During surgical procedures, cotton abdominal swabs with their high absorptive capacity and malleability are used to retain organs and absorb blood or other body fluids. Such properties of the natural material cotton are advantageous for most operations, but in cardiopulmonary bypass (CPB) surgery, a high blood volume can accumulate in the thoracic cavity that is quickly retransfused via the heart-lung machine (HLM). This common practice is supposed to be safe due to the high anticoagulation. However, in vitro analyses showed that blood cells and plasma proteins were activated despite a high anticoagulation, which can propagate especially an inflammatory response in the patient. Thus, we investigated patients' blood during CPB surgery for inflammatory and coagulation-associated activation after contact to the HLM and either cotton or synthetic abdominal swabs. Contact with cotton significantly increased thrombocyte and neutrophil activation measured as ß-thromboglobulin and PMN-elastase secretion, respectively, compared to synthetic abdominal swabs. Both inflammatory cytokines, interleukin (IL) 1ß and IL6, were also significantly increased in the cotton over the synthetic patient group, while SDF-1α was significantly lower in the synthetic group. Our data show for the first time that cotton materials can activate platelets and leukocytes despite a high anticoagulation and that this activation is lower with synthetic materials. This additional activation due to the material on top of the activation exerted by the tissue contact that blood is exposed to during CPB surgery can propagate further reactions in patients after surgery, which poses a risk for this already vulnerable patient group.


Cardiac Surgical Procedures/instrumentation , Platelet Activation , Tampons, Surgical , Textiles , Aged , Blood Platelets/physiology , Cardiac Surgical Procedures/methods , Cotton Fiber , Cytokines/blood , Female , Heart-Lung Machine , Humans , Inflammation/blood , Leukocyte Count , Male , Middle Aged , Surgical Sponges
2.
J Biomed Mater Res B Appl Biomater ; 107(6): 1877-1888, 2019 08.
Article En | MEDLINE | ID: mdl-30467962

Cotton-based surgical invasive devices with their desired hemostyptic properties have been used for decades in the surgical field. However, in cardiac surgery using the heart-lung machine with direct retransfusion of suction blood, activated blood may re-enter the circulation without filtration and may trigger a cascade reaction leading to systemic inflammation and thrombosis. We therefore set out to evaluate the inflammatory potential of untreated and pyrogen-impregnated cotton-based surgical invasive medical devices. After incubation of the swabs with whole blood or PBMC, the cell-free supernatant was investigated for IL1ß and IL6. While the reaction of human whole blood toward cotton swabs could not be influenced by any sterilization technique, dry heat and gamma-irradiation were able to diminish the inflammatory reaction of PBMC toward the material and the used pyrogens. In conclusion, using PBMC in direct contact to cotton we are the first to establish a suitable test method for quantification of the pyrogenic/inflammatory activity of this material. The unaltered reaction of whole blood, however, suggests a crosstalk of cells and plasma proteins in the inflammation activation that is not prevented by sterilization of the swabs. This new in vitro testing methodology may help to better display the clinical situation during development of new materials. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1877-1888, 2019.


Cardiac Surgical Procedures/instrumentation , Cotton Fiber , Leukocytes, Mononuclear/metabolism , Materials Testing , Sterilization , Humans , Leukocytes, Mononuclear/pathology
...