Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
2.
Interv Cardiol Clin ; 13(2): 191-205, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38432762

RESUMEN

Mitral regurgitation complicated by cardiogenic shock creates a unique and devastating risk profile for patients and poses significant difficulties for physicians who lack a comprehensive range of effective management strategies. Supportive measures such as intravenous vasodilators, intra-aortic balloon pumps, and percutaneous ventricular assist devices are often necessary to stabilize patients prior to definitive treatment with surgical mitral valve replacement or trans-catheter edge-to-edge repair. This review evaluates the evidence for the available supportive and definitive management strategies in patients with mitral regurgitation complicated by cardiogenic shock and presents a framework to aid clinicians in navigating the complex clinical decision-making process. Additionally, the authors review emerging transcatheter mitral valve replacement technologies that hold promise for expanding the therapeutic armamentarium and improving patient outcomes.


Asunto(s)
Corazón Auxiliar , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/cirugía , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia , Toma de Decisiones Clínicas , Medición de Riesgo
3.
Interv Cardiol Clin ; 13(2): 167-182, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38432760

RESUMEN

Functional mitral regurgitation appears commonly among all heart failure phenotypes and can affect symptom burden and degree of maladaptive remodeling. Transcatheter mitral valve edge-to-edge repair therapies recently became an important part of the routine heart failure armamentarium for carefully selected and medically optimized candidates. Patient selection is considering heart failure staging, relevant comorbidities, as well as anatomic criteria. Indications and device platforms are currently expanding.


Asunto(s)
Insuficiencia Cardíaca , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/cirugía , Selección de Paciente , Insuficiencia Cardíaca/cirugía , Carga Sintomática
5.
Int J Mol Sci ; 24(8)2023 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-37108729

RESUMEN

People living with HIV (PLHIV) are at a higher risk of having cerebrocardiovascular diseases (CVD) compared to HIV negative (HIVneg) individuals. The mechanisms underlying this elevated risk remains elusive. We hypothesize that HIV infection results in modified microRNA (miR) content in plasma extracellular vesicles (EVs), which modulates the functionality of vascular repairing cells, i.e., endothelial colony-forming cells (ECFCs) in humans or lineage negative bone marrow cells (lin- BMCs) in mice, and vascular wall cells. PLHIV (N = 74) have increased atherosclerosis and fewer ECFCs than HIVneg individuals (N = 23). Plasma from PLHIV was fractionated into EVs (HIVposEVs) and plasma depleted of EVs (HIV PLdepEVs). HIVposEVs, but not HIV PLdepEVs or HIVnegEVs (EVs from HIVneg individuals), increased atherosclerosis in apoE-/- mice, which was accompanied by elevated senescence and impaired functionality of arterial cells and lin- BMCs. Small RNA-seq identified EV-miRs overrepresented in HIVposEVs, including let-7b-5p. MSC (mesenchymal stromal cell)-derived tailored EVs (TEVs) loaded with the antagomir for let-7b-5p (miRZip-let-7b) counteracted, while TEVs loaded with let-7b-5p recapitulated the effects of HIVposEVs in vivo. Lin- BMCs overexpressing Hmga2 (a let-7b-5p target gene) lacking the 3'UTR and as such is resistant to miR-mediated regulation showed protection against HIVposEVs-induced changes in lin- BMCs in vitro. Our data provide a mechanism to explain, at least in part, the increased CVD risk seen in PLHIV.


Asunto(s)
Aterosclerosis , MicroARN Circulante , Vesículas Extracelulares , Infecciones por VIH , MicroARNs , Humanos , Animales , Ratones , Infecciones por VIH/complicaciones , Infecciones por VIH/genética , MicroARNs/genética , Vesículas Extracelulares/genética , Aterosclerosis/genética
6.
J Am Soc Echocardiogr ; 35(5): 495-502, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34973393

RESUMEN

BACKGROUND: In heart failure with reduced ejection fraction (HFrEF), abnormal regulation of skeletal muscle perfusion contributes to reduced exercise tolerance. The aim of this study was to test the hypothesis that improvement in functional status after permanent left ventricular assist device (LVAD) implantation in patients with HFrEF is related to improvement in muscle perfusion during work, which was measured using contrast-enhanced ultrasound (CEUS). METHODS: CEUS perfusion imaging of calf muscle at rest and during low-intensity plantar flexion exercise (20 W, 0.2 Hz) was performed in patients with HFrEF (n = 22) at baseline and 3 months after placement of permanent LVADs. Parametric analysis of CEUS data was used to quantify muscle microvascular blood flow (MBF), blood volume index, and red blood cell flux rate. For subjects alive at 3 months, comparisons were made between those with New York Heart Association functional class I or II (n = 13) versus III or IV (n = 7) status after LVAD. Subjects were followed for a median of 5.7 years for mortality. RESULTS: Echocardiographic data before and after LVAD placement and LVAD parameters were similar in subjects classified with New York Heart Association functional class I-II versus functional class III-IV after LVAD. Skeletal muscle MBF at rest and during exercise before LVAD implantation was also similar between groups. After LVAD placement, resting MBF remained similar between groups, but during exercise those with New York Heart Association functional class I or II had greater exercise MBF (111 ± 60 vs 52 ± 38 intensity units/sec, P = .03), MBF reserve (median, 4.45 [3.95 to 6.80] vs 2.22 [0.98 to 3.80]; P = .02), and percentage change in exercise MBF (median, 73% [-28% to 83%] vs -45% [-80% to 26%]; P = .03). During exercise, increases in MBF were attributable to faster microvascular flux rate, with little change in blood volume index, indicating impaired exercise-mediated microvascular recruitment. The only clinical or echocardiographic feature that correlated with post-LVAD exercise MBF was a history of diabetes mellitus. There was a trend toward better survival in patients who demonstrated improvement in muscle exercise MBF after LVAD placement (P = .05). CONCLUSIONS: CEUS perfusion imaging can quantify peripheral vascular responses to advanced therapies for HFrEF. After LVAD implantation, improvement in functional class is seen in patients with improvements in skeletal muscle exercise perfusion and flux rate, implicating a change in vasoactive substances that control resistance arteriolar tone.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Humanos , Músculo Esquelético/diagnóstico por imagen , Perfusión , Volumen Sistólico
7.
J Card Surg ; 35(12): 3405-3408, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33001467

RESUMEN

BACKGROUND: Heart failure is an epidemic affecting over 6 million people in the United States. Eighty percent of all heart failure patients are older than 65 years of age. Heart transplant is the gold standard treatment for patients suffering advanced heart failure, but only 18.5% of patients receiving heart transplant in the United States are 65 years of age or older. Continuous-flow left ventricular assist devices are a safe and effective therapy for patients with advanced heart failure, and can be used to bridge patients to a heart transplant or to support patients long-term as destination therapy. MATERIAL AND METHODS: We sought to characterize long-term outcomes of elderly patients receiving continuous-flow left ventricular support in our program. CONCLUSION: Elderly patients with advanced heart failure presented comparable operative results to those of younger patients. The rate of complications up to 6 years of support was low, and comparable to those of younger patients. An effective and safe alternative for patients whom are less likely to receive heart transplantation.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Anciano , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Humanos , Estudios Retrospectivos , Resultado del Tratamiento , Estados Unidos/epidemiología
8.
Arterioscler Thromb Vasc Biol ; 37(2): 280-290, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27908889

RESUMEN

OBJECTIVE: Lineage-negative bone marrow cells (lin- BMCs) are enriched in endothelial progenitor cells and mediate vascular repair. Aging-associated senescence and apoptosis result in reduced number and functionality of lin- BMCs, impairing their prorepair capacity. The molecular mechanisms underlying lin- BMC senescence and apoptosis are poorly understood. MicroRNAs (miRNAs) regulate many important biological processes. The identification of miRNA-mRNA networks that modulate the health and functionality of lin- BMCs is a critical step in understanding the process of vascular repair. The aim of this study was to characterize the role of the miR-146a-Polo-like kinase 2 (Plk2) network in regulating lin- BMC senescence, apoptosis, and their angiogenic capability. APPROACH AND RESULTS: Transcriptome analysis in lin- BMCs isolated from young and aged wild-type and ApoE-/- (apolipoprotein E) mice showed a significant age-associated increase in miR-146a expression. In silico analysis, expression study and Luciferase reporter assay established Plk2 as a direct target of miR-146a. miR-146a overexpression in young lin- BMCs inhibited Plk2 expression, resulting in increased senescence and apoptosis, via p16Ink4a/p19Arf and p53, respectively, as well as impaired angiogenic capacity in vitro and in vivo. Conversely, suppression of miR-146a in aged lin- BMCs increased Plk2 expression and rejuvenated lin- BMCs, resulting in decreased senescence and apoptosis, leading to improved angiogenesis. CONCLUSIONS: (1) miR-146a regulates lin- BMC senescence and apoptosis by suppressing Plk2 expression that, in turn, activates p16Ink4a/p19Arf and p53 and (2) modulation of miR-146a or its target Plk2 may represent a potential therapeutic intervention to improve lin- BMC-mediated angiogenesis and vascular repair.


Asunto(s)
Apoptosis , Células de la Médula Ósea/enzimología , Linaje de la Célula , Senescencia Celular , Células Progenitoras Endoteliales/enzimología , MicroARNs/metabolismo , Proteínas Serina-Treonina Quinasas/metabolismo , Regiones no Traducidas 3' , Factores de Edad , Animales , Apolipoproteínas E/deficiencia , Apolipoproteínas E/genética , Sitios de Unión , Células de la Médula Ósea/patología , Movimiento Celular , Proliferación Celular , Inhibidor p16 de la Quinasa Dependiente de Ciclina/metabolismo , Regulación hacia Abajo , Células Progenitoras Endoteliales/patología , Genotipo , Células HEK293 , Humanos , Ratones Endogámicos C57BL , Ratones Noqueados , MicroARNs/genética , Neovascularización Fisiológica , Fenotipo , Fosforilación , Proteínas Serina-Treonina Quinasas/genética , Interferencia de ARN , Transducción de Señal , Transcriptoma , Transfección , Proteína p53 Supresora de Tumor/metabolismo
9.
JAMA Cardiol ; 1(8): 890-899, 2016 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-27627616

RESUMEN

Importance: The 2015 cardiopulmonary resuscitation and emergency cardiovascular care guidelines recommend performing coronary angiography in resuscitated patients after cardiac arrest with or without ST-segment elevation (STE). Objective: To assess the temporal trends, predictors, and outcomes of performing coronary angiography and percutaneous coronary intervention (PCI) in patients resuscitated after out-of-hospital cardiac arrest (OHCA) with initial rhythms of ventricular tachycardia or pulseless ventricular fibrillation (VT/VF). Design, Setting, and Participants: An observational analysis of the use of coronary angiography and PCI in 407 974 patients hospitalized after VT/VF OHCA from January 1, 2000, through December 31, 2012, from the Nationwide Inpatient Sample database. Multivariable analysis was used to assess factors associated with coronary angiography and PCI use. Data analysis was performed from December 12, 2015, to January 5, 2016. Main Outcomes and Measures: Temporal trends of coronary angiography, PCI, and survival to discharge in patients with VT/VF OHCA. Results: Among the 407 974 patients hospitalized after VT/VF OHCA, 143 688 (35.2%) were selected to undergo coronary angiography. The mean (SD) age of the total population was 65.7 (14.9) years, 37.9% were female, and 74.1% were white, 13.4% black, 6.8% Hispanic, and 5.7% other race. Use of coronary angiography increased from 27.2% in 2000 to 43.9% in 2012 (odds ratio, 2.47; 95% CI, 2.25-2.71; P for trend < .001), and PCI increased from 9.5% in 2000 to 24.1% in 2012 (odds ratio, 4.80; 95% CI, 4.21-5.66; P for trend < .001). From 2000 to 2012, coronary angiography and PCI after VT/VF OHCA increased in patients with STE (53.7% to 87.2%, P for trend < .001, and 29.7% to 77.3%, P for trend < .001, respectively) and those without STE (19.3% to 33.9%, P for trend < .001, and 3.5% to 11.8%, P for trend < .001, respectively). There was an associated increasing trend in survival to discharge in the overall population of patients with VT/VF OHCA (46.9% to 60.1%, P for trend < .001) in those with STE (59.2% to 74.3%, P for trend < .001) or without STE (43.3% to 56.8%, P for trend < .001). Conclusions and Relevance: Coronary angiography, PCI, and survival to discharge have increased in VT/VF OHCA survivors from event to hospitalization. However, a significant proportion of patients with VT/VF OHCA, especially those without STE, do not undergo coronary angiography and revascularization. Prospective studies are needed to determine whether this limitation has a survival effect.


Asunto(s)
Angiografía Coronaria , Paro Cardíaco Extrahospitalario/mortalidad , Intervención Coronaria Percutánea , Fibrilación Ventricular , Anciano , Femenino , Humanos , Persona de Mediana Edad , Paro Cardíaco Extrahospitalario/diagnóstico , Paro Cardíaco Extrahospitalario/terapia , Estudios Prospectivos , Estudios Retrospectivos , Taquicardia Ventricular
10.
Int J Cardiol ; 222: 531-537, 2016 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-27509222

RESUMEN

INTRODUCTION: The effect of acute changes of hemoglobin during index heart failure admission on long-term outcomes remains unknown. METHODS: We examined 433 patients enrolled in the ESCAPE trial. RESULTS: Of the 433 patients, 324 (75%) had baseline and discharge hemoglobin available for analysis. Of those, 64 (20%) had at least 1g/dL drop of hemoglobin by time of discharge. Compared to patients without hemoglobin changes (g/dL), patients with hemoglobin drop were older (59 vs. 55, p=0.011), had lower systolic BP (mmHg) (99 vs. 106, p=0.017), lower sodium (mg/dL) (136 vs. 137 (mg/dL), p=0.025), higher BUN (mg/dL) (37 vs. 26, p<0.001), higher creatinine (mg/dL) (1.6 vs. 1.3, p<0.001) and higher hospital length of stay (10days vs. 6days, p=<0.001). Higher hemoglobin drop was observed in the pulmonary artery catheter (PACs) (vs. clinical care) randomized arm of the trial (2g/dL: 10% versus 3%, p=0.010; 3g/dL: 5% versus 0%, p=0.005). After adjustments, a drop of hemoglobin with at least 1g/dL was associated with increased mortality risk (Adjusted HR 2.38, p=0.003) and higher hemoglobin concentrations by the time of discharge was associated with lower mortality rate (Adjusted HR 0.79, p=0.003). PACs insertion was not associated with adverse clinical outcomes by quartiles of % change of hemoglobin. However, PACs use was an independent predictor of hemoglobin drop during heart failure admission (Adjusted OR: Hb Drop 1g/dL: 1.88, p=0.043; Hb Drop 2g/dL: 3.6 p=0.025). CONCLUSION: In-hospital decrease in hemoglobin is independently associated with increased long-term mortality and hospital length of stay in ADHF. The ideal hemoglobin levels in ADHF patients should be investigated and the insertion of PACs to direct therapy should be weighed against bleeding risks.


Asunto(s)
Cateterismo Cardíaco/mortalidad , Cateterismo Cardíaco/tendencias , Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/mortalidad , Hemoglobinas/metabolismo , Hospitalización/tendencias , Enfermedad Aguda , Anciano , Biomarcadores/sangre , Femenino , Insuficiencia Cardíaca/diagnóstico , Humanos , Tiempo de Internación/tendencias , Masculino , Persona de Mediana Edad , Mortalidad/tendencias
11.
JACC Heart Fail ; 4(5): 348-56, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-26874392

RESUMEN

OBJECTIVES: The aim of this study was to assess temporal trends and factors associated with digoxin use at discharge among patients admitted with heart failure (HF). BACKGROUND: Digoxin has class IIa recommendations for treating HF with reduced ejection fraction (HFrEF) in the United States. Digoxin use, temporal trends, and clinical characteristics of HF patients in current clinical practice in the United States have not been well studied. METHODS: An observational analysis of 255,901 patients hospitalized with HF (117,761 with HFrEF and 138,140 with preserved EF [HFpEF]) from 398 hospitals participating in the Get With The Guidelines-HF registry between January 2005 and June 2014 was conducted to assess the temporal trends and factors associated with digoxin use. RESULTS: Among 117,761 HFrEF patients, only 19.7% received digoxin at discharge. Digoxin prescriptions decreased from 33.1% in 2005 to 10.7% in 2014 (ptrend < 0.0001). Factors associated with digoxin use in HFrEF included atrial fibrillation (AF) (odds ratio [OR]: 2.14; 95% confidence intervals [CI]: 2.02 to 2.28), history of implantable cardioverter defibrillator use (OR: 1.39; 95% CI: 1.32 to 1.46), chronic obstructive pulmonary disease (OR: 1.13, 95% CI: 1.08 to 1.18), diabetes mellitus (OR: 1.10, 95% CI: 1.06 to 1.14), younger age (OR: 0.96, 95% CI: 0.95 to 0.97), lower blood pressure (OR: 0.96, 95% CI: 0.96 to 0.97), and having no history of renal insufficiency (OR: 0.91, 95% CI: 0.85 to 0.97). Use of digoxin in patients with HFpEF (n = 138,140) without AF was 9.8% in 2005, which decreased to 2.2% in 2014 (ptrend < 0.0001). CONCLUSIONS: One in 5 HFrEF patients received digoxin at discharge, with a significant downward temporal trend in use over the study period. Use of digoxin in HFpEF patients without AF was very low and decreased over the study period.


Asunto(s)
Cardiotónicos/uso terapéutico , Digoxina/uso terapéutico , Insuficiencia Cardíaca/tratamiento farmacológico , Hospitalización , Pautas de la Práctica en Medicina/tendencias , Sistema de Registros , Factores de Edad , Anciano , American Heart Association , Fibrilación Atrial/epidemiología , Presión Sanguínea , Comorbilidad , Desfibriladores Implantables , Diabetes Mellitus/epidemiología , Femenino , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Oportunidad Relativa , Enfermedad Pulmonar Obstructiva Crónica/epidemiología , Insuficiencia Renal/epidemiología , Volumen Sistólico , Estados Unidos
12.
Am J Cardiol ; 116(1): 132-41, 2015 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-25983278

RESUMEN

In recent years, there has been an increased emphasis on the diagnosis and treatment of valvular heart disease and, in particular, aortic stenosis. This has been driven in part by the development of innovative therapeutic options and by an aging patient population. We hypothesized an increase in the number of hospitalizations and the economic burden associated with aortic valve disease (AVD). Using Nationwide Inpatient Sample from 2000 to 2012, AVD-related hospitalizations were identified using International Classification of Diseases, Ninth Revision, Clinical Modification, code 424.1, as the principal discharge diagnosis. Overall AVD hospitalizations increased by 59% from 2000 to 2012. This increase was most significant in patients >80 years and those with higher burden of co-morbidities. The most frequent coexisting conditions were hypertension, heart failure, renal failure, anemia, and diabetes. Overall inhospital mortality of patients hospitalized for AVD was 3.8%, which significantly decreased from 4.5% in 2000 to 3.5% in 2012 (p <0.001). The largest decrease in mortality was seen in the subgroup of patients who had heart failure (62% reduction), higher burden of co-morbidities (58% reduction), and who were >80 years (53% reduction). There was a substantial increase in the cost of hospitalization in the last decade from $31,909 to $38,172 (p <0.001). The total annual cost for AVD hospitalization in the United States increased from $1.3 billion in 2001 to $2.1 billion in 2011 and is expected to increase to nearly 3 billion by 2020. The last decade has witnessed a significant increase in hospitalizations for AVD in the United States. The associated decrease in inhospital mortality and increase in the cost of hospitalization have considerably increased the economic burden on the public health system.


Asunto(s)
Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/terapia , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/terapia , Mortalidad Hospitalaria/tendencias , Hospitalización/tendencias , Anciano , Anciano de 80 o más Años , Válvula Aórtica , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/terapia , Enfermedad de la Válvula Aórtica Bicúspide , Costo de Enfermedad , Femenino , Cardiopatías Congénitas/economía , Cardiopatías Congénitas/mortalidad , Enfermedades de las Válvulas Cardíacas/economía , Enfermedades de las Válvulas Cardíacas/mortalidad , Hospitalización/economía , Humanos , Masculino , Persona de Mediana Edad , Medición de Riesgo , Factores de Riesgo , Estados Unidos
13.
J Interv Cardiol ; 28(3): 266-78, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25991422

RESUMEN

INTRODUCTION: Both transfemoral (TF) and transapical (TA) routes are utilized for Transcatheter Aortic Valve Replacement (TAVR) using Edwards SAPIEN & SAPIEN XT valves. We intended to perform a meta-analysis comparing the complication rates between these two approaches in studies published before and after the standardized Valve Academic Research Consortium (VARC) definitions. METHODS: We performed a comprehensive electronic database search for studies published until January 2014 comparing TF and TA approaches using the Edwards SAPIEN/SAPIEN XT aortic valve. Studies were analyzed based on the following endpoints: 1-year mortality, 30-day mortality, stroke, new pacemaker implantation, bleeding, and acute kidney injury. RESULTS: Seventeen studies were included in the meta-analysis. Patients undergoing TA TAVR had a significantly higher logistic EuroSCORE (24.6 ± 12.9 vs. 21.3 ± 12.0; P < 0.001). The cumulative risks for 30-day mortality (RR 0.61; 95%CI 0.46-0.81; P = 0.001), 1-year mortality (RR 0.68; 95%CI 0.55-0.84; P < 0.001), and acute kidney injury (RR 0.53; 95%CI 0.38-0.73; P < 0.001) were significantly lower for patients undergoing TF as compared to TA approach. Both approaches had a similar incidence of 30-day stroke, pacemaker implantation, and major or life-threatening bleeding. Studies utilizing the VARC definitions and those pre-dating VARC yielded similar results. CONCLUSION: This meta-analysis demonstrates a decreased 30-day and 1-year mortality in TF TAVR as compared to TA TAVR. Post-procedure acute kidney injury and the need for renal replacement therapy are also significantly lower in the TF group. These differences hold true even after utilizing the standardized Valve Academic Research Consortium criteria.


Asunto(s)
Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Lesión Renal Aguda/etiología , Hemorragia/etiología , Humanos , Marcapaso Artificial , Terapia de Reemplazo Renal , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad
14.
Am J Cardiol ; 115(4): 480-6, 2015 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-25543235

RESUMEN

The use of percutaneous aortic balloon balvotomy (PABV) in high surgical risk patients has resurged because of development of less invasive endovascular therapies. We compared outcomes of concomitant PABV and percutaneous coronary intervention (PCI) with PABV alone during same hospitalization using nation's largest hospitalization database. We identified patients and determined time trends using the International Classification of Diseases, Ninth Revision, Clinical Modification, procedure code for valvulotomy from Nationwide Inpatient Sample database 1998 to 2010. Only patients >60 years with aortic stenosis were included. Primary outcome included in-hospital mortality, and secondary outcomes included procedural complications, length of stay (LOS), and cost of hospitalization. Total 2,127 PABV procedures were identified, with 247 in PABV + PCI group and 1,880 in the PABV group. Utilization rate of concomitant PABV + PCI during same hospitalization increased by 225% from 5.1% in 1998 to 1999 to 16.6% in 2009 to 2010 (p <0.001). Overall in-hospital mortality rate and complication rates in PABV + PCI group were similar to that of PABV group (10.3% vs 10.5% and 23.4% vs 24.7%, respectively). PABV + PCI group had similar LOS but higher hospitalization cost (median [interquartile range] $30,089 [$21,925 to $48,267] versus $18,421 [$11,482 to $32,215], p <0.001) in comparison with the PABV group. Unstable condition, occurrence of any complication, and weekend admission were the main predictors of increased LOS and cost of hospital admission. Concomitant PCI and PABV during the same hospitalization are not associated with change in in-hospital mortality, complications rate, or LOS compared with PABV alone; however, it increases the cost of hospitalization.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Valvuloplastia con Balón , Intervención Coronaria Percutánea , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Femenino , Mortalidad Hospitalaria/tendencias , Humanos , Tiempo de Internación/tendencias , Masculino , Pronóstico , Estudios Retrospectivos , Tasa de Supervivencia/tendencias , Factores de Tiempo , Estados Unidos/epidemiología
15.
Catheter Cardiovasc Interv ; 85(7): 1226-30, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25511236

RESUMEN

OBJECTIVE: We investigated the long-term safety, efficacy and clinical outcomes associated with transaortic (TAO) transcatheter aortic valve replacement (TAVR) in the United States. BACKGROUND: We previously reported the technical feasibility and short-term safety of TAO TAVR. Compared to transapical (TAP) access, the TAO approach was associated with shorter median intensive care unit (ICU) length of stay (LOS) and more favorable technical learning curve. However, outcomes data beyond 30 days were lacking and the longer-term clinical consequences of this strategy were unknown. METHODS: Mortality outcomes at 1 year (and longer) of 44 consecutive patients who underwent TAO TAVR in our institution were compared with that of 76 consecutive patients who underwent TAP TAVR at our site. Risk-adjusted analysis was performed in propensity-matched patients (25 from each group) to account for baseline differences. RESULTS: TAO TAVR was associated with a trend towards lower all-cause mortality at 1 year compared to TAP TAVR (18% vs. 34%, P=0.09 in the overall sample; 12% vs. 40%, P=0.05 in the matched cohort). The higher probability of survival with TAO TAVR persisted after a median follow-up period of 23 months (hazard ratio [HR]=1.96, P=0.06 in the overall sample; HR=3.4, P=0.01 in the matched cohort). Cardiovascular mortality at 1 year was lower with TAO TAVR (2% vs. 22%, P=0.01 in the overall sample; 4% vs. 28%, P=0.05 in the matched cohort). ICU LOS (shorter in the TAO group) and implantation of second prosthetic valve (higher incidence in the TAP group) were independent predictors of long-term mortality. CONCLUSION: The outcomes associated with TAO TAVR compare favorably with TAP TAVR. Our results appear to corroborate the long-term safety and efficacy of the TAO approach in TAVR patients with inadequate iliofemoral access.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Distribución de Chi-Cuadrado , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Unidades de Cuidados Intensivos , Estimación de Kaplan-Meier , Tiempo de Internación , Modelos Logísticos , Masculino , Análisis Multivariante , Puntaje de Propensión , Diseño de Prótesis , Sistema de Registros , Retratamiento , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
16.
AJR Am J Roentgenol ; 203(6): W596-604, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25415724

RESUMEN

OBJECTIVE: The purpose of this article is to review the utility of ECG-gated MDCT in evaluating postsurgical findings in aortic and mitral valves. Normal and pathologic findings after aortic and mitral valve corrective surgery are shown in correlation with the findings of the traditionally used imaging modalities echocardiography and fluoroscopy to assist in accurate noninvasive anatomic and dynamic evaluation of postsurgical valvular abnormalities. CONCLUSION: Because of its superior spatial and adequate temporal resolution, ECG-gated MDCT has emerged as a robust diagnostic tool in the evaluation and treatment of patients with postsurgical valvular abnormalities.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas/métodos , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/cirugía , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Tomografía Computarizada Multidetector/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide , Humanos , Pronóstico , Resultado del Tratamiento
17.
Catheter Cardiovasc Interv ; 84(1): 124-8, 2014 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-24659187

RESUMEN

OBJECTIVE: We explored the efficacy, safety, and clinical consequences of on-label and off-label transcatheter aortic valve replacement (TAVR) in the real-world setting. BACKGROUND: The transcatheter heart valve (THV) was initially approved only for transfemoral (TF) delivery (on-label use) during TAVR in inoperable patients with severe aortic stenosis (AS). Because of lack of alternative options in TAVR-eligible patients with inadequate TF access, other routes have been utilized for THV implantation (off-label use), outcomes of which were previously unknown. METHODS: Consecutive patients with severe inoperable AS who underwent clinical TAVR at our site were enrolled in a prospective database. Fifty subjects underwent TF-TAVR (on-label group), while non-TF routes were utilized in 60 subjects (off-label group). Procedural events, 30-day clinical outcomes, and 1-year all-cause mortality data were analyzed. RESULTS: Technical device success was similar between on-label and off-label groups (88% vs. 87%, respectively; P = 0.92), as was the incidence of procedural complications and 30-day clinical events. The on-label group had lower 1-year all-cause death rate (12%) compared to the off-label group (32%; P = 0.02). The 1-year all-cause mortality in the off-label group was comparable to published clinical trial and registry data on TAVR, and appeared lower than historical outcomes with conservative medical therapy. CONCLUSION: On-label use of the THV in the real-world setting was associated with favorable survival outcomes compared to off-label TAVR and historical data. Off-label use of the THV appeared to be safe and effective when used in select patients with inoperable AS who are not eligible for TAVR via TF approach.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Medición de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Causas de Muerte/tendencias , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Prospectivos , Factores de Riesgo , Tasa de Supervivencia/tendencias , Resultado del Tratamiento , Estados Unidos/epidemiología
18.
J Am Coll Cardiol ; 63(15): 1510-9, 2014 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-24486264

RESUMEN

OBJECTIVES: This study sought to determine the incidence of new-onset atrial fibrillation (AF) associated with different methods of isolated aortic valve replacement (AVR)-transfemoral (TF), transapical (TA), and transaortic (TAo) catheter-based valve replacement and conventional surgical approaches. BACKGROUND: The relative incidences of AF associated with the various access routes for AVR have not been well characterized. METHODS: In this single-center, retrospective cohort study, we evaluated a total of 231 consecutive patients who underwent AVR for degenerative aortic stenosis (AS) between March 2010 and September 2012. Patients with a history of paroxysmal, persistent, or chronic AF, with bicuspid aortic valves, and patients who died within 48 h after AVR were excluded. A total of 123 patients (53% of total group) qualified for inclusion. Data on documented episodes of new-onset AF, along with all clinical, echocardiographic, procedural, and 30-day follow-up data, were collated. RESULTS: AF occurred in 52 patients (42.3%). AF incidence varied according to the procedural method. AF occurred in 60% of patients who underwent surgical AVR (SAVR), in 53% after TA-TAVR, in 33% after TAo-TAVR cases, and 14% after TF-TAVR. The episodes occurred at a median time interval of 53 (25th to 75th percentile, 41 to 87) h after completion of the procedure. Procedures without pericardiotomy had an 82% risk reduction of AF compared with those with pericardiotomy (adjusted odds ratio: 0.18; 95% confidence interval: 0.05 to 0.59). CONCLUSIONS: AF was a common complication of AVR with a cumulative incidence of >40% in elderly patients with degenerative AS who underwent either SAVR or TAVR. AF was most common with SAVR and least common with TF-TAVR. Procedures without pericardiotomy were associated with a lower incidence of AF.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Fibrilación Atrial/epidemiología , Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Anciano de 80 o más Años , Aorta Torácica , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Fibrilación Atrial/etiología , Cateterismo Cardíaco/métodos , Intervalos de Confianza , Ecocardiografía , Femenino , Arteria Femoral , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Incidencia , Masculino , Oportunidad Relativa , Complicaciones Posoperatorias , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos/epidemiología
19.
Catheter Cardiovasc Interv ; 84(1): 114-21, 2014 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-24436032

RESUMEN

OBJECTIVES: To assess the impact of the Centers for Medicare and Medicaid Services (CMS) national coverage determination (NCD) on access for patients with aortic stenosis (AS) with transcatheter aortic valve replacement (TAVR) in a tertiary care center. BACKGROUND: TAVR has given hope to patients with AS who are deemed inoperable. The effects of the NCD on access to patients with AS has not been evaluated. MATERIALS AND METHODS: A total of 94 inoperable AS patients were evaluated and treated from December 2011 through June of 2012 with TAVR. Patients who underwent transfemoral (TF) vs. non-TF access were compared. The CMS NCD was released on May 1, 2012 and on July 1, 2012, the nontransfemoral access program was put on hold due to lack of reimbursement. RESULTS: Patients in the TF (n = 33) and non-TF access (n = 61) groups were similar in age (85.2 ± 6.3 vs. 84.8 ± 6.6 P = 0.74) and STS mortality (9.38 ± 5.33 vs. 7.91 ± 3.69, P = 0.074). The iliofemoral arteries were larger diameter in the TF group (7.72 ± 1.49 vs. 6.21 ± 1.78, P < 0.001) and males (7.39 ± 1.81 vs. 6.1 ± 1.61 P < 0.001). More women underwent valve implantation via non-TF access (73 vs. 23%, P = 0.03). After the NCD, 21 patients who previously qualified for non-TF TAVR would not be reimbursed by CMS. Four died soon after. CONCLUSIONS: After the NCD, the proportion of inoperable patients with severe AS that can be treated with TAVR was greatly reduced due the lack of reimbursement for TAVR via non-TF access. This effect is particularly pronounced in women. © 2014 Wiley Periodicals, Inc.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Centers for Medicare and Medicaid Services, U.S./estadística & datos numéricos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Cateterismo Cardíaco , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia/tendencias , Reemplazo de la Válvula Aórtica Transcatéter/economía , Resultado del Tratamiento , Estados Unidos/epidemiología
20.
Postgrad Med ; 125(5): 31-42, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24113661

RESUMEN

Transcatheter aortic valve replacement has emerged as an alternative option for inoperable or very high-risk patients with severe aortic stenosis-however, there are serious complications associated with the procedure, such as patient mortality, stroke, conduction disturbances, paravalvular regurgitation, and vascular concerns. Our review focuses on the most common complications related to transcatheter aortic valve replacement procedures and potential bailout strategies and techniques.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas/efectos adversos , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/terapia , Anciano , Anciano de 80 o más Años , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...