Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Cardiol ; 82(4): 240-247, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37116648

RESUMEN

BACKGROUND: The new sizing options of the MitraClip system (Abbott Vascular, Abbott Park, IL, USA) with extended clip arms were recently developed. Its applicability and effectiveness for ventricular functional mitral regurgitation (VFMR) are yet to be investigated. METHODS: We retrospectively reviewed consecutive patients with symptomatic VFMR who underwent transcatheter edge-to-edge repair between 2018 and 2022 at the Sakakibara Heart Institute. Pre- and post-procedural mitral valve morphologies were assessed using three-dimensional transesophageal echocardiography. RESULTS: In a total of 104 VFMR patients, the posterior mitral leaflet length was 12.8 ±â€¯2.8 mm and 92 % was indicative of the extended arm (≥9 mm). Although baseline VFMR was more severe in the patients treated with the extended arms (n = 35, XT group) than the patients treated with the standard arms (n = 69, NT group), the decrease in VFMR was greater in the XT group (delta three-dimensional vena contracta area - 43 ±â€¯33 mm2 vs. -31 ±â€¯22 mm2, p = 0.030) and residual VFMR was similar between the groups, with a significantly greater reduction in the mitral annulus anterior-posterior diameter (-4.9 ±â€¯2.2 mm vs -3.1 ±â€¯2.1 mm, p < 0.001) and mitral annulus area in the XT group. The use of extended arms was independently associated with shorter procedure time (81 ±â€¯26 min vs 108 ±â€¯41 min) after adjustment for device generation and the number of clips (p = 0.017). CONCLUSIONS: Most VFMR patients had enough leaflet lengths for transcatheter edge-to-edge repair using the MitraClip with the extended arms, which was associated with shorter procedure time and a greater decrease in the mitral annular size.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Estudios Retrospectivos , Brazo , Instrumentos Quirúrgicos , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco/métodos
2.
J Pers Med ; 13(2)2023 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-36836459

RESUMEN

Venous thromboembolism (VTE) is a common comorbidity of cancer, often referred to as cancer-associated thrombosis (CAT). Even though its prevalence has been increasing, its clinical picture has not been thoroughly investigated. In this single-center retrospective observational study, 259 patients who were treated for pulmonary embolism (PE) between January 2015 and December 2020 were available for analysis. The patients were divided by the presence or absence of concomitant malignancy, and those with malignancy (N = 120, 46%) were further classified into active (N = 40, 15%) and inactive groups according to the treatment status of malignancy. In patients with malignancy, PE was more often diagnosed incidentally by computed tomography or D-dimer testing, and the proportion of massive PE was lower. Although D-dimer levels overall decreased after the initiation of anticoagulation therapy, concomitant malignancy was independently associated with higher D-dimer at discharge despite the lower severity of PE at onset. The patients with malignancy had a poor prognosis during post-discharge follow-up. Active malignancy was independently associated with major adverse cardiovascular events (MACE) and major bleeding. D-dimer at discharge was an independent predictor of mortality even after adjustment for malignancy. This study's findings suggest that CAT-PE patients might have hypercoagulable states, which can potentially lead to a poorer prognosis.

3.
Intern Med ; 62(9): 1305-1309, 2023 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-36104196

RESUMEN

Platypnea-orthodeoxia syndrome (POS) is a rare disease characterized by dyspnea and hypoxemia in orthostatism that improves in the recumbent position. We herein report an 81-year-old woman with dyspnea in the upright position following thoracic vertebral compression fractures. After the patient's daughter brought a recording showing decreasing SpO2 (peripheral capillary oxygen saturation) in the upright position as measured by a portable pulse oximeter outside the hospital, a small atrial septal defect (ASD) was detected. A contrast echocardiogram and four-dimensional flow magnetic resonance imaging demonstrated a right-to-left shunt. The patient's symptoms dramatically improved after percutaneous ASD closure. In conclusion, such new technologies are useful for diagnosing POS.


Asunto(s)
Foramen Oval Permeable , Fracturas por Compresión , Defectos del Tabique Interatrial , Fracturas de la Columna Vertebral , Femenino , Humanos , Anciano de 80 o más Años , Síndrome de Platipnea Ortodesoxia , Postura , Defectos del Tabique Interatrial/diagnóstico , Defectos del Tabique Interatrial/diagnóstico por imagen , Oxígeno , Hipoxia/diagnóstico , Hipoxia/etiología , Disnea/diagnóstico , Disnea/etiología , Foramen Oval Permeable/diagnóstico , Foramen Oval Permeable/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...