Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 6 de 6
1.
Diagnostics (Basel) ; 14(8)2024 Apr 11.
Article En | MEDLINE | ID: mdl-38667448

The rapid and broad microbiological diagnosis of meningoencephalitis (ME) has been possible thanks to the development of multiplex PCR tests applied to cerebrospinal fluid (CSF). We aimed to assess a new multiplex PCR panel (the QIAstat-Dx ME panel), which we compared to conventional diagnostic tools and the Biofire FilmArray ME Panel. The pathogens analyzed using both methods were Escherichia coli K1, Haemophilus influenzae, Listeria monocytogenes, Neisseria meningitidis, Streptococcus agalactiae, Streptococcus pneumoniae, Enterovirus, herpes simplex virus 1-2, human herpesvirus 6, human parechovirus, varicella zoster virus, and Cryptococcus neoformans/gattii. We used sensitivity, specificity, PPV, NPV, and kappa correlation index parameters to achieve our objective. Fifty CSF samples from patients with suspected ME were included. When conventional methods were used, 28 CSF samples (56%) were positive. The sensitivity and specificity for QIAstat-Dx/ME were 96.43% (CI95%, 79.8-99.8) and 95.24% (75.2-99.7), respectively, whereas the PPV and NPV were 96.43% (79.8-99.8) and 95.24% (75.1-99.7), respectively. The kappa value was 91.67%. Conclusions: A high correlation of the QIAstat-Dx ME panel with reference methods was shown. QIAstat-Dx ME is a rapid-PCR technique to be applied in patients with suspected ME with a high accuracy.

2.
PLoS One ; 17(3): e0264949, 2022.
Article En | MEDLINE | ID: mdl-35286334

BACKGROUND: In the context of COVID-19 pandemic in Catalonia (Spain), the present study analyses respiratory samples collected by the primary care network using Acute Respiratory Infections Sentinel Surveillance System (PIDIRAC) during the 2019-2020 season to complement the pandemic surveillance system in place to detect SARS-CoV-2. The aim of the study is to describe whether SARS-CoV-2 was circulating before the first confirmed case was detected in Catalonia, on February 25th, 2020. METHODS: The study sample was made up of all samples collected by the PIDIRAC primary care network as part of the Influenza and Acute Respiratory Infections (ARI) surveillance system activities. The study on respiratory virus included coronavirus using multiple RT-PCR assays. All positive samples for human coronavirus were subsequently typed for HKU1, OC43, NL63, 229E. Every respiratory sample was frozen at-80°C and retrospectively studied for SARS-CoV-2 detection. A descriptive study was performed, analysing significant differences among variables related to SARS-CoV- 2 cases comparing with rest of coronaviruses cases through a bivariate study with Chi-squared test and statistical significance at 95%. RESULTS: Between October 2019 and April 2020, 878 respiratory samples from patients with acute respiratory infection or influenza syndrome obtained by PIDIRAC were analysed. 51.9% tested positive for influenza virus, 48.1% for other respiratory viruses. SARS-CoV-2 was present in 6 samples. The first positive SARS-CoV-2 case had symptom onset on 2 March 2020. These 6 cases were 3 men and 3 women, aged between 25 and 50 years old. 67% had risk factors, none had previous travel history nor presented viral coinfection. All of them recovered favourably. CONCLUSION: Sentinel Surveillance PIDIRAC enhances global epidemiological surveillance by allowing confirmation of viral circulation and describes the epidemiology of generalized community respiratory viruses' transmission in Catalonia. The system can provide an alert signal when identification of a virus is not achieved in order to take adequate preparedness measures.


COVID-19/diagnosis , Coronavirus/classification , Orthomyxoviridae/classification , RNA, Viral/genetics , Respiratory Tract Infections/virology , Adolescent , Adult , Aged , Aged, 80 and over , COVID-19/epidemiology , Child , Child, Preschool , Coronavirus/genetics , Coronavirus/isolation & purification , Female , Humans , Infant , Male , Middle Aged , Orthomyxoviridae/genetics , Orthomyxoviridae/isolation & purification , Primary Health Care , Retrospective Studies , Sentinel Surveillance , Spain/epidemiology , Young Adult
3.
Int J Infect Dis ; 118: 197-202, 2022 May.
Article En | MEDLINE | ID: mdl-35257905

OBJECTIVES: We described the current incidence and risk factors of bacterial co-infection in hospitalized patients with COVID-19. METHODS: Observational cohort study was performed at the Hospital Clinic of Barcelona (February 2020-February 2021). All patients with COVID-19 who were admitted for >48 hours with microbiological sample collection and procalcitonin (PCT) determination within the first 48 hours were included. RESULTS: A total of 1125 consecutive adults met inclusion criteria. Co-infections were microbiologically documented in 102 (9.1%) patients. Most frequent microorganisms were Streptococcus pneumoniae (79%), Staphylococcus aureus (6.8%), and Haemophilus influenzae (6.8%). Test positivity was 1% (8/803) for blood cultures, 10.1% (79/780) for pneumococcal urinary antigen test, and 11.4% (15/132) for sputum culture. Patients with PCT higher than 0.2, 0.5, 1, and 2 ng/mL had significantly more co-infections than those with lower levels (p=0.017, p=0.031, p<0.001, and p<0.001, respectively). In multivariate analysis, oxygen saturation ≤94% (OR 2.47, CI 1.57-3.86), ferritin levels <338 ng/mL (OR 2.63, CI 1.69-4.07), and PCT higher than 0.2 ng/mL (OR 1.74, CI 1.11-2.72) were independent risk factors for co-infection at hospital admission owing to COVID-19. CONCLUSIONS: Bacterial co-infection in patients hospitalized for COVID-19 is relatively common. However, clinicians could spare antibiotics in patients with PCT values <0.2, especially with high ferritin values and oxygen saturation >94%.


Bacterial Infections , COVID-19 , Coinfection , Adult , Bacterial Infections/microbiology , COVID-19/epidemiology , Coinfection/epidemiology , Ferritins , Hospitals , Humans , Procalcitonin , Retrospective Studies , SARS-CoV-2
4.
Infect Dis Ther ; 11(1): 587-593, 2022 Feb.
Article En | MEDLINE | ID: mdl-34762246

The immense impact of the COVID-19 pandemic on health systems has motivated the scientific community to search for clinical prognostic factors for SARS-CoV-2 infection. Low cycle threshold values (Ct) of diagnostic real-time RT-PCR assays in hospitalized patients have been associated with a poor prognosis in several studies, whereas other studies did not find this association. We explored whether SARS-CoV-2 Ct values at diagnosis were associated with a poor outcome (admission to hospital and death) in 604 community patients diagnosed at primary health centers. Although lower Ct values were found in patients who died of COVID-19, the Ct value was not significantly associated with a worse outcome in a multivariate analysis, while age remained an independent prognostic factor. We did not find evidence to support the role of Ct values as a prognostic factor of COVID-19 in community cases.

5.
PLoS One ; 12(11): e0187458, 2017.
Article En | MEDLINE | ID: mdl-29099868

INTRODUCTION: Diarrhea is a frequent complication in hematologic patients, being an infectious cause frequently suspected. Rapid and accurate detection of gastrointestinal pathogens is vital in immunocompromised hosts. The aim of this study was to compare routine diagnostic methods versus a multiplex polymerase chain reaction (PCR) assay for the diagnosis of infectious diarrhea in immunocompromised hematologic patients. MATERIAL AND METHODS: We conducted a prospective observational study from March 2015 to January 2016 to compare conventional methods for the diagnosis of infectious diarrhea with FIlmArray GI Panel (BioFire-bioMérieux, France). Samples from adult immunocompromised hematologic patients with acute diarrhea were collected. In cases with discordant results, a second multiplex assay was performed (Allplex, Seegene, Korea). The result was considered positive or negative when the same result was obtained by at least two of the methods. RESULTS: A total of 95 samples were obtained from 95 patients (median age of 52 years (46-64)). Sixty-one (64%) episodes were hospital-acquired and 34 (36%) were community-acquired diarrhea. Twenty-five (26%) patients had a positive microbiological result, being Clostridium difficile the most frequent pathogen, followed by Campylobacter spp and norovirus. The concordance between FilmArray methods was good (k = 0.79). The FilmArray GI panel showed a sensitivity of 95%, a specificity of 100% for positive results. The time required to obtain results was markedly reduced with the use of multiplex PCR methods. CONCLUSIONS: Multiplex molecular panels provide a rapid and sensitive tool for the diagnosis of infectious diarrhea, thereby allowing more timely clinical decisions in immunocompromised hematologic patients.


Diarrhea/diagnosis , Hematologic Neoplasms/complications , Immunocompromised Host , Diarrhea/complications , Diarrhea/microbiology , Female , Hematologic Neoplasms/immunology , Humans , Male , Middle Aged , Multiplex Polymerase Chain Reaction , Prospective Studies
6.
J Clin Virol ; 92: 75-82, 2017 07.
Article En | MEDLINE | ID: mdl-28599228

BACKGROUND: Viral load monitoring is essential for patients under treatment for HIV. Beckman Coulter has developed the VERIS HIV-1 Assay for use on the novel, automated DxN VERIS Molecular Diagnostics System.¥ OBJECTIVES: Evaluation of the clinical performance of the new quantitative VERIS HIV-1 Assay at multiple EU laboratories. STUDY DESIGN: Method comparison with the VERIS HIV-1 Assay was performed with 415 specimens at 5 sites tested with COBAS® AmpliPrep/COBAS® TaqMan® HIV-1 Test, v2.0, 169 specimens at 3 sites tested with RealTime HIV-1 Assay, and 202 specimens from 2 sites tested with VERSANT HIV-1 Assay. Patient monitoring sample results from 4 sites were also compared. RESULTS: Bland-Altman analysis showed the average bias between VERIS HIV-1 Assay and COBAS HIV-1 Test, RealTime HIV-1 Assay, and VERSANT HIV-1 Assay to be 0.28, 0.39, and 0.61 log10 cp/mL, respectively. Bias at low end levels below 1000cp/mL showed predicted bias to be <0.3 log10 cp/mL for VERIS HIV-1 Assay versus COBAS HIV-1 Test and RealTime HIV-1 Assay, and <0.5 log10cp/mL versus VERSANT HIV-1 Assay. Analysis on 174 specimens tested with the 0.175mL volume VERIS HIV-1 Assay and COBAS HIV-1 Test showed average bias of 0.39 log10cp/mL. Patient monitoring results using VERIS HIV-1 Assay demonstrated similar viral load trends over time to all comparators. CONCLUSIONS: The VERIS HIV-1 Assay for use on the DxN VERIS System demonstrated comparable clinical performance to COBAS® HIV-1 Test, RealTime HIV-1 Assay, and VERSANT HIV-1 Assay.


HIV Infections/diagnosis , HIV-1/physiology , Molecular Diagnostic Techniques , RNA, Viral/blood , Viral Load/methods , Europe , HIV Infections/virology , HIV-1/genetics , Humans , Intersectoral Collaboration , Mass Screening , Real-Time Polymerase Chain Reaction/methods , Sensitivity and Specificity , Viral Load/instrumentation
...