Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Vojnosanit Pregl ; 72(6): 557-60, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26226731

RESUMEN

INTRODUCTION: Transcatheter atrial septal defect (ASD) closure is considered to be a gold standard for patients with the suitable anatomy as compared to cardiac surgery. Reocurrence of ASD after surgical closure is a very rare late complication which can be successfully managed with transcatheter procedure. CASE REPORT: We reported a female patient with Noonan syndrome who presented with hemodinamically significant ASD 37 years after the corrective cardiac surgery. Due to numerous comorbidities which included severe kyphoscoliosis, pectus excavatum and multiple surgeries we decided to perform transcatheter closure of ASD. The procedure itself was very challenging due to the patient's short stature and heart's orientation in the chest, but was performed successfully. The subsequent follow-up was uneventful and the patient reported improvement in the symptoms. CONCLUSION: Transcatheter closure of ASD in a patient with Noonan syndrome with the history of surgically corrected ASD can be performed successfully, despite challenging chest anatomy.


Asunto(s)
Defectos del Tabique Interatrial/cirugía , Síndrome de Noonan/complicaciones , Adulto , Cateterismo Cardíaco , Procedimientos Quirúrgicos Cardíacos/métodos , Femenino , Humanos
2.
Vojnosanit Pregl ; 72(1): 68-71, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26043595

RESUMEN

INTRODUCTION: Acquired ventricular septal defect (VSD) is uncommon, but serious mechanical complication of acute myocardial infarction with poor outcome and high mortality rate in surgically or medically treated patients. CASE REPORT: We report a 58-year-old male patient admitted to our hospital six days following acute inferior myocardial infarction complicated by ventricular septal rupture with signs of heart failure. Coronary angiography revealed 3-vessel disease, with proximally occluded dominant right coronary artery. Transthoracic echo exam revealed aneurysm of a very thin inferior septum and the basal portion of the inferior left ventricular wall, with septal wall rupture. One of the VSD dimensions was 15 mm and left- to right shunt was calculated 2:1. Since the patient was at too high risk for surgical closure, transcatheter closure of VSD was chosen as a better option. Under short intravenous sedation, 24 mm Am- platzer device was implanted percutaneously with transesophageal echo guidance. The post-procedural result revealed a small residual shunt, but it was followed by significant improvement of the patient's clinical status. A 24h Holter ECG monitoring did not show cardiac rhythm or conduction disturbances. Coronary angiography was repeated ten days following the procedure, after hemodynamic stabilization of the patient, with direct stenting of the circumflex artery and the intermediate artery. Ostial left descending artery lesion was left for further functional significance assessment. CONCLUSION: Percutaneous closure with a septal occluder device can be definitive primary treatment for anatomically suitable patients or it can serve as a bridge to surgical treatment.


Asunto(s)
Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/cirugía , Rotura Cardíaca/etiología , Rotura Cardíaca/cirugía , Defectos del Tabique Interventricular/etiología , Defectos del Tabique Interventricular/cirugía , Infarto del Miocardio/complicaciones , Intervención Coronaria Percutánea , Angiografía Coronaria , Ecocardiografía , Electrocardiografía Ambulatoria , Humanos , Masculino , Persona de Mediana Edad , Dispositivo Oclusor Septal
3.
Catheter Cardiovasc Interv ; 72(7): 901-8, 2008 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-19016466

RESUMEN

OBJECTIVES: The aim of this study was to assess the pharmacokinetics and tolerability of Biolimus A9 eluted from Nobori coronary stents. BACKGROUND: : The release kinetics and pharmacokinetics of drugs delivered via coronary stents have been shown to play an essential role in the efficacy and safety of drug eluting stents. METHODS: Twenty patients with coronary artery disease were treated with single 14-mm (10 patients) or 28-mm long stent (10 patients). Blood samples were drawn at 16 time points to determine the pharmacokinetics of Biolimus A9. At seven time points, complete laboratory and toxicology panels were assessed to screen for potential Biolimus A9 toxicity. The primary endpoint of the study was the systemic blood concentrations of Biolimus A9 after 28 days and 6 months as measured using highly specific and sensitive liquid chromatography- tandem mass spectrometry assay. RESULTS: At 28 days, 6 patients (30%) had quantifiable Biolimus A9 concentrations in blood. The highest Biolimus A9 blood concentration measured in any sample was 32.2 pg/mL. The median time to maximum concentration was 2 hr, ranging from 0.05 hr to 3 months. Six months after stent implantation, only 1 of 20 patients had measurable Biolimus A9 concentrations at the lowest level of quantification, while at 9 months no sample had quantifiable Biolimus A9 concentrations. Laboratory and toxicology assessments did not indicate any impact of Biolimus A9 on the evaluated parameters. CONCLUSION: Results of this study suggest that systemic exposure to Biolimus A9 was very low and that Biolimus A9 was well tolerated.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Fármacos Cardiovasculares/farmacocinética , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Sirolimus/análogos & derivados , Fármacos Cardiovasculares/administración & dosificación , Fármacos Cardiovasculares/efectos adversos , Fármacos Cardiovasculares/sangre , Cromatografía Liquida , Colorado , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Serbia , Sirolimus/administración & dosificación , Sirolimus/efectos adversos , Sirolimus/sangre , Sirolimus/farmacocinética , Espectrometría de Masas en Tándem , Resultado del Tratamiento
4.
EuroIntervention ; 3(5): 574-9, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19608483

RESUMEN

AIM: To compare clinical efficacy and safety of stents eluting limus drugs from biodegradable polymer - Nobori, or durable polymer - Cypher. METHODS AND RESULTS: From May to August 2006, 107 patients with 142 coronary artery lesions were treated with either Nobori, Biolimus A9 eluting stent (54) or Cypher, Sirolimus eluting stent (53) in five centres. The two groups were well matched for baseline clinical and angiographic characteristics. The in-stent late loss at nine months, the primary endpoint of the study, was 0.10+/-0.26 mm in Nobori, and 0.13+/-0.44 mm in Cypher arm (p=0.660) confirming the hypothesis of the similarity between the two stents. In-stent diameter stenosis of 13+/-10% with Nobori was significantly lower than 20+/-12% with Cypher stent (p=0.002) without significant difference in binary restenosis (1.7% in Nobori and 6.3% in Cypher arm; p=0.32). The rate of major adverse cardiac events at 12 months was 1.9% with Nobori and 4.1% with Cypher stent. CONCLUSIONS: The nine months angiographic data from Nobori Core study demonstrate that Biolimus A9 has similar anti-proliferative efficacy to Sirolimus as judged by in-stent late loss and restenosis rate. Low frequency of adverse cardiac events at 12 months indicates that both stents are safe and effective in the studied population.

5.
Ann Thorac Surg ; 78(3): 1078-80, 2004 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-15337056

RESUMEN

Radial artery segment has been used as a coronary-coronary graft for single, distal lesion of the large left anterior descending coronary artery running well over the cardiac apex. In our opinion this technique may occasionally be an attractive approach for bypassing very distal lesions of large coronary arteries combined with regular arterial or venous grafting of the target artery if proximal stenosis is also present. The remnant of the radial artery can be used for grafting of another diseased artery (eg, the large first marginal branch of the circumflex artery in our case report).


Asunto(s)
Enfermedad Coronaria/cirugía , Arteria Radial/trasplante , Angiografía Coronaria , Puente de Arteria Coronaria/métodos , Enfermedad Coronaria/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad
6.
Med Pregl ; 57(11-12): 601-4, 2004.
Artículo en Serbio | MEDLINE | ID: mdl-16107010

RESUMEN

INTRODUCTION: Nowadays, coronary-coronary bypass grafting (CCBG) has been applied in patients with heavily calcified ascending aorta or due to lack of graft material. CASE REPORT: We describe a case in which the patient's large left anterior descending (LAD) coronary artery, running well over the cardiac apex, presented with proximal and distal stenosis. Although the pedicled left internal thoracic artery (ITA) graft is sometimes too short for sequential bypass in cases of distal stenosis of the LAD coronary artery, we used a free, short segment of the pedicled left ITA for coronary-coronary bypass grafting. The in situ remnant of the left pedicled ITA was used to bypass the proximal LAD stenosis. The patient's postoperative course was uneventful. Predischarge angiogram (on the 9th postoperative day) showed an in situ left ITA graft as well as afree coronarycoronary ITA graft. The patient had a regularfollow-up after 3 months, and was classified as New York Heart Association (NYHA) class I. DISCUSSION: Primarily used in aorto-coronary bypass surgery (termino-terminal interposition of the saphenous vein between two parts of a resected coronary artery), CCBG was revised latter on, and from hemodynamic point of view the physiologic restoration of coronary blood flow has been confirmed CCBG might be an attractive approach for bypassing distal lesions of large coronary arteries (combined with arterial or venous grafting of targeted arteries, if proximal stenoses are also present). The proximal remnant of ITA can be used as an in situ or free graft.


Asunto(s)
Puente de Arteria Coronaria/métodos , Humanos , Anastomosis Interna Mamario-Coronaria , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...