.19, 2.07, p = 0.001). rSAVR had fewer hospital readmission episodes (Conservative; 13.6/patient-year vs. rSAVR; 6.9/patient-year, p = 0.002). CONCLUSIONS: rSAVR may be considered in high surgical risk elderly patients who have been declined TAVI in centres with low operative mortality. rSAVR may be superior to conservative management in carefully selected patients.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Estudios de Casos y Controles , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
15.
Asian Cardiovasc Thorac Ann ; 30(7): 788-796, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35469437

RESUMEN

BACKGROUND: The aim of this study was to evaluate early- and mid-term results of our actual practice embedding redo aortic valve replacement and transcatheter procedures for aortic bioprosthetic failure. METHODS: Data for aortic valve reinterventions (redo surgical aortic valve replacement, isolated redo aortic valve replacement, and valve-in-valve transcatheter aortic valve implantation, transcatheter valve-in-valve procedure) were collected (2010-2019). Logistic regression analysis was performed to identify predictors favouring the choice of transcatheter against redo surgery. Cox analysis was used to study the association of preoperative variables with survival. Survival probabilities were calculated with Kaplan-Meier analysis and compared using a log-rank test. RESULTS: A total of 125 patients were included (redo surgical aortic valve replacement: 84 patients, valve-in-valve transcatheter aortic valve implantation: 41 patients). Median age was 74 [63-80] years, 58% of the patients were male and the median logistic EuroSCORE was 15 [8-26] %. There was no early mortality. Eighteen patients (redo surgical aortic valve replacement: 15, valve-in-valve transcatheter aortic valve implantation: 3) sustained at least one postoperative complication. At pre-discharge transthoracic echocardiogram, valve-in-valve transcatheter aortic valve implantation had significantly higher trans-prosthetic gradients (mean gradient: valve-in-valve transcatheter aortic valve implantation 18 mmHg vs. redo surgical aortic valve replacement 14 mmHg, p < 0.001). Overall survival probabilities were 94% and 73% at 1 year and 5 years, respectively. Previous coronary artery bypass surgery operation and age were independently associated with lower survival probabilities during the follow-up. CONCLUSIONS: Redo surgical aortic valve replacement and valve-in-valve transcatheter aortic valve implantation are both safe and effective for aortic bioprosthetic failure. Further valve-in-valve data are needed to determine the haemodynamic performance of transcatheter prostheses and its impact on long-term outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Falla de Prótesis , Reoperación , Factores de Riesgo , Resultado del Tratamiento
16.
Eur J Cardiothorac Surg ; 62(4)2022 09 02.
Artículo en Inglés | MEDLINE | ID: mdl-35394533
17.
Artículo en Inglés | MEDLINE | ID: mdl-35348698

RESUMEN

OBJECTIVES: Several concerns have been recently raised regarding the durability of Trifecta prostheses. Different mechanisms of early failure were reported. Our aim was to study in a large population the modes of failure of Trifecta valves. METHODS: We conducted a retrospective analysis of patients who underwent surgical aortic valve replacement with a Trifecta prosthesis during the period 2010-2018. Details regarding the mode of failure and haemodynamic dysfunction were collected for patients who underwent reintervention for structural valve failure. The Kaplan-Meier method was used to calculate survival. Competing risk analysis was performed to calculate the cumulative risk of reintervention for structural valve failure. RESULTS: The overall population comprises 1228 patients (1084 TF model and 144 TFGT model). Forty-four patients-mean patients' age at the time of the first implant 69 (standard deviation: 12) years and 61% female-underwent reintervention for structural valve failure after a median time of 63 [44-74] months. The cumulative incidence of reintervention for structural valve failure was 0.16% (SE 0.11%), 1.77% (SE 0.38%) and 5.11% (SE 0.98%) at 1, 5 and 9 years, respectively. In 24/44 patients (55%), a leaflet tear with dehiscence at the commissure level was found intraoperatively or described by imaging assessment. The cumulative incidence of reintervention for failure due to leaflet(s) tear was 0.16% (SE 0.11%), 1.08% (SE 0.29%) and 3.03% (SE 0.88%) at 1, 5 and 9 years, respectively. CONCLUSIONS: Leaflet(s) tear with dehiscence along the stent post was the main mode of early failure, up to 5 years, after Trifecta valves' implantation.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Hemodinámica , Humanos , Masculino , Diseño de Prótesis , Falla de Prótesis , Estudios Retrospectivos
18.
J Card Surg ; 37(5): 1263-1271, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35179249

RESUMEN

BACKGROUND: The aim of this study was to analyze perioperative results and long-term survival of re-sternotomy for surgical aortic valve replacement (SAVR) in octogenarians in age of transcatheter therapies. METHODS: This is a retrospective, single-center study (April 2000 to December 2019). Perioperative data were compared for re-sternotomy with isolated SAVR (Isolated redoSAVR) and re-sternotomy with SAVR and concomitant cardiac procedure (Associated redoSAVR). Regression analyses were performed to identify predictors of in-patient mortality. Hazard ratios and Kaplan-Meier survival curves were compared for groups. RESULTS: There were 163 patients (Isolated redoSAVR; 69, Associated redoSAVR; 94). Emergency/salvage cases were excluded. The median age was 83 (81-85) years and the median logEuroSCORE was 19.2 (13.0-26.7)%. The follow-up was 4.2 ± 3.5 years. Inpatient mortality was 4.9% (1.4% vs. 7.4% for Isolated redoSAVR and Associated redoSAVR respectively, p = .08). TIA/stroke rate was 8% (9% vs. 7% for Isolated redoSAVR and Associated redoSAVR, respectively, p = .78). COPD was a predictor of inpatient mortality (odds ratio: 8.86; 95% confidence interval: 1.19-66.11, p = .03). Survival was 88.7%, 86.4%, 70.1%, 49.5%, and 26.3% at 1, 2, 5, 7, and 10 years. There was no survival difference between Isolated redoSAVR and Associated redoSAVR (log rank p = .36, Wilcoxon p = .84). Significant adverse predictors of long-term survival were COPD, postoperative TIA/stroke, and length of stay. Survival was lower than age and gender-matched first-time SAVR and general population of the United Kingdom. CONCLUSION: RedoSAVR in octogenarians is associated with significant morbidity and mortality. Shared decision-making should consider emerging transcatheter therapies as a valuable option in selected patients.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Octogenarios , Estudios Retrospectivos , Factores de Riesgo , Esternotomía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
19.
Asian Cardiovasc Thorac Ann ; 30(6): 688-695, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35179395

RESUMEN

OBJECTIVE: The aim was to evaluate early and long-term outcomes of re-sternotomy for aortic valve replacement (AVR) with previous patent coronary artery grafts. METHODS: Data for re-sternotomy for AVRs (group 1 isolated AVR, group 2 AVR with concomitant procedure) were collected (2000-2019). Logistic regression analysis was performed to identify predictors of in-hospital mortality and postoperative composite outcome (in-hospital death, transient ischemic attack/stroke, renal failure requiring new hemofiltration, deep sternal wound infection, re-exploration for bleeding/tamponade and length of stay >30 days). Survival curves were compared using log-rank test Cox proportion hazards model was used for predictors of long-term survival. RESULTS: Total 178 patients were included (groups 1-90 patients, group 2-88 patients). Mean age was 75 ± 4 years and mean log EuroSCORE was 17 ± 12% (15 ± 8% - group 1 vs. 19 ± 14% - group 2, p = 0.06). Mean follow-up was 6.3 ± 4.4 years. Cardiovascular injury occurred in 12%. Left internal mammary artery was most commonly injured. In-hospital mortality was 7.8% (5% - group 1 vs. 10.2% - group 2, p = 0.247). NYHA class III-IV, perioperative intra-aortic balloon pump and cardiovascular injury were independent predictors of in-hospital mortality (hazard ratio: 13.33, 95% confidence interval: 2.04-83.33, p = 0.007). Survival was significantly worse with cardiovascular injury at re-sternotomy up to 5 years (46% vs. 67%, p = 0.025) and postoperative complications (p = 0.023). Survival was significantly lower than age-matched first-time AVR and UK population. CONCLUSIONS: Long-term survival is significantly impaired by cardiovascular injury and perioperative complications of re-sternotomy.


Asunto(s)
Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Vasos Coronarios/cirugía , Mortalidad Hospitalaria , Humanos , Complicaciones Posoperatorias , Estudios Retrospectivos , Esternotomía/efectos adversos , Resultado del Tratamiento
20.
Ann Thorac Surg ; 114(4): e299-e301, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35063418

RESUMEN

Intraoperative open aortoscopy is a new emerging technique in hybrid aortic arch surgery using hybrid open stent grafts for frozen elephant trunk operation. It is performed on a detumescent open aortic arch during the period of deep hypothermic circulatory arrest. It aids in operative planning and choice of open stent graft and confirms proper deployment and distal seal prior to resumption of circulation.


Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Implantación de Prótesis Vascular/métodos , Humanos , Stents , Tórax , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA