Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Ophthalmic Surg Lasers Imaging Retina ; 53(5): 249-256, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35575736

RESUMEN

OBJECTIVE: To describe the Port Delivery System with ranibizumab implant insertion procedure. METHODS: A surgical procedure based on the clinical trial program in patients with retinal diseases. RESULTS: An infusion line is placed in the infero-temporal quadrant; a superotemporal quadrant corneal traction suture is recommended. The superotemporal quadrant peritomy of 6 × 6 mm is executed with gentle, purposeful tissue handling. Generous posterior and lateral sub-Tenon's capsule dissection creates laxity for the subsequent closure. Adequate scleral hemostasis is achieved with wet-field cautery to maintain a clean field. The implant is filled under magnification with a customized formulation of ranibizumab. A precise 3.5-mm-long scleral incision (4 mm posterior and parallel to the limbus) is created to ensure proper implant fit. The exposed pars plana undergoes laser ablation to reduce vitreous hemorrhage risk. A pars plana incision is made, and the implant is inserted perpendicular to the globe and seated flush against the sclera. Complete closure of both the conjunctiva and Tenon's capsule with scleral anchoring and mild tissue overhang at the anterior limbus is performed to reduce conjunctival erosion and retraction risks. CONCLUSION: The procedure is straightforward yet requires precise preoperative and intraoperative preparation and standardized surgical techniques. [Ophthalmic Surg Lasers Imaging Retina. 2022;53:249-256.].


Asunto(s)
Ranibizumab , Esclerótica , Conjuntiva/cirugía , Humanos , Esclerótica/cirugía , Suturas , Hemorragia Vítrea
2.
Ophthalmic Surg Lasers Imaging Retina ; 53(5): 266-273, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35575739

RESUMEN

OBJECTIVES: To describe conjunctiva and Tenon's capsule handling during the Port Delivery System with ranibizumab (PDS) implant insertion procedure including up-front assessments, planning, and instrumentation, with emphasis placed on the peritomy, scleral dissection, and closure steps. METHODS: Surgical pearls based on experience accumulated in the PDS clinical trial program in patients with retinal diseases. RESULTS: Preoperative preparation, specific instruments, and meticulous techniques are key to optimizing surgical outcomes. Before surgery, assessment of factors that affect conjunctival integrity and an in-office conjunctiva examination are conducted. Gentle, purposeful conjunctiva and Tenon's capsule handling with nontoothed forceps and suturing with a BV needle are recommended to prevent tissue damage. The peritomy is 6 mm by 6 mm, centered around the planned implant location in the superotemporal quadrant. A complete sub-Tenon's capsule dissection is achieved using a wide, robust lateral and posterior dissection technique to free tissue from the sclera and minimize tension. The globe is stabilized during scleral cutdown by grasping the sclera with fine-toothed forceps away from the incision edge to prevent tissue delamination. When closing the peritomy, both the conjunctiva and Tenon's capsule are completely captured and sutured with scleral anchoring at the apex of the peritomy to help prevent conjunctival retraction and erosion. Mitigation and detection of adverse events is critical to successful surgical outcomes. CONCLUSIONS: The PDS implant insertion procedure is straightforward, but it requires planned preoperative preparation, specific instruments, and meticulous techniques. The surgical pearls described here offer insights for optimizing outcomes. [Ophthalmic Surg Lasers Imaging Retina. 2022;53:266-273.].


Asunto(s)
Ranibizumab , Cápsula de Tenon , Conjuntiva/cirugía , Humanos , Esclerótica/cirugía , Colgajos Quirúrgicos , Cápsula de Tenon/cirugía
3.
Ophthalmic Surg Lasers Imaging Retina ; 53(5): 257-265, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35575741

RESUMEN

PURPOSE: To describe the Port Delivery System with ranibizumab refill-exchange procedure. METHODS: Procedure based on the clinical trial program in patients with retinal diseases. RESULTS: The refill-exchange procedure is performed under topical anesthesia and strict aseptic conditions. Supplemental task lighting and magnification are recommended throughout the procedure. Ranibizumab is aseptically transferred from the vial with the filter needle and air is removed from the syringe. The filter needle is then replaced with the refill needle; any remaining air is removed from the syringe and the plunger is advanced to the 0.1-mL mark. Targeting the implant septum center, the refill needle is inserted perpendicularly to the globe until the soft stop contacts the conjunctiva (perpendicular orientation and conjunctival contact are maintained throughout the procedure); a cotton-tipped applicator is recommended for globe stabilization. The entire syringe contents are slowly injected over 5-10 seconds while existing solution fills the fluid collection reservoir. Once completed, the needle is carefully withdrawn while maintaining perpendicularity. The procedure can be successfully performed in rare, specific cases, including subconjunctival thickening or fibrous capsule formation, fluid-filled bleb formation, and corneal patch grafts. CONCLUSION: The procedure is straightforward but distinct from intravitreal injections and requires adherence to standardized techniques. With appropriate preparation, the procedure can be performed in specific cases. [Ophthalmic Surg Lasers Imaging Retina. 2022;53:257-265.].


Asunto(s)
Ranibizumab , Enfermedades de la Retina , Inhibidores de la Angiogénesis , Sistemas de Liberación de Medicamentos , Humanos , Inyecciones Intravítreas , Jeringas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA