RESUMEN
BACKGROUND: Few studies have compared the Pipeline Shield stents with previous generations of flow-diverting stents (FDSs) for the treatment of unruptured intracranial aneurysms. This study aimed to evaluate the efficacy and safety of Pipeline Shield stents and FDSs without modified surfaces. METHODS: The present evaluation is a retrospective cohort study of patients endovascularly treated with Pipeline Shield stents or FDSs without modified surfaces for unruptured intracranial aneurysms between January 2014 and June 2022. The data analyzed were obtained from the anonymized database of our institution's interventional radiology service. RESULTS: A total of 147 patients with 155 unruptured intracranial aneurysms were included. Of the 155 aneurysms, 96 were treated with Pipeline Shield stents and 59 with FDSs without modified surfaces. The aneurysms treated with Pipeline Shield stents had higher 6-month (O'Kelly-Marotta [OKM] D; 87.5% vs. 71.4%; P = 0.025) and 1-year (OKM D; 82.5% vs. 63.0%; P = 0.047) occlusion rates than the aneurysms treated using FDSs without modified surfaces. No differences between the devices were found at the 1-year follow-up in the incidence of ischemic stroke (P = 0.939) or hemorrhagic complications (P = 0.559). CONCLUSIONS: Pipeline Shield stents demonstrated superior complete occlusion rates (OKM D) at both the 6-month and the 1-year follow-up assessments compared with nonmodified surface FDSs. No significant differences were found in the safety profiles between the 2 types of stents with regard to thromboembolic complications and ischemic events. Further research with larger study populations is necessary to validate these findings.
Asunto(s)
Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Humanos , Aneurisma Intracraneal/complicaciones , Estudios Retrospectivos , Resultado del Tratamiento , Stents/efectos adversosRESUMEN
INTRODUCTION: Intracranial aneurysms (IA) are a focal dilatation of the vessel wall, the rupture of these, causes subarachnoid hemorrhage. Until now, endovascular management is the ideal treatment, providing the interventionist a range of options among which the stent and coils embolization stands out because of its occlusion rate. This study presents the results of a retrospective cohort comparing the effectiveness, morbidity, and mortality of IA treatment with laser-cut stent-assisted coils versus braided stents. METHODOLOGY: Retrospective cohort of patients diagnosed with unruptured intracranial aneurysms treated with coil-assisted laser-cut stents or braided stents between January 2014 and December 2021. RESULTS: In total, 138 patients with 147 intracranial aneurysms were analyzed, 91 of them were treated with laser-cut stent and 56 with braided stents. The main antecedent was arterial hypertension (48.55%). In the immediate angiographic control, a Raymond Roy scale (RRO) I was obtained in 86.81% of the patients with laser-cut stents and 87.50% of the patients with braided stents. In the angiographic follow-up at 12 months, an RRO I occlusion rate of 85.19% was reported in both groups. Perioperative complications occur in 16 patients treated with laser-cut stents and 12 patients treated with braided stents. Three patients presented bleeding complications during the 12-month follow-up, of which two correspond to patients treated with braided stents and one with a laser-cut stent. CONCLUSION: Treatment of patients with intracranial aneurysms with laser-cut stents or braided stents and coils is just as safe and effective.