1.
J Cardiovasc Electrophysiol ; 34(3): 718-725, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36738153

RESUMEN

INTRODUCTION: Left bundle branch area pacing (LBBAP) is achieved by advancing the lead tip deep in the septum. Most LBBAP implants are performed using the Medtronic SelectSecure™ MRI SecureScan™ Model 3830 featuring a unique 4 Fr fixed helix lumenless design. Details of lead use conditions and long-term reliability have not been reported. This study was designed to quantify the mechanical use conditions for the 3830 lead during and after LBBAP implant, and to evaluate reliability using bench testing and simulation. METHODS: Fifty bradycardia patients with implantation of the 3830 lead for LBBAP were enrolled. Use conditions of lead deployment at implantation were collected and computed tomography (CT) scans were performed at 3-month follow-up. Curvature amplitude along the pacing lead was determined with CT images. Fatigue bending was performed using accelerated testing in a more severe environment than routine clinical use conditions. Conductor fracture rate in a simulated patient population was estimated based on clinical use conditions and fatigue test results. RESULTS: The number of attempts to place the 3830 lead for LBBAP was 2.1 ± 1.3 (range: 1-7) with 13 ± 6 lead rotations at the final attempt. Extreme implant conditions were simulated in bench testing with 5 applications of 20 turns followed by up to 400 million bending cycles. Reliability modeling predicted a 10-year fracture rate of 0.02%. CONCLUSIONS: LBBAP implants require more lead rotations than standard pacing implants and result in unique lead bending. Application of simulated LBBAP use conditions to the 3830 lead in an accelerated in-vitro model does not produce excess conductor fractures. IMAGE-LBBP Study ID of ClinicalTrial.GOV: NCT04119323.


Asunto(s)
Marcapaso Artificial , Humanos , Fascículo Atrioventricular , Bloqueo de Rama/terapia , Estimulación Cardíaca Artificial/métodos , Electrocardiografía/métodos , Reproducibilidad de los Resultados
2.
J Cardiovasc Electrophysiol ; 33(6): 1244-1254, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35419908

RESUMEN

INTRODUCTION: Left bundle branch area pacing (LBBAP) is a novel physiological pacing modality. The relationship between the pacing lead tip location and paced electrocardiographic (ECG) characteristics remains unclear. The objectives are to determine the lead tip location within the interventricular septum (IVS) and assess the location-based ECG QRS duration (QRSd) and left ventricular activation time (LVAT). METHODS: This multicenter study enrolled 50 consecutive bradycardia patients who met pacemaker therapy guidelines and received LBBAP implantation via the trans-ventricular septal approach. After at least 3 months postimplant, 12-lead ECGs and pacing parameters were obtained. Cardiac computed tomography (CT) imaging was performed to assess the LBBAP lead tip distance from the LV blood pool. RESULTS: Among the 50 patients, analyzable CT images were obtained in 42. In 23 of the 42 patients, the lead tips were within 2 mm to the LV blood pool (the LV subendocardial (LVSE) group), 13 between 2 and 4 mm (the Near-LVSE group), and the remaining 6 beyond 4 mm (the Mid-LV septal (Mid-LVS) group). No significant differences in paced QRSd were found among the three groups (LVSE, 107 ± 15 ms; Near-LVSE, 106 ± 13 ms; Mid-LVS, 104 ± 15 ms; p = .87). LVAT in the LVSE (64 ± 7 ms) was significantly shorter than in the Mid-LVS (72 ± 8 ms; p < .05), but not significantly different from that in the Near-LVSE (69 ± 8 ms; p > .05). CONCLUSION: In routine LBBAP practice, paced narrow QRSd and fast LVAT, indicative of physiological pacing, were consistently achieved for lead tip location in the LV subendocardial or near LV subendocardial region.


Asunto(s)
Bradicardia , Estimulación Cardíaca Artificial , Bradicardia/diagnóstico por imagen , Bradicardia/terapia , Estimulación Cardíaca Artificial/métodos , Electrocardiografía/métodos , Sistema de Conducción Cardíaco , Humanos , Tomografía Computarizada por Rayos X