Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 19 de 19
1.
J Appl Clin Med Phys ; 25(2): e14240, 2024 Feb.
Article En | MEDLINE | ID: mdl-38150580

BACKGROUND: Monte Carlo (MC) simulations or measurements in anthropomorphic phantoms are recommended for estimating fetal dose in pregnant patients in radiotherapy. Among the many existing phantoms, there is no commercially available physical phantom representing the entire pregnant woman. PURPOSE: In this study, the development of a low-cost, physical pregnant female phantom was demonstrated using commercially available materials. This phantom is based on the previously published computational phantom. METHODS: Three tissue substitution materials (soft tissue, lung and bone tissue substitution) were developed. To verify Tena's substitution tissue materials, their radiation properties were assessed and compared to ICRP and ICRU materials using MC simulations in MV radiotherapy beams. Validation of the physical phantom was performed by comparing fetal doses obtained by measurements in the phantom with fetal doses obtained by MC simulations in computational phantom, during an MV photon breast radiotherapy treatment. RESULTS: Materials used for building Tena phantom are matched to ICRU materials using physical density, radiation absorption properties and effective atomic number. MC simulations showed that percentage depth doses of Tena and ICRU material comply within 5% for soft and lung tissue, up to 25 cm depth. In the bone tissue, the discrepancy is higher, but again within 5% up to the depth of 5 cm. When the phantom was used for fetal dose measurements in MV photon breast radiotherapy, measured fetal doses complied with fetal doses calculated using MC simulation within 15%. CONCLUSIONS: Physical anthropomorphic phantom of pregnant patient can be manufactured using commercial materials and with low expenses. The files needed for 3D printing are now freely available. This enables further studies and comparison of numerical and physical experiments in diagnostic radiology or radiotherapy.


Pregnant Women , Radiometry , Pregnancy , Humans , Female , Photons/therapeutic use , Radiotherapy Planning, Computer-Assisted , Computer Simulation , Phantoms, Imaging , Monte Carlo Method , Radiotherapy Dosage
2.
Phys Med ; 115: 103159, 2023 Nov.
Article En | MEDLINE | ID: mdl-37852021

It is well known that foetuses are highly sensitive to ionising radiation and special attention to justification and optimisation of radiological procedures involving a pregnant patient is required. A task to review, validate and compare different approaches to managing the pregnant patient and to estimating the associated foetal doses arising from a diagnostic or interventional radiology (DIR) procedure was designed in the framework of EURADOS working group 12. As a first step, a survey of radiation protection practice including dosimetry considerations among EURADOS members was performed using online questionnaire. Then, to evaluate the possible differences in the estimated foetal doses, a comparison of assessed dose values was made for three cases of pregnant patients that underwent different CT procedures. More than 120 professionals from 108 institutions and 17 countries that are involved in managing pregnant patients undergoing DIR procedures answered the questionnaire. Most of the respondents use national or hospital guidelines on the management of pregnant patients undergoing DIR procedures. However, the guidelines differ considerably among respondents. Comparison of foetal dose assessments performed by dosimetry experts showed the variety of methods used as well as large variability of estimated foetal doses in all three cases. Although European and International commission on radiation protection guidelines already exist, they are more than 20 years old and, in some aspects, they are obsolete. This paper shows that there is a need to revise and update these guidelines.


Radiation Protection , Radiology, Interventional , Pregnancy , Female , Humans , Young Adult , Adult , Radiation Dosage , Radiation Protection/methods , Radiography , Radiometry
3.
Acta Radiol ; 64(1): 125-138, 2023 Jan.
Article En | MEDLINE | ID: mdl-34935520

BACKGROUND: Optimizing patient exposure in interventional cardiology is key to avoid skin injuries. PURPOSE: To establish predictive models of peak skin dose (PSD) during percutaneous coronary intervention (PCI), chronic total occlusion percutaneous coronary intervention (CTO), and transcatheter aortic valve implantation (TAVI) procedures. MATERIAL AND METHODS: A total of 534 PCI, 219 CTO, and 209 TAVI were collected from 12 hospitals in eight European countries. Independent associations between PSD and clinical and technical dose determinants were examined for those procedures using multivariate statistical analysis. A priori and a posteriori predictive models were built using stepwise multiple linear regressions. A fourfold cross-validation was performed, and models' performance was evaluated using the root mean square error (RMSE), mean absolute percentage error (MAPE), coefficient of determination (R²), and linear correlation coefficient (r). RESULTS: Multivariate analysis proved technical parameters to overweight clinical complexity indices with PSD mainly affected by fluoroscopy time, tube voltage, tube current, distance to detector, and tube angulation for PCI. For CTO, these were body mass index, tube voltage, and fluoroscopy contribution. For TAVI, these parameters were sex, fluoroscopy time, tube voltage, and cine acquisitions. When benchmarking the predictive models, the correlation coefficients were r = 0.45 for the a priori model and r = 0.89 for the a posteriori model for PCI. These were 0.44 and 0.67, respectively, for the CTO a priori and a posteriori models, and 0.58 and 0.74, respectively, for the TAVI a priori and a posteriori models. CONCLUSION: A priori predictive models can help operators estimate the PSD before performing the intervention while a posteriori models are more accurate estimates and can be useful in the absence of skin dose mapping solutions.


Cardiology , Percutaneous Coronary Intervention , Humans , Radiation Dosage , Skin , Research Design , Cardiology/methods , Fluoroscopy , Coronary Angiography , Treatment Outcome , Radiography, Interventional
4.
Acta Radiol ; 64(1): 108-118, 2023 Jan.
Article En | MEDLINE | ID: mdl-34958271

BACKGROUND: Patients can be exposed to high skin doses during complex interventional cardiology (IC) procedures. PURPOSE: To identify which clinical and technical parameters affect patient exposure and peak skin dose (PSD) and to establish dose reference levels (DRL) per clinical complexity level in IC procedures. MATERIAL AND METHODS: Validation and Estimation of Radiation skin Dose in Interventional Cardiology (VERIDIC) project analyzed prospectively collected patient data from eight European countries and 12 hospitals where percutaneous coronary intervention (PCI), chronic total occlusion PCI (CTO), and transcatheter aortic valve implantation (TAVI) procedures were performed. A total of 62 clinical complexity parameters and 31 technical parameters were collected, univariate regressions were performed to identify those parameters affecting patient exposure and define DRL accordingly. RESULTS: Patient exposure as well as clinical and technical parameters were collected for a total of 534 PCI, 219 CTO, and 209 TAVI. For PCI procedures, body mass index (BMI), number of stents ≥2, and total stent length >28 mm were the most prominent clinical parameters, which increased the PSD value. For CTO, these were total stent length >57 mm, BMI, and previous anterograde or retrograde technique that failed in the same session. For TAVI, these were male sex, BMI, and number of diseased vessels. DRL values for Kerma-area product (PKA), air kerma at patient entrance reference point (Ka,r), fluoroscopy time (FT), and PSD were stratified, respectively, for 14 clinical parameters in PCI, 10 in CTO, and four in TAVI. CONCLUSION: Prior knowledge of the key factors influencing the PSD will help optimize patient radiation protection in IC.


Cardiology , Percutaneous Coronary Intervention , Humans , Male , Female , Radiation Dosage , Radiography, Interventional/methods , Cardiology/methods , Europe , Fluoroscopy/methods , Coronary Angiography
5.
Radiol Oncol ; 56(4): 541-551, 2022 Dec 01.
Article En | MEDLINE | ID: mdl-36259318

BACKGROUND: The incidence of carcinoma during pregnancy is reported to be 1:1000-1:1500 pregnancies with the breast carcinoma being the most commonly diagnosed. Since the fetus is most sensitive to ionizing radiation during the first two trimesters, there are mixed clinical opinions and no uniform guidelines on the use of radiotherapy during pregnancy. Within this study the pregnant female phantom in the second trimester, that can be used for radiotherapy treatment planning (as DICOM data), Monte Carlo simulations (as voxelized geometry) and experimental dosimetry utilizing 3D printing of the molds (as .STL files), was developed. MATERIALS AND METHODS: The developed phantom is based on MRI images of a female patient in her 18th week of pregnancy and CT images after childbirth. Phantom was developed in such a manner that a pregnant female was scanned "in vivo" using MRI during pregnancy and CT after childbirth. For the treatment of left breast carcinoma, 3D conformal radiotherapy was used. The voxelized geometry of the phantom was used for Monte Carlo (MC) simulations using Monte Carlo N-Particle transport codeTM 6.2 (MCNP). CONCLUSIONS: The modeled photon breast radiotherapy plan, applied to the phantom, indicated that the fetus dose is 59 mGy for 50 Gy prescribed to the breast. The results clearly indicate that only 9.5% of the fetal dose is caused by photons that are generated in the accelerator head through scattering and leakage, but the dominant component is scattered radiation from the patient's body.


Breast Neoplasms , Photons , Humans , Pregnancy , Female , Phantoms, Imaging , Monte Carlo Method , Photons/therapeutic use , Radiometry/methods , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/radiotherapy
6.
Front Oncol ; 12: 904563, 2022.
Article En | MEDLINE | ID: mdl-35957900

Since 2010, EURADOS Working Group 9 (Radiation Dosimetry in Radiotherapy) has been involved in the investigation of secondary and scattered radiation doses in X-ray and proton therapy, especially in the case of pediatric patients. The main goal of this paper is to analyze and compare out-of-field neutron and non-neutron organ doses inside 5- and 10-year-old pediatric anthropomorphic phantoms for the treatment of a 5-cm-diameter brain tumor. Proton irradiations were carried out at the Cyclotron Centre Bronowice in IFJ PAN Krakow Poland using a pencil beam scanning technique (PBS) at a gantry with a dedicated scanning nozzle (IBA Proton Therapy System, Proteus 235). Thermoluminescent and radiophotoluminescent dosimeters were used for non-neutron dose measurements while secondary neutrons were measured with track-etched detectors. Out-of-field doses measured using intensity-modulated proton therapy (IMPT) were compared with previous measurements performed within a WG9 for three different photon radiotherapy techniques: 1) intensity-modulated radiation therapy (IMRT), 2) three-dimensional conformal radiation therapy (3D CDRT) performed on a Varian Clinac 2300 linear accelerator (LINAC) in the Centre of Oncology, Krakow, Poland, and 3) Gamma Knife surgery performed on the Leksell Gamma Knife (GK) at the University Hospital Centre Zagreb, Croatia. Phantoms and detectors used in experiments as well as the target location were the same for both photon and proton modalities. The total organ dose equivalent expressed as the sum of neutron and non-neutron components in IMPT was found to be significantly lower (two to three orders of magnitude) in comparison with the different photon radiotherapy techniques for the same delivered tumor dose. For IMPT, neutron doses are lower than non-neutron doses close to the target but become larger than non-neutron doses further away from the target. Results of WG9 studies have provided out-of-field dose levels required for an extensive set of radiotherapy techniques, including proton therapy, and involving a complete description of organ doses of pediatric patients. Such studies are needed for validating mathematical models and Monte Carlo simulation tools for out-of-field dosimetry which is essential for dedicated epidemiological studies which evaluate the risk of second cancers and other late effects for pediatric patients treated with radiotherapy.

7.
Insects ; 13(1)2022 Jan 17.
Article En | MEDLINE | ID: mdl-35055943

Deserts are characterized by unpredictable precipitation and extreme temperatures. Their fauna and flora are sensitive to anthropogenic environmental changes, and often recover slowly from environmental disasters. The effects of oil spills on the biota of desert regions, however, have scarcely been studied. We predicted that terrestrial invertebrates suffer long-term negative effects from an oil spill, due to their close association with the substrate. Thus, we investigated the effects of two oil spills that occurred in 1975 and 2014 in the hyper-arid 'Arava desert (Israel), on a spider that constructs silk-lined nests in burrows in compact, sandy soil in this extreme desert habitat. The spider, Sahastata aravaensis sp. nov. (Filistatidae), is described herein. We assessed spider burrow abundance in plots located in oil-contaminated and nearby uncontaminated clean soil (control) areas over five consecutive years and measured habitat characteristics in these plots. In the laboratory, we determined the preference of individuals for clean vs. oil-contaminated soil as a resting substrate. Finally, as this species was previously undescribed, we added a new species description. The abundance of Sahastata was significantly lower in oil-contaminated plots, and this was the case in the 40-year-old oil spill (1975) as well as in the recent one (2014). In laboratory tests, spiders showed a significant preference for the clean soil substrate over the oil-contaminated substrate. In the field, soil crust hardness and vegetation density did not differ significantly between oil-contaminated and control plots, but these measures were highly variable. The burrows were significantly clustered, suggesting that the young disperse only short distances. In the laboratory adult spiders did not dig burrows, perhaps indicating that adults remain permanently in their natal burrows and that in the field they may use vacant burrows. We conclude that Sahastata populations were affected negatively by the oil spills and these effects were long-lasting. We propose that by monitoring their spatial distribution, burrow-dwelling spiders such as Sahastata can be used as effective bioindicators of soil pollution in desert habitats.

8.
Med Phys ; 49(4): 2672-2683, 2022 Apr.
Article En | MEDLINE | ID: mdl-35090187

PURPOSE: Craniospinal irradiation (CSI) has greatly increased survival rates for patients with a diagnosis of medulloblastoma and other primitive neuroectodermal tumors. However, as it includes exposure of a large volume of healthy tissue to unwanted doses, there is a strong concern about the complications of the treatment, especially for the children. To estimate the risk of second cancers and other unwanted effects, out-of-field dose assessment is necessary. The purpose of this study is to evaluate and compare out-of-field doses in pediatric CSI treatment using conventional and advanced photon radiotherapy (RT) and advanced proton therapy. To our knowledge, it is the first such comparison based on in-phantom measurements. Additionally, for out-of-field doses during photon RT in this and other studies, comparisons were made using analytical modeling. METHODS: In order to describe the out-of-field doses absorbed in a pediatric patient during actual clinical treatment, an anthropomorphic phantom, which mimics the 10-year-old child, was used. Photon 3D-conformal RT (3D-CRT) and two advanced, highly conformal techniques: photon volumetric-modulated arc therapy (VMAT) and active pencil beam scanning (PBS) proton RT were used for CSI treatment. Radiophotoluminescent and poly-allyl-diglycol-carbonate nuclear track detectors were used for photon and neutron dosimetry in the phantom, respectively. Out-of-field doses from neutrons were expressed in terms of dose equivalent. A two-Gaussian model was implemented for out-of-field doses during photon RT. RESULTS: The mean VMAT photon doses per target dose to all organs in this study were under 50% of the target dose (i.e., <500 mGy/Gy), while the mean 3D-CRT photon dose to oesophagus, gall bladder, and thyroid, exceeded that value. However, for 3D-CRT, better sparing was achieved for eyes and lungs. The mean PBS photon doses for all organs were up to three orders of magnitude lower compared to VMAT and 3D-CRT and exceeded 10 mGy/Gy only for the oesophagus, intestine, and lungs. The mean neutron dose equivalent during PBS for eight organs of interest (thyroid, breasts, lungs, liver, stomach, gall bladder, bladder, prostate) ranged from 1.2 mSv/Gy for bladder to 23.1 mSv/Gy for breasts. Comparison of out-of-field doses in this and other phantom studies found in the literature showed that a simple and fast two-Gaussian model for out-of-field doses as a function of distance from the field edge can be applied in a CSI using photon RT techniques. CONCLUSIONS: PBS is the most promising technique for out-of-field dose reduction in comparison to photon techniques. Among photon techniques, VMAT is a preferred choice for most of out-of-field organs and especially for the thyroid, while doses for eyes, breasts, and lungs are lower for 3D-CRT. For organs outside the field edge, a simple analytical model can be helpful for clinicians involved in treatment planning using photon RT but also for retrospective data analysis for cancer risk estimates and epidemiology in general.


Cerebellar Neoplasms , Craniospinal Irradiation , Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Cerebellar Neoplasms/radiotherapy , Child , Craniospinal Irradiation/adverse effects , Craniospinal Irradiation/methods , Humans , Male , Organs at Risk/radiation effects , Protons , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/methods , Radiotherapy, Intensity-Modulated/adverse effects , Radiotherapy, Intensity-Modulated/methods , Retrospective Studies
9.
Appl Radiat Isot ; 154: 108824, 2019 Dec.
Article En | MEDLINE | ID: mdl-31479818

The paper presents the dose mapping of the panoramic 60Co gamma irradiation facility at the Ruder Boskovic Institute in Croatia. Both experimental (using ionisation chamber) and simulation (using the Geant4 Monte Carlo code) studies have been performed and compared. Measured and simulation dose rates are found to be in very good agreement and can be used for the absorbed dose determination in the irradiation chamber in everyday work. In order to get a complete description of the dose distribution in the facility, the transit dose, which has to be taken into consideration at low doses, was also experimentally determined.

10.
Sci Rep ; 8(1): 11828, 2018 08 07.
Article En | MEDLINE | ID: mdl-30087391

Group living animals invariably risk resource competition. Cooperation in foraging, however, may benefit individuals in groups by facilitating an increase in dietary niche. To test this, we performed a comparative study of social and solitary spider species. Three independently derived social species of Stegodyphus (Eresidae) occupy semi-arid savannas and overlap with three solitary congeners. We estimated potential prey availability in the environment and prey acquisition by spiders in their capture webs. We calculated dietary niche width (prey size) and breadth (taxonomic range) to compare resource use for these six species, and investigated the relationships between group size and average individual capture web production, prey biomass intake rate and variance in biomass intake. Cooperative foraging increased dietary niche width and breadth by foraging opportunistically, including both larger prey and a wider taxonomic range of prey in the diet. Individual capture web production decreased with increasing group size, indicating energetic benefits of cooperation, and variance in individual intake rate was reduced. However, individual biomass intake also decreased with increasing group size. While cooperative foraging did not completely offset resource competition among group members, it may contribute to sustaining larger groups by reducing costs of web production, increasing the dietary niche and reducing the variance in prey capture.


Competitive Behavior/physiology , Diet , Predatory Behavior/physiology , Social Behavior , Spiders/physiology , Animals , Feeding Behavior/physiology
11.
Phys Med ; 46: 67-74, 2018 Feb.
Article En | MEDLINE | ID: mdl-29519411

PURPOSE: The feasibility of setting-up generic, hospital-independent dose alert levels to initiate vigilance on possible skin injuries in interventional procedures was studied for three high-dose procedures (chemoembolization (TACE) of the liver, neuro-embolization (NE) and percutaneous coronary intervention (PCI)) in 9 European countries. METHODS: Gafchromic® films and thermoluminescent dosimeters (TLD) were used to determine the Maximum Skin Dose (MSD). Correlation of the online dose indicators (fluoroscopy time, kerma- or dose-area product (KAP or DAP) and cumulative air kerma at interventional reference point (Ka,r)) with MSD was evaluated and used to establish the alert levels corresponding to a MSD of 2 Gy and 5 Gy. The uncertainties of alert levels in terms of DAP and Ka,r, and uncertainty of MSD were calculated. RESULTS: About 20-30% of all MSD values exceeded 2 Gy while only 2-6% exceeded 5 Gy. The correlations suggest that both DAP and Ka,r can be used as a dose indicator for alert levels (Pearson correlation coefficient p mostly >0.8), while fluoroscopy time is not suitable (p mostly <0.6). Generic alert levels based on DAP (Gy cm2) were suggested for MSD of both 2 Gy and 5 Gy (for 5 Gy: TACE 750, PCI 250 and NE 400). The suggested levels are close to the lowest values published in several other studies. The uncertainty of the MSD was estimated to be around 10-15% and of hospital-specific skin dose alert levels about 20-30% (with coverage factor k = 1). CONCLUSIONS: The generic alert levels are feasible for some cases but should be used with caution, only as the first approximation, while hospital-specific alert levels are preferred as the final approach.


Fluoroscopy/adverse effects , Skin/radiation effects , Surgery, Computer-Assisted , Feasibility Studies , Humans , Thermoluminescent Dosimetry
12.
Radiat Prot Dosimetry ; 181(2): 100-110, 2018 Oct 01.
Article En | MEDLINE | ID: mdl-29351691

The purpose of this study was to measure out-of-field organ doses in two anthropomorphic child phantoms for the treatment of large brain arteriovenous malformations (AVMs) using hypofractionated gamma knife (GK) radiosurgery and to compare these with an alternative treatment using intensity-modulated radiation therapy (IMRT). Target volume was identical in size and shape in all cases. Radiophotoluminescent (RPL), thermoluminescent (TL) and optically stimulated luminescent (OSL) dosimeters were used for out-of-field dosimetry during GK treatment and a good agreement within 1-2% between results was shown. In addition, the use of multiple dosimetry systems strengthens the reliability of the findings. The number of GK isocentres was confirmed to be important for the magnitude of out-of-field doses. Measured GK doses for the same distance from the target, when expressed per target dose and isocentre, were comparable in both phantoms. GK out-of-field doses averaged for both phantoms were evaluated to be 120 mGy/Gy for eyes then sharply reduced to 20 mGy/Gy for mandible and slowly reduced up to 0.8 mGy/Gy for testes. Taking into account the fractionation regimen used to treat AVM patients, the total treatment organ doses to the out-of-field organs were calculated and compared with IMRT. The eyes were better spared with GK whilst for more distant organs doses were up to a factor of 2.8 and 4 times larger for GK compared to IMRT in 5-year and 10-year old phantoms, respectively. Presented out-of-field dose values are specific for the investigated AVM case, phantoms and treatment plans used for GK and IMRT, but provide useful information about out-of-field dose levels and emphasise their importance.


Intracranial Arteriovenous Malformations/surgery , Organs at Risk/radiation effects , Phantoms, Imaging , Radiometry/methods , Radiosurgery/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Child , Humans , Radiotherapy Dosage
13.
Radiat Prot Dosimetry ; 176(3): 331-340, 2017 Nov 01.
Article En | MEDLINE | ID: mdl-28338841

The purpose of this study was to measure out-of-field organ doses in clinical conditions in anthropomorphic paediatric phantoms which received a simulated treatment of a brain tumour with intensity modulated radiotherapy (IMRT) and 3D conformal radiotherapy (3D CRT). Organ doses measured with radiophotoluminescent and thermoluminescent dosemeters were on average 1.6 and 3.0 times higher for the 5 y-old than for the 10 y-old phantom for IMRT and 3D CRT, respectively. A larger 5-y to 10-y organ dose ratio for 3D CRT can be explained because the use of a mechanical wedge for the 5-y-old 3D CRT phantom treatment increased out-of-field doses. Due to different configurations of the radiation fields, for both phantoms, the IMRT technique resulted in a higher non-target brain dose and higher eye doses but lower thyroid doses compared to 3D CRT. For 3D CRT (which used a non-coplanar field configuration), eye doses were 3-6% and for IMRT (which used a coplanar field configuration) 27-30% of the treatment dose, respectively. For thyroid and more distant organs, doses were less than 1% of the treatment dose. Comparison of measured doses and doses calculated by the treatment planning system (TPS) showed that the TPS underestimated out-of-field doses both for IMRT and 3D CRT.


Brain Neoplasms/radiotherapy , Craniospinal Irradiation/methods , Radiometry/methods , Radiotherapy Dosage , Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Child , Child, Preschool , Humans , Models, Anatomic , Organs at Risk/radiation effects
14.
Radiat Prot Dosimetry ; 174(2): 287-290, 2017 Apr 25.
Article En | MEDLINE | ID: mdl-27150518

Environmental dosemeters were benchmarked against various dosimetry systems in realistic environmental conditions. For the first time, the dosemeters, provided by two institutions from two different countries, were deployed at 20 sites in Slovenia and Croatia (near the Nuclear Power Plant, NPP Krsko, Slovenia) during two semi-annual periods: summer-autumn and winter-spring. The results obtained using the different dosimetry systems show interesting features concerning local environmental peculiarities. The results of the intercomparison demonstrate an excellent agreement of the ambient doses measured independently by two different institutions and three passive dosimetry systems. Such consistency is crucial for the environmental dosimetry.


Radiation Dosage , Radiation Protection , Radiometry , Croatia , Radiation Monitoring , Slovenia
15.
Sci Rep ; 5: 13284, 2015 Sep 03.
Article En | MEDLINE | ID: mdl-26333675

Kin selected benefits of cooperation result in pronounced kin discrimination and nepotism in many social species and favour the evolution of sociality. However, low variability in relatedness among group members, infrequent competitive interactions with non-relatives, and direct benefits of cooperation may relax selection for nepotism. We tested this prediction in a permanently social spider, Stegodyphus dumicola that appears to fulfil these conditions. Sociality is a derived trait, and kin discrimination exists in sub-social closely related congeners and is likely a selective force in the sub-social route to permanent sociality in spiders. We examined whether social spiders show nepotism in cooperative feeding when genetic relatedness among group members was experimentally varied. We found no effect of relatedness on feeding efficiency, growth rate or participation in feeding events. Previous studies on sub-social species showed benefits of communal feeding with kin, indicating nepotistic cooperation. The lack of evidence for nepotism in the social species suggests that kin discrimination has been lost or is irrelevant in communal feeding. Our results are consistent with the hypothesis that the role of nepotism is diminished when cooperation evolves in certain genetic and ecological contexts, e.g. when intra-group genetic relatedness is homogeneous and encounters with competitors are rare.


Behavior, Animal/physiology , Competitive Behavior/physiology , Cultural Evolution , Evolution, Molecular , Social Behavior , Spiders/genetics , Animals , Social Dominance , Spiders/physiology
16.
Phys Med ; 30(8): 914-9, 2014 Dec.
Article En | MEDLINE | ID: mdl-25266988

Dosimetry for Gamma-Knife requires detectors with high spatial resolution and minimal angular dependence of response. Angular dependence and end effect time for p-type silicon detectors (PTW Diode P and Diode E) and PTW PinPoint ionization chamber were measured with Gamma-Knife beams. Weighted angular dependence correction factors were calculated for each detector. The Gamma-Knife output factors were corrected for angular dependence and end effect time. For Gamma-Knife beams angle range of 84°-54°. Diode P shows considerable angular dependence of 9% and 8% for the 18 mm and 14, 8, 4 mm collimator, respectively. For Diode E this dependence is about 4% for all collimators. PinPoint ionization chamber shows angular dependence of less than 3% for 18, 14 and 8 mm helmet and 10% for 4 mm collimator due to volumetric averaging effect in a small photon beam. Corrected output factors for 14 mm helmet are in very good agreement (within ±0.3%) with published data and values recommended by vendor (Elekta AB, Stockholm, Sweden). For the 8 mm collimator diodes are still in good agreement with recommended values (within ±0.6%), while PinPoint gives 3% less value. For the 4 mm helmet Diodes P and E show over-response of 2.8% and 1.8%, respectively. For PinPoint chamber output factor of 4 mm collimator is 25% lower than Elekta value which is generally not consequence of angular dependence, but of volumetric averaging effect and lack of lateral electronic equilibrium. Diodes P and E represent good choice for Gamma-Knife dosimetry.


Radiometry/instrumentation , Radiosurgery/methods , Algorithms , Humans , Ions , Monte Carlo Method , Phantoms, Imaging , Radiometry/methods , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/instrumentation , Reproducibility of Results , Software
17.
Arh Hig Rada Toksikol ; 65(3): 251-7, 2014 Sep 29.
Article En | MEDLINE | ID: mdl-25205689

Although ionising radiation has proven beneficial in the diagnosis and therapy of a number of diseases, one should keep in mind that irradiating healthy tissue may increase the risk of cancer. In order to justify an exposure to radiation, both the benefits and the risks must be evaluated and compared. The deleterious effects of medium and high doses are well known, but it is much less clear what effects arise from low doses (below 0.1 Gy), which is why such risk estimates are extremely important. This review presents the current state, important assumptions and steps being made in deriving cancer risk estimates for low dose exposures.


Environmental Exposure/adverse effects , Neoplasms, Radiation-Induced/etiology , Radiation, Ionizing , Risk Assessment/trends , Dose-Response Relationship, Radiation , Forecasting , Humans , Models, Theoretical
18.
Naturwissenschaften ; 100(11): 1031-40, 2013 Nov.
Article En | MEDLINE | ID: mdl-24177705

Latitude, rainfall, and productivity have been shown to influence social organisation and level of sociality in arthropods on large geographic scales. Social spiders form permanent group-living societies where they cooperate in brood care, web maintenance, and foraging. Sociality has evolved independently in a number of unrelated spider genera and may reflect convergent evolutionary responses to common environmental drivers. The genus Anelosimus contains a third of approximately 25 described permanently social spider species, eight to nine species that all occur in the Americas. To test for environmental correlates of sociality in Anelosimus across the Americas, we used logistic regression to detect effects of annual rainfall, productivity, and precipitation seasonality on the relative likelihood of occurrence of social and non-social Anelosimus spiders. Our analyses show that social species tend to occur at higher annual rainfall and productivity than non-social species, supporting the hypothesised effects of these environmental variables on the geographical distribution of social species. We did not find support for the hypothesis that permanently social species occur in areas with low precipitation seasonality. High annual precipitation and, to less extent, high productivity favour the occurrence of permanently group-living Anelosimus spiders relative to subsocial and solitary species. These results are partially consistent with previous findings for the Old World spider genus Stegodyphus, where a link between high habitat productivity and sociality was also found. Unlike Anelosimus, however, Stegodyphus typically occur in dry habitats negating a general importance of high precipitation for sociality. Sociality in spiders thus seems to be strongly linked to productivity, probably reflecting the need for relatively high availability of large prey to sustain social colonies.


Environment , Social Behavior , Spiders/physiology , Americas , Animals , Logistic Models , Rain , Seasons
19.
Front Zool ; 10(1): 9, 2013 Feb 23.
Article En | MEDLINE | ID: mdl-23433065

INTRODUCTION: Sociality has evolved independently multiple times across the spider phylogeny, and despite wide taxonomic and geographical breadth the social species are characterized by a common geographical constrain to tropical and subtropical areas. Here we investigate the environmental factors that drive macro-ecological patterns in social and solitary species in a genus that shows a Mediterranean-Afro-Oriental distribution (Stegodyphus). Both selected drivers (productivity and seasonality) may affect the abundance of potential prey insects, but seasonality may further directly affect survival due to mortality caused by extreme climatic events. Based on a comprehensive dataset including information about the distribution of three independently derived social species and 13 solitary congeners we tested the hypotheses that the distribution of social Stegodyphus species relative to solitary congeners is: (1) restricted to habitats of high vegetation productivity and (2) constrained to areas with a stable climate (low precipitation seasonality). RESULTS: Using spatial logistic regression modelling and information-theoretic model selection, we show that social species occur at higher vegetation productivity than solitary, while precipitation seasonality received limited support as a predictor of social spider occurrence. An analysis of insect biomass data across the Stegodyphus distribution range confirmed that vegetation productivity is positively correlated to potential insect prey biomass. CONCLUSIONS: Habitat productivity constrains the distribution of social spiders across continents compared to their solitary congeners, with group-living in spiders being restricted to areas with relatively high vegetation productivity and insect prey biomass. As known for other taxa, permanent sociality likely evolves in response to high predation pressure and imposes within-group competition for resources. Our results suggest that group living is contingent upon productive environmental conditions where elevated prey abundance meet the increased demand for food of social groups.

...