Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Struct Heart ; 8(2): 100264, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38481712

RESUMEN

Background: Transcatheter mitral valve-in-valve (MViV) replacement has emerged as an alternative to redo mitral valve (MV) surgery for the management of failed bioprosthetic MVs. The degree of cardiac remodeling assessed by echocardiography has been shown to have prognostic implications in degenerative mitral regurgitation patients undergoing MV surgery. The impact of transcatheter MViV in patients with degenerative bioprosthetic MV failure on cardiac remodeling and its associated prognosis remains undescribed. Objectives: The aim of this study is to describe the early anatomic and functional changes of the left-sided chambers and right ventricle by echocardiography posttranscatheter MViV intervention and their impact on mortality outcomes. Additionally, we sought to analyze the outcome of heart failure in bioprosthetic MV failure patients undergoing transcatheter MViV replacement. Methods: We analyzed consecutive patients undergoing MViV intervention for symptomatic bioprosthetic MV failure. Echocardiograms before intervention and within 100 days postintervention were analyzed. A chart review was performed to obtain baseline characteristics, follow-up visits, 30-day heart failure and 1-year all-cause mortality outcomes. Results: A total of 62 patients (mean age 69 ± 13 years, 61% male) were included in the study. Most patients were undergoing MViV intervention for prosthetic mitral stenosis n = 48 (77.4%) and the rest for mitral regurgitation or mixed disease. Compared with baseline, significant reductions were observed in median left atrial volume (LAV; 103 [81-129] ml vs. 95.2 [74.5-117.5] ml, p < 0.01) and mean (SD) left atrial conduit strain (9.1% ± 5.2% vs. 10.8% ± 4.8%, p = 0.039) within 100 days postintervention. Early reduction in right ventricular free wall global longitudinal strain and fractional area change also occurred postintervention. No significant change in left ventricular chamber dimensions or ejection fraction was observed. During the 1-year follow up period, 5 (8%) patients died. While baseline LAV was not associated with 1-year all-cause mortality (OR 0.98 CI 0.95-1.01; p = 0.27), a change in LAV in the follow up period was associated with all-cause mortality at 1 year (OR 1.06 CI 1.01-1.12; p = 0.023). At 30 days postintervention, 65% of patients had an improvement in their New York Heart Association functional class. Conclusion: In this retrospective study of patients undergoing transcatheter MViV intervention for failed bioprosthetic MVs, early reverse remodeling of the left atrium occurs within 100 days postintervention and reduction in LAV is associated with reduced all-cause mortality at 1 year. In addition, there is significant improvement in heart failure symptoms at 30 days following intervention but further investigation into the longitudinal remodeling changes and long-term outcomes is needed.

2.
Magn Reson Med ; 88(1): 449-463, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35381116

RESUMEN

PURPOSE: To develop a convolutional neural network (CNN) for the robust and fast correction of velocity aliasing in 4D-flow MRI. METHODS: This study included 667 adult subjects with aortic 4D-flow MRI data with existing velocity aliasing (n = 362) and no velocity aliasing (n = 305). Additionally, 10 controls received back-to-back 4D-flow scans with systemically varied velocity-encoding sensitivity (vencs) at 60, 100, and 175 cm/s. The no-aliasing data sets were used to simulate velocity aliasing by reducing the venc to 40%-70% of the original, alongside a ground truth locating all aliased voxels (153 training, 152 testing). The 152 simulated and 362 existing aliasing data sets were used for testing and compared with a conventional velocity antialiasing algorithm. Dice scores were calculated to quantify CNN performance. For controls, the venc 175-cm/s scans were used as the ground truth and compared with the CNN-corrected venc 60 and 100 cm/s data sets RESULTS: The CNN required 176 ± 30 s to perform compared with 162 ± 14 s for the conventional algorithm. The CNN showed excellent performance for the simulated data compared with the conventional algorithm (median range of Dice scores CNN: [0.89-0.99], conventional algorithm: [0.84-0.94], p < 0.001, across all simulated vencs) and detected more aliased voxels in existing velocity aliasing data sets (median detected CNN: 159 voxels [31-605], conventional algorithm: 65 [7-417], p < 0.001). For controls, the CNN showed Dice scores of 0.98 [0.95-0.99] and 0.96 [0.87-0.99] for venc = 60 cm/s and 100 cm/s, respectively, while flow comparisons showed moderate-excellent agreement. CONCLUSION: Deep learning enabled fast and robust velocity anti-aliasing in 4D-flow MRI.


Asunto(s)
Aprendizaje Profundo , Imagenología Tridimensional , Adulto , Velocidad del Flujo Sanguíneo , Humanos , Imagen por Resonancia Magnética , Fantasmas de Imagen , Reproducibilidad de los Resultados
3.
Pulm Circ ; 10(3): 2045894020953724, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33062260

RESUMEN

Pulmonary embolism is associated with high rates of mortality and morbidity. It is important to understand direct comparisons of current interventions to differentiate favorable outcomes and complications. The objective of this study was to compare ultrasound-accelerated thrombolysis versus systemic thrombolysis versus anticoagulation alone and their effect on left ventricular outflow tract velocity time integral. This was a retrospective cohort study of subjects ≥18 years of age with a diagnosis of submassive or massive pulmonary embolism. The primary outcome was the percent change in left ventricular outflow tract velocity time integral between pre- and post-treatment echocardiograms. Ultrasound-accelerated thrombolysis compared to anticoagulation had a greater improvement in left ventricular outflow tract velocity time integral, measured by percent change. No significant change was noted between the ultrasound-accelerated thrombolysis and systemic thrombolysis nor systemic thrombolysis and anticoagulation groups. Pulmonary artery systolic pressure only showed a significant reduction in the ultrasound-accelerated thrombolysis versus anticoagulation group. The percent change of right ventricular to left ventricular ratios was improved when systemic thrombolysis was compared to both ultrasound-accelerated thrombolysis and anticoagulation. In this retrospective study of submassive or massive pulmonary embolisms, left ventricular outflow tract velocity time integral demonstrated greater improvement in patients treated with ultrasound-accelerated thrombolysis as compared to anticoagulation alone, a finding not seen with systemic thrombolysis. While this improvement in left ventricular outflow tract velocity time integral parallels the trend seen in mortality outcomes across the three groups, it only correlates with changes seen in pulmonary artery systolic pressure, not in other markers of echocardiographic right ventricular dysfunction (tricuspid annular plane systolic excursion and right ventricular to left ventricular ratios). Changes in left ventricular outflow tract velocity time integral, rather than echocardiographic markers of right ventricular dysfunction, may be considered a more useful prognostic marker of both dysfunction and improvement after reperfusion therapy.

4.
Magn Reson Med ; 84(4): 2204-2218, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32167203

RESUMEN

PURPOSE: To generate fully automated and fast 4D-flow MRI-based 3D segmentations of the aorta using deep learning for reproducible quantification of aortic flow, peak velocity, and dimensions. METHODS: A total of 1018 subjects with aortic 4D-flow MRI (528 with bicuspid aortic valve, 376 with tricuspid aortic valve and aortic dilation, 114 healthy controls) comprised the data set. A convolutional neural network was trained to generate 3D aortic segmentations from 4D-flow data. Manual segmentations served as the ground truth (N = 499 training, N = 101 validation, N = 418 testing). Dice scores, Hausdorff distance, and average symmetrical surface distance were calculated to assess performance. Aortic flow, peak velocity, and lumen dimensions were quantified at the ascending, arch, and descending aorta and compared using Bland-Altman analysis. Interobserver variability of manual analysis was assessed on a subset of 40. RESULTS: Convolutional neural network segmentation required 0.438 ± 0.355 seconds versus 630 ± 254 seconds for manual analysis and demonstrated excellent performance with a median Dice score of 0.951 (0.930-0.966), Hausdorff distance of 2.80 (2.13-4.35), and average symmetrical surface distance of 0.176 (0.119-0.290). Excellent agreement was found for flow, peak velocity, and dimensions with low bias and limits of agreement less than 10% difference versus manual analysis. For aortic volume, limits of agreement were moderate within 16.3%. Interobserver variability (median Dice score: 0.950; Hausdorff distance: 2.45; and average symmetrical surface distance: 0.145) and convolutional neural network-based analysis (median Dice score: 0.953-0.959; Hausdorff distance: 2.24-2.91; and average symmetrical surface distance: 0.145-1.98 to observers) demonstrated similar reproducibility. CONCLUSIONS: Deep learning enabled fast and automated 3D aortic segmentation from 4D-flow MRI, demonstrating its potential for efficient clinical workflows. Future studies should investigate its utility for other vasculature and multivendor applications.


Asunto(s)
Aprendizaje Profundo , Aorta/diagnóstico por imagen , Hemodinámica , Humanos , Imagen por Resonancia Magnética , Reproducibilidad de los Resultados
5.
Radiology ; 293(3): 541-550, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31592729

RESUMEN

Background Four-dimensional (4D) flow MRI enables the evaluation of blood flow alterations in patients with congenital bicuspid aortic valve (BAV). However, current analysis methods are cumbersome and lack the use of the volumetric data from 4D MRI. Purpose To investigate the feasibility and reproducibility of a technique that uses a catheter-like mathematical model (virtual catheter) to assess volumetric intra-aortic hemodynamics from 4D flow MRI in patients with BAV. Materials and Methods In this retrospective study, data were collected from adult patients with BAV and healthy participants who underwent aortic 4D flow MRI from November 2011 through August 2014. Reproducibility was tested in healthy study participants who underwent test-retest examinations within 2 weeks. Patients were grouped on the basis of the severity of aortic valve regurgitation (AVR) and aortic valve stenosis (AVS). A 4D virtual catheter mathematical model for probing intra-aortic hemodynamic flow was constructed as a tube with an automatically derived radius along the entire thoracic aorta centerline. Volumetric intra-aortic hemodynamics were computed from 4D flow MRI only within the virtual catheter, and the following volume-normalized systolic peaks were derived: kinetic energy (KE), viscous energy loss rate (VELR), and vorticity. Hemodynamic data were presented as medians with interquartile ranges and compared by using Mann-Whitney U test and Kruskal-Wallis test. Results The study included 91 participants (57 patients [mean age, 46 years ± 12], 18 women; 34 healthy participants [mean age: 44 years ± 14], 12 women; 15 healthy participants underwent test-retest examinations). Patients showed higher VELR values compared with healthy participants (median, 31 W/m3 [interquartile range, 21-72] vs 23 W/m3 [interquartile range, 17-30], respectively; P < .001) and vorticity (69 sec-1 [interquartile range, 59-87] vs 60 sec-1 [interquartile range, 50-67], respectively; P < .001). Four-dimensional virtual catheter showed differences among different AVS and AVR grades with the highest VELR (120 W/m3; interquartile range, 99-166; P < .001) and vorticity (108 sec-1; interquartile range, 84-151; P < .001) found in severe AVS. High test-retest reproducibility was found for all virtual catheter-derived metrics (intraclass correlation, 0.80 ± 0.07; coefficient of variation, 9% ± 3). Conclusion The proposed four-dimensional (4D) virtual catheter technique enabled reproducible automated evaluation of volumetric intra-aortic hemodynamics alterations from 4D flow MRI in patients with bicuspid aortic valve. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Mitsouras and Hope in this issue.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/fisiopatología , Hemodinámica , Imagen por Resonancia Magnética/métodos , Adulto , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Interfaz Usuario-Computador , Viscosidad
6.
Int J Cardiovasc Imaging ; 35(10): 1925-1934, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31144256

RESUMEN

Bicuspid aortic valve (BAV) is associated with abnormal valve-mediated hemodynamics including high velocity jets and elevated wall shear stress (WSS). This study investigated interval changes in flow and WSS in a multi-year follow-up study. This cross-sectional study included n = 44 patients with BAV (age = 44.9 ± 12 years), n = 17 patients with tricuspid aortic valve and thoracic aortic dilatation (TAV with dilation, age = 54.6 ± 16.5 years), and n = 9 healthy controls (age = 49.3 ± 14.7 years) underwent baseline and serial aortic 4D flow MRI (follow-up duration: BAV: 2.6 ± 0.7 years, TAV with dilation: 2.7 ± 0.5 years, controls: 1.1 ± 0.5 years). Data analysis included quantification of aortic dimensions, peak systolic velocities, as well as regional 3D WSS in the ascending aorta. At baseline, BAV patients demonstrated uniformly elevated peak velocity and WSS compared to TAV with dilation and control groups (peak velocity 2.2 m/s vs. 1.6 m/s vs. 1.5 m/s, p < 0.004; WSS: 0.74 Pa vs. 0.45 Pa vs. 0.55 Pa, p < 0.001). For BAV, peak velocity increased from baseline to follow up (2.2 ± 0.8 to 2.3 ± 0.9 m/s, p < 0.001) while WSS decreased (0.74 ± 0.22 to 0.65 ± 0.21 Pa, p < 0.001). Aortic growth was minimal for both BAV (0.05 cm/year) and TAV with dilation (0.03-0.04 cm/year) patients. For BAV patients, increase of ascending aorta peak velocities indicated worsening of valve function at follow-up. Compared to TAV with dilation patients, BAV patients demonstrated a reduction in WSS which may indicate a compensatory mechanism to reduce elevated WSS forces by aortic remodeling.


Asunto(s)
Aorta/diagnóstico por imagen , Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Hemodinámica , Angiografía por Resonancia Magnética , Imagen por Resonancia Cinemagnética , Adulto , Anciano , Aorta/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide , Velocidad del Flujo Sanguíneo , Estudios Transversales , Dilatación Patológica , Progresión de la Enfermedad , Femenino , Enfermedades de las Válvulas Cardíacas/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Estrés Mecánico , Factores de Tiempo , Remodelación Vascular
8.
Front Physiol ; 8: 475, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28740468

RESUMEN

Bicuspid aortic valve (BAV) is a common congenital cardiac malformation affecting 1-2% of people. BAV results from fusion of two adjacent aortic valve cusps, and is associated with dilatation of the aorta, known as bicuspid valve associated aortopathy. Bicuspid valve aortopathy is progressive and associated with catastrophic clinical events, such as aortic dissection and rupture. Therefore, frequent monitoring and early intervention with prophylactic surgical resection of the proximal aorta is often recommended. However, the specific pattern of aortopathy is highly variable among patients, with different segments of the ascending aorta being affected. Individual patient risks are sometimes difficult to predict. Resection strategies are informed by current surgical guidelines which are primarily based on aortic size and growth criteria. These criteria may not optimally reflect the risk of important aortic events. To address these issues in the care of patients with bicuspid valve aortopathy, our translational research group has focused on validating use of novel imaging techniques to establish non-invasive hemodynamic biomarkers for risk-stratifying BAV patients. In this article, we review recent efforts, successes, and ongoing challenges in the development of more precise and individualized surgical approaches for patients with bicuspid aortic valves and associated aortic disease.

9.
J Vasc Interv Radiol ; 27(5): 723-729.e1, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-27106646

RESUMEN

The AngioVac device (AngioDynamics, Inc, Queensbury, New York), a commercially available large-diameter aspiration cannula using extracorporeal venovenous bypass, is designed to facilitate en bloc mechanical thrombectomy of massive thrombi of the central vasculature. Between February 2014 and January 2015, seven consecutive patients, each presenting with large central thrombi of the iliac veins, vena cava, right atrium, or pulmonary artery, underwent thrombectomy. Partial or complete clot abatement was achieved in all instances. All patients survived the procedure. One case was complicated by embolization of septic thrombi. At most recent follow-up, one patient had died of causes unrelated to venous thrombosis; all other patients were living (median follow-up time 8 mo). Several technical and therapeutic insights were gained from our center's early experience.


Asunto(s)
Circulación Extracorporea/instrumentación , Cardiopatías/terapia , Embolia Pulmonar/terapia , Trombectomía/instrumentación , Dispositivos de Acceso Vascular , Tromboembolia Venosa/terapia , Trombosis de la Vena/terapia , Adulto , Anciano , Chicago , Angiografía por Tomografía Computarizada , Diseño de Equipo , Circulación Extracorporea/efectos adversos , Circulación Extracorporea/métodos , Femenino , Atrios Cardíacos/diagnóstico por imagen , Cardiopatías/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Flebografía/métodos , Embolia Pulmonar/diagnóstico por imagen , Radiografía Intervencional , Estudios Retrospectivos , Trombectomía/efectos adversos , Trombectomía/métodos , Resultado del Tratamiento , Tromboembolia Venosa/diagnóstico por imagen , Trombosis de la Vena/diagnóstico por imagen
10.
J Magn Reson Imaging ; 40(6): 1342-6, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24265266

RESUMEN

PURPOSE: To assess the impact of aortic valve morphology on aortic hemodynamics between normal tricuspid and congenitally anomalous aortic valves ranging from unicuspid to quadricuspid morphology. MATERIALS AND METHODS: Aortic three-dimensional (3D) blood flow was evaluated by 4D flow MRI in 14 healthy volunteers with normal trileaflet valves and 14 patients with unicuspid (n = 3), bicuspid (n = 9, 3 "true" bicuspid, 3 right-left (RL), 3 right-noncoronary (RN) leaflet fusion, and quadricuspid aortic valves (n = 2). Data analysis included the co-registered visualization of aortic valve morphology with systolic 3D blood flow. The influence of valve morphology on aortic hemodynamics was quantified by valve flow angle. RESULTS: All RL-bicuspid aortic valve (BAV) were associated with flow jets directed toward the right anterior aortic wall while RN-fusion and unicuspid valves resulted in flow jet patterns toward the right-posterior or posterior wall. Flow angles were clearly influenced by valve morphology (47° ± 10, 28° ± 2, 29° ± 18, 18° ± 12, 15° ± 2 for unicuspid, true BAV, RN-BAV, RL-BAV, quadricuspid valves) and increased compared with controls (7.2° ± 1.1, P = 0.001). CONCLUSION: Altered 3D aortic hemodynamics are impacted by the morphology of congenitally malformed aortic valves.


Asunto(s)
Válvula Aórtica/anomalías , Válvula Aórtica/patología , Válvula Aórtica/fisiopatología , Velocidad del Flujo Sanguíneo , Enfermedades de las Válvulas Cardíacas/patología , Enfermedades de las Válvulas Cardíacas/fisiopatología , Imagenología Tridimensional/métodos , Angiografía por Resonancia Magnética/métodos , Adulto , Enfermedad de la Válvula Aórtica Bicúspide , Estudios de Cohortes , Femenino , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Masculino , Imagen Multimodal/métodos , Imagen de Perfusión Miocárdica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Técnica de Sustracción , Adulto Joven
11.
ASAIO J ; 57(4): 254-61, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21546824

RESUMEN

There is a paucity of literature describing the outcomes associated with the use of TandemHeart percutaneous ventricular assist device (PVAD). The literature is limited by analyzing only subsets of patients. We present the clinical outcomes and safety associated with the use of TandemHeart among a series of heterogeneous patients requiring PVAD support. We reviewed the clinical experience, hemodynamic variables, survival outcomes, and complications associated with the implantation of TandemHeart support device among 25 patients presenting to our institution. Indications for PVAD implantation were cardiogenic shock (56%), ST-segment elevation myocardial infarction (STEMI) (20%), postpericardiotomy (16%), and high-risk percutaneous coronary interventions (PCI) or ventricular tachycardia (VT) ablation (8%). TandemHeart was used for an average of 4.8 ± 2.1 days and demonstrated significant hemodynamic improvements (pre- and postimplantation left ventricular ejection fractions were 21.5% ± 15% and 24.5% ± 10.5%, respectively [p = 0.06]). The cardiac index improved from a mean 2.04 ± 075 L/min/m² to 2.45 ± 073 L/min/m² (p = 0.09). The mixed venous oxygen saturation (SVO2) increased from 55.14 ± 13.34 to 66.43 ± 7.43 (p = 0.008) after implantation. TandemHeart was used as a bridge to left ventricular assist device implantation (44%) or recovery (20%). Thirty-six percent of patients died on support or shortly after PVAD removal. Thirty, 90-day, and long-term (>90 days) survival rates were 56%, 52%, and 36%, respectively. Procedure-related complications were reported in 13 patients (56%), and the majority (90%) was related to vascular access (bleeding or pseudoaneurysm). The TandemHeart device is a safe therapeutic option as a bridge-to-recovery or bridge-to-bridge for patients with hemodynamic compromise regardless of the etiology. The favorable hemodynamic profile, postimplantation survival rates, and manageable complications support its use to assist hemodynamic recovery in patients refractory to conventional therapy.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Corazón Auxiliar , Adulto , Anciano , Femenino , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Modelos Biológicos , Infarto del Miocardio/patología , Oxígeno/metabolismo , Sistema de Registros , Choque Cardiogénico/cirugía , Resultado del Tratamiento
12.
Ann Thorac Surg ; 91(2): 602-3, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21256327

RESUMEN

Cardiac hemangiomas are extremely rare benign vascular tumors of the heart. We present the unusual case of a 60-year-old man with a large cavernous hemangioma involving the left ventricular apex. The tumor was completely excised under cardiopulmonary bypass. The pertinent literature is reviewed and the technical steps, clinical presentation, and histopathologic findings are discussed.


Asunto(s)
Neoplasias Cardíacas/cirugía , Ventrículos Cardíacos/cirugía , Hemangioma Cavernoso/cirugía , Ecocardiografía , Neoplasias Cardíacas/diagnóstico , Neoplasias Cardíacas/patología , Tabiques Cardíacos/cirugía , Hemangioma Cavernoso/diagnóstico , Hemangioma Cavernoso/patología , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Invasividad Neoplásica , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...