Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Anal Chim Acta ; 1307: 342560, 2024 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-38719398

RESUMEN

BACKGROUND: Point-of-care (POC) nucleic acid amplification tests (NAAT) can significantly expand testing coverage, which is critical for infectious disease diagnostics and monitoring. The development of various isothermal amplification techniques greatly simplifies NAATs, but the cumbersome nucleic acid extraction step remains a bottleneck for the POC. Alternatively, extraction-free amplification, where crude samples are directly added into the assay, substantially simplifies the workflow. However, sample dilution is often needed in extraction-free amplification to reduce assay inhibition from sample matrices. Since NAATs are typically run at small volumes around 20 µL, the input sample quantity is therefore limited, resulting in an inevitable sensitivity loss. RESULTS: Here we explore the potential to perform isothermal amplification in larger reaction volumes to accommodate larger sample quantities, thereby improving sensitivity in extraction-free amplification. We demonstrated the approach by developing large-volume reverse transcription loop-mediated isothermal amplification (RT-LAMP) for HIV RNA detection from fingerstick plasma. We found that LAMP at reaction volumes up to 1 mL maintained the same performance. We then identified plasma dilution conditions needed to maintain the limit of detection in RT-LAMP. Subsequently, using inactivated HIV virus, we showed the successful detection of 24 HIV RNA copies in a 500 µL RT-LAMP reaction in the presence of 20 µL plasma (fingerstick volumes), translating to a viral load of 1200 copies per mL. To reduce the increased reagent cost with expanded reaction volumes, we further identified lower-cost reagents with maintained assay performance. Moreover, we showed that large-volume LAMP, compared to 20 µL reactions, could tolerate higher concentrations of various inhibitors in the sample, such as albumin and GuSCN. SIGNIFICANCE AND NOVELTY: NAATs are conventionally conducted at small reaction volumes. Here we demonstrated that LAMP can be run at large reaction volumes (over 100 µL) with maintained assay performance, allowing sample inhibition to be mitigated while accommodating larger sample quantities. The same strategy of expanding reaction volumes could be applied to other isothermal amplification methods and various POC applications, to streamline test workflows and/or improve assay sensitivity.


Asunto(s)
Técnicas de Amplificación de Ácido Nucleico , ARN Viral , Técnicas de Amplificación de Ácido Nucleico/métodos , Humanos , ARN Viral/sangre , Infecciones por VIH/sangre , Infecciones por VIH/diagnóstico , Infecciones por VIH/virología , VIH-1/genética , VIH-1/aislamiento & purificación , Límite de Detección , Técnicas de Diagnóstico Molecular
2.
medRxiv ; 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38633802

RESUMEN

Pathogens encapsulate or encode their own suite of enzymes to facilitate replication in the host. The pathogen-derived enzymes possess specialized activities that are essential for pathogen replication and have naturally been candidates for drug targets. Phenotypic assays detecting the activities of pathogen-derived enzymes and characterizing their inhibition under drugs offer an opportunity for pathogen detection, drug resistance testing for individual patients, and as a research tool for new drug development. Here, we used HIV as an example to develop assays targeting the reverse transcriptase (RT) enzyme encapsulated in HIV for sensitive detection and phenotypic characterization, with the potential for point-of-care (POC) applications. Specifically, we targeted the complementary (cDNA) generation activity of the HIV RT enzyme by adding engineered RNA as substrates for HIV RT enzyme to generate cDNA products, followed by cDNA amplification and detection facilitated by loop-mediated isothermal amplification (LAMP) or CRISPR-Cas systems. To guide the assay design, we first used qPCR to characterize the cDNA generation activity of HIV RT enzyme. In the LAMP-mediated Product-Amplified RT activity assay (LamPART), the cDNA generation and LAMP amplification were combined into one pot with novel assay designs. When coupled with direct immunocapture of HIV RT enzyme for sample preparation and endpoint lateral flow assays for detection, LamPART detected as few as 20 copies of HIV RT enzyme spiked into 25µL plasma (fingerstick volume), equivalent to a single virion. In the Cas-mediated Product-Amplified RT activity assay (CasPART), we tailored the substrate design to achieve a LoD of 2e4 copies (1.67fM) of HIV RT enzyme. Furthermore, with its phenotypic characterization capability, CasPART was used to characterize the inhibition of HIV RT enzyme under antiretroviral drugs and differentiate between wild-type and mutant HIV RT enzyme for potential phenotypic drug resistance testing. Moreover, the CasPART assay can be readily adapted to target the activity of other pathogen-derived enzymes. As a proof-of-concept, we successfully adapted CasPART to detect HIV integrase with a sensitivity of 83nM. We anticipate the developed approach of detecting enzyme activity with product amplification has the potential for a wide range of pathogen detection and phenotypic characterization.

3.
Anal Chim Acta ; 1277: 341674, 2023 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-37604625

RESUMEN

Lateral flow assays (LFAs) provide a simple and quick option for diagnosis and are widely adopted for point-of-care or at-home tests. However, their sensitivity is often limited. Most LFAs only allow 50 µL samples while various sample types such as saliva could be collected in much larger volumes. Adapting LFAs to accommodate larger sample volumes can improve assay sensitivity by increasing the number of target analytes available for detection. Here, a simple agglutination system comprising biotinylated antibody (Ab) and streptavidin (SA) is presented. The Ab and SA agglutinate into large aggregates due to multiple biotins per Ab and multiple biotin binding sites per SA. Dynamic light scattering (DLS) measurements showed that the agglutinated aggregate could reach a diameter of over 0.5 µm and over 1.5 µm using poly-SA. Through both experiments and Monte Carlo modeling, we found that high valency and equivalent concentrations of the two aggregating components were critical for successful agglutination. The simple agglutination system enables antigen capture from large sample volumes with biotinylated Ab and a swift transition into aggregates that can be collected via filtration. Combining the agglutination system with conventional immunoassays, an agglutination assay is proposed that enables antigen detection from large sample volumes using an in-house 3D-printed device. As a proof-of-concept, we developed an agglutination assay targeting SARS-CoV-2 nucleocapsid antigen for COVID-19 diagnosis from saliva. The assay showed a 10-fold sensitivity enhancement when increasing sample volume from 50 µL to 2 mL, with a final limit of detection (LoD) of 10 pg mL-1 (∼250 fM). The assay was further validated in negative saliva spiked with gamma-irradiated SARS-CoV-2 and showed an LoD of 250 genome copies per µL. The proposed agglutination assay can be easily developed from existing LFAs to facilitate the processing of large sample volumes for improved sensitivity.


Asunto(s)
Prueba de COVID-19 , COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2 , Anticuerpos , Biotina , Aglutinación
4.
Artículo en Inglés | MEDLINE | ID: mdl-36061038

RESUMEN

Background: Digital adherence technologies hold promise to improve patient-centered tuberculosis (TB) monitoring, yet few studies have incorporated direct adherence monitoring or assessed patients' experiences with these technologies. We explored acceptability, feasibility, and refinement needs of the TB Treatment Support Tools (TB-TSTs) intervention linking a mobile app, a urine drug metabolite test, and interactive communication with a treatment supporter. Methods: This pilot study was a parallel-designed single-center randomized controlled trial with exit interviews. Newly diagnosed TB patients were randomized 1:1 using a treatment allocation button in the REDCap software preloaded with a random allocation sequence to usual care or usual care plus the TB-TSTs intervention from a respiratory medicine hospital in the province of Buenos Aires, Argentina and followed for 6-months. Due to the nature of the intervention, blinding to the group allocation could not be achieved for the recruiter or patients. The treatment outcome data extractor was blinded to the group allocation of the participants. Intervention participants used the app to report self-administering medication, potential side effects, submit photos of the urine test, and interact with a treatment supporter. Outcomes were feasibility, acceptability, and treatment outcomes. Findings: Forty-two patients were enrolled and evenly assigned to each group. Intervention participants submitted 147·2±58 (mean, SD) medication self-administration and 144·5±55 side effect reports out of 180 and 47.5±38·4 photos of the urine test out of 77. Treatment success for usual care was 81% [17/21] and 95% [20/21] for the TB-TSTs intervention. Thirty-three themes were identified within the main categories of motivation, what worked, issues experienced, and recommendations. Participants (n=12) rated it as 'easy to use' (4.57/5), 'would highly recommend to others' (4·43/5) and reported that access to the treatment support was a critical component. Recommendations included adding an alarm, appointment reminders, and off-line functionality. Interpretation: Findings suggest that the TB-TSTs intervention was feasible and acceptable and further refinement and testing is warranted. Funding: National Institute of Health K23NR017210.

5.
Microbiol Spectr ; 10(4): e0158321, 2022 08 31.
Artículo en Inglés | MEDLINE | ID: mdl-35708340

RESUMEN

The increasing prevalence of variant lineages during the COVID-19 pandemic has the potential to disrupt molecular diagnostics due to mismatches between primers and variant templates. Point-of-care molecular diagnostics, which often lack the complete functionality of their high-throughput laboratory counterparts, are particularly susceptible to this type of disruption, which can result in false-negative results. To address this challenge, we have developed a robust Loop Mediated Isothermal Amplification assay with single tube multiplexed multitarget redundancy and an internal amplification control. A convenient and cost-effective target-specific fluorescence detection system allows amplifications to be grouped by signal using adaptable probes for pooled reporting of SARS-CoV-2 target amplifications or differentiation of the Internal Amplification Control. Over the course of the pandemic, primer coverage of viral lineages by the three redundant sub-assays has varied from assay to assay as they have diverged from the Wuhan-Hu-1 isolate sequence, but aggregate coverage has remained high for all variant sequences analyzed, with a minimum of 97.4% (Variant of Interest: Eta). In three instances (Delta, Gamma, Eta), a high-frequency mismatch with one of the three sub-assays was observed, but overall coverage remained high due to multitarget redundancy. When challenged with extracted human samples the multiplex assay showed 87% or better sensitivity (of 30 positive samples), with 100% sensitivity for samples containing greater than 30 copies of viral RNA per reaction (of 21 positive samples), and 100% specificity (of 60 negative samples). These results are further evidence that conventional laboratory methodologies can be leveraged at the point of care for robust performance and diagnostic stability over time. IMPORTANCE The COVID-19 pandemic has had tremendous impact, and the ability to perform molecular diagnostics in resource limited settings has emerged as a key resource for mitigating spread of the disease. One challenge in COVID-19 diagnosis, as well as other viruses, is ongoing mutation that can allow viruses to evade detection by diagnostic tests. We developed a test that detects multiple parts of the virus genome in a single test to reduce the chance of missing a virus due to mutation, and it is designed to be simpler and faster than typical laboratory tests while maintaining high sensitivity. This capability is enabled by a novel fluorescent probe technology that works with a simple constant temperature reaction condition.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Prueba de COVID-19 , Técnicas de Laboratorio Clínico/métodos , Colorantes Fluorescentes , Humanos , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificación de Ácido Nucleico , Pandemias , SARS-CoV-2/genética , Sensibilidad y Especificidad
6.
Analyst ; 147(14): 3315-3327, 2022 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-35762367

RESUMEN

The COVID-19 pandemic interrupted routine care for individuals living with HIV, putting them at risk of virologic failure and HIV-associated illness. Often this population is at high risk for exposure to SARS-CoV-2 infection, and once infected, for severe disease. Therefore, close monitoring of HIV plasma viral load (VL) and screening for SARS-CoV-2 infection are needed. We developed a non-proprietary method to isolate RNA from plasma, nasal secretions (NS), or both. The extracted RNA is then submitted to RT-qPCR to estimate the VL and classify HIV/SARS-CoV-2 status (i.e., HIV virologic failure or suppressed; SARS-CoV-2 as positive, presumptive positive, negative, or indeterminate). In contrived samples, the in-house RNA extraction workflow achieved a detection limit of 200-copies per mL for HIV RNA in plasma and 100-copies per mL for SARS-CoV-2 RNA in NS. Similar detection limits were observed for HIV and SARS-CoV-2 in pooled plasma/NS contrived samples. When comparing in-house with standard extraction methods, we found high agreement (>0.91) between input and measured RNA copies for HIV LTR in contrived plasma; SARS-CoV-2 N1/N2 in contrived NS; and LTR, N1, and N2 in pooled plasma/NS samples. We further evaluated this workflow on 133 clinical specimens: 40 plasma specimens (30 HIV-positive), 67 NS specimens (31 SARS-CoV-2-positive), and 26 combined plasma/NS specimens (26 HIV-positive with 10 SARS-CoV-2-positive), and compared the results obtained using the in-house RNA extraction to those using a commercial kit (standard extraction method). The in-house extraction and standard extraction of clinical specimens were positively correlated: plasma HIV VL (R2 of 0.81) and NS SARS-CoV-2 VL (R2 of 0.95 and 0.99 for N1 and N2 genes, respectively); and pooled plasma/NS HIV VL (R2 of 0.71) and SARS-CoV-2 VL (R2 of 1 both for N1 and N2 genes). Our low-cost molecular test workflow ($1.85 per pooled sample extraction) for HIV RNA and SARS-CoV-2 RNA could serve as an alternative to current standard assays ($12 per pooled sample extraction) for laboratories in low-resource settings.


Asunto(s)
COVID-19 , Infecciones por VIH , COVID-19/diagnóstico , Infecciones por VIH/diagnóstico , Humanos , Pandemias , ARN Viral/análisis , SARS-CoV-2/genética , Sensibilidad y Especificidad , Carga Viral/métodos , Flujo de Trabajo
7.
Anal Chem ; 94(20): 7278-7285, 2022 05 24.
Artículo en Inglés | MEDLINE | ID: mdl-35532905

RESUMEN

The COVID-19 pandemic is among the greatest health and socioeconomic crises in recent history. Although COVID-19 vaccines are being distributed, there remains a need for rapid testing to limit viral spread from infected individuals. We previously identified the SARS-CoV-2 spike protein N-terminal domain (NTD) binding DNA aptamer 1 (SNAP1) for detection of SARS-CoV-2 virus by aptamer-antibody sandwich enzyme-linked immunoassay (ELISA) and lateral flow assay (LFA). In this work, we identify a new aptamer that also binds at the NTD, named SARS-CoV-2 spike protein NTD-binding DNA aptamer 4 (SNAP4). SNAP4 binds with high affinity (<30 nM) for the SARS-CoV-2 spike protein, a 2-fold improvement over SNAP1. Furthermore, we utilized both SNAP1 and SNAP4 in an aptamer sandwich LFA (AptaFlow), which detected SARS-CoV-2 UV-inactivated virus at concentrations as low as 106 copies/mL. AptaFlow costs <$1 per test to produce, provides results in <1 h, and detects SARS-CoV-2 at concentrations that indicate higher viral loads and a high probability of contagious transmission. AptaFlow is a potential approach for a low-cost, convenient antigen test to aid the control of the COVID-19 pandemic.


Asunto(s)
Aptámeros de Nucleótidos , COVID-19 , Anticuerpos Antivirales , Aptámeros de Nucleótidos/química , COVID-19/diagnóstico , Vacunas contra la COVID-19 , Humanos , Pandemias , SARS-CoV-2 , Glicoproteína de la Espiga del Coronavirus
9.
PLOS Glob Public Health ; 2(2): e0000185, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36962187

RESUMEN

Usability is an overlooked aspect of implementing lab-based assays, particularly novel assays in low-resource-settings. Esoteric instructions can lead to irreproducible test results and patient harm. To address these issues, we developed a software application based on "Aquarium", a laboratory-operating system run on a computer tablet that provides step-by-step digital interactive instructions, protocol management, and sample tracking. Aquarium was paired with a near point-of-care HIV drug resistance test, "OLA-Simple", that detects mutations associated with virologic failure. In this observational study we evaluated the performance of Aquarium in guiding untrained users through the multi-step laboratory protocol with little supervision. To evaluate the training by Aquarium software we conducted a feasibility study in a laboratory at Coptic Hope Center in Nairobi, Kenya. Twelve volunteers who were unfamiliar with the kit performed the test on blinded samples (2 blood specimens; 5 codons/sample). Steps guided by Aquarium included: CD4+ T-Cell separation, PCR, ligation, detection, and interpretation of test results. Participants filled out a short survey regarding their demographics and experience with the software and kit. None of the laboratory technicians had prior experience performing CD4+ separation and 7/12 had no experience performing laboratory-based molecular assays. 12/12 isolated CD4+ T cells from whole blood with yields comparable to isolations performed by trained personnel. The OLA-Simple workflow was completed by all, with genotyping results interpreted correctly by unaided-eye in 108/120 (90%) and by software in 116/120 (97%) of codons analyzed. In the surveys, participants favorably assessed the use of software guidance. The Aquarium digital instructions enabled first-time users in Kenya to complete the OLA-simple kit workflow with minimal training. Aquarium could increase the accessibility of laboratory assays in low-resource-settings and potentially standardize implementation of clinical laboratory tests.

10.
J Clin Microbiol ; 60(5): e0188421, 2022 05 18.
Artículo en Inglés | MEDLINE | ID: mdl-34911365

RESUMEN

Home testing for infectious disease has come to the forefront during the COVID-19 pandemic. There is now considerable commercial interest in developing complete home tests for a variety of viral and bacterial pathogens. However, the regulatory science around home infectious disease test approval and procedures that test manufacturers and laboratory professionals will need to follow have not yet been formalized by the U.S. Food and Drug Administration (FDA), with the exception of Emergency Use Authorization (EUA) guidance for COVID-19 tests. We describe the state of home-based testing for influenza with a focus on sample-to-result home tests, discuss the various regulatory pathways by which these products can reach populations, and provide recommendations for study designs, patient samples, and other important features necessary to gain market access. These recommendations have potential application for home use tests being developed for other viral respiratory infections, such as COVID-19, as guidance moves from EUA designation into 510(k) requirements.


Asunto(s)
COVID-19 , Gripe Humana , COVID-19/diagnóstico , Humanos , Gripe Humana/diagnóstico , Laboratorios , Pandemias , SARS-CoV-2
11.
Anal Chem ; 94(2): 1011-1021, 2022 01 18.
Artículo en Inglés | MEDLINE | ID: mdl-34920665

RESUMEN

Point-of-care diagnostics often use isothermal nucleic acid amplification for qualitative detection of pathogens in low-resource healthcare settings but lack sufficient precision for quantitative applications such as HIV viral load monitoring. Although viral load (VL) monitoring is an essential component of HIV treatment, commercially available tests rely on relatively high-resource chemistries like real-time polymerase chain reaction and are thus used on an infrequent basis for millions of people living with HIV in low-income countries. To address the constraints of low-resource settings on nucleic acid quantification, we describe a recombinase polymerase amplification and lateral flow detection approach that quantifies HIV-1 DNA or RNA by comparison to a competitive internal amplification control (IAC) of a known copy number, which may be set to any useful threshold (in our case, a clinically relevant threshold for HIV treatment failure). The IAC is designed to amplify alongside the HIV target with a similar efficiency, allowing for normalization of the assay to variation or inhibition and enabling an endpoint readout that is compatible with commercially available kits for nucleic acid lateral flow detection and interpretable with minimal instrumentation or by the naked eye. We find that this approach can reliably differentiate ≤600 or ≥1400 copies of HIV DNA from a 1000-copy threshold when lateral flow strips are imaged with a conventional office scanner and analyzed with free densitometry software. We further demonstrate a user-friendly adaptation of this analysis to process cell phone photographs with an automated script. Alternatively, we show via a survey that 21 minimally trained volunteers could reliably resolve ≥10-fold (log10) differences of HIV DNA or RNA by naked eye interpretation of lateral flow results. This amplification and detection workflow requires minimal instrumentation, takes just 30 min to complete, and when combined with a suitable sample preparation method, may enable HIV VL testing while the patient waits or a self-test, which has the potential to improve care. This approach may be adapted for other applications that require quantitative analysis of a nucleic acid target in low-resource settings.


Asunto(s)
Infecciones por VIH , Técnicas de Amplificación de Ácido Nucleico , Infecciones por VIH/diagnóstico , Humanos , Técnicas de Amplificación de Ácido Nucleico/métodos , Pruebas en el Punto de Atención , ARN Viral/genética , Recombinasas , Carga Viral
12.
Sci Adv ; 7(51): eabj1281, 2021 Dec 17.
Artículo en Inglés | MEDLINE | ID: mdl-34910507

RESUMEN

RNA amplification tests sensitively detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection, but their complexity and cost are prohibitive for expanding coronavirus disease 2019 (COVID-19) testing. We developed "Harmony COVID-19," a point-of-care test using inexpensive consumables, ready-to-use reagents, and a simple device. Our ready-to-use, multiplexed reverse transcription, loop-mediated isothermal amplification (RT-LAMP) can detect down to 0.38 SARS-CoV-2 RNA copies/µl and can report in 17 min for high­viral load samples (5000 copies/µl). Harmony detected 97 or 83% of contrived samples with ≥0.5 viral particles/µl in nasal matrix or saliva, respectively. Evaluation in clinical nasal specimens (n = 101) showed 100% detection of RNA extracted from specimens with ≥0.5 SARS-CoV-2 RNA copies/µl, with 100% specificity in specimens positive for other respiratory pathogens. Extraction-free analysis (n = 29) had 95% success in specimens with ≥1 RNA copies/µl. Usability testing performed first time by health care workers showed 95% accuracy.

13.
AIDS Res Hum Retroviruses ; 37(12): 930-935, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34714103

RESUMEN

The nucleoside reverse transcriptase inhibitor abacavir (ABC) is used commonly to treat young children with HIV infection and is a component of the fixed-dose-combination Triumeq®. ABC can trigger a severe hypersensitivity reaction in people who are homozygous or heterozygous for HLA-B*57:01. Testing for HLA-B*57:01 before ABC initiation is standard-of-care in high-resource settings, but current tests are costly or difficult to access in resource-limited settings. To address these gaps, we developed an inexpensive simple-to-use rapid assay to detect HLA-B*57:01. We designed and optimized a multiplexed polymerase chain reaction (PCR) to amplify HLA-B*57 subtypes and the human beta-globin gene; employed probes and ligation to specifically tag the HLA-B*57:01 allele with biotin. Tagged-ligated products were detected by immunocapture in an enzyme-linked immunosorbent assay plate or lateral flow strip. Cell lines with known HLA genotypes were used to optimize the assay. The optimized assay was then compared with genotypes of clinical specimens (n = 60) determined by sequencing, with specimens enriched for individuals with HLA-B*57:01. The optimized assay utilizes 40-min 35-cycle multiplex PCR for B*57 and beta-globin; 20-min ligation reaction; and 15-min detection. Evaluation of the HLA-B*57:01 oligonucleotide ligation assay using clinical specimens had a sensitivity of 100% (n = 27/27 typed as B*57:01) and specificity of 100% (n = 33/33 typed as non-B*57:01) by visual interpretation of lateral flow strips. The cost is US$5.96/specimen. This rapid and economical assay accurately detects HLA-B*57:01 in clinical specimens. Use of this assay could expand access to HLA-B*57:01 genotyping and facilitate safe same-day initiation of ABC-based treatment.


Asunto(s)
Fármacos Anti-VIH , Infecciones por VIH , Alelos , Fármacos Anti-VIH/efectos adversos , Preescolar , Didesoxinucleósidos/efectos adversos , Genotipo , Infecciones por VIH/tratamiento farmacológico , Infecciones por VIH/genética , Antígenos HLA-B/genética , Humanos , Sistemas de Atención de Punto
14.
Int J Infect Dis ; 112: 330-337, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34562627

RESUMEN

BACKGROUND: Urine cell-free DNA (cfDNA) is an attractive target for diagnosing pulmonary Mycobacterium tuberculosis (MTB) infection, but has not been thoroughly characterized as a biomarker. METHODS: This study was performed to investigate the size and composition of urine cfDNA from tuberculosis (TB) patients with minimal bias using next-generation sequencing (NGS). A combination of DNA extraction and single-stranded sequence library preparation methods demonstrated to recover short, highly degraded cfDNA fragments was employed. Urine cfDNA from 10 HIV-positive patients with pulmonary TB and two MTB-negative controls was examined. RESULTS: MTB-derived cfDNA was identifiable by NGS from all MTB-positive patients and was absent from negative controls. MTB cfDNA was significantly shorter than human cfDNA, with median fragment lengths of ≤19-52 bp and 42-92 bp, respectively. MTB cfDNA abundance increased exponentially with decreased fragment length, having a peak fragment length of ≤19 bp in most samples. In addition, we identified a larger fraction of short human genomic cfDNA, ranging from 29 to 53 bp, than previously reported. Urine cfDNA fragments spanned the MTB genome with relative uniformity, but nucleic acids derived from multicopy elements were proportionately over-represented. CONCLUSIONS: TB urine cfDNA is a potentially powerful biomarker but is highly fragmented, necessitating special procedures to maximize its recovery and detection.


Asunto(s)
Ácidos Nucleicos Libres de Células , Mycobacterium tuberculosis , Tuberculosis Pulmonar/diagnóstico , Biomarcadores/orina , Ácidos Nucleicos Libres de Células/orina , ADN Bacteriano/orina , Secuenciación de Nucleótidos de Alto Rendimiento , Humanos , Mycobacterium tuberculosis/genética
15.
medRxiv ; 2021 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-34462755

RESUMEN

The increasing prevalence of variant lineages during the COVID-19 pandemic has the potential to disrupt molecular diagnostics due to mismatches between primers and variant templates. Point-of-care molecular diagnostics, which often lack the complete functionality of their high throughput laboratory counterparts, are particularly susceptible to this type of disruption, which can result in false negative results. To address this challenge, we have developed a robust Loop Mediated Isothermal Amplification assay with single tube multiplexed multi-target redundancy and an internal amplification control. A convenient and cost-effective target specific fluorescence detection system allows amplifications to be grouped by signal using adaptable probes for pooled reporting of SARS-COV-2 target amplifications or differentiation of the Internal Amplification Control. Over the course of the pandemic, primer coverage of viral lineages by the three redundant sub-assays has varied from assay to assay as they have diverged from the Wuhan-Hu-1 isolate sequence, but aggregate coverage has remained high for all variant sequences analyzed, with a minimum of 97.4% (Variant of Interest: Eta). In three instances (Delta, Gamma, Eta), a high frequency mismatch with one of the three sub-assays was observed, but overall coverage remained high due to multi-target redundancy. When challenged with extracted human samples the multiplexed assay showed 100% sensitivity for samples containing greater than 30 copies of viral RNA per reaction, and 100% specificity. These results are further evidence that conventional laboratory methodologies can be leveraged at the point-of-care for robust performance and diagnostic stability over time.

16.
medRxiv ; 2021 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-34462759

RESUMEN

BACKGROUND: COVID-19 pandemic interrupted routine care for individuals living with HIV, putting them at risk of becoming virologically unsuppressed and ill. Often they are at high risk for exposure to SARS-CoV-2 infection and severe disease once infected. For this population, it is urgent to closely monitor HIV plasma viral load ( VL ) and screen for SARS-COV-2 infection. METHOD: We have developed a non-proprietary method to isolate RNA from plasma, nasal secretions ( NS ), or both. HIV, SARS-CoV-2, and human RP targets in extracted RNA are then RT-qPCR to estimate the VL and classify HIV/SARS-CoV-2 status ( i . e ., HIV as VL failure or suppressed; SARS-CoV-2 as positive, presumptive positive, negative, or indeterminate). We evaluated this workflow on 133 clinical specimens: 40 plasma specimens (30 HIV-seropositive), 67 NS specimens (31 SARS-CoV-2-positive), and 26 pooled plasma/NS specimens (26 HIV-positive with 10 SARS-CoV-2-positive), and compared the results obtained using the in-house extraction to those using a commercial extraction kit. RESULTS: In-house extraction had a detection limit of 200-copies/mL for HIV and 100-copies/mL for SARS-CoV-2. In-house and commercial methods yielded positively correlated HIV VL (R 2 : 0.98 for contrived samples; 0.81 for seropositive plasma). SARS-CoV-2 detection had 100% concordant classifications in contrived samples, and in clinical NS extracted by in-house method, excluding indeterminate results, was 95% concordant (25 positives, 6 presumptive positives, and 31 negatives) to those using the commercial method. Analysis of pooled plasma/NS showed R 2 of 0.91 (contrived samples) and 0.71 (clinical specimens) for HIV VL correlations obtained by both extraction methods, while SARS-CoV-2 detection showed 100% concordance in contrived and clinical specimens. INTERPRETATION: Our low-cost workflow for molecular testing of HIV and SARS-CoV-2 could serve as an alternative to current standard assays for laboratories in low-resource settings.

17.
Cureus ; 13(5): e15324, 2021 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-34221772

RESUMEN

Measurement of intracranial pressure (ICP) during cerebrospinal fluid (CSF) drainage with an external ventricular drain (EVD) typically requires stopping the flow during measurement. However, there may be benefits to simultaneous ICP measurement and CSF drainage. Several studies have evaluated whether accurate ICP measurements can be obtained while the EVD is open. They report differing outcomes when it comes to error, and hypothesize several sources of error. This study presents an investigation into the fluidic sources of error for ICP measurement with concurrent drainage in an EVD. Our experiments and analytical model both show that the error in pressure measurement increases linearly with flow rate and is not clinically significant, regardless of drip chamber height. At physiologically relevant flow rates (40 mL/hr) and ICP set points (13.6 - 31.3 cmH2O or 10 - 23 mmHg), our model predicts an underestimation of 0.767 cmH2O (0.56 mmHg) with no observed data point showing error greater than 1.09 cmH2O (0.8 mmHg) in our experiment. We extrapolate our model to predict a realistic worst-case clinical scenario where we expect to see a mean maximum error of 1.06 cmH2O (0.78 mmHg) arising from fluidic effects within the drainage system for the most resistive catheter. Compared to other sources of error in current ICP monitoring, error in pressure measurement due to drainage flow is small and does not prohibit clinical use. However, other effects such as ventricular collapse or catheter obstruction could affect ICP measurement under continuous drainage and are not investigated in this study.

18.
bioRxiv ; 2021 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-34268509

RESUMEN

Escape variants of SARS-CoV-2 are threatening to prolong the COVID-19 pandemic. To address this challenge, we developed multivalent protein-based minibinders as potential prophylactic and therapeutic agents. Homotrimers of single minibinders and fusions of three distinct minibinders were designed to geometrically match the SARS-CoV-2 spike (S) trimer architecture and were optimized by cell-free expression and found to exhibit virtually no measurable dissociation upon binding. Cryo-electron microscopy (cryoEM) showed that these trivalent minibinders engage all three receptor binding domains on a single S trimer. The top candidates neutralize SARS-CoV-2 variants of concern with IC 50 values in the low pM range, resist viral escape, and provide protection in highly vulnerable human ACE2-expressing transgenic mice, both prophylactically and therapeutically. Our integrated workflow promises to accelerate the design of mutationally resilient therapeutics for pandemic preparedness. ONE-SENTENCE SUMMARY: We designed, developed, and characterized potent, trivalent miniprotein binders that provide prophylactic and therapeutic protection against emerging SARS-CoV-2 variants of concern.

19.
Sci Transl Med ; 13(595)2021 05 26.
Artículo en Inglés | MEDLINE | ID: mdl-33941621

RESUMEN

The rapid spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has gravely affected societies around the world. Outbreaks in different parts of the globe have been shaped by repeated introductions of new viral lineages and subsequent local transmission of those lineages. Here, we sequenced 3940 SARS-CoV-2 viral genomes from Washington State (USA) to characterize how the spread of SARS-CoV-2 in Washington State in early 2020 was shaped by differences in timing of mitigation strategies across counties and by repeated introductions of viral lineages into the state. In addition, we show that the increase in frequency of a potentially more transmissible viral variant (614G) over time can potentially be explained by regional mobility differences and multiple introductions of 614G but not the other variant (614D) into the state. At an individual level, we observed evidence of higher viral loads in patients infected with the 614G variant. However, using clinical records data, we did not find any evidence that the 614G variant affects clinical severity or patient outcomes. Overall, this suggests that with regard to D614G, the behavior of individuals has been more important in shaping the course of the pandemic in Washington State than this variant of the virus.


Asunto(s)
COVID-19 , Genoma Viral , SARS-CoV-2 , COVID-19/virología , Brotes de Enfermedades , Humanos , Filogenia , SARS-CoV-2/genética , Washingtón/epidemiología
20.
J Clin Microbiol ; 59(8): e0007421, 2021 07 19.
Artículo en Inglés | MEDLINE | ID: mdl-33789959

RESUMEN

Transrenal urine cell-free DNA (cfDNA) is a promising tuberculosis (TB) biomarker, but is challenging to detect because of the short length (<100 bp) and low concentration of TB-specific fragments. We aimed to improve the diagnostic sensitivity of TB urine cfDNA by increasing recovery of short fragments during sample preparation. We developed a highly sensitive sequence-specific purification method that uses hybridization probes immobilized on magnetic beads to capture short TB cfDNA (50 bp) with 91.8% average efficiency. Combined with short-target PCR, the assay limit of detection was ≤5 copies of cfDNA in 10 ml urine. In a clinical cohort study in South Africa, our urine cfDNA assay had 83.7% sensitivity (95% CI: 71.0 to 91.5%) and 100% specificity (95% CI: 86.2 to 100%) for diagnosis of active pulmonary TB when using sputum Xpert MTB/RIF as the reference standard. The detected cfDNA concentration was 0.14 to 2,804 copies/ml (median 14.6 copies/ml) and was inversely correlated with CD4 count and days to culture positivity. Sensitivity was nonsignificantly higher in HIV-positive (88.2%) compared to HIV-negative patients (73.3%), and was not dependent on CD4 count. Sensitivity remained high in sputum smear-negative (76.0%) and urine lipoarabinomannan (LAM)-negative (76.5%) patients. With improved sample preparation, urine cfDNA is a viable biomarker for TB diagnosis. Our assay has the highest reported accuracy of any TB urine cfDNA test to date and has the potential to enable rapid non-sputum-based TB diagnosis across key underserved patient populations.


Asunto(s)
Ácidos Nucleicos Libres de Células , Tuberculosis Pulmonar , Estudios de Cohortes , Infecciones por VIH , Humanos , Mycobacterium tuberculosis/genética , Sensibilidad y Especificidad , Sudáfrica , Esputo , Tuberculosis Pulmonar/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...