Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
PLoS One ; 8(3): e60059, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23555883

RESUMEN

In order to counter the common perception that molecular diagnostics are too complicated to work in low resource settings, we have performed a difficult sample preparation and DNA amplification protocol using instrumentation designed to be operated without wall or battery power. In this work we have combined a nearly electricity-free nucleic acid extraction process with an electricity-free isothermal amplification assay to detect the presence of Clostridium difficile (C. difficile) DNA in the stool of infected patients. We used helicase-dependent isothermal amplification (HDA) to amplify the DNA in a low-cost, thermoplastic reaction chip heated with a pair of commercially available toe warmers, while using a simple Styrofoam insulator. DNA was extracted from known positive and negative stool samples. The DNA extraction protocol utilized an air pressure driven solid phase extraction device run using a standard bicycle pump. The simple heater setup required no electricity or battery and was capable of maintaining the temperature at 65°C±2°C for 55 min, suitable for repeatable HDA amplification. Experiments were performed to explore the adaptability of the system for use in a range of ambient conditions. When compared to a traditional centrifuge extraction protocol and a laboratory thermocycler, this disposable, no power platform achieved approximately the same lower limit of detection (1.25×10(-2) pg of C. difficile DNA) while requiring much less raw material and a fraction of the lab infrastructure and cost. This proof of concept study could greatly impact the accessibility of molecular assays for applications in global health.


Asunto(s)
ADN/genética , Diarrea/microbiología , Técnicas de Amplificación de Ácido Nucleico/métodos , Clostridioides difficile/genética , Clostridioides difficile/aislamiento & purificación , Clostridioides difficile/patogenicidad , Humanos , Temperatura
2.
Diagnostics (Basel) ; 3(1): 155-169, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26617991

RESUMEN

We report a disposable and highly effective polymeric microfluidic viral sample concentration device capable of increasing the concentration of virus in a human nasopharyngeal specimen more than one order of magnitude in less than 30 min without the use of a centrifuge. The device is fabricated using 3D maskless xurography method using commercially available polymeric materials, which require no cleanroom operations. The disposable components can be fabricated and assembled in five minutes. The device can concentrate a few milliliters (mL) of influenza virus in solution from tissue culture or clinical nasopharyngeal swab specimens, via reduction of the fluid volume, to tens of microliters µL). The performance of the device was evaluated by nucleic acid extraction from the concentrated samples, followed by a real-time quantitative polymerase chain reaction (qRT-PCR). The viral RNA concentration in each sample was increased on average over 10-fold for both cultured and patient specimens compared to the starting samples, with recovery efficiencies above 60% for all input concentrations. Highly concentrated samples in small fluid volumes can increase the downstream process speed of on-chip nucleic acid extraction, and result in improvements in the sensitivity of many diagnostic platforms that interrogate small sample volumes.

3.
PLoS One ; 7(3): e33176, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22457740

RESUMEN

A rapid, low cost, accurate point-of-care (POC) device to detect influenza virus is needed for effective treatment and control of both seasonal and pandemic strains. We developed a single-use microfluidic chip that integrates solid phase extraction (SPE) and molecular amplification via a reverse transcription polymerase chain reaction (RT-PCR) to amplify influenza virus type A RNA. We demonstrated the ability of the chip to amplify influenza A RNA in human nasopharyngeal aspirate (NPA) and nasopharyngeal swab (NPS) specimens collected at two clinical sites from 2008-2010. The microfluidic test was dramatically more sensitive than two currently used rapid immunoassays and had high specificity that was essentially equivalent to the rapid assays and direct fluorescent antigen (DFA) testing. We report 96% (CI 89%,99%) sensitivity and 100% (CI 95%,100%) specificity compared to conventional (bench top) RT-PCR based on the testing of n = 146 specimens (positive predictive value = 100%(CI 94%,100%) and negative predictive value = 96%(CI 88%,98%)). These results compare well with DFA performed on samples taken during the same time period (98% (CI 91%,100%) sensitivity and 96%(CI 86%,99%) specificity compared to our gold standard testing). Rapid immunoassay tests on samples taken during the enrollment period were less reliable (49%(CI 38%,61%) sensitivity and 98%(CI 98%,100%) specificity). The microfluidic test extracted and amplified influenza A RNA directly from clinical specimens with viral loads down to 10³ copies/ml in 3 h or less. The new test represents a major improvement over viral culture in terms of turn around time, over rapid immunoassay tests in terms of sensitivity, and over bench top RT-PCR and DFA in terms of ease of use and portability.


Asunto(s)
Virus de la Influenza A/genética , Microfluídica/instrumentación , Nasofaringe/virología , ARN Viral/genética , Secuencia de Bases , Electroforesis en Gel de Poliacrilamida , Humanos , Gripe Humana/diagnóstico , Gripe Humana/virología , Datos de Secuencia Molecular , Sistemas de Atención de Punto , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Sensibilidad y Especificidad , Homología de Secuencia de Ácido Nucleico
4.
Anal Chem ; 84(3): 1336-44, 2012 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-22240089

RESUMEN

Cells of biomedical interest are, despite their functional significance, often present in very small numbers. Therefore the analysis and isolation of previously inaccessible rare cells, such as peripheral hematopoietic stem cells, endothelial progenitor cells, or circulating tumor cells, require efficient, sensitive, and specific procedures that do not compromise the viability of the cells. The current study builds on previous work on a rationally designed microfluidic magnetophoretic cell separation platform capable of throughputs of 240 µL min(-1). Proof-of-concept was first conducted using MCF-7 (1-1000 total cells) as the target rare cell spiked into high concentrations of Raji B-lymphocyte nontarget cells (~10(6) total cells). These experiments lead to the establishment of a magnet-based separation for the isolation of 50 MCF-7 cells directly from whole blood. Results show an efficiency of collection greater than 85%, with a purity of over 90%. Next, resident endothelial progenitor cells and hematopoietic stem cells are directly isolated from whole human blood in a rapid and efficient fashion (>96%). Both cell populations could be simultaneously isolated and, via immunofluorescent staining, individually identified and enumerated. Overall, the presented device illustrates a viable separation platform for high purity, efficient, and rapid collection of rare cell populations directly from whole blood samples.


Asunto(s)
Separación Inmunomagnética , Técnicas Analíticas Microfluídicas , Células Cultivadas , Citometría de Flujo , Células Madre Hematopoyéticas/citología , Células Madre Hematopoyéticas/metabolismo , Humanos , Células Neoplásicas Circulantes/metabolismo , ARN/análisis , ARN/aislamiento & purificación , Células Madre/citología , Células Madre/metabolismo
5.
Biomed Microdevices ; 13(3): 599-602, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21369762

RESUMEN

In the original manuscript, we reported the demonstration of an integrated microfluidic chip that performed helicase dependent amplification (HDA) on samples containing live bacteria. Bacterial lysis, nucleic acid extraction, and DNA amplification with a fluorescent reporter were incorporated into a disposable polymer cartridge format. We reported that the device was able to detect as few as 10 colony-forming units (CFU) of E. coli in growth medium. While the main conclusions of the original paper remain sound, the data presented in support of those conclusions contained errors that we detail, discuss and correct here. In short, we misidentified a non-specific product as a specific product of our HDA reaction. We incorrectly called reactions containing the non-specific product (length 70 bp) positive. Further investigation demonstrated that our primer set was faulty and not capable of amplifying the specific product. Here we redesigned primers, sequenced all of the products and reran all of the experiments reported previously to generate a new, verified dataset.


Asunto(s)
ADN Helicasas/metabolismo , ADN Bacteriano/genética , ADN Bacteriano/aislamiento & purificación , Equipos Desechables , Técnicas de Amplificación de Ácido Nucleico/instrumentación , Integración de Sistemas , ADN Bacteriano/metabolismo , Escherichia coli O157/genética , Escherichia coli O157/aislamiento & purificación
6.
Biomed Microdevices ; 12(2): 353-9, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20066496

RESUMEN

Here we report the demonstration of an integrated microfluidic chip that performs helicase dependent amplification (HDA) on samples containing live bacteria. Combined chip-based sample preparation and isothermal amplification are attractive for world health applications, since the need for instrumentation to control flow rate and temperature changes are reduced or eliminated. Bacteria lysis, nucleic acid extraction, and DNA amplification with a fluorescent reporter are incorporated into a disposable polymer cartridge format. Smart passive fluidic control using a flap valve and a hydrophobic vent (with a nanoporous PTFE membrane) with a simple on-chip mixer eliminates multiple user operations. The device is able to detect as few as ten colony forming units (CFU) of E. coli in growth medium.


Asunto(s)
ADN Helicasas/genética , ADN Helicasas/metabolismo , ADN/genética , Microfluídica/instrumentación , Técnicas de Amplificación de Ácido Nucleico/instrumentación , Bacterias/genética , Bacterias/metabolismo , Medios de Cultivo , ADN Polimerasa Dirigida por ADN/metabolismo , Heces , Análisis de Secuencia por Matrices de Oligonucleótidos/instrumentación , Temperatura
7.
Lab Chip ; 9(19): 2811-7, 2009 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-19967118

RESUMEN

Sepsis caused by gram positive and gram negative bacteria is the leading cause of death in noncoronary ICUs and the tenth leading cause of death in the United States. We have developed a microfluidic sample preparation platform for rapid on-chip detection of infectious organisms for point-of-care diagnostics. The microfluidic chips are made of a robust thermoplastic and can be easily multiplexed for high throughput applications. Bacteria are lysed on-chip via hybrid chemical/mechanical method. Once lysed, the bacterial DNA is isolated using a microscale silica bead/polymer composite solid-phase-extraction (SPE) column. Lysis was confirmed using off-chip real time PCR. We isolated and detected both gram-negative (Escherichia coli) and gram-positive (Bacillussubtilis and Enterococcus faecalis) bacterial genomic DNA from microliter scale spiked whole human blood samples. The system performs better for gram-negative bacteria than it does for gram-positive bacteria, with limits of detection at 10(2) CFU/ml and 10(3)-10(4) CFU/ml, respectively. Total extraction times are less than one hour and can be further decreased by altering the channel geometry and pumping configuration.


Asunto(s)
Bacillus subtilis/aislamiento & purificación , ADN Bacteriano/sangre , ADN Bacteriano/aislamiento & purificación , Equipos Desechables , Enterococcus faecalis/aislamiento & purificación , Escherichia coli/aislamiento & purificación , Técnicas Analíticas Microfluídicas/métodos , Bacillus subtilis/genética , Bacteriólisis , Enterococcus faecalis/genética , Escherichia coli/genética , Humanos , Técnicas Analíticas Microfluídicas/instrumentación , Sistemas de Atención de Punto , Polímeros/química , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Dióxido de Silicio/química , Extracción en Fase Sólida
8.
J Microbiol Methods ; 78(2): 203-7, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19505511

RESUMEN

In this paper, we describe the design of a microfluidic sample preparation chip for human stool samples infected with Clostridium difficile. We established a polymerase chain reaction able to distinguish C. difficile in the presence of several other organisms found in the normal intestinal flora. A protocol for on-chip extraction of nucleic acids from clinical samples is described that can detect target DNA down to 5.0x10(-3) ng of template. The assay and sample preparation chip were then validated using known positive and known negative clinical samples. The work presented has potential applications in both the developed and developing world.


Asunto(s)
Clostridioides difficile/aislamiento & purificación , ADN Bacteriano/aislamiento & purificación , Heces/microbiología , Reacción en Cadena de la Polimerasa/métodos , Clostridioides difficile/genética , Humanos , Sensibilidad y Especificidad
9.
Biomed Microdevices ; 11(3): 671-678, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19130239

RESUMEN

Silica impregnated polymer monolithic columns may provide a simple method for lysing and extracting DNA from bacteria inside of microfluidic chips. Here we use Escherichia coli as a test organism for a point of care thermoplastic microfluidic module designed to take in a urine sample, mix it with lysis buffer, and perform a hybrid chemical/mechanical lysis and solid phase extraction of nucleic acids from the sample. To demonstrate proof-of-concept, we doped human hematuric urine samples with E. coli at concentrations ranging from 10(1)-10(5) colony-forming units/mL (CFU/mL) to simulate patient samples. We then performed on-chip lysis and DNA extraction. The bacterial DNA was amplified using real-time PCR demonstrating lysis and isolation down to 10(1) CFU/mL. Results were comparable to a commercial kit at higher concentrations and performed better at recovering DNA at lower concentrations.


Asunto(s)
Bacteriólisis , ADN Bacteriano/aislamiento & purificación , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Orina/microbiología , Bioensayo , Simulación por Computador , Equipos Desechables , Escherichia coli/genética , Proteínas Fluorescentes Verdes/genética , Humanos , Microscopía Electrónica de Rastreo , Miniaturización , Plásmidos , Reacción en Cadena de la Polimerasa , Juego de Reactivos para Diagnóstico , Dióxido de Silicio/química
10.
J Virol ; 83(2): 662-72, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18987151

RESUMEN

We assessed differences in the character and specificity of autologous neutralizing antibodies (ANAbs) against individual viral variants of the quasispecies in a cohort of drug-naïve subjects with long-term controlled human immunodeficiency virus type 1 (HIV-1) infection and moderate levels of broad heterologous neutralizing antibodies (HNAb). Functional plasma virus showed continuous env evolution despite a short time frame and low levels of viral replication. Neutralization-sensitive variants dominated in subjects with intermittent viral blips, while neutralization-resistant variants predominated in elite controllers. By sequence analysis of this panel of autologous variants with various sensitivities to neutralization, we identified more than 30 residues in envelope proteins (Env) associated with resistance or sensitivity to ANAbs. The appearance of new sensitive variants is consistent with a model of continuous selection and turnover. Strong ANAb responses directed against autologous Env variants are present in long-term chronically infected individuals, suggesting a role for these responses in contributing to the durable control of HIV replication.


Asunto(s)
Anticuerpos Anti-VIH/inmunología , Infecciones por VIH/inmunología , Infecciones por VIH/virología , Sobrevivientes de VIH a Largo Plazo , VIH-1/inmunología , Selección Genética , Estudios de Cohortes , Anticuerpos Anti-VIH/sangre , VIH-1/clasificación , VIH-1/genética , VIH-1/aislamiento & purificación , Humanos , Modelos Moleculares , Datos de Secuencia Molecular , Mutación Missense/inmunología , Pruebas de Neutralización , Filogenia , Plasma/virología , Estructura Cuaternaria de Proteína , Análisis de Secuencia de ADN , Productos del Gen env del Virus de la Inmunodeficiencia Humana/genética
11.
J Immunol ; 177(6): 4028-36, 2006 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-16951366

RESUMEN

Previously, Ab-dependent cellular cytotoxicity (ADCC) was significantly correlated with reduced acute viremia upon intrarectal SIVmac251 challenge of immunized rhesus macaques. To directly assess ADCC protective efficacy, six neonatal macaques were infused s.c. with immune IgG (220 mg/kg) purified from the immunized animals and positive for ADCC and Ab-dependent cell-mediated viral inhibition (ADCVI) activities. Six neonates received control IgG. The neonates were challenged twice orally with 10(5) 50% inhibiting tissue culture-infective dose of SIVmac251 2 days post-IgG infusion. At challenge, plasma of neonates that received immune IgG did not neutralize SIVmac251 but had geometric mean ADCC titers of 48,130 and 232,850 against SIVmac251 -infected and gp120-coated targets, respectively. Peak ADCVI activity varied from 62 to 81%. ADCC activity declined with the 2-wk IgG half-life but was boosted at wk 4, together with de novo ADCC-mediating Abs in controls, by postchallenge viremia. ADCVI activity was similarly induced. No protection, assessed by viral burdens, CD4 counts, and time to euthanasia was observed. Possible factors contributing to the discrepancy between the previous correlation and lack of protection here include: the high oral challenge dose compared with the 400-fold lower intrarectal dose; the challenge route with regard to viral dissemination and distribution of infused IgG; insufficient NK effector activity and/or poor functionality in newborns; insufficient immune IgG; and the possibility that the previous correlation of ADCC with protection was augmented by cellular immune responses also present at challenge. Future studies should explore additional challenge routes in juvenile macaques using higher amounts of potent IgG preparations.


Asunto(s)
Citotoxicidad Celular Dependiente de Anticuerpos/inmunología , Inmunización Pasiva , Inmunoglobulina G/administración & dosificación , Inmunoglobulina G/fisiología , Síndrome de Inmunodeficiencia Adquirida del Simio/inmunología , Virus de la Inmunodeficiencia de los Simios/inmunología , Administración Oral , Animales , Animales Recién Nacidos , Evaluación Preclínica de Medicamentos , Inmunoglobulina G/química , Macaca mulatta , Síndrome de Inmunodeficiencia Adquirida del Simio/prevención & control
12.
J Clin Microbiol ; 42(8): 3670-4, 2004 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-15297515

RESUMEN

Drug-resistant mutants of human immunodeficiency virus type 1 (HIV-1) recede below the limit of detection of most assays applied to plasma when selective pressure is altered due to changes in antiretroviral treatment (ART). Viral variants with different mutations are selected by the new ART when replication is not suppressed or wild-type variants with greater replication fitness outgrow mutants following the cessation of ART. Mutants selected by past ART appear to persist in reservoirs even when not detected in the plasma, and when conferring cross-resistance they can compromise the efficacy of novel ART. Oligonucleotide ligation assay (OLA) of virus in plasma and peripheral blood mononuclear cells (PBMC) was compared to consensus sequence dideoxynucleotide chain terminator sequencing for detection of 91 drug resistance mutations that had receded below the limit of detection by sequencing of plasma. OLA of plasma virus detected 27.5% (95% confidence interval [CI], 19 to 39%) of mutant genotypes; consensus sequencing of the PBMC amplicon from the same specimen detected 23.1% (95% CI, 14 to 34%); and OLA of PBMC detected 53.8% (95% CI, 44 to 64%). These data suggest that concentrations of drug-resistant mutants were greater in PBMC than in plasma after changes in ART and indicate that the OLA was more sensitive than consensus sequencing in detecting low levels of select drug-resistant mutants.


Asunto(s)
Farmacorresistencia Viral , VIH-1/genética , Síndrome de Inmunodeficiencia Adquirida/diagnóstico , Secuencia de Bases , Cartilla de ADN , ADN Viral/sangre , Productos del Gen pol/genética , Infecciones por VIH/sangre , Infecciones por VIH/diagnóstico , Infecciones por VIH/inmunología , VIH-1/efectos de los fármacos , VIH-1/aislamiento & purificación , Humanos , Mutación , ARN Viral/sangre , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Sensibilidad y Especificidad
13.
J Virol ; 77(10): 5721-30, 2003 May.
Artículo en Inglés | MEDLINE | ID: mdl-12719565

RESUMEN

To evaluate human immunodeficiency virus type 1 (HIV-1) replication and selection of drug-resistant viruses during seemingly effective highly active antiretroviral therapy (HAART), multiple HIV-1 env and pol sequences were analyzed and viral DNA levels were quantified from nucleoside analog-experienced children prior to and during a median of 5.1 (range, 1.8 to 6.4) years of HAART. Viral replication was detected at different rates, with apparently increasing sensitivity: 1 of 10 by phylogenetic analysis; 2 of 10 by viral evolution with increasing genetic distances from the most recent common ancestor (MRCA) of infection; 3 of 10 by selection of drug-resistant mutants; and 6 of 10 by maintenance of genetic distances from the MRCA. When four- or five-drug antiretroviral regimens were given to these children, persistent plasma viral rebound did not occur despite the accumulation of highly drug-resistant genotypes. Among the four children without genetic evidence of viral replication, a statistically significant decrease in the genetic distance to the MRCA was detected in three, indicating the persistence of a greater number of early compared to recent viruses, and their HIV-1 DNA decreased by > or =0.9 log(10), resulting in lower absolute DNA levels (P = 0.007). This study demonstrates the variable rates of viral replication when HAART has suppressed plasma HIV-1 RNA for years to a median of <50 copies/ml and that combinations of four or five antiretroviral drugs suppress viral replication even after short-term virologic failure of three-drug HAART and despite ongoing accumulation of drug-resistant mutants. Furthermore, the decrease of cellular HIV-1 DNA to low absolute levels in those without genetic evidence of viral replication suggests that monitoring viral DNA during HAART may gauge low-level replication.


Asunto(s)
Terapia Antirretroviral Altamente Activa , Farmacorresistencia Viral/genética , Infecciones por VIH/tratamiento farmacológico , VIH-1/genética , Replicación Viral , Niño , Preescolar , ADN Viral/sangre , Evolución Molecular , Infecciones por VIH/virología , VIH-1/efectos de los fármacos , VIH-1/fisiología , Humanos , Lactante , Datos de Secuencia Molecular , Filogenia , ARN Viral/sangre , Análisis de Secuencia de ADN
14.
J Clin Microbiol ; 40(4): 1413-9, 2002 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-11923366

RESUMEN

A sensitive, specific, and high-throughput oligonucleotide ligation assay (OLA) for the detection of genotypic human immunodeficiency virus type 1 (HIV-1) resistance to Food and Drug Administration-approved protease inhibitors was developed and evaluated. This ligation-based assay uses differentially modified oligonucleotides specific for wild-type or mutant sequences, allowing sensitive and simple detection of both genotypes in a single well of a microtiter plate. Oligonucleotides were designed to detect primary mutations associated with high-level resistance to amprenavir, nelfinavir, indinavir, ritonavir, saquinavir, and lopinavir, including amino acid substitutions D30N, I50V, V82A/S/T, I84V, N88D, and L90M. Plasma HIV-1 RNA from 54 infected patients was amplified by reverse transcription-PCR and sequenced by using dideoxynucleotide chain terminators for evaluation of mutations associated with drug resistance. These same amplicons were genotyped by the OLA at positions 30, 50, 82, 88, 84, and 90 for a total of 312 codons. The sensitivity of detection of drug-resistant genotypes was 96.7% (87 of 90 mutant codons) in the OLA compared to 92.2% (83 of 90) in consensus sequencing, presumably due to the increased sensitivity of the OLA. The OLA detected genetic subpopulations more often than sequencing, detecting 30 mixtures of mutant and wild-type sequences and two mixtures of drug-resistant sequences compared to 15 detected by DNA sequencing. Reproducible and semiquantitative detection of the mutant and the wild-type genomes by the OLA was observed by analysis of wild-type and mutant plasmid mixtures containing as little as 5% of either genotype in a background of the opposite genome. This rapid, simple, economical, and highly sensitive assay provides a practical alternative to dideoxy sequencing for genotypic evaluation of HIV-1 resistance to antiretrovirals.


Asunto(s)
ADN Ligasas/metabolismo , Farmacorresistencia Viral/genética , Inhibidores de la Proteasa del VIH/farmacología , VIH-1/efectos de los fármacos , Oligonucleótidos/metabolismo , Mutación Puntual , Secuencia de Bases , Productos del Gen pol/genética , Infecciones por VIH/virología , VIH-1/genética , Humanos , Datos de Secuencia Molecular , Oligonucleótidos/química , Oligonucleótidos/genética , ARN Viral/análisis , ARN Viral/sangre , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Sensibilidad y Especificidad , Análisis de Secuencia de ADN , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...