Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Environ Toxicol Pharmacol ; 103: 104282, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37769889

RESUMEN

The presence of particles fixed in tissue samples due to implant degradation or disintegration plays an important role in post-operative complications. The ability to determine the size, shape, chemical composition and, above all, the number of these particles can be used in many areas of medicine. This study presents a novel, simple metal-based particle detection method using scanning electron microscopy with energy dispersive spectrometer (SEM-EDS). The presence of metal particles in biopsy specimens from long bone nail-fixated implants (10 patients with titanium steel nails and 10 patients with stainless steel nails) was studied. The samples were analysed using automated area analysis based on image binarization and brightness to 255 grayscale. The results were supplemented with histological data and statistically analysed. The method based on the software used was found to be accurate and easy to use and, thus, appears to be very suitable for particle detection in similar samples.

2.
J Clin Med ; 12(6)2023 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-36983141

RESUMEN

One of the crucial tasks for the planning of surgery of the iliosacral joint is placing an iliosacral screw with the goal of fixing broken parts of the pelvis. Tracking of proper screw trajectory is usually done in the preoperative phase by the acquisition of X-ray images under different angles, which guide the surgeons to perform surgery. This approach is standardly complicated due to the investigation of 2D X-ray images not showing spatial perspective. Therefore, in this pilot study, we propose complex software tools which are aimed at making a simulation model of reconstructed CT (DDR) images with a virtual iliosacral screw to guide the surgery process. This pilot study presents the testing for two clinical cases to reveal the initial performance and usability of this software in clinical conditions. This model is consequently used for a multiregional registration with reference intraoperative X-ray images to select the slide from the 3D dataset which best fits with reference X-ray. The proposed software solution utilizes input CT slices of the pelvis area to create a segmentation model of individual bone components. Consequently, a model of an iliosacral screw is inserted into this model. In the next step, we propose the software CT2DDR which makes DDR projections with the iliosacral screw. In the last step, we propose a multimodal registration procedure, which performs registration of a selected number of slices with reference X-ray, and based on the Structural Similarity Index (SSIM) and index of correlation, the procedure finds the best match of DDR with X-ray images. In this pilot study, we also provide a comparative analysis of the computational costs of the multimodal registration upon various numbers of DDR slices to show the complex software performance. The proposed complex model has versatile usage for modeling and surgery planning of the pelvis area in fractures of iliosacral joints.

3.
Materials (Basel) ; 16(2)2023 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-36676374

RESUMEN

Anodization coloring of titanium tools or implants is one of the common methods for the differentiation of each application by its size or type. Commercial purity titanium grade 4 plates (50 × 20 × 0.1 mm) were tested to obtain their electrochemical and other technological properties. The coloring process was done using the potential of 15, 30, 45, 60, and 75 Volts for 5 s in 1 wt. % citric acid in demineralized water solution. Organic acids solutions generally produce better surface quality compared to inorganic acids. The contact angle of colored surfaces was measured by the sessile drop method. Electrochemical impedance spectroscopy and potentiodynamic polarization were used for the determination of selected electrochemical and corrosion parameters of the tested surfaces. It was found that the anodization process decreases corrosion potential significantly. It was also confirmed that a higher potential used for anodization results in higher polarization resistance but also a decrease in corrosion potential. The anodization process at 75 V produces surfaces with the lowest corrosion rate under 1 nm/year and the noblest corrosion potential. It was confirmed that the anodization process in citric acid does not affect titanium cytotoxicity.

4.
Eur J Trauma Emerg Surg ; 48(6): 4897-4902, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35796781

RESUMEN

PURPOSE: Treatment of pelvic fractures is often complicated. Here, we intended to evaluate the intraoperative benefits of using 2D computer navigation when compared with traditional fluoroscopy on X-ray burden, surgical time and screw placement accuracy. METHODS: In this study, we retrospectively evaluated the records of 25 patients who underwent osteosynthesis of a posterior pelvic fracture using fluoroscopy at the University Hospital Ostrava, Czech Republic between 2011 and 2019, and 32 patients from the same department and period in whom 2D computer navigation was used. RESULTS: Intraoperative X-ray burden was significantly lower in the group with 2D computer navigation (median 650 vs 1024 cGy/cm2), as was the duration of the surgery (41 vs 45 min). This was most obvious where two screws were inserted (X-ray dose of 994 vs 1847 cGy/cm2 and 48 vs 70 min, respectively). Correction of the path for wire placement after the original drilling was necessary in 2 patients (6%) from the 2D computer navigation group and 15 patients from the fluoroscopy group (60%). Still, no malposition of the screws nor dislocation of the posterior pelvic segment after 12 months was observed in any patient of either group; of complications, only three superficial infections in the 2D navigation group and 2 in the fluoroscopy group were observed. CONCLUSION: 2D computer navigation is a safe and accurate method for placement of screws during posterior pelvic fracture osteosynthesis, associated with lower intraoperative radiation burden and shorter surgical times compared to standard fluoroscopy, especially if two screws are inserted.


Asunto(s)
Fracturas Óseas , Cirugía Asistida por Computador , Humanos , Estudios Retrospectivos , Cirugía Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Tornillos Óseos , Fluoroscopía/métodos , Fijación Interna de Fracturas/métodos , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Computadores
5.
J Clin Med ; 11(2)2022 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-35054056

RESUMEN

Data on the effectiveness of arthroscopic arthrolysis and extraction of osteosynthetic material after osteosynthesis of the proximal humerus in patients with persisting problems are rare and insufficient. In this study, we performed arthroscopic arthrolysis and extraction of fixation screws, and, where protruding, extraction of the nail in 34 patients with problems persisting 12 months after osteosynthesis of the proximal humerus using an intramedullary nail. The effectiveness of the treatment was assessed using the Constant-Murley shoulder score and forward flexion difference between the treated arm and the contralateral one. A median increase of 16 points in CMS score and 30 degrees reduction in the arm forward flexion difference was recorded 12 months after the arthroscopy. The improvement was significantly higher in the patient group with intramedullary nail extraction (however, this group had worse pre-operative values and the screw was only extracted where likely to cause problems). The median time to heal was 11 weeks; no serious peri- or post-procedural complications occurred. Mini-invasive arthroscopic arthrolysis combined with extraction of osteosynthetic material proved to be a safe and effective method for treatment of patients after osteosynthesis of the proximal humerus using an intramedullary nail with persisting pain and/or mobility limitation.

6.
Open Med (Wars) ; 16(1): 1597-1601, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34722895

RESUMEN

INTRODUCTION: Reports on the use of computer-assisted trauma surgery of comminuted scapula fracture are still quite rare. In this article, we present a case of comminuted scapula fracture, the surgical reconstruction of which was pre-operatively planned using a complex software solution. MATERIALS AND METHODS: For surgical planning of the fracture, we used the TraumaTech software facilitating virtual reconstruction (both manual and automatic), surgery planning, design of the implant, planning of screw placement and lengths, and production of a 3D print model of the fracture and the implant. The software also supported ordering such custom-made plate from a plate producer who was capable of fast and precise production of the plate. RESULTS: The surgery using the custom-ordered plate was successful. The actual used screw lengths did not differ from the planned ones by more than 2 mm. One year after the surgery, the patient was capable of more demanding activities and doing sports activities. CONCLUSION: This approach provides a great way to prevent complications of the surgery and to shorten its duration. To the best of our knowledge, this is the first description of the treatment of a scapula comminuted fracture utilizing computer-assisted preoperative planning.

7.
Medicina (Kaunas) ; 57(8)2021 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-34440997

RESUMEN

Background: The standard ATLS protocol calls for chest drain insertion in patients with hemothorax before performing further diagnostic steps. However, if trauma-induced thoracic aortic rupture is the underlying cause, such drainage can lead to massive bleeding and death of the patient. Case report: This report describes a case of a polytrauma patient (car accident), aged 21, with symmetrical chest and decreased breath sounds dorsally on the left. An urgent CT scan revealed subadventitial Grade III thoracic aortic transection with mediastinal hematoma, a massive left-sided hemothorax with mediastinal shift to the right, and other injuries. Stent-graft implantation with subsequent left hemithorax drainage was urgently performed, during which the patient became increasingly unstable from the circulatory point of view. This traumatic hemorrhagic shock was successfully managed at the ICU. Conclusion: Although hemothorax is a serious condition requiring rapid treatment, the knowledge of its origin is of utmost importance; performing chest drainage without bleeding control can lead to circulatory instability and death of the patient. Hence, where aortic injury can be suspected based on the mechanism of the injury, it is beneficial to perform spiral CT angiography for accurate diagnosis first and, in cases of aortic injury, to control the bleeding prior to drainage.


Asunto(s)
Rotura de la Aorta , Hemotórax , Rotura de la Aorta/complicaciones , Rotura de la Aorta/diagnóstico por imagen , Rotura de la Aorta/cirugía , Hemotórax/diagnóstico por imagen , Hemotórax/etiología , Hemotórax/cirugía , Humanos , Tomografía Computarizada por Rayos X
8.
J Healthc Eng ; 2018: 8538125, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29854367

RESUMEN

A model-based radiostereometric analysis (MBRSA) is a method for precise measurement of prosthesis migration, which does not require marking the implant with tantalum beads. Instead, the prosthesis pose is typically recovered using a feature-based 2D-3D registration of its virtual model into a stereo pair of radiographs. In this study, we evaluate a novel intensity-based formulation of previously published nonoverlapping area (NOA) approach. The registration is capable of performing with both binary radiographic segmentations and nonsegmented X-ray images. In contrast with the feature-based version, it is capable of dealing with unreliable parts of prosthesis. As the straightforward formulation allows efficient acceleration using modern graphics adapters, it is possible to involve precise high-poly virtual models. Moreover, in case of binary segmentations, the nonoverlapping area is simply interpretable and useful for indicating the accuracy of the registration outcome. In silico and phantom evaluations were performed using a cementless Zweymüller femoral stem and its reverse engineered (RE) model. For initial pose estimates with difference from the ground-truth limited to ±4 mm and ±4°, respectively, the mean absolute translational error was not higher than 0.042 ± 0.035 mm. The error in rotation around the proximodistal axis was 0.181 ± 0.265°, and the error for the remaining axes was not higher than 0.035 ± 0.037°.


Asunto(s)
Análisis de Falla de Equipo/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Análisis Radioestereométrico/métodos , Fémur/diagnóstico por imagen , Prótesis de Cadera , Humanos , Fantasmas de Imagen , Tantalio
9.
Artículo en Inglés | MEDLINE | ID: mdl-15523551

RESUMEN

In the statement authors want to draw attention to the possibilities of treatment of periprosthetic fractures of femur. They present their own experiences with the treatment of these fractures by using various types of internal and external fixation evaluated from 1996 to 2003. They present some less common types of internal fixation as e.g. fixation by clamp plates.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Fracturas del Fémur/cirugía , Anciano , Femenino , Fijación de Fractura/métodos , Humanos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...