Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
BMJ Case Rep ; 14(9)2021 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-34580135

RESUMEN

Spontaneous renal artery dissection is a rare condition with an often non-specific presentation, resulting in a challenging diagnosis for clinicians. This is the case of a 39-year-old man who presented with an acute-onset right flank pain, mild neutrophilia and sterile urine. CT of abdomen and pelvis showed a patchy hypodense area in the right kidney originally thought to represent infection. He was treated as an atypical pyelonephritis with antibiotics and fluids. When his symptoms failed to improve, a diagnosis of renal infarction was considered and CT angiogram of the aorta revealed a spontaneous renal artery dissection. He was managed conservatively with systemic anticoagulation, antihypertensive treatment and analgesia and discharged home with resolution of his symptoms and normal renal function.


Asunto(s)
Disección Aórtica , Enfermedades Renales , Adulto , Disección Aórtica/diagnóstico por imagen , Disección , Humanos , Infarto/diagnóstico por imagen , Masculino , Arteria Renal/diagnóstico por imagen
2.
J Cachexia Sarcopenia Muscle ; 9(2): 295-305, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29271097

RESUMEN

BACKGROUND: Nutrition screening on admission to hospital is mandated in many countries, but to date, there is no consensus on which tool is optimal in the oncology setting. Wasting conditions such as cancer cachexia (CC) and sarcopenia are common in cancer patients and negatively impact on outcomes; however, they are often masked by excessive adiposity. This study aimed to inform the application of screening in cancer populations by investigating whether commonly used nutritional screening tools are adequately capturing nutritionally vulnerable patients, including those with abnormal body composition phenotypes (CC, sarcopenia, and myosteatosis). METHODS: A prospective study of ambulatory oncology outpatients presenting for chemotherapy was performed. A detailed survey incorporating clinical, nutritional, biochemical, and quality of life data was administered. Participants were screened for malnutrition using the Malnutrition Universal Screening Tool (MUST), Malnutrition Screening Tool (MST), and the Nutritional Risk Index (NRI). Computed tomography (CT) assessment of body composition was performed to diagnose CC, sarcopenia, and myosteatosis according to consensus criteria. RESULTS: A total of 725 patients (60% male, median age 64 years) with solid tumours participated (45% metastatic disease). The majority were overweight/obese (57%). However, 67% were losing weight, and CT analysis revealed CC in 42%, sarcopenia in 41%, and myosteatosis in 46%. Among patients with CT-identified CC, the MUST, MST, and NRI tools categorized 27%, 35%, and 7% of them as 'low nutritional risk', respectively. The percentage of patients with CT-identified sarcopenia and myosteatosis that were categorised as 'low nutritional risk' by MUST, MST and NRI were 55%, 61%, and 14% and 52%, 50%, and 11%, respectively. Among these tools, the NRI was most sensitive, with scores <97.5 detecting 85.8%, 88.6%, and 92.9% of sarcopenia, myosteatosis, and CC cases, respectively. Using multivariate Cox proportional hazards models, NRI score < 97.5 predicted greater mortality risk (hazard ratio 1.8, confidence interval: 1.2-2.8, P = 0.007). CONCLUSIONS: High numbers of nutritionally vulnerable patients, with demonstrated abnormal body composition phenotypes on CT analysis, were misclassified by MUST and MST. Caution should be exercised when categorizing the nutritional risk of oncology patients using these tools. NRI detected the majority of abnormal body composition phenotypes and independently predicted survival. Of the tools examined, the NRI yielded the most valuable information from screening and demonstrated usefulness as an initial nutritional risk grading system in ambulatory oncology patients.


Asunto(s)
Caquexia/diagnóstico por imagen , Desnutrición/fisiopatología , Neoplasias/complicaciones , Estado Nutricional/fisiología , Sarcopenia/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Caquexia/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neoplasias/patología , Calidad de Vida , Sarcopenia/patología
3.
Am J Clin Oncol ; 40(1): 47-52, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-24685884

RESUMEN

BACKGROUND: Sunitinib is a standard first-line option for metastatic renal cell carcinoma (mRCC). Body composition is a prognostic factor in cancer patients and patients with loss of skeletal muscle mass and fat-free mass (FFM) are prone to dose-limiting toxicity (DLT) during targeted drug therapy. We investigated whether body composition by computed tomography predicted DLT from sunitinib in mRCC. METHODS: Patients with clear cell mRCC receiving sunitinib (50 mg) were included. Skeletal muscle cross-sectional area at L3 was measured by computed tomography. Sarcopenia was defined using published cutoffs. Toxicity was assessed after 4 cycles of the drug. RESULTS: Fifty-five patients (43 male), mean age 64 years were included. Overall, 33% (N=18) of all patients were sarcopenic and of these 12.7% (N=7) were sarcopenic and overweight or obese. DLT occurred in <6 months in 53% of patients (44% male vs. 83% female) and those who experienced DLT were older (68 vs. 60 y), had a lower skeletal muscle index (51.7 vs. 59.4 cm/m), a lower FFM (51.4 vs. 57.7 kg), and received a higher drug dose in mg/kg FFM (0.9 vs. 0.8). Patients with the lowest compared with the highest measurements of skeletal muscle mass experienced more DLT, respectively, 92% versus 57% and experienced on average 5 toxicities versus 2. CONCLUSIONS: Sarcopenia is prevalent in patients with mRCC, is an occult condition in patients with normal/high body mass index, and is a significant predictor of DLT in patients receiving sunitinib. Our results highlight the potential use of baseline body composition to predict toxicity.


Asunto(s)
Antineoplásicos/toxicidad , Composición Corporal , Carcinoma de Células Renales/tratamiento farmacológico , Indoles/toxicidad , Neoplasias Renales/tratamiento farmacológico , Pirroles/toxicidad , Tomografía Computarizada por Rayos X , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Sunitinib
4.
BMJ Case Rep ; 20162016 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-27113788

RESUMEN

A 15-year-old girl with a recent diagnosis of acute lymphoblastic leukaemia was admitted to hospital with pancytopaenia after having received high-dose intrathecal methotrexate 1 day prior. During the next week she had intermittent episodes of alternating hemiparesis associated with speech arrest lasting minutes to hours at a time. The episodes were not associated with altered level of consciousness or headache. MRI of the brain showed features consistent with methotrexate encephalopathy. This report discusses the typical clinical and radiological features of methotrexate neurotoxicity in addition to differential diagnoses and the proposed pathophysiological mechanisms.


Asunto(s)
Apraxias/diagnóstico , Metotrexato/efectos adversos , Síndromes de Neurotoxicidad/diagnóstico , Paresia/diagnóstico , Leucemia-Linfoma Linfoblástico de Células Precursoras/tratamiento farmacológico , Adolescente , Antimetabolitos Antineoplásicos/efectos adversos , Antimetabolitos Antineoplásicos/uso terapéutico , Apraxias/etiología , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Femenino , Humanos , Inyecciones Espinales , Metotrexato/uso terapéutico , Síndromes de Neurotoxicidad/patología , Paresia/etiología
5.
Clin Exp Pharmacol Physiol ; 43(3): 319-26, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26707795

RESUMEN

Manufactured nanomaterials have a variety of medical applications, including diagnosis and targeted treatment of cancer. A series of experiments were conducted to determine the pharmacokinetic, biodistribution and biocompatibility of two novel magnetic nanoparticles (MNPs) in the anaesthetized pig. Dimercaptosuccinic acid (DMSA) coated superparamagnetic iron oxide nanoparticles (MF66-labelled 12 nm, core nominal diameter and OD15 15 nm); at 0.5, or 2.0 mg/kg) were injected intravenously. Particles induced a dose-dependent decrease in blood pressure following administration which recovered to control levels several minutes after injection. Blood samples were collected for a 5-h period and stored for determination of particle concentration using particle electron paramagnetic resonance (pEPR). Organs were harvested post-mortem for magnetic resonance imaging (MRI at 1.5 T field strength) and histology. OD15 (2.0 mg/kg) MNP had a plasma half-life of approximately 15 min. Both doses of the MF66 (0.5 and 2.0 mg/kg) MNP were below detection limits. MNP accumulation was observed primarily in the liver and spleen with MRI scans which was confirmed by histology. MRI also showed that both MNPs were present in the lungs. The results show that further modifications may be required to improve the biocompatibility of these particles for use as diagnostic and therapeutic agents.


Asunto(s)
Compuestos Férricos/química , Compuestos Férricos/farmacocinética , Imanes , Porcinos , Anestesia , Animales , Presión Sanguínea/efectos de los fármacos , Compuestos Férricos/efectos adversos , Compuestos Férricos/sangre , Pulmón/citología , Pulmón/efectos de los fármacos , Imagen por Resonancia Magnética , Tamaño de la Partícula , Distribución Tisular
6.
Clin Nutr ESPEN ; 13: e39-e45, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-28531567

RESUMEN

BACKGROUND: Body composition may influence clinical outcomes of certain chemotherapeutic agents. We examined the prognostic significance of skeletal muscle mass and adipose tissue on docetaxel toxicity and overall survival in patients with metastatic castrate resistant prostate cancer (mCRPC). METHODS: A retrospective review of patients medical records with mCRPC, treated with docetaxel was conducted. Body composition parameters (skeletal muscle mass, muscle attenuation [MA], visceral and subcutaneous adipose tissue) were measured at L3 by computed tomography (CT) and defined using previously established cut points. Toxicity profile was assessed after 3 cycles of the drug and graded according to the National Cancer Institute Common Toxicity Criteria (version 4). Overall survival was analysed. RESULTS: Overall 63 patients, mean age 69 years (SD 8.3), were included. Sarcopenia was present in 47% (n = 30) and of these 26.7% (8/30) were sarcopenic obese. Common toxicities (all grades) observed included fatigue (80.9%), pain (46%), and constipation (34.9%). DLT occurred in 22 (34.9%) patients; of these 10 patients (15.8%) experienced dose reductions and 12 patients (19%) experienced dose terminations. Measurements of adiposity were not predictive of DLT, however 59.1% patients who had a combination of both sarcopenia and low MA experienced DLT compared to 29.3% of patients without sarcopenia and low MA (p = 0.021). Skeletal muscle index and MA were significantly lower in patients who experienced neutropenia (grade I-II) (46.5 cm2/m2 vs. 51.2 cm2/m2, p = 0.005) compared to their counterparts (24.6 HU vs. 32.2 HU, p = 0.044). Neither sarcopenia nor sarcopenic obesity was associated with overall survival. In multivariate analysis, BMI ≥25 kg/m2 (HR: 0.349, CI: 0.156-0.782, p = 0.010) was a significant predictor of longer overall survival and both visceral fat index ≥ median 58.7 cm2/m2 (HR: 2.266 CI: 1.066-4.814, p = 0.033) and anaemia (HR: 2.81, CI: 1.297-6.091, p = 0.009) were significant predictors of shorter overall survival. CONCLUSIONS: Sarcopenia and low MA are associated with neutropenia (grade I-II). Furthermore, presence of anaemia, high volume of visceral fat and BMI <25 kg/m2 are associated with reduced survival in patients with castrate resistant prostate cancer being treated with docetaxel chemotherapy.


Asunto(s)
Composición Corporal/efectos de los fármacos , Metástasis de la Neoplasia , Neoplasias de la Próstata/complicaciones , Neoplasias de la Próstata/tratamiento farmacológico , Taxoides/toxicidad , Adiposidad , Anciano , Anciano de 80 o más Años , Antineoplásicos/uso terapéutico , Composición Corporal/fisiología , Índice de Masa Corporal , Docetaxel , Quimioterapia , Humanos , Grasa Intraabdominal/patología , Masculino , Persona de Mediana Edad , Análisis Multivariante , Músculo Esquelético/patología , Metástasis de la Neoplasia/tratamiento farmacológico , Metástasis de la Neoplasia/fisiopatología , Neutropenia/complicaciones , Obesidad/complicaciones , Pronóstico , Neoplasias de la Próstata/mortalidad , Neoplasias de la Próstata/fisiopatología , Estudios Retrospectivos , Sarcopenia/complicaciones , Grasa Subcutánea/patología , Análisis de Supervivencia , Tomografía Computarizada por Rayos X
7.
Oncol Res Treat ; 37(10): 591-4, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25342510

RESUMEN

BACKGROUND: Lhermitte's sign (LS) is characterized by electric shock-like sensations, spreading along the spine in a cervico-caudal direction and into the arms and legs. It is felt upon flexion of the neck and reflects a myelopathy resulting from damage to sensory axons at the dorsal columns of the cervical spinal cord. In patients with cancer, LS can occur due to direct tumour involvement of the spine or in relation to radiotherapy. Chemotherapy-related LS has only rarely been reported. CASE REPORT: We present the case of a 44-year-old patient treated with platinum- and etoposide-based chemotherapy for metastatic seminoma, who subsequently developed severe disabling LS. The severity and duration of LS in this case exceeds prior reports. We review the literature on chemotherapy-related LS and discuss the practice implications. CONCLUSION: Neuropathy and LS related to cisplatin-based chemotherapy can result in significant adverse effects. Raised awareness of this complication could aid sub-phenotyping of the population most at risk and assist strategies to avert discomfort and disability post chemotherapy.


Asunto(s)
Cisplatino/efectos adversos , Cisplatino/uso terapéutico , Parestesia/inducido químicamente , Parestesia/diagnóstico , Enfermedades del Sistema Nervioso Periférico/inducido químicamente , Enfermedades del Sistema Nervioso Periférico/diagnóstico , Neoplasias Testiculares/tratamiento farmacológico , Adulto , Antineoplásicos/efectos adversos , Antineoplásicos/uso terapéutico , Diagnóstico Diferencial , Humanos , Masculino , Parestesia/prevención & control , Enfermedades del Sistema Nervioso Periférico/prevención & control , Neoplasias Testiculares/complicaciones
10.
Pediatr Radiol ; 39(10): 1095-7, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19547962

RESUMEN

Necrotizing fasciitis (NF) is an uncommon soft-tissue infection in children that carries a high mortality rate. We present a 15-year-old girl with chronic pancytopenia secondary to Fanconi anaemia who developed extensive NF of the lower limb, which unfortunately resulted in a fatal outcome. Immunodeficiency is a known risk factor for the development of this condition. The findings in this case demonstrate that patients with Fanconi anaemia may be susceptible to NF and that the clinical course may be more aggressive due to underlying immunosuppression. Prompt diagnosis of NF is vital in order to initiate appropriate treatment and to optimize patient outcome. Radiological investigation demonstrated extensive soft-tissue gas and destruction affecting the entire lower limb, abdominal wall and retroperitoneum, which led to timely definitive diagnosis and management.


Asunto(s)
Anemia de Fanconi/complicaciones , Anemia de Fanconi/diagnóstico por imagen , Fascitis Necrotizante/complicaciones , Fascitis Necrotizante/diagnóstico por imagen , Pierna/diagnóstico por imagen , Espacio Retroperitoneal/diagnóstico por imagen , Adolescente , Resultado Fatal , Femenino , Humanos , Radiografía
11.
Vascular ; 17(3): 168-71, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19476751

RESUMEN

Aortoduodenal syndrome is a rare complication of an abdominal aortic aneurysm wherein the aneurysm sac obstructs the patient's duodenum. It presents with the symptoms of an upper gastrointestinal tract obstruction and requires surgical intervention to relieve it. Previously, gastric bypass surgery was advocated, but now aortic replacement is the mainstay of treatment. We report a case of a 67-year-old woman whose aortoduodenal syndrome was successfully managed and review the literature on this topic.


Asunto(s)
Aneurisma de la Aorta Abdominal/complicaciones , Enfermedades Duodenales/etiología , Obstrucción Intestinal/etiología , Gastropatías/etiología , Anciano , Aorta/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aortografía , Implantación de Prótesis Vascular , Enfermedades Duodenales/diagnóstico por imagen , Enfermedades Duodenales/cirugía , Duodeno/diagnóstico por imagen , Femenino , Humanos , Obstrucción Intestinal/diagnóstico por imagen , Obstrucción Intestinal/cirugía , Gastropatías/diagnóstico por imagen , Gastropatías/cirugía , Síndrome
12.
J Cardiovasc Magn Reson ; 8(3): 427-33, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16755828

RESUMEN

UNLABELLED: Magnetic resonance (MR) diagnosis of regional left ventricular (LV) dysfunction relies on visual interpretation of cine images that suffers from wide inter-observer variability, especially when performed by readers not specifically trained in the assessment of LV wall motion. Quantitative analysis tools, though widely available, are rarely used because they provide large amounts of detailed information, the interpretation of which requires additional time-consuming processing. We tested the feasibility of fast automated interpretation of regional LV function using computer analysis of this wall motion information. METHODS: Dynamic, ECG-gated, steady-state free precession short-axis images were obtained in 6-10 slices in 28 subjects (10 normal volunteers; 18 patients). Images were reviewed by an expert cardiologist who provided "gold standard" grades (normal, abnormal) for regional wall motion and, independently, by four radiologists. Same images were then analyzed using custom software. Regional fractional area changes computed in normal volunteers were used to obtain the optimal segment- and slice-specific threshold values for automated classification of regional wall motion for each patient. The levels of agreement with the "gold standard" grades were compared between the radiologists and the automated interpretation. RESULTS: While the visual interpretation required 2-5 minute per patient, the automated interpretation required < 1 sec, after endocardial border detection was complete. The automated interpretation resulted in higher sensitivity, specificity, and accuracy (84%, 77%, 79%, respectively) than the radiologists' grades (80%, 76%, 77%, respectively) and eliminated the high interobserver variability. CONCLUSION: Once the endocardial boundaries are defined, computer analysis of the regional wall motion information allows accurate, fully automated, immediate, objective and experience-independent interpretation of regional LV function.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Cinemagnética , Disfunción Ventricular Izquierda/fisiopatología , Función Ventricular Izquierda/fisiología , Automatización , Competencia Clínica , Electrocardiografía , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia , Sensibilidad y Especificidad , Programas Informáticos
13.
J Am Soc Echocardiogr ; 18(8): 779-88, 2005 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16084328

RESUMEN

Our goals were to: (1) develop a technique for 3-dimensional (3D) direct, model-independent quantitative assessment of left ventricular (LV) volume and ejection fraction based on semiautomated detection of LV endocardial surface from transthoracic near real-time full matrix-array 3D echocardiographic (FM3DE) imaging; (2) evaluate the accuracy of LV volumes obtained with this technique, using cardiac magnetic resonance imaging (MRI) measurements as the reference for comparison; and (3) determine the effects of contrast enhancement on the accuracy of FM3DE measurements. A total of 46 patients underwent 2-dimensional echocardiography, FM3DE, and cardiac MRI. End-diastolic volume, end-systolic volume, and ejection fraction were derived from endocardial borders manually traced from 2-dimensional echocardiographic images and from semiautomatically detected LV cavity from FM3DE data. In 14 patients, FM3DE was also acquired with contrast. All measurements were compared with MRI values using linear regression and Bland-Altman analyses. FM3DE was feasible in 44 of 46 patients with LV volumes < 345 mL. LV volumes and ejection fraction computed from FM3DE resulted in higher levels of agreement with MRI than conventional 2-dimensional echocardiography, with lower interobserver variability. With contrast enhancement, FM3DE significantly underestimated LV volumes and showed increased interobserver variability. Semiautomated LV endocardial surface detection from FM3DE images is feasible and results in fast and accurate assessment of LV function.


Asunto(s)
Ecocardiografía Tridimensional/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Volumen Sistólico , Función Ventricular Izquierda/fisiología , Adulto , Anciano , Medios de Contraste , Ecocardiografía/métodos , Ecocardiografía Tridimensional/instrumentación , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Modelos Lineales , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Sensibilidad y Especificidad
14.
Circulation ; 112(8): 1161-70, 2005 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-16103242

RESUMEN

BACKGROUND: Real-time 3D echocardiographic (RT3DE) data sets contain dynamic volumetric information on cardiac function. However, quantification of left ventricular (LV) function from 3D echocardiographic data is performed on cut-planes extracted from the 3D data sets and thus does not fully exploit the volumetric information. Accordingly, we developed a volumetric analysis technique aimed at quantification of global and regional LV function. METHODS AND RESULTS: RT3DE images obtained in 30 patients (Philips 7500) were analyzed by use of custom software based on the level-set approach for semiautomated detection of LV endocardial surface throughout the cardiac cycle, from which global and regional LV volume (LVV)-time and wall motion (WM)-time curves were obtained. The study design included 3 protocols. In protocol 1, time curves obtained in 16 patients were compared point-by-point with MRI data (linear regression and Bland-Altman analyses). Global LVV correlated highly with MRI (r=0.98; y=0.99x+2.3) with minimal bias (1.4 mL) and narrow limits of agreement (+/-20 mL). WM correlated highly only in basal and midventricular segments (r=0.88; y=0.85x+0.7). In protocol 2, we tested the ability of this technique to differentiate populations with known differences in LV function by studying 9 patients with dilated cardiomyopathy and 9 normal subjects. All calculated indices of global and regional systolic and diastolic LV function were significantly different between the groups. In protocol 3, we tested the feasibility of automated detection of regional WM abnormalities in 11 patients. In each segment, abnormality was detected when regional shortening fraction was below a threshold obtained in normal subjects. The automated detection agreed with expert interpretation of 2D WM in 86% of segments. CONCLUSIONS: Volumetric analysis of RT3DE data is clinically feasible and allows fast, semiautomated, dynamic measurement of LVV and automated detection of regional WM abnormalities.


Asunto(s)
Ecocardiografía Tridimensional/instrumentación , Ecocardiografía Tridimensional/métodos , Cardiopatías/diagnóstico por imagen , Programas Informáticos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda , Adulto , Anciano , Coartación Aórtica/diagnóstico por imagen , Coartación Aórtica/patología , Cardiomiopatía Dilatada/diagnóstico por imagen , Cardiomiopatía Dilatada/patología , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/patología , Diástole , Femenino , Cardiopatías/patología , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/patología , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Sístole , Disfunción Ventricular Izquierda/patología
15.
J Cardiovasc Magn Reson ; 7(3): 595-602, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-15959973

RESUMEN

PURPOSE: The reproducibility of left ventricular (LV) volume and mass measurements based on subjective slice-by-slice tracing of LV borders is affected by image quality, and volume estimates are biased by geometric modeling. The authors developed a technique for volumetric surface detection (VoSD) and quantification of LV volumes and mass without tracing and geometric approximations. The authors hypothesized that this technique is accurate and more reproducible than the conventional methodology. METHODS: Images were obtained in 24 patients in 6 to 10 slices from LV base to apex (GE 1.5 T, FIESTA). Volumetric data were reconstructed, and endocardial and epicardial surfaces were detected using the level set approach. LV volumes were obtained from voxel counts and used to compute ejection fraction (EF) and mass. Conventional measurements (MASS Analysis) were used as a reference to test the accuracy of VoSD technique (linear regression, Bland-Altman). For both techniques, measurements were repeated to compute inter- and intra-observer variability. RESULTS: VoSD values resulted in high correlation with the reference values (EDV: r = 0.98; ESV: r = 0.99; EF: r = 0.91; mass: r = 0.98), with no significant biases (8 ml, 5 ml, 0.2% and -9 g) and narrow limits of agreement (SD: 13 ml, 10 ml, 6% and 9 g). Inter-observer variability of the VoSD technique was lower (range 3 to 5%) than that of the reference technique (5 to 11%; p < 0.05). Intra-observer variability was also lower (1 to 3% vs. 7 to 10%; p < 0.05). CONCLUSION: VoSD technique allows accurate measurements of LV volumes, EF, and mass, which are more reproducible than the conventional methodology.


Asunto(s)
Volumen Cardíaco , Ventrículos Cardíacos/patología , Imagen por Resonancia Cinemagnética/métodos , Modelos Cardiovasculares , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Modelos Lineales , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valores de Referencia , Reproducibilidad de los Resultados , Volumen Sistólico
17.
Circulation ; 110(13): 1814-8, 2004 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-15381653

RESUMEN

BACKGROUND: Left ventricular (LV) mass is an important predictor of morbidity and mortality, especially in patients with systemic hypertension. However, the accuracy of 2D echocardiographic LV mass measurements is limited because acquiring anatomically correct apical views is often difficult. We tested the hypothesis that LV mass could be measured more accurately from real-time 3D (RT3D) data sets, which allow offline selection of nonforeshortened apical views, by comparing 2D and RT3D measurements against cardiac MR (CMR) measurements. METHODS AND RESULTS: Echocardiographic imaging was performed (Philips 7500) in 21 patients referred for CMR imaging (1.5 T, GE). Apical 2- and 4-chamber views and RT3D data sets were acquired and analyzed by 2 independent observers. The RT3D data sets were used to select nonforeshortened apical 2- and 4-chamber views (3DQ-QLAB, Philips). In both 2D and RT3D images, LV long axis was measured; endocardial and epicardial boundaries were traced, and mass was calculated by use of the biplane method of disks. CMR LV mass values were obtained through standard techniques (MASS Analysis, GE). The RT3D data resulted in significantly larger LV long-axis dimensions and measurements of LV mass that correlated with CMR better (r=0.90) than 2D (r=0.79). The 2D technique underestimated LV mass (bias, 39%), whereas RT3D measurements showed only minimal bias (3%). The 95% limits of agreement were significantly wider for 2D (52%) than RT3D (28%). Additionally, the RT3D technique reduced the interobserver variability (37% to 7%) and intraobserver variability (19% to 8%). CONCLUSIONS: RT3D imaging provides the basis for accurate and reliable measurement of LV mass.


Asunto(s)
Ecocardiografía Tridimensional , Ventrículos Cardíacos/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Adulto , Antropometría/métodos , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/patología , Artefactos , Cardiomiopatía Dilatada/diagnóstico por imagen , Cardiomiopatía Dilatada/patología , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/patología , Femenino , Ventrículos Cardíacos/patología , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/patología , Movimiento (Física) , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/patología , Variaciones Dependientes del Observador , Tamaño de los Órganos , Reproducibilidad de los Resultados
18.
J Cardiovasc Magn Reson ; 6(3): 619-25, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15347126

RESUMEN

BACKGROUND: Cardiac magnetic resonance (MR) images are often reviewed by non-cardiologists who are not trained in the interpretation of regional left ventricular (LV) function. We hypothesized that the use of still-frame parametric MR images of wall motion could aid in the assessment of regional LV function. METHODS: Dynamic, electrocardiogram-gated, steady-state free precession (FIESTA) short-axis images were obtained in 6 to 10 slices in 18 consecutive patients. Each loop was used to automatically generate a still-frame image, in which each pixel is assigned a value equal to the amplitude of cyclic variation in local intensity, resulting in higher intensity in pixels that change between blood and tissue during the cardiac cycle. The dynamic images were reviewed by an expert cardiologist who provided gold standard grades for regional wall motion and by four radiologists. Then the radiologists reviewed and graded the same MR images in combination with parametric images. Grades assigned to each segment in the two sessions were compared with the gold standard. RESULTS: According to expert interpretation, 6 patients had normal wall motion, and 12 had wall motion abnormalities. Parametric images showed a bright band in the area spanned by endocardial motion, with reduced brightness and thickness in areas of hypokinesis. The agreement between the radiologists' grades and the gold standard significantly improved by adding parametric images (from 77% to 81%), which also resulted in reduced interobserver variability (from 52% to 33%). CONCLUSIONS: Still-frame parametric images aid in the assessment of regional wall motion by non-cardiologists who are required to interpret cardiac images.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética , Disfunción Ventricular Izquierda/diagnóstico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Médicos , Radiología , Sensibilidad y Especificidad , Volumen Sistólico/fisiología , Disfunción Ventricular Izquierda/fisiopatología
19.
Magn Reson Med ; 52(1): 193-6, 2004 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-15236386

RESUMEN

High spectral and spatial resolution (HiSS) MR data were acquired at 1.5 T using echo-planar spectroscopic imaging from patients with suspicious breast lesions. The water resonances in small voxels are inhomogenously broadened and often have distinct components. Images were calculated with intensity proportional to the Fourier components of the water resonance in each voxel at different offsets from the peak frequency. The results demonstrate that in breast the off-peak Fourier component images of water are qualitatively different from those derived from the peak height of the water resonance. These differences most likely reflect underlying anatomy or physiology. In conventional images, the superposition of the various Fourier components of the water signal may cause loss of detail. The synthesis of water Fourier component images from high spectral and spatial resolution data may provide a new form of contrast, and increase sensitivity to subvoxel physiology and anatomy.


Asunto(s)
Enfermedades de la Mama/diagnóstico , Análisis de Fourier , Imagen por Resonancia Magnética/métodos , Agua Corporal , Femenino , Humanos
20.
Eur Radiol ; 14(5): 915-22, 2004 May.
Artículo en Inglés | MEDLINE | ID: mdl-14610687

RESUMEN

The aim of this study was to show how evidence-based medicine (EBM) techniques can be applied to the appraisal of diagnostic radiology publications. A clinical scenario is described: a gastroenterologist has questioned the diagnostic performance of magnetic resonance cholangiopancreatography (MRCP) in a patient who may have common bile duct (CBD) stones. His opinion was based on an article on MRCP published in "Gut." The principles of EBM are described and then applied to the critical appraisal of this paper. Another paper on the same subject was obtained from the radiology literature and was also critically appraised using explicit EBM criteria. The principles for assessing the validity and strength of both studies are outlined. All statistical parameters were generated quickly using a spreadsheet in Excel format. The results of EBM assessment of both papers are presented. The calculation and application of confidence intervals (CIs) and likelihood ratios (LRs) for both studies are described. These statistical results are applied to individual patient scenarios using graphs of conditional probability (GCP). Basic EBM principles are described and additional points relevant to radiologists discussed. Online resources for EBR practice are identified. The principles of EBM and their application to radiology are discussed. It is emphasized that sensitivity and specificity are point estimates of the "true" characteristics of a test in clinical practice. A spreadsheet can be used to quickly calculate CIs, LRs and GCPs. These give the radiologist a better understanding of the meaning of diagnostic test results in any patient or population of patients.


Asunto(s)
Pruebas Diagnósticas de Rutina/normas , Medicina Basada en la Evidencia/métodos , Publicaciones/normas , Radiología , Intervalos de Confianza , Interpretación Estadística de Datos , Humanos , Funciones de Verosimilitud , Probabilidad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA