Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 145
Filtrar
1.
Thromb Res ; 170: 60-68, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30121005

RESUMEN

BACKGROUND: Tissue factor pathway inhibitor (TFPI) antibodies, which have been reported in patients with antiphospholipid syndrome (APS), may impair TFPI activity and contribute to hypercoagulability, but their role in APS and in thrombosis remains undefined. OBJECTIVE/METHODS: We assessed the presence and avidity of TFPI IgG antibodies, associations with protein C IgG antibodies and associations with clinical disease severity, in 50 patients with thrombotic APS and 50 thrombotic control patients, on long term anticoagulation with warfarin. RESULTS: Thrombotic APS patients had a significantly higher prevalence of TFPI IgG antibodies (40%; 20/50) compared to thrombotic controls (18%; 9/50). TFPI antibodies were predominantly high avidity in APS (50%, 10/20 of positive patients) and strongly associated with a severe thrombotic phenotype (venous and arterial thromboembolism or recurrent thromboembolic episodes despite therapeutic anticoagulation) (odds ratio (OR): 12.0, 95%CI: 2.2-66.1, p = 0.004), while thrombotic control patients mainly showed low avidity antibodies (78%, 7/9 of positive patients). Coexistence of TFPI and protein C IgG antibodies, regardless of their avidity, was strongly associated with a more severe thrombotic phenotype in APS patients (OR: 20.2, 95%CI: 2.0-47.0, p < 0.0001) and also in thrombotic controls (OR: 75.0, 95%CI 1.2-195, p = 0.02). CONCLUSIONS: Coexistent TFPI and protein C IgG antibodies, irrespective of their avidity, may be a useful marker for a severe thrombotic phenotype in thrombotic patients. This suggests a possibly pathophysiological relationship between the two antibodies, predisposing to thrombosis with a possibly more general role in the development of thrombotic complications.


Asunto(s)
Síndrome Antifosfolípido/inmunología , Pruebas de Coagulación Sanguínea/métodos , Lipoproteínas/efectos adversos , Proteína C/efectos adversos , Estudios Transversales , Femenino , Humanos , Lipoproteínas/metabolismo , Masculino , Persona de Mediana Edad , Fenotipo , Proteína C/metabolismo
2.
Int J Lab Hematol ; 39(5): 532-538, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28603894

RESUMEN

INTRODUCTION: A new prothrombin time reagent (Revohem™ PT) based on recombinant human tissue factor produced by the silkworm-baculovirus expression system was tested. The aim of this study was to compare the performance of the new PT reagent with two widely used routine PT reagents. METHODS: All testing was performed on a Sysmex CS-5100 coagulometer. Revohem™ PT was tested for imprecision and stability using normal and abnormal lyophilized commercial control plasmas. Comparability was assessed with two widely used reagents: one containing recombinant human tissue factor (Reagent A) and the other a human placental thromboplastin (Reagent B) using a wide range of normal and abnormal plasmas and analyser-specific ISI values. RESULTS: Excellent between-day imprecision was obtained for Revohem™ PT (CV <1.0%) and acceptable open-vial on-board stability over 7 days. There was good agreement between methods in samples from patients with liver disease and patients receiving warfarin and no significant differences between methods with increasing INR values. Both recombinant reagents suffered less interference from lupus anticoagulant than the placental thromboplastin. Revohem™ PT had similar sensitivity to reagents A and B for FII, V, VII and X deficiency and demonstrated dose responsiveness to dabigatran, apixaban and rivaroxaban with steeper response curves than the comparison reagents. CONCLUSION: Revohem™ PT showed comparable or improved performance relative to two widely used reagents and is suitable for use in warfarin control, detection of inherited factor II, V, VII and X deficiency and assessment of liver disease coagulopathy.


Asunto(s)
Tiempo de Protrombina/métodos , Tiempo de Protrombina/normas , Juego de Reactivos para Diagnóstico/normas , Humanos , Relación Normalizada Internacional , Protrombina , Tiempo de Protrombina/instrumentación , Proteínas Recombinantes , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Factores de Tiempo
3.
J Thromb Haemost ; 14(11): 2177-2186, 2016 11.
Artículo en Inglés | MEDLINE | ID: mdl-27541499

RESUMEN

Essentials Complement activation has a pathogenic role in thrombotic antiphospholipid syndrome (APS). Coagulation proteases such as factor Xa can activate complement proteins. Complement activation markers were elevated in anticoagulated thrombotic APS patients. Complement activation decreased in APS patients switching from warfarin to rivaroxaban. SUMMARY: Background Complement activation may play a major role in the pathogenesis of thrombotic antiphospholipid syndrome (APS). Coagulation proteases such as factor Xa can activate complement proteins. Aims To establish whether rivaroxaban, a direct factor Xa inhibitor, limits complement activation compared with warfarin in APS patients with previous venous thromboembolism (VTE). Methods A total of 111 APS patients with previous VTE, on warfarin target INR 2.5, had blood samples taken at baseline and at day 42 after randomization in the RAPS (Rivaroxaban in Antiphospholipid Syndrome) trial. Fifty-six patients remained on warfarin and 55 switched to rivaroxaban. Fifty-five normal controls (NC) were also studied. Markers of complement activation (C3a, C5a, terminal complement complex [SC5b-9] and Bb fragment) were assessed. Results APS patients had significantly higher complement activation markers compared with NC at both time-points irrespective of the anticoagulant. There were no differences between the two patient groups at baseline, or patients remaining on warfarin at day 42. In 55 patients randomized to rivaroxaban, C3a, C5a and SC5b-9 were lower at day 42 (median (ng mL-1 ) [confidence interval] 64 [29-125] vs. 83 [35-147], 9 [2-15] vs. 12 [4-18] and 171 [56-245] vs. 201 [66-350], respectively) but levels of Bb fragment were unchanged. There were no correlations between rivaroxaban levels and complement activation markers. Conclusions APS patients with previous VTE on warfarin exhibit increased complement activation, which is likely to occur via the classical pathway and is decreased by rivaroxaban administration. Rivaroxaban may therefore potentially provide an additional benefit to its anticoagulant effect in this patient group by limiting complement activation.


Asunto(s)
Anticoagulantes/uso terapéutico , Síndrome Antifosfolípido/tratamiento farmacológico , Coagulación Sanguínea/efectos de los fármacos , Inhibidores del Factor Xa/uso terapéutico , Rivaroxabán/uso terapéutico , Tromboembolia Venosa/tratamiento farmacológico , Warfarina/uso terapéutico , Adulto , Síndrome Antifosfolípido/sangre , Síndrome Antifosfolípido/complicaciones , Activación de Complemento , Factor Xa/química , Femenino , Humanos , Inflamación/tratamiento farmacológico , Relación Normalizada Internacional , Masculino , Persona de Mediana Edad , Trombosis/sangre , Tromboembolia Venosa/sangre , Tromboembolia Venosa/complicaciones
4.
J Thromb Haemost ; 13(7): 1264-73, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25850997

RESUMEN

INTRODUCTION: Rivaroxaban can affect lupus anticoagulant (LA) testing and antiphospholipid antibodies (aPL) may interfere with the anticoagulant action of rivaroxaban. AIMS: To establish the influence of rivaroxaban on LA detection and of aPL on the anticoagulant action of rivaroxaban. METHODS: Rivaroxaban and 52 IgG preparations (20 LA+ve, 12 LA-ve thrombotic antiphospholipid syndrome [APS] patients, and 20 normal controls [NC]) were spiked into pooled normal plasma (PNP) for relevant studies. LA detection was also studied in APS patients receiving rivaroxaban 20 mg once daily. RESULTS: In vitro spiking of samples with rivaroxaban showed no false positive LA with Textarin time, Taipan venom time/Ecarin clotting time (TVT/ECT), dilute prothrombin time (dPT) and in-house dilute Russell's viper venom time (DRVVT), but false positives in the majority of NC and LA negative IgG with two commercial DRVVT reagents at 250 ng/mL but not 50 ng/mL rivaroxaban. Ex vivo studies: six LA+ve patients on rivaroxaban remained LA positive with TVT/ECT and DRVVT at peak (162-278 ng/mL) and trough (30-85 ng/mL) rivaroxaban levels. Six LA-ve patients became (apparently) LA+ve with two DRVVT reagents (test/confirm ratio median [confidence interval], 1.6 [1.3-1.8], 1.6 [1.4-1.9]) but not with TVT/ECT at peak rivaroxaban levels, and remained LA-ve with both DRVVT reagents and TVT/ECT at trough levels. aPL positive IgG spiking of PNP had no effect on rivaroxaban's anticoagulant action on thrombin generation or rivaroxaban anti-Xa levels. CONCLUSIONS: The TVT/ECT ratio and Textarin time were not affected even at peak rivaroxaban levels, enabling detection of LA ex vivo. aPL had no effects on rivaroxaban's anticoagulant action in vitro.


Asunto(s)
Anticuerpos Antifosfolípidos/sangre , Síndrome Antifosfolípido/tratamiento farmacológico , Coagulación Sanguínea/efectos de los fármacos , Inhibidores del Factor Xa/uso terapéutico , Inmunoglobulina G/sangre , Rivaroxabán/uso terapéutico , Trombosis/tratamiento farmacológico , Síndrome Antifosfolípido/sangre , Síndrome Antifosfolípido/diagnóstico , Biomarcadores/sangre , Pruebas de Coagulación Sanguínea , Estudios de Casos y Controles , Inhibidores del Factor Xa/efectos adversos , Reacciones Falso Positivas , Humanos , Inhibidor de Coagulación del Lupus/sangre , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Rivaroxabán/efectos adversos , Trombosis/sangre , Trombosis/diagnóstico , Resultado del Tratamiento
5.
Thromb Res ; 135(2): 388-93, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25555316

RESUMEN

INTRODUCTION: Rivaroxaban is non-inferior to warfarin for the treatment of venous thromboembolism, with regard to clinical efficacy and safety. The ex-vivo effects of warfarin versus therapeutic dose rivaroxaban on in-vivo markers of coagulation activation and thrombin generation remain undefined. The aim of this study was to compare the effects of warfarin and therapeutic dose rivaroxaban on ex-vivo thrombin generation (TG), and the in-vivo markers of coagulation activation, prothrombin fragment 1.2 (F1.2), thrombin-antithrombin complex (TAT), and D-dimer. METHODS: Eighty-five patients with venous thromboembolism were studied, 45 on warfarin, target INR 2.5 and 40 on rivaroxaban 20mg once daily. RESULTS: Anticoagulation was in therapeutic range in 71% (32/45) warfarin and 65% (26/40) rivaroxaban treated patients. 8 patients on warfarin and 9 patients on rivaroxaban had subtherapeutic INR and rivaroxaban levels respectively. Both rivaroxaban and warfarin reduced endogenous thrombin potential (ETP) and peak thrombin, and prolonged lag time and time to peak, compared to normal controls (p<0.0001). The lag time and time to peak TG were longer, and peak thrombin was lower in patients receiving rivaroxaban (p<0.0001) compared with warfarin, although warfarin-treated patients had lower ETP (p=0.0008). In-vivo coagulation activation markers were within the normal ranges in all rivaroxaban-treated patients (including those with levels considered to be subtherapeutic) and in 37/45 warfarin-treated patients who had an INR≥2.0. The warfarin-treated patients with subtherapeutic INRs exhibited slightly raised F1.2 and/or TAT. CONCLUSION: In conclusion, both rivaroxaban and warfarin provided effective anticoagulation, as assessed by inhibition of TG and makers of in-vivo coagulation activation.


Asunto(s)
Anticoagulantes/uso terapéutico , Inhibidores del Factor Xa/uso terapéutico , Relación Normalizada Internacional/métodos , Morfolinas/uso terapéutico , Tiofenos/uso terapéutico , Tromboembolia Venosa/tratamiento farmacológico , Adulto , Anciano , Coagulación Sanguínea/efectos de los fármacos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Rivaroxabán , Warfarina/uso terapéutico
6.
J Thromb Haemost ; 12(11): 1801-9, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25196808

RESUMEN

BACKGROUND: Antiphospholipid antibodies may interfere with the anticoagulant activity of activated protein C (APC) to induce acquired APC resistance (APCr). AIMS: To investigate the frequency and characteristics of APCr by using recombinant human APC (rhAPC) and endogenous protein C activation in antiphospholipid syndrome (APS). METHODS: APCr was assessed in APS and non-APS venous thromboembolism (VTE) patients on warfarin and normal controls with rhAPC or Protac by thrombin generation. IgG anti-protein C and anti-protein S antibodies and avidity were assessed by ELISA. RESULTS: APS patients showed greater resistance to both rhAPC and Protac than non-APS patients and normal controls (median normalized endogenous thrombin potential inhibition): APS patients with rhAPC, 81.3% (95% confidence interval [CI] 75.2-88.3%; non-APS patients with rhAPC, 97.7% (95% CI 93.6-101.8%; APS patients with Protac, 66.0% (95% CI 59.5-72.6%); and non-APS patients with Protac, 80.7 (95% CI 74.2-87.2%). APS patients also had a higher frequency and higher levels of anti-protein C antibodies, with 60% (15/25) high-avidity antibodies. High-avidity anti-protein C antibodies were associated with greater APCr and with a severe thrombotic phenotype (defined as the development of recurrent VTE while patients were receiving therapeutic anticoagulation or both venous and arterial thrombosis). Twelve of 15 (80%) patients with high-avidity anti-protein C antibodies were classified as APS category I. CONCLUSION: Thrombotic APS patients showed greater APCr to both rhAPC and activation of endogenous protein C by Protac. High-avidity anti-protein C antibodies, associated with greater APCr, may provide a marker for a severe thrombotic phenotype in APS. However, in patients with category I APS, it remains to be established whether anti-protein C or anti-ß2 -glycoprotein I antibodies are responsible for APCr.


Asunto(s)
Resistencia a la Proteína C Activada/inmunología , Anticuerpos Antifosfolípidos/sangre , Síndrome Antifosfolípido/complicaciones , Proteína C/inmunología , Tromboembolia Venosa/inmunología , Resistencia a la Proteína C Activada/sangre , Resistencia a la Proteína C Activada/diagnóstico , Resistencia a la Proteína C Activada/tratamiento farmacológico , Adulto , Anciano , Anticoagulantes/uso terapéutico , Síndrome Antifosfolípido/sangre , Síndrome Antifosfolípido/diagnóstico , Síndrome Antifosfolípido/tratamiento farmacológico , Síndrome Antifosfolípido/inmunología , Biomarcadores/sangre , Pruebas de Coagulación Sanguínea , Estudios de Casos y Controles , Estudios Transversales , Ensayo de Inmunoadsorción Enzimática , Femenino , Fibrinolíticos/uso terapéutico , Humanos , Péptidos y Proteínas de Señalización Intercelular , Masculino , Persona de Mediana Edad , Péptidos/uso terapéutico , Fenotipo , Proteína C/uso terapéutico , Proteínas Recombinantes/uso terapéutico , Índice de Severidad de la Enfermedad , Tromboembolia Venosa/sangre , Tromboembolia Venosa/diagnóstico , Tromboembolia Venosa/prevención & control , Warfarina/uso terapéutico
8.
Haemophilia ; 20(2): e144-8, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24329777

RESUMEN

Pregnancy is associated with significant haemostatic changes, with a progressive rise in most clotting factors. There is limited data on the changes of factor XIII (FXIII) level during pregnancy. This study assesses changes in FXIII activity during normal pregnancy and establish FXIII reference range during each trimester of pregnancy and immediate postnatal period. This is a cross sectional study of 376 women with normal uneventful pregnancies. Plasma FXIII activity was measured during first (weeks 0-12, n = 116), second (weeks 13-28, n = 132), third trimester (weeks 29-42, n = 128) and postnatal (day 0-3; n = 30). Samples were also collected from non-pregnant women (n = 25) as a control group. FXIII was assayed on CS-5100 analyser using chromogenic reagent. The mean ± SD FXIII activity was 112 ± 29 IU dL(-1) during first trimester, 96 ± 26 IU dL(-1) during second trimester, 83 ± 21 IU dL(-1) during third trimester, 90 ± 19 IU dL(-1) during postnatal period, and 113 ± 26 IU dL(-1) in the control. The reference range was calculated during the first (55-169 IU dL(-1)), second (45-147 IU dL(-1)), third trimester (42-125 IU dL(-1)) and postnatal period (61-137 IU dL(-1)). There was a significant reduction in the mean FXIII activity during the second and third trimester compared to the first trimester and control group (P < 0.0001). During the immediate postnatal period, the mean FXIII activity was not statistically different compared to the third and second trimester levels but was significantly lower compared to the first trimester (P < 0.0001) level and the control group (P = 0.0002). This study establishes the reference range for FXIII activity during the three trimesters of normal pregnancy and immediate postnatal period. Women have a significantly decreased level of FXIII activity during a normal uneventful pregnancy.


Asunto(s)
Factor XIII/metabolismo , Trimestres del Embarazo/sangre , Adulto , Estudios Transversales , Femenino , Humanos , Persona de Mediana Edad , Embarazo , Resultado del Embarazo , Valores de Referencia , Factores de Riesgo , Adulto Joven
9.
Int J Lab Hematol ; 36(4): 431-8, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24237750

RESUMEN

INTRODUCTION: The investigation of platelet function by aggregometry requires specialist equipment and is labour intensive. We have developed an automated platelet aggregation method on a routine coagulation analyser. METHODS: We used a CS-2000i (Sysmex) with prototype software to perform aggregation in platelet-rich plasma (PRP), using the following agonists: ADP (0.5-10 µm), epinephrine (0.5-10 µm), collagen (0.5-10 mg/µL), ristocetin (0.75-1.25 mg/mL) and arachidonic acid (0.12-1.0 mm). Platelet agonists were from Hyphen Biomed, and an AggRAM aggregometer (Helena Biosciences) was used as the reference instrument. RESULTS: CS-2000i reaction cuvette stirrer speed was found to influence reaction sensitivity and was optimized to 800 rpm. There were no clinically significant changes in aggregation response when the PRP platelet count was 150-480 x 10(9) /L, but below this there were changes in the maximum amplitude (MA) and slope (rate). Dose response with each of the agonists was comparable between CS-2000i and an AggRAM aggregometer and normal subjects receiving antiplatelet drugs. Aggregation imprecision was similar on both the CS-2000i and AggRAM systems, with a cv for 2-5 µm ADP MA and slope varying between 3-12%. CONCLUSION: Our preliminary studies indicated that optimal sensitivity using the CS-2000i was obtained with a reaction cuvette stirrer speed of 800 rpm and a PRP platelet count of 200-300 x 10(9) /L; aggregation with a PRP count <100 x 10(9) /L showed poor sensitivity. Imprecision and detection of antiplatelet drug effects was similar between the CS-2000i and AggRAM. These data demonstrate that CS-2000i is comparable to a stand-alone aggregometer, although CS-2000i has the advantages of walk-away technology and also required a smaller sample volume than the AggRAM (44% less).


Asunto(s)
Automatización de Laboratorios/normas , Plaquetas/efectos de los fármacos , Agregación Plaquetaria/efectos de los fármacos , Adenosina Difosfato/farmacología , Automatización de Laboratorios/instrumentación , Células Cultivadas , Colágeno/farmacología , Epinefrina/farmacología , Humanos , Pruebas de Función Plaquetaria , Ristocetina/farmacología , Sensibilidad y Especificidad
10.
Int J Lab Hematol ; 35(6): 652-7, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23718922

RESUMEN

INTRODUCTION: The Clinical and Laboratory Standards Institute (CLSI) has produced a guideline detailing how to determine the activated partial thromboplastin time's (APTT) sensitivity to clotting factor deficiencies, by mixing normal and deficient plasmas. Using the guideline, we determined the factor sensitivity of two APTT reagents. METHODS: APTTs were performed using Actin FS and Actin FSL on a Sysmex CS-5100 analyser. The quality of factor-deficient and reference plasmas from three commercial sources was assessed by assaying each of the clotting factors within the plasmas and by performing thrombin generation tests (TGT). RESULTS: Testing samples from 50 normal healthy subjects gave a two-standard deviation range of 21.8-29.2 s for Actin FS and 23.5-29.3 s for Actin FSL. The upper limits of these ranges were subsequently used to determine APTT factor sensitivity. Assay of factor levels within the deficient plasmas demonstrated that they were specifically deficient in a single factor, with most other factors in the range 50-150 iu/dL (Technoclone factor VII-deficient plasma has 26 iu/dL factor IX). APTTs performed on mixtures of normal and deficient plasmas gave diverse sensitivity to factor deficiencies dependent on the sources of deficient plasma. TGT studies on the deficient plasmas revealed that the potential to generate thrombin was not solely associated with the levels of their component clotting factors. CONCLUSION: Determination of APTT factor sensitivity in accordance with the CLSI guideline can give inconsistent and misleading results.


Asunto(s)
Tiempo de Tromboplastina Parcial/normas , Factores de Coagulación Sanguínea/metabolismo , Pruebas de Coagulación Sanguínea/métodos , Pruebas de Coagulación Sanguínea/normas , Humanos , Tiempo de Tromboplastina Parcial/métodos , Guías de Práctica Clínica como Asunto , Juego de Reactivos para Diagnóstico , Valores de Referencia , Sensibilidad y Especificidad
11.
Haemophilia ; 19(2): 338-42, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23205618

RESUMEN

The ristocetin cofactor assay (VWF:RCo) is the reference method for assessing von Willebrand factor (VWF) activity in the diagnosis of von Willebrand's Disease (VWD). However, the assay suffers from poor reproducibility and sensitivity at low levels of VWF and is labour intensive. We have undertaken an evaluation of a new immunoturbidimetric VWF activity (VWF:Ac) assay (INNOVANCE(®) VWF Ac. Siemens Healthcare Diagnostics, Marburg, Germany) relative to an established platelet-based VWF:RCo method. Samples from 50 healthy normal subjects, 80 patients with VWD and 50 samples that exhibited 'HIL' (i.e. Haemolysis, Icterus or Lipaemia) were studied. VWF:Ac, VWF:RCo and VWF:Ag were performed on a CS-analyser (Sysmex UK Ltd, Milton Keynes, UK), all reagents were from Siemens Healthcare Diagnostics. The VWF:Ac assay, gave low intra- and inter-assay imprecision (over a 31-day period, n = 200 replicate readings) using commercial normal (Mean 96.2 IU dL(-1), CV < 3.0%) and pathological (Mean 36.1 IU dL(-1), CV < 3.5%) control plasmas. The normal and clinical samples exhibited good correlation between VWF:RCo (range 3-753 IU dL(-1)) and VWF:Ac (rs = 0.97, P < 0.0001), with a mean bias of 5.6 IU dL(-1). Ratios of VWF:Ac and VWF:RCo to VWF:Ag in the VWD samples were comparable, although VWF:Ac had a superior lower level of detection to that of VWF:RCo (3% and 5% respectively). A subset (n = 97) of VWD and HIL samples were analysed for VWF:Ac at two different dilutions to assess the effect on relative potency, no significant difference was observed (P = 0.111). The INNOVANCE(®) VWF Ac assay was shown to be reliable and precise.


Asunto(s)
Ensayo de Inmunoadsorción Enzimática/métodos , Enfermedades de von Willebrand/diagnóstico , Factor de von Willebrand/análisis , Anticuerpos Monoclonales , Humanos , Receptores de GABA-B/metabolismo , Reproducibilidad de los Resultados
12.
J Thromb Haemost ; 10(9): 1792-801, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22783805

RESUMEN

BACKGROUND: ADAMTS13 mutations play a role in thrombotic thrombocytopenic purpura (TTP) pathogenesis. OBJECTIVES: To establish a phenotype-genotype correlation in a cohort of congenital TTP patients. PATIENTS/METHODS: Clinical history and ADAMTS13 activity, antigen and anti-ADAMTS13 antibody assays were used to diagnose congenital TTP, and DNA sequencing and in vitro expression were performed to identify the functional effects of the ADAMTS13 mutations responsible. RESULTS: Seventeen (11 novel) ADAMTS13 mutations were identified in 17 congenital TTP patients. All had severely reduced ADAMTS13 activity and antigen levels at presentation. Six patients with pregnancy-associated TTP and six patients with childhood TTP were homozygous or compound heterozygous for ADAMTS13 mutations located in the metalloprotease (MP), cysteine-rich, spacer and/or distal thrombospondin type 1 domains. The adults had TTP precipitated by pregnancy, and had overall higher antigen levels (median, 30 ng mL(-1) ; range, < 10-57 ng mL(-1) ) than the children (median, 14 ng mL(-1) ; range, < 10-40 ng mL(-1)). Presentation in the neonatal period was associated with more intensive treatment requirements. The two neonates with the most severe phenotype had mutations in the first thrombospondin type 1 motif of ADAMTS13 (p.R398C, p.R409W, and p.Q436H). Using transfected HEK293T cells, we have shown that p.R398C and p.R409W block ADAMTS13 secretion, whereas p.Q436H allows secretion at reduced levels. CONCLUSIONS: This study confirms the heterogeneity of ADAMTS13 defects and an association between ADAMTS13 genotypes and TTP phenotype.


Asunto(s)
Proteínas ADAM/genética , Mutación , Púrpura Trombocitopénica Trombótica/genética , Proteína ADAMTS13 , Adulto , Western Blotting , Estudios de Casos y Controles , Niño , Preescolar , Femenino , Genotipo , Humanos , Lactante , Recién Nacido , Masculino , Fenotipo , Embarazo , Reino Unido
13.
Am J Transplant ; 12(6): 1632-6, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22420623

RESUMEN

We report here a young female who underwent a successful deceased donor liver transplant for hepatic vein thrombosis. Five years after transplantation she developed postpartum atypical hemolytic uremic syndrome (aHUS). She did not recover renal function. Mutation screening of complement genes in her DNA did not show any abnormality. Mutation screening of DNA available from the donor showed a nonsense CFH mutation leading to factor H deficiency. Genotyping of the patient showed that she was homozygous for an aHUS CD46 at-risk haplotype. In this individual, the development of aHUS has been facilitated by the combination of a trigger (pregnancy), an acquired rare genetic variant (CFH mutation) and a common susceptibility factor (CD46 haplotype).


Asunto(s)
Factor H de Complemento/genética , Trasplante de Hígado , Periodo Posparto , Adulto , Síndrome de Budd-Chiari/cirugía , Femenino , Homocigoto , Humanos
14.
Thromb Res ; 129(4): 447-52, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21849206

RESUMEN

INTRODUCTION: A persistently elevated level of factor VIII (FVIII) is an independent risk factor for venous thromboembolism (VTE). Although the pathophysiology of VTE is unclear, the involvement of thrombin generation (TG) has been postulated. Consequently this study was designed to (i) investigate the relationships between FVIII, Thrombin generation test (TGT) parameters and D-dimer in VTE patients, (ii) determine whether elevated levels of FVIII and increased TG in these patients are transient or sustained. PATIENTS AND METHODS: After an initial period of anticoagulation had been completed 91 VTE patients and 52 healthy controls were recruited. FVIII levels were determined by one-stage clotting (FVIII:C) and chromogenic (FVIII:Ch) assays. The potential to generate thrombin was measured using the Calibrated Automated Thrombogram (CAT) and D-Dimer was by immuno-turbidometric assay. RESULTS: Patients' FVIII:C levels and FVIII:Ch, exhibited good agreement (rs=0.94; p<0.0001), although FVIII:C exhibited a mean bias of -6%. FVIII:Ch show a significant correlation with TGT Peak Thrombin (rs=0.30; p=0.004) and Peak Thrombin was found to be significantly higher (p=0.04) in patients with FVIII>200 iu/dL. Furthermore elevated levels of FVIII and increased thrombin generation parameters appeared to be consistent over time. CONCLUSION: Our data suggests that high FVIII leading to increased TG confers a significant risk of recurrent VTE and therefore we speculate that these patients may benefit from prolonged anticoagulation therapy.


Asunto(s)
Factor VIII/análisis , Trombina/análisis , Tromboembolia Venosa/sangre , Tromboembolia Venosa/epidemiología , Adulto , Anciano , Anticoagulantes/uso terapéutico , Biomarcadores/sangre , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Estudios Prospectivos , Medición de Riesgo , Factores de Riesgo , Reino Unido/epidemiología , Tromboembolia Venosa/tratamiento farmacológico , Adulto Joven
15.
Haemophilia ; 17(2): 252-6, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21070498

RESUMEN

von Willebrand's disease (VWD) is regarded as the most common congenital bleeding disorder, and although not available in all laboratories von Willebrand factor (VWF) activity is most frequently assessed as ristocetin cofactor (VWF:RCo). This test can be technically challenging, is subject to poor sensitivity (∼20 IU dL(-1) VWF:RCo) and has a high degree of inter- and intra-assay imprecision [coefficient of variation (cv) > 25%]. We studied an automated assay using a combined fixed platelet/ristocetin reagent (BC von Willebrand reagent, Siemens Healthcare Diagnostics) on the CS-2000i analyser (Sysmex UK Ltd). Initially inter- and intra-assay imprecision was assessed. The automated method showed good day-to-day reproducibility and linearity of standard curves. This technique, also gave low intra- and inter-assay imprecision using commercial normal (cv < 4.5%) and pathological (cv < 8.1%) control plasmas. We then compared automated technique results from 30 healthy normal subjects and 39 VWD patients to those obtained using standard aggregometry (Bio/Data, PAP4) with lyophilised fixed platelets (Helena BioSciences) and ristocetin (American Biochemical and Pharmaceutical Ltd). The automated method had a sensitivity limit of approximately 10 IU dL(-1) vs. 20 IU dL(-1) for aggregometry. Samples giving results within the aggregometry measurable range (n = 50) exhibited good correlation with the automated technique (median 70 IU dL(-1), range 7-184 IU dL(-1); and 64 IU dL(-1), 6-138 IU dL(-1) respectively; R(2) = 0.85). We subsequently compared 3 different batches of BC von Willebrand reagent, using a second group of normal subjects and VWD patients (n = 35, 55-139 IU dL(-1) and n = 30, <10-50 IU dL(-1)). The CS-2000i results exhibited no clinically significant variation between batches (mean cv = 7%). The automated VWF:RCo assay offers a more sensitive, reproducible, robust and less laborious alternative to standard aggregometry.


Asunto(s)
Pruebas de Coagulación Sanguínea/métodos , Enfermedades de von Willebrand/diagnóstico , Factor de von Willebrand/análisis , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Enfermedades de von Willebrand/sangre
16.
Vox Sang ; 99(3): 232-8, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20840338

RESUMEN

BACKGROUND: Octapharma PPGmbH has recently modified its manufacturing process for solvent/detergent-treated plasma to incorporate a prion reduction step, in which a 3 log reduction has been demonstrated. The current study was undertaken to assess the impact of this procedure on haemostatic variables in the new product OctaplasLG in comparison with standard Octaplas. METHODS: Production batches of standard Octaplas (n=4) and OctaplasLG (n=16) were assessed for levels of coagulation factors, physiological protease inhibitors, markers of activation and procoagulant microparticles. Global haemostasis was assessed by a thrombin generation test (TGT) and rotational thromboelastometry (ROTEM). RESULTS: Mean levels of factors: II, V, VII, IX, X, XI, XII and XIII, VWF:Ag, antithrombin, protein C and free protein S were all >75 u/dl. ADAMTS-13 activity levels were normal. Factor VIII and VWF:RCo were >55 u/dl. TGT and ROTEM were similar in both preparations, and microparticles were present at negligible levels. Two units of OctaplasLG had slightly elevated levels of Prothrombin Fragments 1+2, but D-Dimer and thrombin-antithrombin complexes were normal in all batches. CONCLUSION: These studies indicate that the affinity chromatography procedure used in OctaplasLG does not appear to adversely affect the proven haemostatic quality of Octaplas, while offering a selective reduction in the concentration of pathological prion proteins.


Asunto(s)
Proteínas Sanguíneas/análisis , Hemostáticos/análisis , Plasma/química , Priones , Cromatografía de Afinidad/métodos , Humanos
17.
J Thromb Haemost ; 8(11): 2478-82, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20727071

RESUMEN

BACKGROUND: The clot solubility test is the most widely used method for detection of factor (F)XIII deficiency. However, it will only detect severe deficiencies; consequently mild deficiencies and heterozygous states are probably under diagnosed. OBJECTIVE: As an alternative first-line screening test, we assessed an automated quantitative ammonia release assay (QARA). PATIENTS/METHODS: Inter-assay imprecision was evaluated with commercial normal and pathological control plasmas (10 replicates on each of 5 days). Using the QARA and other commercial assays a comparative assessment of congenital (FXIII range < 1-70 u dL(-1), n = 9) and acquired (n = 43) deficiencies was made. We also investigated the prevalence of acquired deficiencies in hospitalized patients using residual samples from adult patients (n = 1004) and from a paediatric intensive care unit (ICU, n = 56). RESULTS: Assay imprecision was acceptably low (normal control: mean 86.6 u dL(-1); cv = 2.0%; pathological control: mean 27.5 u dL(-1); cv = 3.8%). Using an iodoacetamide blanking procedure, the QARA results (FXIII range < 1-70 u dL(-1)) exhibited close agreement with those from an immuno-turbidometric FXIII A-subunit (FXIII-A) method. There was also good correlation (R(2) ≥ 0.89) between the QARA (range 20-180 u dL(-1)), a second chromogenic assay, the FXIII-A and FXIII A+B-subunit ELISA. We found that 21% of samples from adult patients had FXIII levels < 70 u dL(-1) (mean normal ± 2 SD 73-161 u dL(-1)) with 6% < 50 u dL(-1). Within the paediatric ICU samples, 52% were < 70 u dL(-1), with 21% < 50 u dL(-1). CONCLUSIONS: Our data demonstrates that the automated assay is sensitive, highly reproducible and the results from clinical samples suggest that acquired FXIII deficiency is a relatively common phenomenon in hospital patients after surgery and in ICU.


Asunto(s)
Química Clínica/métodos , Deficiencia del Factor XIII/sangre , Deficiencia del Factor XIII/diagnóstico , Factor XIII/análisis , Adulto , Automatización , Niño , Estudios de Cohortes , Heterocigoto , Humanos , Sistema Inmunológico , Unidades de Cuidados Intensivos , Nefelometría y Turbidimetría/métodos , Prevalencia , Reproducibilidad de los Resultados , Cicatrización de Heridas
18.
J Thromb Haemost ; 8(6): 1201-8, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-20175870

RESUMEN

BACKGROUND: Increasingly, patients with acute, idiopathic, antibody mediated thrombotic thrombocytopenic purpura (TTP) are being treated with rituximab to achieve a durable remission, however, there is the potential that it is removed by plasma exchange (PEX). OBJECTIVES: To look at the pharmacokinetics and pharmacodynamics of rituximab in patients with acute idiopathic TTP undergoing PEX. PATIENTS AND METHODS: Patients who received rituximab for acute idiopathic TTP (group 1, n = 30) and a control group (group 2, n = 3) of TTP patients in remission receiving rituximab electively as maintenance were included. Rituximab levels were measured before/after each infusion, before/after PEX and in follow-up. ADAMTS-13 activity, anti-ADAMTS-13 IgG and CD19% were measured to assess response. RESULTS: The median number of PEX to remission after rituximab was 10 (range 4-25). In group 1 there was no significant incremental rise in the peak serum rituximab level until dose 4. Trough levels were lower in patients who had had PEX since their last rituximab infusion. In the control group, there was an incremental rise in the peak serum rituximab level and all patients had detectable trough levels. The median fall in rituximab per PEX was 65%. All patients achieved CD19 < 1%. In group 1, the median time to undetectable rituximab was 5 months (range 0-12 months) and to B cell return was 7 months (range 3-24 months). ADAMTS-13 increased and anti-ADAMTS-13 fell after therapy. There were three deaths and two relapses in group 1. Relapse was not temporally related to B cell return.


Asunto(s)
Anticuerpos Monoclonales de Origen Murino/farmacocinética , Púrpura Trombocitopénica Trombótica/terapia , Enfermedad Aguda , Adolescente , Adulto , Anciano , Anticuerpos Monoclonales de Origen Murino/uso terapéutico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Rituximab , Adulto Joven
19.
Vox Sang ; 96(3): 206-12, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19175566

RESUMEN

BACKGROUND: We have previously shown that fresh-frozen plasma (FFP) contains red blood cell-derived procoagulant microparticles (MPs) that are removable by 0.2 microm filtration. Given the limitations of current methods for accurately sizing MPs, we have applied the novel approach of dynamic light scattering (DLS) to characterize the size distributions of these MPs within FFP. METHODS: Fresh-frozen plasma was prepared from blood Group A and O donations (n = 10 of each) after an overnight hold of whole blood at 4 degrees C. On the day of analysis, plasma was thawed to 37 degrees C and daughter aliquots were studied pre- and post-filtration (0.2 microm filtration device, Ceveron MFU-500, Technoclone). MP size and dispersity was assessed using a Zetasizer Nano S (Malvern Instruments Ltd), which employs a 173 degrees backscatter detector and an N5 Submicron Particle Size Analyser (Beckman Coulter) using multi-angle measurements (30.1 degrees , 62.6 degrees and 90 degrees ). The analysers presented MP size distribution graphically as intensity plots, mean size, standard deviation and polydispersity index. RESULTS: Of the instruments used, only the N5 utilizing a 30.1 degrees angle of measurement could detect MPs of the expected size distribution and demonstrate their removal by filtration. MPs (range of mean particle diameters: pre, 101-464 nm; post, 21-182 nm filtration) were significantly smaller post-filtration (P < 0.0001), but polydispersity index (median: pre, 0.746, post, 0.769) exhibited no significant change. There was no significant difference between the size of MPs from blood Group O (pre, 247 nm) and Group A (pre, 289 nm) samples (P = 0.44). CONCLUSION: Our data demonstrates that DLS offers a novel approach to assessing MP size and distribution, a technique that could be easily adopted as a means of assessing MPs within either FFP or other blood products.


Asunto(s)
Micropartículas Derivadas de Células/química , Luz , Tamaño de la Partícula , Plasma/química , Dispersión de Radiación , Humanos
20.
Int J Lab Hematol ; 30(4): 261-8, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18665822

RESUMEN

Increased thrombin generation in the presence of activated protein C (APC) is known to be an independent risk factor for thrombosis. Although commercially available methods for measuring thrombin generation are available, none measure sensitivity to APC. We have developed an automated thrombin generation based APC sensitivity test, for use with defibrinated plasma using the automated coagulometer (ACL9000). A chromogenic substrate that is cleaved by thrombin at a slow rate, 7 pm tissue factor and 20 mum phospholipid (DOPC : DOPE : DOPS, 60 : 20 : 20) with and without 5 nm APC. Thrombin generation with [endogenous thrombin potential (ETP)(+APC)] and without APC (ETP), was expressed as a ratio relative to pooled normal plasma. Normal reference ranges were established in 30 normal subjects: ETP 0.73-1.06; ETP(+APC) 0.42-1.07. ETP(+APC) was found to be sensitive to factor V Leiden, oral contraceptive use, low levels of protein S and tissue factor pathway inhibitor and increased plasma factor VIII.


Asunto(s)
Pruebas de Coagulación Sanguínea/métodos , Proteína C/fisiología , Trombina/análisis , Compuestos Cromogénicos , Humanos , Valores de Referencia , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS