Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Life (Basel) ; 14(8)2024 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-39202739

RESUMEN

Hand disorders can reduce wrist range of motion (ROM). The SARS-CoV-2 pandemic highlighted challenges in routine follow-up exams, making telemedicine a viable solution. This study evaluates the feasibility and accuracy of patient self-measured wrist ROM using a self-designed goniometer template. The template was designed to measure flexion/extension and radial/ulnar abduction movements. A cohort of 50 adults (25 males/25 females) participated in this prospective study. The exclusion criteria included wrist immobilization and ages outside of 18-65 years. Participants self-assessed their wrist ROM with the goniometer template. Measurements were independently performed by a student and a specialist using standard goniometry, as well as a resident using the self-designed goniometer. The results were blinded for unbiased analysis. Mean differences in ROM varied across movement directions, with minimal differences for ulnar abduction and more substantial deviations for radial abduction, extension and flexion. The patient-specialist comparison showed deviations below 5 degrees for flexion and ulnar abduction in 50% of cases. Telemedicine, expanded by the COVID-19 pandemic, offers significant potential for hand rehabilitation. Current methods of ROM assessment lack cost-effectiveness and simplicity. Our method, demonstrating comparable accuracy for most movements, provides a cost-effective, reliable alternative for remote ROM assessment, enhancing telemedicine practices in hand rehabilitation.

2.
Artículo en Alemán | MEDLINE | ID: mdl-39008991

RESUMEN

INTRODUCTION: Although multiple advances have been made in finger defect reconstruction, cross-finger flaps remain an important reconstructive tool. However, data on long-term results are scarce in the literature. This study aimed to assess the clinical and subjective long-term outcomes of patients who underwent cross-finger flap reconstruction for palmar digital and fingertip defects. PATIENTS AND METHODS: Between January 2003 and July 2022, 35 patients (31 male, 4 female, mean age: 59.0 years±20.1) were screened and included in the study. The data were obtained through a clinical examination, a Quick-DASH score and a self-designed questionnaire. Clinical outcomes were assessed by evaluating the range of motion (ROM) of the reconstructed finger and the donor finger compared with the contralateral uninjured hand. In addition to ROM, a static two-point separation test was performed to assess the sensory function of the reconstructed finger. The follow-up period was between 1 year and 19 years (mean: 12.6 years±6.1). RESULTS: There was no significant difference in terms of ROM between the reconstructed finger and the donor finger compared with the contralateral uninjured hand. All patients reported normal discrimination between sharp and blunt objects. However, there was a significant difference in two-point discrimination between the reconstructed finger and the healthy contralateral finger (p<0.05). The average Quick-DASH score was 5.1 points. Satisfaction with the functional outcome in terms of mobility and load-bearing capacity of the cross-finger flap averaged 8.1 out of 10 points. Satisfaction with the aesthetic outcome of the reconstructed finger averaged 7.7 out of 10 points. In 4 cases, persistent pain was reported when the reconstructed finger was under stress. No cases of pain at rest were reported. CONCLUSION: In the long run, cross-finger flaps are a safe and effective reconstructive procedure for covering defects in palmar injuries of the finger and fingertip amputation. They represent a simple, reliable, long-lasting reconstructive technique. The necessary temporary iatrogenic syndactyly does not lead to long-term limitations in the range of motion.

3.
J Clin Med ; 13(14)2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-39064065

RESUMEN

Background: Slow distraction of contracted joints is a well-established treatment in far-advanced stages of Dupuytren's disease (DD). To assess finger perfusion and avoid malperfusion, we studied near infrared spectroscopy (NIRS) to evaluate the maximum extent of distraction that would not harm microcirculation to the finger. This technique also allows an optimized treatment in accordance with sufficient blood perfusion during distraction. Methods: Eligible patients with stage IV finger contractures who needed treatment for Dupuytren's contracture were included and prospectively investigated. The operation was performed with local anaesthesia. First, the Dupuytren strand of the treated finger was dissected in the palm to allow distraction. Under X-ray control, the distraction device was applied. Then, slow distraction of the treated joint was performed to evaluate the finger perfusion. To assess perfusion of the treated finger, NIRS was used to measure tissue oxygen saturation. If impaired finger perfusion was detected, traction was reduced until sufficient oxygen levels and perfusion patterns were reestablished. Results: NIRS was performed after application of the distraction device in seven cases. We treated six male and one female patient (mean age 70 years, range 51-80 years). Rapid distraction resulted in malperfusion of the treated fingers. Using NIRS proved to render reliable and reproducible information on finger perfusion and oxygenation in all seven patients. Conclusions: Application of NIRS enhances safety in the treatment of far-advanced DD finger contractures with an external skeletal distraction device. It is non-invasive, reproducible, easy to use and allows for an individualized adapted distraction velocity.

4.
J Pers Med ; 14(6)2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38929774

RESUMEN

BACKGROUND: In reconstructive surgery, local flaps might develop tissue necrosis or partial flap loss especially after previous irradiation, which may be necessary in many tumor entities. The application of stem cells seems promising to improve flap perfusion and might be a possible solution to optimize flap survival. METHODS: Twenty rats received harvesting of bilateral random pattern fasciocutaneous flaps. The right flaps received 20 Gy ionizing radiation 4 weeks prior to the surgery, while the left flaps served as the non-irradiated control. After flap harvest, four different stem cell mixtures (5 × 106 ASC, ASC-HUVEC, MSC, MSC-HUVEC) were applied under both right and left flaps using 1 mL fibrin glue as the delivery vehicle. Flap size and its necrotic area were examined clinically. Two weeks after the surgery, HE staining and immunohistochemical staining for CD68 and ERG, as well as PCR analysis (Interleukin 6, HIF-1α and VEGF), were performed. RESULTS: Application of ASCs, ASCs-HUVECs and MSCs resulted in a lower number of CD68-stained cells compared to the no cell group. The expression of Hif1α was higher in the ASC group compared to those in the MSC and previously treated no cell groups. Treatment with MSCs and MSCs-HUVECs prevented shrinking of the flaps in this series. CONCLUSION: Application of ASCs, MSCs and ASCs-HUVECs was shown to have an antiinflammatory effect. Treatment with MSCs and MSCs-HUVECs can prevent early shrinking of the flaps.

5.
Arch Orthop Trauma Surg ; 144(6): 2899-2903, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38850419

RESUMEN

BACKGROUND: Patient informed consent is a crucial subject in preoperative care of patients before elective hand surgery, ensuring that patients have the necessary information and a comprehensive understanding to make autonomous decisions. The use of video-based informed consent systems is an innovative concept to enhance the consent process with multimedia tools. In addition to the conventional process, mostly relying on verbal communication and written documents, the video-based approach aims to present information in a standardized and visually appealing format. METHODS: In this study, 33 patients were asked to watch a video on a tablet about the planned elective hand surgery after a conventional pre-treatment consultation including informed consent throughout verbal explanations and paper forms by an attending physician or resident. All patients were asked to complete a questionnaire after watching the video. RESULTS: An overwhelming majority of participants, specifically 97.0%, stated that the video improved their understanding of the upcoming surgery. 90.9% of the participant would refer the video to other patients undergoing elective hand surgery, while 72.7% of participants indicated that they would have appreciated the opportunity to view an informational video before undergoing different types of surgeries in the past. CONCLUSION: The use of a video-based patient information system in elective hand surgery had a positive impact on patient education and satisfaction with the informed consent process. Therefore, it is a powerful tool in preoperative management to guarantee a standardized and educative informed consent.


Asunto(s)
Procedimientos Quirúrgicos Electivos , Mano , Consentimiento Informado , Grabación en Video , Humanos , Consentimiento Informado/normas , Mano/cirugía , Femenino , Persona de Mediana Edad , Masculino , Adulto , Anciano , Educación del Paciente como Asunto/métodos , Encuestas y Cuestionarios , Satisfacción del Paciente , Adulto Joven
6.
J Clin Med ; 13(8)2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38673438

RESUMEN

Background: The aim of this study was to examine the potential benefit that may be achieved through the introduction of technical innovations and the incorporation of mesh for fascial donor site closure in uni- and bilateral autologous breast reconstruction with abdominal tissue. Methods: A retrospective single-center review of all breast reconstructions with a DIEP or MS-TRAM flap between January 2004 and December 2019 was performed. Donor and recipient site complications and operation times were evaluated before and after the implementation of coupler anastomoses, preoperative computed tomography angiography (CTA), indocyanine green (ICG) angiography, and the inclusion of mesh in donor site repair. Results: A total of 396 patients were included, accounting for 447 flaps. Operation time was significantly shorter in unilateral reconstructions after the implementation of CTA (p < 0.0001). ICG angiography significantly reduced the rates of partial flap loss (p = 0.02) and wound healing disorders (p = 0.02). For unilateral reconstructions, abdominal bulging or hernia was observed more often in MS1-TRAM flaps without synthetic mesh repair (p = 0.001), whereas conservatively treated seroma developed more frequently after mesh implantation (p = 0.03). Conclusions: Recent technological advancements developed over the past few decades have made a substantial impact on decreasing surgical duration and enhancing procedure safety.

7.
Chirurgie (Heidelb) ; 95(3): 247-258, 2024 Mar.
Artículo en Alemán | MEDLINE | ID: mdl-38372741

RESUMEN

Massive weight loss following bariatric surgery is often accompanied by functional impairments due to the resulting excess skin and soft tissues. To achieve both functional reconstruction and restoration of the body silhouette, it is imperative to undergo body contouring surgery involving the strategic transposition of tissues. Several surgical techniques are available for the affected body regions and their application for treatment is determined by the unique circumstances specific to each patient. When conducted by skilled practitioners, postbariatric body reconstruction can be executed safely, leading to outcomes that are both functionally and esthetically satisfying, ultimately contributing to an enhanced quality of life for patients. This article provides the fundamental principles for patient selection, surgical preparation, treatment planning, surgical techniques and the postoperative care following bariatric surgery.


Asunto(s)
Cirugía Bariátrica , Contorneado Corporal , Procedimientos de Cirugía Plástica , Cirugía Plástica , Humanos , Calidad de Vida , Contorneado Corporal/métodos , Cirugía Bariátrica/efectos adversos
8.
J Pers Med ; 13(10)2023 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-37888125

RESUMEN

BACKGROUND: Irradiation plays an important role in the oncological treatment of various tumor entities. The aim of the study was to investigate the influence of different irradiation regimens on random-pattern flaps at the molecular and histopathological levels. METHODS: Twenty-five rats underwent harvesting of bilateral random-pattern fasciocutaneous flaps. The right flaps received irradiation, while the left flaps served as non-irradiated intraindividual controls. Five rats served as a non-irradiated control group. Four different irradiation regimens with give rats each were tested: 20 Gy postoperatively, 3 × 12 Gy postoperatively, 20 Gy preoperatively, and 3 × 12 Gy preoperatively. Two weeks after surgery, HE staining and immunohistochemical staining for CD68 and ERG, as well as PCR analysis to detect Interleukin 6, HIF-1α, and VEGF, were performed. RESULTS: A postoperative cumulative higher dose of irradiation appeared to result in an increase in necrosis, especially in the superficial layers of the flap compared to preoperative or single-stage irradiation. In addition, we observed increased expression of VEGF and HIF-1α in all irradiation groups. CONCLUSION: Even though no statistically significant differences were found between the different groups, there was a tendency for fractional postoperative irradiation with a higher total dose to have a more harmful effect compared to preoperative or single-dose irradiation.

9.
Chirurgie (Heidelb) ; 94(2): 130-137, 2023 Feb.
Artículo en Alemán | MEDLINE | ID: mdl-36255475

RESUMEN

Irrespective of numerous technical developments, lymphadenectomy remains a necessary component of surgical tumor therapy. Depending on the extent and anatomical localization, complications associated with the lymph vessels such as lymphoceles, lymphatic fistulas or secondary lymphedema can occur with varying frequency, despite a meticulous dissection technique. Chronic lymph fistulas or lymphoceles often require interventional or surgical procedures. Pedicled or free microsurgical flaps are often required in the case of coexisting wound healing disorders or skin soft tissue defects, especially in an irradiated area. For secondary lymphedema a number of conservative and surgical treatment methods have been established. Adequate guideline-based conservative treatment is the method of first choice. If this does not lead to the desired result, microsurgical reconstructive, deviating or resecting procedures are available.


Asunto(s)
Fístula , Linfedema , Linfocele , Humanos , Linfocele/terapia , Linfocele/cirugía , Escisión del Ganglio Linfático/efectos adversos , Escisión del Ganglio Linfático/métodos , Ganglios Linfáticos/cirugía , Ganglios Linfáticos/patología , Linfedema/etiología , Linfedema/cirugía , Fístula/etiología , Fístula/cirugía
10.
Front Surg ; 9: 962450, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36117816

RESUMEN

Background: Free vascularized medial femoral condyle (MFC) bone grafts can lead to increased vascularity of the proximal pole and restore scaphoid architecture in scaphoid nonunions. The intraoperative perfusion assessment of the bone graft is challenging because the conventional clinical examination is difficult. Indocyanine green (ICG) angiography has previously been shown to provide a real-time intraoperative evaluation of soft tissue perfusion in reconstructive surgery. The present study investigated the utility of ICG angiography in patients treated with a free medial femoral condyle graft for scaphoid nonunions. Methods: We performed a retrospective analysis of patients with scaphoid nonunions, in which ICG angiography was used intraoperatively for perfusion assessment. The medical records, radiographs, intraoperative imaging, and operative reports of all patients were reviewed. Intraoperative ICG dye was administered intravenously, and laser angiography was performed to assess bone perfusion. The scaphoid union was examined using postoperative CT scans. Results: Two patients had documented osteonecrosis of the proximal pole at the time of surgery. Four patients received a nonvascularized prior bone graft procedure, and a prior spongiosa graft procedure was performed in one patient. The mean time from injury to the MFC bone graft surgery was 52.7 months, and the mean time from prior failed surgery was 10.4 months. Perfusion of the vascular pedicle of the MFC and the periosteum could be detected in all patients. In two patients, even perfusion of the cancellous bone could be demonstrated by ICG angiography. Following transplantation of the bone graft, patency of the vascular anastomosis and perfusion of the periost were confirmed by ICG angiography in the assessed cases. No additional surgery regarding a salvage procedure for a scaphoid nonunion advanced collapse was necessary for the further course. Conclusion: ICG-angiography has shown to be a promising tool in the treatment of scaphoid nonunion with medial femoral condyle bone grafts. It enables intraoperative decision making by assessment of the microvascular blood supply of the periosteum and the vascular pedicle of the MFC bone graft. Further studies need to evaluate the impact on union rates in a long-term follow-up.

11.
J Clin Med ; 11(17)2022 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-36079063

RESUMEN

The effects of topical negative pressure therapy (TNP) have been a subject of research for many years. In this study, we investigated new imaging devices to detect clinical changes that TNP causes on healthy tissue and identified differences in microcirculation created by different pressure levels. We used near-infrared spectroscopy (NIS), thermography, and a vein illuminator to measure the differences in oxygen saturation, tissue temperature, and vein pattern. A control group (-125 mmHg) and three comparison groups with only TNP dressing (Group 1), -25 mmHg (Group 2), and -175 mmHg (Group 3) were established. Thirty minutes of TNP on intact skin was followed by 30 min of resting. A total of 24 participants were measured by all imaging devices at predetermined time points. Oxygen saturation and skin temperature increased by 8.07% and 1.67 °C for the control group, 4.00% and 1.65 °C for Group 2, and 8.45% and 1.68 °C for Group 3. Group 1 showed a slight increase in oxygen saturation and a 2.7 °C increase in skin temperature. Over the 30 min following removal of TNP, oxygen saturation and temperature decreased gradually for all groups. The vein illuminator did not show significant differences in the venous pattern or flow. Our study showed that higher negative pressure values resulted in higher oxygen saturation and higher tissue temperature.

12.
J Clin Med ; 11(17)2022 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-36079169

RESUMEN

BACKGROUND: The exact influence of tourniquet ischemia on a treated extremity remains unclear. METHODS: Twenty patients received an operation on one hand under tourniquet ischemia. Twenty healthy volunteers received 10 min of tourniquet ischemia on one of their arms. Measurements of tissue oxygen saturation using near-infrared reflectance-based imaging and skin temperature of the dorsum of the hand were performed at five different timepoints (t0 was performed just before the application of the tourniquet ischemia, t1 directly after the application of the tourniquet ischemia, t2 before the release of the ischemia, t3 directly after the release of the ischemia, and t4 on the following day). RESULTS: In both groups, tissue oxygen saturation dropped after the application of the tourniquet ischemia compared to t0 and increased after the release of the tourniquet ischemia. In the patient group, tissue oxygen saturation at t4 was higher compared to t0; in contrast, the level of tissue oxygen saturation in the participant group dropped slightly at t4 compared to t0. The measured skin temperature in the patient group showed an increase during the observation period, while it continuously decreased in the group of healthy participants. CONCLUSIONS: Short-term ischemia did not appear to permanently restrict perfusion in this study design. The non-invasive imaging modalities used were easy to handle and allowed repetitive measurement.

13.
J Pers Med ; 12(3)2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-35330378

RESUMEN

BACKGROUND: While surgical therapy for Dupuytren's disease is a well-established standard procedure, severe joint flexion deformities in advanced Dupuytren's disease remain challenging to treat. Skeletal distraction has proven to be an additional treatment option. METHODS: We analyzed the surgical treatment algorithm, including the application of a skeletal distraction device, in patients with a flexion deformity due to Dupuytren's disease, Iselin stage III or IV, who were operated on from 2003 to 2020 in our department. RESULTS: From a total of 724 patients, we included the outcome of 55 patients' fingers in this study, who had undergone additional skeletal joint distraction with our Erlangen device. Additional fasciotomy or fasciectomy, in a one- or two-staged procedure, was performed in all patients, according to the individual findings and necessities. The range of motion of the PIP joint improved from 12° to 53°. A number of complications, in all steps of the treatment, were noted in a total of 36.4% of patients, including the development of fractures (16.4%), followed by vessel injury, pin infections, and complex regional pain syndrome (5%). CONCLUSIONS: Additional skeletal distraction improves the range of motion of severely contracted joints in Dupuytren's disease. Nevertheless, careful patient selection is necessary, due to the moderate rate of complications.

14.
J Pers Med ; 12(3)2022 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-35330443

RESUMEN

Decellularized whole muscle constructs represent an ideal scaffold for muscle tissue engineering means as they retain the network and proteins of the extracellular matrix of skeletal muscle tissue. The presence of a vascular pedicle enables a more efficient perfusion-based decellularization protocol and allows for subsequent recellularization and transplantation of the muscle construct in vivo. The goal of this study was to create a baseline for transplantation of decellularized whole muscle constructs by establishing an animal model for investigating a complete native muscle isolated on its pedicle in terms of vascularization and functionality. The left medial gastrocnemius muscles of 5 male Lewis rats were prepared and raised from their beds for in situ muscle stimulation. The stimulation protocol included twitches, tetanic stimulation, fatigue testing, and stretching of the muscles. Peak force, maximum rate of contraction and relaxation, time to maximum contraction and relaxation, and maximum contraction and relaxation rate were determined. Afterwards, muscles were explanted and transplanted heterotopically in syngeneic rats in an isolation chamber by microvascular anastomosis. After 2 weeks, transplanted gastrocnemius muscles were exposed and stimulated again followed by intravascular perfusion with a contrast agent for µCT analysis. Muscle constructs were then paraffin embedded for immunohistological staining. Peak twitch and tetanic force values all decreased significantly after muscle transplantation while fatigue index and passive stretch properties did not differ between the two groups. Vascular analysis revealed retained perfused vessels most of which were in a smaller radius range of up to 20 µm and 45 µm. In this study, a novel rat model of heterotopic microvascular muscle transplantation in an isolation chamber was established. With the assessment of in situ muscle contraction properties as well as vessel distribution after 2 weeks of transplantation, this model serves as a base for future studies including the transplantation of perfusion-decellularized muscle constructs.

15.
J Pers Med ; 12(2)2022 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-35207725

RESUMEN

BACKGROUND: Assessment of tissue perfusion after irradiation of random pattern flaps still remains a challenge. METHODS: Twenty-five rats received harvesting of bilateral random pattern fasciocutaneous flaps. Group 1 served as nonirradiated control group. The right flaps of the groups 2-5 were irradiated with 20 Gy postoperatively (group 2), 3 × 12 Gy postoperatively (group 3), 20 Gy preoperatively (group 4) and 3 × 12 Gy preoperatively (group 5). Imaging with infrared thermography, indocyanine green angiography and near-infrared reflectance-based imaging were performed to detect necrotic areas of the flaps. RESULTS: Analysis of the percentage of the necrotic area of the irradiated flaps showed a statistically significant increase from day 1 to 14 only in group 5 (p < 0.05). Indocyanine green angiography showed no differences (p > 0.05) of the percentage of the nonperfused area between all days in group 1 and 3, but a decrease in group 2 in both the left and the right flaps. Infrared thermography and near-infrared reflectance-based imaging did not show evaluable differences. CONCLUSION: Indocyanine green angiography is more precise in prediction of necrotic areas in random pattern skin flaps when compared to hyperspectral imaging, thermography or clinical impression. Preoperative fractional irradiation with a lower individual dose but a higher total dose has a more negative impact on flap perfusion compared to higher single stage irradiation.

18.
Int Wound J ; 18(6): 932-939, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34128314

RESUMEN

The influence of topical negative pressure application (TNPA) on tissue perfusion still remains controversial. TNPA was applied for 30 minutes on intact skin of 21 healthy participants. Measurements of tissue oxygen saturation and tissue temperature as signs of tissue perfusion were performed before application of the TNPA, directly after removal of the TNPA and 5, 10, 15, 20, and 30 minutes after removal of the dressing using the near infrared imaging (NIRI) and a thermal imaging camera. Tissue oxygen saturation showed an increase from 67.7% before applying the TNPA to 76.1% directly after removal of TNPA, followed by a decrease of oxygen saturation 30 minutes after removal of TNPA. The measured temperature of the treated skin area increased from 32.1°C to 36.1°C after removal of TNPA with a consecutive decrease of the temperature 30 minutes after removal. TNPA resulted in both a higher tissue oxygen saturation and a higher skin temperature after 30 minutes compared to the beginning. TNPA increases both tissue oxygen saturation and skin temperature as sign of an increase of tissue perfusion. NIRI and thermal imaging proved to be useful for measuring changes in tissue perfusion.


Asunto(s)
Terapia de Presión Negativa para Heridas , Humanos , Oxígeno , Perfusión , Piel/diagnóstico por imagen , Temperatura Cutánea
19.
Med Sci Monit ; 27: e929814, 2021 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-33883543

RESUMEN

BACKGROUND Treating advanced finger joint contractures from Dupuytren disease remains a challenge. We evaluated the effectiveness of a skeletal distraction device versus alternative treatment options. MATERIAL AND METHODS We analyzed the surgical treatment of contracted finger joints in stage III and stage IV Dupuytren's disease over a 10-year period. Data were obtained from inpatient and outpatient medical records, including postoperative clinical examinations and extended Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire scores. Complications of infection, postoperative pain, and wound healing disorders were recorded. RESULTS A total of 79 patients (83 hands) were assigned to 2 treatment groups. Patients in group 1 underwent an initial open transection of the main fibrous cord, Z-plasty, distraction with the Erlangen external distraction device, and fasciectomy. The distraction period was 13 to 81 days (mean 31 days). Group 2 underwent a conventional single-stage fasciectomy and arthrolysis. DASH scores and subjective patient satisfaction were lower in group 1 (20.7/33%) than in group 2 (10.3/50%). However, the staged approach of group 1 to treat proximal interphalangeal joint contractures in the long term (improvement >40%) was more effective than the approach of group 2 (>33%). Distraction device pin infections occurred in 20% of hands. Postoperative pain and complex regional pain syndrome type I occurred in 25% of hands in group 1 and 3% in group 2. CONCLUSIONS A screw thread driven external fixation device is useful in end-stage Dupuytren's finger joint contractures. It is indicated when joint contractures are advanced and simple arthrolysis is insufficient.


Asunto(s)
Contractura de Dupuytren/cirugía , Equipos y Suministros , Articulaciones de los Dedos/fisiología , Procedimientos Ortopédicos/métodos , Cuidados Posoperatorios/métodos , Adulto , Anciano , Anciano de 80 o más Años , Tornillos Óseos , Progresión de la Enfermedad , Fijadores Externos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Rango del Movimiento Articular , Resultado del Tratamiento
20.
J Plast Reconstr Aesthet Surg ; 74(10): 2527-2536, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33814327

RESUMEN

BACKGROUND: The muscle-sparing latissimus dorsi flap poses an alternative to the conventional latissimus dorsi flap when a defect requires a smaller flap volume with a long vascular pedicle. The aim of the study was to analyze the functional outcome following muscle-sparing versus conventional harvest of a latissimus dorsi flap. MATERIAL AND METHODS: Patients who received a muscle-sparing latissimus dorsi muscle flap transplantation (group 1) and patients with a complete latissimus dorsi muscle flap harvest (group 2) for defect reconstruction at the University Hospital of Erlangen between 2007 and 2016 were examined. The evaluation included a physical examination with the measurement of strength and range of motion of the shoulder of both the donor side as well as the nonoperated side. Furthermore, the DASH score was evaluated. Additionally, patients in group 1 received a neurophysiological examination. RESULTS: The DASH score did not show statistically significant differences between both groups. Both strength (p = 0.031) and range of motion (p<0.05) of the shoulder of the donor side were statistically significantly lower than the nonoperated side in group 2, while no difference was found in group 1. The neurophysiological examination in group 1 showed a reduced nerve conduction velocity of the donor side as compared to the nonoperated side in most patients (60% and n = 3). CONCLUSION: Harvesting the muscle-sparing latissimus dorsi flap leads to less functional impairments of the shoulder than harvesting the complete latissimus dorsi flap.


Asunto(s)
Fuerza Muscular , Procedimientos de Cirugía Plástica , Complicaciones Posoperatorias , Rango del Movimiento Articular , Músculos Superficiales de la Espalda/trasplante , Colgajos Quirúrgicos , Femenino , Estado Funcional , Humanos , Masculino , Persona de Mediana Edad , Conducción Nerviosa/fisiología , Examen Neurológico/métodos , Tratamientos Conservadores del Órgano/métodos , Evaluación de Procesos y Resultados en Atención de Salud , Examen Físico/métodos , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/fisiopatología , Complicaciones Posoperatorias/prevención & control , Procedimientos de Cirugía Plástica/efectos adversos , Procedimientos de Cirugía Plástica/métodos , Hombro/fisiopatología , Traumatismos de los Tejidos Blandos/etiología , Traumatismos de los Tejidos Blandos/cirugía , Colgajos Quirúrgicos/efectos adversos , Colgajos Quirúrgicos/irrigación sanguínea , Colgajos Quirúrgicos/clasificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA