Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
3.
Bioanalysis ; 4(7): 763-8, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22512795

RESUMEN

The Global CRO Council for Bioanalysis (GCC) was formed in September 2010. Since then, the representatives of the member companies come together periodically to openly discuss bioanalysis and the regulatory challenges unique to the outsourcing industry. The 4th GCC Closed Forum brought together experts from bioanalytical CROs to share and discuss recent issues in regulated bioanalysis, such as the impact of coadministered drugs on stability, some differences between European Medicines Agency and US FDA bioanalytical guidance documents and lessons learned following recent Untitled Letters. Recent 483s and agency findings, as well as issues on method carryover, were also part of the topics discussed.


Asunto(s)
Técnicas de Química Analítica/normas , Guías como Asunto , Organizaciones sin Fines de Lucro/normas , United States Food and Drug Administration/normas , Métodos Analíticos de la Preparación de la Muestra , Calibración , Química Farmacéutica , Documentación , Combinación de Medicamentos , Estabilidad de Medicamentos , Europa (Continente) , Estándares de Referencia , Reproducibilidad de los Resultados , Estados Unidos
4.
J Pharm Sci ; 100(11): 4655-63, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21780117

RESUMEN

Alzheimer's disease is the leading cause of human dementia. The lack of diagnostic tests and limited therapeutic options has driven the search for endogenous biomarkers. The INNO-BIA AlzBio3 assay is a multiplex flow-based immunoassay measuring Aß42, tau, and p-tau in cerebrospinal fluid (CSF). This study assesses assays performance under varying bead count (BC) parameters. Original method validation parameters at 100 BC were acceptable. Reanalyses performed at 3, 10, 25, and 50 BCs were compared to 100 BC data by ANOVA, Bland-Altman analysis, evaluation of concordance correlation coefficients, and frequency distribution of coefficient of variation (CV) ranges. Method validation characteristics were acceptable with 100 BCs. Equivalency for 25 and 50 versus 100 BCs was demonstrated, but not for 3 and 10 BCs. A general trend of decreasing agreement between decreasing BCs and the 100 BC reference resulted in decreases in concordance coefficients ρ(c) . The frequency of CV values greater than 20% increased with decreasing BCs, and CV values of 5% or less decreased with decreased BCs. Statistical analyses demonstrate that BCs of 3 and 10 are not equivalent with the reference and should not be used as a basis for determination of Aß42, tau, and p-tau concentration in human CSF.


Asunto(s)
Péptidos beta-Amiloides/líquido cefalorraquídeo , Fragmentos de Péptidos/líquido cefalorraquídeo , Proteínas tau/líquido cefalorraquídeo , Enfermedad de Alzheimer/líquido cefalorraquídeo , Humanos , Inmunoensayo , Fosforilación , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...