Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Echocardiography ; 40(8): 768-774, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37342979

RESUMEN

BACKGROUND: Aortic valve stenosis (AS) is the most common valvular heart disease worldwide. When timely intervention is performed, aortic valve replacement can improve patients' quality and duration of life. Load-independent left ventricular (LV) functional assessments, such as myocardial work indices (MWIs) and LV diastolic function parameters, could help clinicians decide on the optimal timing of intervention. AIMS: To evaluate the reliability of MWI in AS patients and the changes in MWI and LV diastolic function after transcatheter aortic valve replacement (TAVR). METHODS: We enrolled 53 consecutive patients with severe AS undergoing TAVR admitted between March 2021 and November 2021. MWIs and LV diastolic function were assessed before and after TAVR for each patient. RESULTS: All MWIs and LV diastolic function indices improved after TAVR. The degree of MWIs improvement was higher in patients with lower prior-TAVR MWI values, while the more severe the impairment of diastolic function, the greater the post-TAVR benefit. CONCLUSION: The introduction of myocardial work parameters into the routine assessment of patients with AS could improve our understanding of cardiac performance and aid in identifying the optimal timing for surgical or percutaneous treatment.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reproducibilidad de los Resultados , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Función Ventricular Izquierda , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Índice de Severidad de la Enfermedad , Estudios Retrospectivos
2.
Diagnostics (Basel) ; 13(7)2023 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-37046483

RESUMEN

Carotid artery stenting (CAS) is usually performed through a femoral vascular access using 6-9 Fr guiding catheters. We investigated whether a systematic distal radial approach using 5 Fr guiding sheaths was a safe and effective alternative to transfemoral approach for CAS. From July 2020 to October 2022, two operators at our center systematically performed CAS using a 5 Fr distal radial approach in consecutive patients. The main endpoints of the study were procedural success via distal radial and via proximal or distal radial access. The learning curve was evaluated by comparing the first half of patients versus the second half of patients enrolled. Procedural data and 30-day clinical outcomes were collected. Fifty-one patients were prospectively enrolled. CAS was effectively performed via distal radial access in 45 patients (88%). Overall radial artery success was 92%. Distal radial CAS was successfully performed in 20 out of the first 25 patients enrolled (80%), and in 25 of the last 26 patients enrolled (96%; p = 0.07). Significantly less contrast was administered in the last 26 patients compared to the first 25 enrolled (110 (70, 140) mL vs. 120 (107, 150) mL; p = 0.045). Radial artery occlusion was reported in 1 patient (2%). Only 1 minor stroke (2%) was reported in-hospital and at 30-day follow-up. In conclusion, distal radial CAS using 5 Fr catheters was a safe procedure with a high success rate. The procedure had a relatively short learning curve in operators familiar with transfemoral CAS.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA